{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,9]],"date-time":"2026-11-09T23:14:57Z","timestamp":1794266097009,"version":"4.9.0"},"reference-count":37,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2021,12,26]],"date-time":"2021-12-26T00:00:00Z","timestamp":1640476800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Polar Electro Oy","award":["-"],"award-info":[{"award-number":["-"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Heart rate (HR) and heart rate variability (HRV) can be monitored with wearable devices throughout the day. Resting HRV in particular, reflecting cardiac parasympathetic activity, has been proposed to be a useful marker in the monitoring of health and recovery from training. This study examined the validity of the wrist-based photoplethysmography (PPG) method to measure HR and HRV at rest. Recreationally endurance-trained participants recorded pulse-to-pulse (PP) and RR intervals simultaneously with a PPG-based watch and reference heart rate sensor (HRS) at a laboratory in a supine position (n = 39; 5-min recording) and at home during sleep (n = 29; 4-h recording). In addition, analyses were performed from pooled laboratory data (n = 11344 PP and RR intervals). Differences and correlations were analyzed between the HRS- and PPG-derived HR and LnRMSSD (the natural logarithm of the root mean square of successive differences). A very good agreement was found between pooled PP and RR intervals with a mean bias of 0.17 ms and a correlation coefficient of 0.993 (p &lt; 0.001). In the laboratory, HR did not differ between the devices (mean bias 0.0 bpm), but PPG slightly underestimated the nocturnal recordings (mean bias \u22120.7 bpm, p &lt; 0.001). PPG overestimated LnRMSSD both in the laboratory (mean bias 0.20 ms, p &lt; 0.001) and nocturnal recordings (mean bias 0.17 ms, p &lt; 0.001). However, very strong intraclass correlations in the nocturnal recordings were found between the devices (HR: 0.998, p &lt; 0.001; LnRMSSD: 0.931, p &lt; 0.001). In conclusion, PPG was able to measure HR and HRV with adequate accuracy in recreational athletes. However, when strict absolute values are of importance, systematic overestimation, which seemed to especially concern participants with low LnRMSSD, should be acknowledged.<\/jats:p>","DOI":"10.3390\/s22010137","type":"journal-article","created":{"date-parts":[[2021,12,27]],"date-time":"2021-12-27T01:06:54Z","timestamp":1640567214000},"page":"137","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":46,"title":["Validity of the Wrist-Worn Polar Vantage V2 to Measure Heart Rate and Heart Rate Variability at Rest"],"prefix":"10.3390","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4819-0619","authenticated-orcid":false,"given":"Olli-Pekka","family":"Nuuttila","sequence":"first","affiliation":[{"name":"Faculty of Sport and Health Sciences, University of Jyv\u00e4skyl\u00e4, 40014 Jyv\u00e4skyl\u00e4, Finland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elisa","family":"Korhonen","sequence":"additional","affiliation":[{"name":"Faculty of Sport and Health Sciences, University of Jyv\u00e4skyl\u00e4, 40014 Jyv\u00e4skyl\u00e4, Finland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jari","family":"Laukkanen","sequence":"additional","affiliation":[{"name":"Institute of Public Health and Clinical Nutrition, University of Eastern Finland, 70210 Kuopio, Finland"},{"name":"Central Finland Health Care District, Department of Internal Medicine, 40620 Jyv\u00e4skyl\u00e4, Finland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3822-1733","authenticated-orcid":false,"given":"Heikki","family":"Kyr\u00f6l\u00e4inen","sequence":"additional","affiliation":[{"name":"Faculty of Sport and Health Sciences, University of Jyv\u00e4skyl\u00e4, 40014 Jyv\u00e4skyl\u00e4, Finland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2021,12,26]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1249\/FIT.0000000000000631","article-title":"FACSM worldwide survey of fitness trends for 2021","volume":"25","author":"Thompson","year":"2021","journal-title":"ACSMs Health Fit. J."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"e18694","DOI":"10.2196\/18694","article-title":"Reliability and validity of commercially available wearable devices for measuring steps, energy expenditure, and heart rate: Systematic review","volume":"8","author":"Fuller","year":"2020","journal-title":"JMIR Mhealth Uhealth"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"e9157","DOI":"10.2196\/jmir.9157","article-title":"Using fitness trackers and smartwatches to measure physical activity in research: Analysis of consumer wrist-worn wearables","volume":"20","author":"Henriksen","year":"2018","journal-title":"J. Med. Internet Res."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"640","DOI":"10.1152\/ajpheart.00054.2005","article-title":"Intraindividual validation of heart rate variability indexes to measure vagal effects on hearts","volume":"290","author":"Rusko","year":"2006","journal-title":"Am. J. Physiol. Heart Circ. Physiol."