{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T15:13:52Z","timestamp":1781622832353,"version":"3.54.5"},"reference-count":49,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2021,12,24]],"date-time":"2021-12-24T00:00:00Z","timestamp":1640304000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A capacitive biosensor for the detection of protein A was developed. Gold electrodes were fabricated by thermal evaporation and patterned by photoresist photolithography. A layer-by-layer (LbL) assembly of thiourea (TU) and HAuCl4 and chemical reduction was utilized to prepare a probe with a different number of layers of TU and gold nanoparticles (AuNPs). The LbL-modified electrodes were used for the immobilization of human IgG. The binding interaction between human IgG and protein A was detected as a decrease in capacitance signal, and that change was used to investigate the correlation between the height of the LbL probe and the sensitivity of the capacitive measurement. The results showed that the initial increase in length of the LbL probe can enhance the amount of immobilized human IgG, leading to a more sensitive assay. However, with thicker LbL layers, a reduction of the sensitivity of the measurement was registered. The performance of the developed system under optimum set-up showed a linearity in response from 1 \u00d7 10\u221216 to 1 \u00d7 10\u221213 M, with the limit detection of 9.1 \u00d7 10\u221217 M, which could be interesting for the detection of trace amounts of protein A from affinity isolation of therapeutic monoclonal antibodies.<\/jats:p>","DOI":"10.3390\/s22010099","type":"journal-article","created":{"date-parts":[[2021,12,27]],"date-time":"2021-12-27T01:06:54Z","timestamp":1640567214000},"page":"99","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["A Sensitive Capacitive Biosensor for Protein a Detection Using Human IgG Immobilized on an Electrode Using Layer-by-Layer Applied Gold Nanoparticles"],"prefix":"10.3390","volume":"22","author":[{"given":"Kosin","family":"Teeparuksapun","sequence":"first","affiliation":[{"name":"Science Program, Department of General Education, Faculty of Liberal Arts, Rajamangala University of Technology Srivijaya, Songkhla 90000, Thailand"},{"name":"Division of Biotechnology, Lund University, P.O. Box 124, 221 00 Lund, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Hedstr\u00f6m","sequence":"additional","affiliation":[{"name":"Division of Biotechnology, Lund University, P.O. Box 124, 221 00 Lund, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bo","family":"Mattiasson","sequence":"additional","affiliation":[{"name":"Division of Biotechnology, Lund University, P.O. Box 124, 221 00 Lund, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2021,12,24]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/j.tibtech.2009.10.002","article-title":"Immunochemical binding assays for detection and quantification of trace impurities in biotechnological production","volume":"28","author":"Mattiasson","year":"2010","journal-title":"Trends Biotechnol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/j.chroma.2019.02.056","article-title":"Identification and tracking of problematic host cell proteins removed by a synthetic, highly functionalized nonwoven media in downstream bioprocessing of monoclonal antibodies","volume":"1595","author":"Gilgunn","year":"2019","journal-title":"J. Chromatogr. A"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1260","DOI":"10.1002\/bit.25882","article-title":"Host cell protein impurities in chromatographic polishing steps for monoclonal antibody purification","volume":"113","author":"Levy","year":"2015","journal-title":"Biotechnol. Bioeng."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/j.ab.2012.05.018","article-title":"Identification and quantification of host cell protein impurities in biotherapeutics using mass spectrometry","volume":"428","author":"Schenauer","year":"2012","journal-title":"Anal. Biochem."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1016\/j.visres.2003.09.032","article-title":"Impurity of recombinant adeno-associated virus type 2 affects the transduction characteristics following subretinal injection in the rat","volume":"44","author":"Shen","year":"2004","journal-title":"Vis. Res."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.jim.2008.10.015","article-title":"Trace level analysis of leached protein A in bioprocess samples without interference from the large excess of rhMAb IgG","volume":"341","author":"Gunawan","year":"2009","journal-title":"Immunol. Methods"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1016\/j.jpba.2012.05.027","article-title":"Full automation and validation of a flexible ELISA platform for host cell protein and protein a impurity detection in biopharmaceuticals","volume":"70","author":"Rey","year":"2012","journal-title":"J. Pharm. Biomed."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1038\/nm1079","article-title":"Staphylococcus aureus protein A induces airway epithelial inflammatory responses by activating TNFR1","volume":"10","author":"Gomez","year":"2004","journal-title":"Nat. Med."},{"key":"ref_9","first-page":"347","article-title":"Clinical-trials with staphylococcal protein-A","volume":"3","author":"Bensinger","year":"1984","journal-title":"J. Biol. Response Mod."},{"key":"ref_10","first-page":"4486","article-title":"Staphylococcal protein-A column\u2014Correlation of mitogenicity of perfused plasma with clinical-response","volume":"45","author":"Bertram","year":"1985","journal-title":"Cancer Res."