{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T22:32:52Z","timestamp":1768343572324,"version":"3.49.0"},"reference-count":28,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2021,12,28]],"date-time":"2021-12-28T00:00:00Z","timestamp":1640649600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["61271334"],"award-info":[{"award-number":["61271334"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["61073115"],"award-info":[{"award-number":["61073115"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>In this paper, the graphic representation method is used to study the multiple characteristics of heart sounds from a resting state to a state of motion based on single- and four-channel heart-sound signals. Based on the concept of integration, we explore the representation method of heart sound and blood pressure during motion. To develop a single- and four-channel heart-sound collector, we propose new concepts such as a sound-direction vector of heart sound, a motion\u2013response curve of heart sound, the difference value, and a state-change-trend diagram. Based on the acoustic principle, the reasons for the differences between multiple-channel heart-sound signals are analyzed. Through a comparative analysis of four-channel motion and resting-heart sounds, from a resting state to a state of motion, the maximum and minimum similarity distances in the corresponding state-change-trend graphs were found to be 0.0038 and 0.0006, respectively. In addition, we provide several characteristic parameters that are both sensitive (such as heart sound amplitude, blood pressure, systolic duration, and diastolic duration) and insensitive (such as sound-direction vector, state-change-trend diagram, and difference value) to motion, thus providing a new technique for the diverse analysis of heart sounds in motion.<\/jats:p>","DOI":"10.3390\/s22010181","type":"journal-article","created":{"date-parts":[[2021,12,28]],"date-time":"2021-12-28T06:55:03Z","timestamp":1640674503000},"page":"181","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Analysis of Heart-Sound Characteristics during Motion Based on a Graphic Representation"],"prefix":"10.3390","volume":"22","author":[{"given":"Chen-Jun","family":"She","sequence":"first","affiliation":[{"name":"College of Electronic and Optical Engineering, Nanjing University of Posts and Telecommunications, Nanjing 210023, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xie-Feng","family":"Cheng","sequence":"additional","affiliation":[{"name":"College of Electronic and Optical Engineering, Nanjing University of Posts and Telecommunications, Nanjing 210023, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kai","family":"Wang","sequence":"additional","affiliation":[{"name":"College of Electronic and Optical Engineering, Nanjing University of Posts and Telecommunications, Nanjing 210023, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2021,12,28]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1007\/s11432-011-4456-8","article-title":"Research on heart sound identification technology","volume":"55","author":"Cheng","year":"2012","journal-title":"Sci. China Inf. Sci."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1016\/j.bspc.2014.05.002","article-title":"A novel heart sound activity detection framework for automated heart sound analysis","volume":"13","author":"Varghees","year":"2014","journal-title":"Biomed. Signal Process. Control"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Cheng, X., Wang, P., and She, C. (2020). Biometric Identification Method for Heart Sound Based on Multimodal Multiscale Dispersion Entropy. Entropy, 22.","DOI":"10.3390\/e22020238"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1730","DOI":"10.1088\/1361-6579\/aa6e9f","article-title":"Performance of an open-source heart sound segmentation algorithm on eight independent databases","volume":"38","author":"Liu","year":"2017","journal-title":"Physiol. Meas."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"21797","DOI":"10.1038\/s41598-020-77994-z","article-title":"Automatic recognition of murmurs of ventricular septal defect using convolutional recurrent neural networks with temporal attentive pooling","volume":"10","author":"Wang","year":"2020","journal-title":"Sci. Rep."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Beritelli, F., and Spadaccini, A. (2009, January 5\u20137). Human identity verification based on Mel frequency analysis of digital heart sounds. Proceedings of the Radar Conference, EuRAD 2009, Santorini, Greece.","DOI":"10.1109\/ICDSP.2009.5201109"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"843","DOI":"10.1007\/s11760-015-0826-9","article-title":"A comparative approach between cepstral features for human authentication using heart sounds","volume":"10","author":"Farrag","year":"2016","journal-title":"Signal Image Video Process."},{"key":"ref_8","first-page":"372","article-title":"S1 and S2 Heart Sound Recognition using Deep Neural Networks","volume":"64","author":"Chen","year":"2016","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1049\/iet-bmt.2015.0033","article-title":"Heart-ID: Human identity recognition using heart sounds based on modifying mel-frequency cepstral features","volume":"5","author":"Abbas","year":"2016","journal-title":"IET Biom."