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Altini, M., and Plews, D. (2021). What is behind changes in resting heart rate and heart rate variability? A large-scale analysis of longitudinal measurements acquired in free-living. Sensors, 21.","DOI":"10.3390\/s21237932"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"341","DOI":"10.3389\/fphys.2019.00341","article-title":"Home monitoring of heart rate as a predictor of imminent cardiovascular events","volume":"10","author":"Tulppo","year":"2019","journal-title":"Front. Physiol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"3196","DOI":"10.1161\/STROKEAHA.110.607697","article-title":"Decreased nighttime heart rate variability is associated with increased stroke risk","volume":"42","author":"Binici","year":"2011","journal-title":"Stroke"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1016\/j.sleep.2019.11.1259","article-title":"Sleep heart rate variability assists the automatic prediction of long-term cardiovascular outcomes","volume":"67","author":"Zhang","year":"2020","journal-title":"Sleep Med."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"736","DOI":"10.1519\/JSC.0000000000002001","article-title":"Endurance running training individually guided by HRV in untrained women","volume":"33","author":"Ferraro","year":"2019","journal-title":"J. Strength Cond. Res."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1007\/s00421-007-0552-2","article-title":"Endurance training guided individually by daily heart rate variability measurements","volume":"101","author":"Kiviniemi","year":"2007","journal-title":"Eur. J. Appl. Physiol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1123\/ijspp.2018-0122","article-title":"Training prescription guided by heart-rate variability in cycling","volume":"14","author":"Javaloyes","year":"2019","journal-title":"Int J. Sports Physiol. Perform."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"585870","DOI":"10.3389\/fspor.2021.585870","article-title":"Assessing the accuracy of popular commercial technologies that measure resting heart rate and heart rate variability","volume":"3","author":"Stone","year":"2021","journal-title":"Front. Sports Act. Living"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1038\/s41746-020-0226-6","article-title":"Investigating sources of inaccuracy in wearable optical heart rate sensors","volume":"3","author":"Bent","year":"2020","journal-title":"NPJ Digit. Med."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1186\/s40101-020-00233-x","article-title":"Pulse rate variability: A new biomarker, not a surrogate for heart rate variability","volume":"39","author":"Yuda","year":"2020","journal-title":"J. Physiol. Anthropol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1324","DOI":"10.1123\/ijspp.2016-0668","article-title":"Comparison of heart-rate-variability recording with smartphone photoplethysmography, polar H7 chest strap, and electrocardiography","volume":"12","author":"Plews","year":"2017","journal-title":"Int. J. Sports Physiol. Perform."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"04NT01","DOI":"10.1088\/1361-6579\/ab840a","article-title":"Feasible assessment of recovery and cardiovascular health: Accuracy of nocturnal HR and HRV assessed via ring PPG in comparison to medical grade ECG","volume":"41","author":"Kinnunen","year":"2020","journal-title":"Physiol. Meas."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Hernando, D., Roca, S., Sancho, J., Alesanco, \u00c1., and Bail\u00f3n, R. (2018). Validation of the apple watch for heart rate variability measurements during relax and mental stress in healthy subjects. Sensors, 18.","DOI":"10.3390\/s18082619"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Bellenger, C.R., Miller, D., Halson, S.L., Roach, G., and Sargent, C. (2021). Wrist-based photoplethysmography assessment of heart rate and heart rate variability: Validation of WHOOP. Sensors, 21.","DOI":"10.3390\/s21103571"},{"key":"ref_19","first-page":"e16620","article-title":"A contact-free, ballistocardiography-based monitoring system (Emfit QS) for measuring nocturnal heart rate and heart rate variability: Validation study","volume":"5","author":"Vesterinen","year":"2020","journal-title":"JBME"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.ijcard.2012.03.119","article-title":"How accurate is pulse rate variability as an estimate of heart rate variability? A review on studies comparing photoplethysmographic technology with an electrocardiogram","volume":"166","author":"Vagedes","year":"2013","journal-title":"Int. J. Cardiol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1001\/jamacardio.2016.3340","article-title":"Accuracy of wrist-worn heart rate monitors","volume":"2","author":"Wang","year":"2017","journal-title":"JAMA Cardiol."