},{"key":"ref_11","first-page":"283","article-title":"Characterization and analysis of biopharmaceutical proteins","volume":"10","author":"Luo","year":"2011","journal-title":"Sep. Sci. Technol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/0021-9673(92)85292-2","article-title":"Development of an enzyme-linked immunosorbent assay for C.I. Reactive Blue 2 and its application to a comparison of the stability and performance of a perfluorocarbon support with other immobilised C.I. Reactive Blue 2 affinity adsorbents","volume":"623","author":"Stewart","year":"1992","journal-title":"J. Chromatogr. A"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1977","DOI":"10.1016\/j.bios.2010.01.020","article-title":"Sub-attomolar detection of cholera toxin using a label-free capacitive immunosensor","volume":"25","author":"Loyprasert","year":"2010","journal-title":"Biosens. Bioelectron."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"8406","DOI":"10.1021\/ac102144a","article-title":"Ultrasensitive detection of HIV-1 p24 antigen using nanofunctionalized surfaces in a capacitive immunosensor","volume":"82","author":"Teeparuksapun","year":"2010","journal-title":"Anal. Chem."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/j.jbiotec.2011.11.004","article-title":"Capacitive immunosensor for the detection of host cell proteins","volume":"157","author":"Teeparuksapun","year":"2012","journal-title":"J. Biotechnol."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1080\/10739149908085841","article-title":"Instrumentation for direct capacitive biosensors","volume":"27","author":"Berggren","year":"1999","journal-title":"Instrum. Sci. Technol."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1002\/1521-4109(200103)13:3<173::AID-ELAN173>3.0.CO;2-B","article-title":"Capacitive biosensors","volume":"13","author":"Berggren","year":"2001","journal-title":"Electroanalysis"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"3651","DOI":"10.1021\/ac970203e","article-title":"Capacitance measurements of antibody\u2212antigen interactions in a flow system","volume":"69","author":"Berggren","year":"1997","journal-title":"Anal. Chem."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1016\/j.talanta.2018.06.033","article-title":"Phage-based capacitive biosensor for Salmonella detection","volume":"188","author":"Niyomdecha","year":"2018","journal-title":"Talanta"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/S0003-2670(99)00718-7","article-title":"A disposable protein A-based immunosensor for flow-injection assay with electrochemical detection","volume":"404","author":"Valat","year":"2000","journal-title":"Anal. Chim. Acta"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/S0003-2670(03)00991-7","article-title":"Direct oriented immobilization of F(ab\u2032) antibody fragments on gold","volume":"496","author":"Brogan","year":"2003","journal-title":"Anal. Chim. Acta"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.chroma.2007.05.023","article-title":"Improving immunobinding using oriented immobilization of an oxidized antibody","volume":"1161","author":"Kang","year":"2007","journal-title":"J. Chromatogr. A"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1016\/j.aca.2011.05.038","article-title":"Label-free capacitive immunosensors for ultra-trace detection based on the increase of immobilized antibodies on silver nanoparticles","volume":"699","author":"Dawan","year":"2011","journal-title":"Anal. Chim. Acta"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.bios.2004.10.014","article-title":"Continuous measurements of a binding reaction using a capacitive biosensor","volume":"21","author":"Galaev","year":"2005","journal-title":"Biosens. Bioelectron."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/j.aca.2008.12.035","article-title":"A capacitive immunosensor for detection of cholera toxin","volume":"634","author":"Labib","year":"2009","journal-title":"Anal. Chim. Acta"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1007\/BF03214964","article-title":"Gold nanoparticle-based biosensors","volume":"43","author":"Li","year":"2010","journal-title":"Gold Bull."},{"key":"ref_27","first-page":"281","article-title":"Nanoparticles of different shapes for biosensor applications","volume":"1112","author":"Narayanan","year":"2012","journal-title":"ACS Symp. Ser. Am. Chem. Soc."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1186\/s12951-018-0374-x","article-title":"Development of gold nanoparticles biosensor for ultrasensitive diagnosis of foot and mouth disease virus","volume":"16","author":"Hamdy","year":"2018","journal-title":"J. Nanobiotechnol."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1007\/s11468-011-9228-1","article-title":"A Review on functionalized gold nanoparticles for biosensing applications","volume":"6","author":"Zeng","year":"2011","journal-title":"Plasmonics"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1016\/j.ab.2005.04.040","article-title":"Direct electrochemistry and electrocatalysis of heme proteins immobilized on gold nanoparticles stabilized by chitosan","volume":"342","author":"Feng","year":"2005","journal-title":"Anal. Biochem."