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1","DOI":"10.4236\/jbise.2013.61001","article-title":"Multi-center pragmatic studies evaluating the time indicator of cardiac perfusion reserve","volume":"6","author":"Xiong","year":"2013","journal-title":"J. Biomed. Sci. Eng."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1950031","DOI":"10.1142\/S0219519419500313","article-title":"Heart Sound Model Based on Cascaded and Lossless Acoustic Tubes","volume":"19","author":"Wang","year":"2019","journal-title":"J. Mech. Med. Biol."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Al-Shamma, S.D., and Al-Noaemi, M.C. (2010, January 16\u201318). Heart sound as a physiological biometric signature. Proceedings of the 5th Cairo International Biomedical Engineering Conference, Cairo, Egypt.","DOI":"10.1109\/CIBEC.2010.5716099"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"2010","DOI":"10.1166\/jmihi.2020.3127","article-title":"Advanced Digital Signal Processing Techniques on the Classification of the Heart Sound Signals","volume":"10","author":"Zhong","year":"2020","journal-title":"J. Med. Imaging Health Inform."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"62874","DOI":"10.1109\/ACCESS.2018.2876119","article-title":"Spectral Fault Recovery Analysis Revisited With Normal and Abnormal Heart Sound Signals","volume":"6","author":"Elamaran","year":"2018","journal-title":"IEEE Access"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1016\/j.bspc.2018.10.018","article-title":"Multi-centroid diastolic duration distribution based HSMM for heart sound segmentation","volume":"48","author":"Kamson","year":"2019","journal-title":"Biomed. Signal Process. Control"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"2530","DOI":"10.3390\/s130202530","article-title":"Heart sound biometric system based on marginal spectrum analysis","volume":"13","author":"Zhao","year":"2013","journal-title":"J. Sens."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"906","DOI":"10.1016\/j.patcog.2007.07.018","article-title":"Heart sound as a biometric","volume":"41","author":"Phua","year":"2008","journal-title":"J. Pattern Recognit."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"075021","DOI":"10.1063\/1.5110203","article-title":"Study on chaotic characteristics of heart sound based on correlation dimension and K entropy","volume":"9","author":"She","year":"2019","journal-title":"AIP Adv."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Castro, A., Gomes, P., Mattos, S.S., and Coimbra, M.T. (2016, January 16\u201320). Comparison between Users of a New Methodology for Heart Sound Auscultation. Proceedings of the 38th Annual International Conference of the IEEE-Engineering-in-Medicine-and-Biology-Society, Orlando, FL, USA.","DOI":"10.1109\/EMBC.2016.7591945"},{"key":"ref_20","unstructured":"Guo, X., Xiao, S., Jing, P., Yan, Y., and Xin, T. (2007, January 23\u201327). Heart sound recognition algorithm based on Probabilistic neural network for evaluating cardiac contractility change trend. Proceedings of the 2007 IEEE\/ICME International Conference on Complex Medical Engineering, Beijing, China."},{"key":"ref_21","first-page":"202","article-title":"Research on First Heart Sound and Second Heart Sound Amplitude Variability and Reversal Phenomenon\u2014A New Finding in Athletic Heart Study","volume":"29","author":"Wu","year":"2009","journal-title":"J. Med. Biol. Eng."},{"key":"ref_22","first-page":"94","article-title":"Effect of cardiopulmonary exercise test on cardiopulmonary reserve function and prognosis of patients with coronary heart disease","volume":"28","author":"Li","year":"2020","journal-title":"Chin. J. Med. Eng."},{"key":"ref_23","unstructured":"Zeng, H. (2017). Study on Monitoring and Evaluation Method of Population Cardiac Reserve Based on Heart Sound, Chongqing University."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"30033","DOI":"10.1109\/ACCESS.2019.2900446","article-title":"Research on Parallel Compressive Sensing and Application of Multi-channel Synchronous Acquisition of Heart Sound Signals","volume":"7","author":"Cheng","year":"2019","journal-title":"IEEE Access"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"148701","DOI":"10.7498\/aps.69.20200254","article-title":"Blood pressure estimation based on heart sound signals","volume":"69","author":"Cheng","year":"2020","journal-title":"Acta Phys. Sin."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"028501","DOI":"10.1063\/1.3156832","article-title":"Introduction to controversial topics in nonlinear science: Is the normal heart rate chaotic?","volume":"19","author":"Glass","year":"2009","journal-title":"Chaos"},{"key":"ref_27","first-page":"55","article-title":"Nonlinear dynamic analysis of heart sound signals based on chaos theory","volume":"31","author":"Ding","year":"2012","journal-title":"J. Vib. Shock"},{"key":"ref_28","first-page":"1121","article-title":"A study of lumped-parameter cardiovascular simulation model and heart sound mechanism","volume":"44","author":"Cheng","year":"2014","journal-title":"Sci. China"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/1\/181\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T07:54:50Z","timestamp":1760169290000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/1\/181"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12,28]]},"references-count":28,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,1]]}},"alternative-id":["s22010181"],"URL":"https:\/\/doi.org\/10.3390\/s22010181","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,12,28]]}}}