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"e9754","DOI":"10.2196\/mhealth.9754","article-title":"Evaluating the validity of current mainstream wearable devices in fitness tracking under various physical activities: Comparative study","volume":"6","author":"Xie","year":"2018","journal-title":"JMIR Mhealth Uhealth"},{"key":"ref_23","first-page":"212","article-title":"Comparison between photoplethysmographic heart rate monitor from Polar Vantage M and Polar V800 with H10 chest strap while running on a treadmill: Validation of the Polar Precision PrimeTM photoplestimographic system","volume":"235","year":"2021","journal-title":"Proc. Inst. Mech. Eng. Part P J. Sports Eng. Technol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"e10893","DOI":"10.7717\/peerj.10893","article-title":"Validity of the polar vantage M watch when measuring heart rate at different exercise intensities","volume":"9","author":"Shumate","year":"2021","journal-title":"PeerJ"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1525","DOI":"10.1007\/s00421-019-04142-5","article-title":"RR interval signal quality of a heart rate monitor and an ECG Holter at rest and during exercise","volume":"119","author":"Schweizer","year":"2019","journal-title":"Eur. J. Appl. Physiol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"73","DOI":"10.3389\/fphys.2014.00073","article-title":"Monitoring training status with HR measures: Do all roads lead to Rome?","volume":"5","author":"Buchheit","year":"2014","journal-title":"Front. Physiol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"773","DOI":"10.1007\/s40279-013-0071-8","article-title":"Training adaptation and heart rate variability in elite endurance athletes: Opening the door to effective monitoring","volume":"43","author":"Plews","year":"2013","journal-title":"Sports Med."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"585","DOI":"10.5664\/jcsm.7050","article-title":"The validity of a new consumer-targeted wrist device in sleep measurement: An overnight comparison against polysomnography in children and adolescents","volume":"14","author":"Pesonen","year":"2018","journal-title":"J. Clin. Sleep Med."},{"key":"ref_29","unstructured":"Polar Electro Oy (2021, December 17). Polar Presicion Prime OHR [White Paper]. Available online: https:\/\/www.polar.com\/sites\/default\/files\/static\/science\/white-papers\/polar-precision-prime-white-paper.pdf."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research","volume":"15","author":"Koo","year":"2016","journal-title":"J. Chiropr. Med."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1475-925X-4-62","article-title":"Assessment of pulse rate variability by the method of pulse frequency demodulation","volume":"4","author":"Hayano","year":"2005","journal-title":"Biomed. Eng. Online"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1123\/ijspp.2013-0455","article-title":"Monitoring training with heart-rate variability: How much compliance is needed for valid assessment?","volume":"9","author":"Plews","year":"2014","journal-title":"Int. J. Sports Physiol. Perform."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1055\/s-0030-1249625","article-title":"Effects of moderate and heavy endurance exercise on nocturnal HRV","volume":"31","author":"Hynynen","year":"2010","journal-title":"Int. J. Sports Med."},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Nuuttila, O.P., Nummela, A., H\u00e4kkinen, K., Seip\u00e4j\u00e4rvi, S., and Kyr\u00f6l\u00e4inen, H. (2021). Monitoring training and recovery during a period of increased intensity or volume in recreational endurance athletes. Int. J. Environ. Res. Public Health, 18.","DOI":"10.3390\/ijerph18052401"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/j.autneu.2005.06.002","article-title":"Is slow wave sleep an appropriate recording condition for heart rate variability analysis","volume":"121","author":"Brandenberger","year":"2005","journal-title":"Auton. Neurosci."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"646","DOI":"10.1152\/japplphysiol.00927.2016","article-title":"The impact of artifact correction methods of RR series on heart rate variability parameters","volume":"124","author":"Silva","year":"2018","journal-title":"J. Appl. Physiol."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"779","DOI":"10.3389\/fphys.2020.00779","article-title":"Heart rate variability (HRV) and pulse rate variability (PRV) for the assessment of autonomic responses","volume":"11","author":"Budidha","year":"2020","journal-title":"Front. Physiol."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/1\/137\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T07:53:37Z","timestamp":1760169217000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/1\/137"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12,26]]},"references-count":37,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,1]]}},"alternative-id":["s22010137"],"URL":"https:\/\/doi.org\/10.3390\/s22010137","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,12,26]]}}}