{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T17:21:15Z","timestamp":1793726475847,"version":"4.6.1"},"reference-count":25,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2021,12,28]],"date-time":"2021-12-28T00:00:00Z","timestamp":1640649600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100009888","name":"Tuscany Region","doi-asserted-by":"publisher","award":["7165_24-05-2017"],"award-info":[{"award-number":["7165_24-05-2017"]}],"id":[{"id":"10.13039\/501100009888","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Home-based rehabilitation is becoming a gold standard for patient who have undergone knee arthroplasty or full knee replacement, as it helps healthcare costs to be minimized. Nevertheless, there is a chance of increasing adverse health effects in case of home care, primarily due to the patients\u2019 lack of motivation and the doctors\u2019 difficulty in carrying out rigorous supervision. The development of devices to assess the efficient recovery of the operated joint is highly valued both for the patient, who feels encouraged to perform the proper number of activities, and for the doctor, who can track him\/her remotely. Accordingly, this paper introduces an interactive approach to angular range calculation of hip and knee joints based on the use of low-cost devices which can be operated at home. First, the patient\u2019s body posture is estimated using a 2D acquisition method. Subsequently, the 3D posture is evaluated by using the depth information coming from an RGB-D sensor. Preliminary results show that the proposed method effectively overcomes many limitations by fusing the results obtained by the state-of-the-art robust 2D pose estimation algorithms with the 3D data of depth cameras by allowing the patient to be correctly tracked during rehabilitation exercises.<\/jats:p>","DOI":"10.3390\/s22010184","type":"journal-article","created":{"date-parts":[[2021,12,29]],"date-time":"2021-12-29T02:31:27Z","timestamp":1640745087000},"page":"184","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["RGB-D-Based Method for Measuring the Angular Range of Hip and Knee Joints during Home Care Rehabilitation"],"prefix":"10.3390","volume":"22","author":[{"given":"Francesca","family":"Uccheddu","sequence":"first","affiliation":[{"name":"Dipartimento Ingegneria Industriale, Universit\u00e0 di Padova, Via Venezia 1, 35131 Padova, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6771-5981","authenticated-orcid":false,"given":"Rocco","family":"Furferi","sequence":"additional","affiliation":[{"name":"Dipartimento Ingegneria Industriale, Universit\u00e0 di Firenze, Via Santa Marta 3, 50100 Firenze, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7417-3487","authenticated-orcid":false,"given":"Lapo","family":"Governi","sequence":"additional","affiliation":[{"name":"Dipartimento Ingegneria Industriale, Universit\u00e0 di Firenze, Via Santa Marta 3, 50100 Firenze, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Monica","family":"Carfagni","sequence":"additional","affiliation":[{"name":"Dipartimento Ingegneria Industriale, Universit\u00e0 di Firenze, Via Santa Marta 3, 50100 Firenze, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2021,12,28]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Papalia, R., Zampogna, B., Torre, G., Papalia, G.F., Vorini, F., Bravi, M., Albo, E., De Vincentis, A., and Denaro, V. (2021). Preoperative and Perioperative Predictors of Length of Hospital Stay after Primary Total Hip Arthroplasty\u2014Our Experience on 743 Cases. J. Clin. Med., 10.","DOI":"10.3390\/jcm10215053"},{"key":"ref_2","first-page":"303","article-title":"Rehabilitation after total hip arthroplasty: A systematic review of controlled trials on physical exercise programs","volume":"45","author":"Vallero","year":"2009","journal-title":"Eur. J. Physiol. Rehabil. Med."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"26","DOI":"10.3109\/17453674.2013.874925","article-title":"Reduced short-term complications and mortality following enhanced recovery primary hip and knee arthroplasty: Results from 6000 consecutive procedures","volume":"85","author":"Khan","year":"2014","journal-title":"Acta Orthop."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Berg, U., W-Dahl, A., Nilsdotter, A., Naucl\u00e9r, E., Sundberg, M., and Rolfson, O. (2021). Fast-Track Programs in Total Hip and Knee Replacement at Swedish Hospitals\u2014Influence on 2-Year Risk of Revision and Mortality. J. Clin. Med., 10.","DOI":"10.3390\/jcm10081680"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Grzelecki, D., Marczak, D., Kwolek, K., Dudek, P., Tyrakowski, M., Olewnik, \u0141., Czubak-Wrzosek, M., and Kowalczewski, J. (2021). Shaft Fractures in Patients Requiring Primary or Revision Total Knee Arthroplasty Can Be Successfully Treated with Long-Stemmed Implants without Additional Fixation. J. Clin. Med., 10.","DOI":"10.3390\/jcm10214926"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Chatzitofis, A., Zarpalas, D., Kollias, S., and Daras, P. (2019). DeepMoCap: Deep Optical Motion Capture Using Multiple Depth Sensors and Retro-Reflectors. Sensors, 19.","DOI":"10.3390\/s19020282"},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Yasin, H., and Kr\u00fcger, B. (2021). An Efficient 3D Human Pose Retrieval and Reconstruction from 2D Image-Based