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/j.colsurfb.2004.10.022","article-title":"Study on the immobilization of anti-IgG on Au-colloid modified gold electrode via potentiometric immunosensor, cyclic voltammetry, and electrochemical impedance techniques","volume":"40","author":"Fu","year":"2005","journal-title":"Colloids Surf. B Biointerfaces"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1330","DOI":"10.1016\/j.talanta.2007.08.046","article-title":"Amperometric immunosensors based on layer-by-layer assembly of gold nanoparticles and methylene blue on thiourea modified glassy carbon electrode for determination of human chorionic gonadotrophin","volume":"74","author":"Chai","year":"2008","journal-title":"Talanta"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"933","DOI":"10.1039\/b719389k","article-title":"Quartz crystal microbalance immunoassay for carcinoma antigen 125 based on gold nanowire-functionalized biomimetic interface","volume":"133","author":"Tang","year":"2008","journal-title":"Analyst"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"838","DOI":"10.1016\/j.bios.2006.03.009","article-title":"Amperometric glucose biosensor based on layer-by-layer assembly of multilayer films composed of chitosan, gold nanoparticles and glucose oxidase modified Pt electrode","volume":"22","author":"Wu","year":"2007","journal-title":"Biosens. Bioelectron."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1134\/S003602440706009X","article-title":"A theoretical study of the activation of methane by Gold (III) homoleptic complexes","volume":"81","author":"Pichugina","year":"2007","journal-title":"Russ. J. Phys. Chem."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1016\/j.aca.2008.04.022","article-title":"Enhanced sensitivity for deoxyribonucleic acid electrochemical impedance sensor: Gold nanoparticle\/polyaniline nanotube membranes","volume":"616","author":"Feng","year":"2008","journal-title":"Anal. Chim. Acta"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1573","DOI":"10.1007\/s11051-010-9908-3","article-title":"Antibody immobilization on gold nanoparticles coated layer-by-layer with polyelectrolytes","volume":"13","author":"Masereel","year":"2010","journal-title":"J. Nanopart. Res."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"215501","DOI":"10.1088\/0957-4484\/20\/21\/215501","article-title":"A method of layer-by-layer gold nanoparticle hybridization in a quartz crystal microbalance DNA sensing system used to detect dengue virus","volume":"20","author":"Chen","year":"2009","journal-title":"Nanotechnology"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"1717","DOI":"10.1039\/c0nr01023e","article-title":"Structural control of gold nanoparticles self-assemblies by layer-by-layer process","volume":"3","author":"Machado","year":"2011","journal-title":"Nanoscale"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"21217","DOI":"10.1038\/s41598-020-78068-w","article-title":"Nanohybrid-based immunosensor prepared for Helicobacter pylori BabA antigen detection through immobilized antibody assembly with @ Pdnano\/rGO\/PEDOT sensing platform","volume":"10","author":"Gupta","year":"2020","journal-title":"Sci. Rep."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1007\/s00604-007-0779-y","article-title":"Layer-by-layer immobilization of horseradish peroxidase on a gold electrode modified with colloidal gold nanoparticles","volume":"161","author":"Liu","year":"2008","journal-title":"Microchim. Acta"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"5396","DOI":"10.1021\/ma00072a016","article-title":"Assembly of thin-films by means of successive deposition of alternate layers of DNA and poly (Allylamine)","volume":"26","author":"Lvov","year":"1993","journal-title":"Macromolecules"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"6117","DOI":"10.1021\/ja00127a026","article-title":"Assembly of multicomponent protein films by means of electrostatic layer-by-layer adsorption","volume":"117","author":"Lvov","year":"1995","journal-title":"J. Am. Chem. Soc."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/j.jcis.2006.06.019","article-title":"Preparation of hollow capsule-stabilized gold nanoparticles through the encapsulation of the dendrimer","volume":"302","author":"Wu","year":"2006","journal-title":"J. Colloid Interface Sci."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"1220","DOI":"10.1002\/elan.200704169","article-title":"A novel electrochemical DNA biosensor fabricated with layer-by-layer covalent attachment of multiwalled carbon nanotubes and gold nanoparticles","volume":"20","author":"Ma","year":"2008","journal-title":"Electroanalysis"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"1021","DOI":"10.1016\/j.addr.2012.01.003","article-title":"Engineering nanomedicines using stimuli-responsive biomaterials","volume":"64","author":"Wang","year":"2012","journal-title":"Adv. Drug Deliv. Rev."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/j.aca.2006.01.021","article-title":"A reusable capacitive immunosensor for carcinoembryonic antigen (CEA) detection using thiourea modified gold electrode","volume":"561","author":"Limbut","year":"2006","journal-title":"Anal. Chim. Acta"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"2527","DOI":"10.1351\/pac199466122527","article-title":"Recommendations for nomenclature of ion-selective electrodes (IUPAC Recommendations 1994)","volume":"66","author":"Buck","year":"1994","journal-title":"Pure Appl. Chem."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"1021","DOI":"10.1016\/j.tibtech.2017.06.001","article-title":"Nanoenvironmental effects dramatically influence the sensitivity of immunoassays","volume":"35","author":"Mattiasson","year":"2017","journal-title":"Trends Biotechnol."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/1\/99\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T07:52:41Z","timestamp":1760169161000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/1\/99"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12,24]]},"references-count":49,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,1]]}},"alternative-id":["s22010099"],"URL":"https:\/\/doi.org\/10.3390\/s22010099","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,12,24]]}}}