Landmarks. Sensors, 21.","DOI":"10.3390\/s21072415"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Eynard, B., Nigrelli, V., Oliveri, S., Peris-Fajarnes, G., and Rizzuti, S. (2017). A RGB-D based instant body-scanning solution for compact box installation. Advances on Mechanics, Design Engineering and Manufacturing. Lecture Notes in Mechanical Engineering, Springer.","DOI":"10.1007\/978-3-319-45781-9"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Uccheddu, F., Governi, L., and Carfagni, M. (2019). A Preliminary 3D Depth Camera-Based System to Assist Home Physiotherapy Rehabilitation. International Conference on Design, Simulation, Manufacturing: The Innovation Exchange, Springer.","DOI":"10.1007\/978-3-030-31154-4_59"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"11258","DOI":"10.3390\/s150511258","article-title":"Estimation of Joint Forces and Moments for the In-Run and Take-Off in Ski Jumping Based on Measurements with Wearable Inertial Sensors","volume":"15","author":"Logar","year":"2015","journal-title":"Sensors"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"12410","DOI":"10.3390\/s150612410","article-title":"Real-Time Human Pose Estimation and Gesture Recognition from Depth Images Using Superpixels and SVM Classifier","volume":"15","author":"Kim","year":"2015","journal-title":"Sensors"},{"key":"ref_12","unstructured":"(2021, February 11). Nuitrack Full Body Skeletal Tracking Software\u2014Kinect Replacement for Android, Windows, Linux, iOS, Intel RealSense, Orbbec. Available online: https:\/\/nuitrack.com\/."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Cao, Z., Simon, T., Wei, S.E., and Shekh, Y. (2017, January 21\u201327). Realtime multi-person 2d pose estimation using part affinity fields. Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition, Honolulu, HI, USA.","DOI":"10.1109\/CVPR.2017.143"},{"key":"ref_14","unstructured":"Alexiadis, D.S., Kelly, P., Boubekeur, T., and Moussa, M.B. (December, January 28). Evaluating a dancer\u2019s performance using kinect-based skeleton tracking. Proceedings of the 19th ACM International Conference on MULTIMEDIA, Scottsdale, AZ, USA."},{"key":"ref_15","unstructured":"(2021, July 11). Intel Realsense SDK. Available online: https:\/\/www.intelrealsense.com\/developers\/."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Yahya, M., Shah, J., Kadir, K., Warsi, A., Khan, S., and Nasir, H. (2019, January 20\u201323). Accurate Shoulder Joint Angle Estimation Using Single RGB camera for Rehabilitation. Proceedings of the 2019 IEEE International Instrumentation and Measurement Technology Conference (I2MTC), Auckland, New Zealand.","DOI":"10.1109\/I2MTC.2019.8827104"},{"key":"ref_17","unstructured":"(2021, July 11). Neuronmocap. Available online: https:\/\/neuronmocap.com\/products\/perception_neuron."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Rudolf, A., Stjepanovi\u010d, Z., and Cupar, A. (2021). Study Regarding the Kinematic 3D Human-Body Model Intended for Simulation of Personalized Clothes for a Sitting Posture. Materials, 14.","DOI":"10.3390\/ma14185124"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1029","DOI":"10.1016\/j.jbiomech.2007.12.003","article-title":"Ambulatory measurement of 3D knee joint angle","volume":"41","author":"Favre","year":"2008","journal-title":"J. Biomech."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"6891","DOI":"10.3390\/s140406891","article-title":"IMU-Based Joint Angle Measurement for Gait Analysis","volume":"14","author":"Seel","year":"2014","journal-title":"Sensors"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Loellgen, H., Zupet, P., Bachl, N., and Debruyne, A. (2020). Physical Activity, Exercise Prescription for Health and Home-Based Rehabilitation. Sustainability, 12.","DOI":"10.3390\/su122410230"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Cudejko, T., Button, K., Willott, J., and Al-Amri, M. (2021). Applications of Wearable Technology in a Real-Life Setting in People with Knee Osteoarthritis: A Systematic Scoping Review. J. Clin. Med., 10.","DOI":"10.3390\/jcm10235645"},{"key":"ref_23","first-page":"1","article-title":"Managing osteoarthritis pain with smart technology: A narrative review","volume":"5","author":"Johnson","year":"2021","journal-title":"Rheumatol. Adv. Pract."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Vourganas, I., Stankovic, V., Stankovic, L., and Michala, A.L. (2020). Evaluation of Home-Based Rehabilitation Sensing Systems with Respect to Standardised Clinical Tests. Sensors, 20.","DOI":"10.3390\/s20010026"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1111\/jpim.12176","article-title":"PERSPECTIVE: Older Adults\u2019 Adoption of Technology: An Integrated Approach to Identifying Determinants and Barriers","volume":"32","author":"Lee","year":"2014","journal-title":"J. Prod. Innov. Manag."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/1\/184\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T07:55:00Z","timestamp":1760169300000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/1\/184"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12,28]]},"references-count":25,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,1]]}},"alternative-id":["s22010184"],"URL":"https:\/\/doi.org\/10.3390\/s22010184","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,12,28]]}}}