{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T00:04:23Z","timestamp":1788912263027,"version":"build-2803163510"},"reference-count":26,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2022,1,10]],"date-time":"2022-01-10T00:00:00Z","timestamp":1641772800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100002855","name":"Ministry of Science and Technology of the People's Republic of China","doi-asserted-by":"publisher","award":["MOST 109-2637-E-167-001 -"],"award-info":[{"award-number":["MOST 109-2637-E-167-001 -"]}],"id":[{"id":"10.13039\/501100002855","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A variety of feature extraction and classification approaches have been proposed using electrocardiogram (ECG) and ECG-derived signals for improving the performance of detecting apnea events and diagnosing patients with obstructive sleep apnea (OSA). The purpose of this study is to further evaluate whether the reduction of lower frequency P and T waves can increase the accuracy of the detection of apnea events. This study proposed filter bank decomposition to decompose the ECG signal into 15 subband signals, and a one-dimensional (1D) convolutional neural network (CNN) model independently cooperating with each subband to extract and classify the features of the given subband signal. One-minute ECG signals obtained from the MIT PhysioNet Apnea-ECG database were used to train the CNN models and test the accuracy of detecting apnea events for different subbands. The results show that the use of the newly selected subject-independent datasets can avoid the overestimation of the accuracy of the apnea event detection and can test the difference in the accuracy of different subbands. The frequency band of 31.25\u201337.5 Hz can achieve 100% per-recording accuracy with 85.8% per-minute accuracy using the newly selected subject-independent datasets and is recommended as a promising subband of ECG signals that can cooperate with the proposed 1D CNN model for the diagnosis of OSA.<\/jats:p>","DOI":"10.3390\/s22020510","type":"journal-article","created":{"date-parts":[[2022,1,10]],"date-time":"2022-01-10T22:03:13Z","timestamp":1641852193000},"page":"510","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":27,"title":["Contribution of Different Subbands of ECG in Sleep Apnea Detection Evaluated Using Filter Bank Decomposition and a Convolutional Neural Network"],"prefix":"10.3390","volume":"22","author":[{"given":"Cheng-Yu","family":"Yeh","sequence":"first","affiliation":[{"name":"Department of Electrical Engineering, National Chin-Yi University of Technology, Taichung 411, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hung-Yu","family":"Chang","sequence":"additional","affiliation":[{"name":"Heart Center, Cheng Hsin General Hospital, Taipei 112, Taiwan"},{"name":"Faculty of Medicine, School of Medicine, National Yang Ming Chiao Tung University, Taipei 112, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiy-Yao","family":"Hu","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, National Chin-Yi University of Technology, Taichung 411, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5604-9845","authenticated-orcid":false,"given":"Chun-Cheng","family":"Lin","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, National Chin-Yi University of Technology, Taichung 411, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,1,10]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1016\/j.ejim.2012.05.013","article-title":"Obstructive sleep apnea syndrome","volume":"23","author":"Mannarino","year":"2012","journal-title":"Eur. J. Intern. Med."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"841","DOI":"10.1016\/j.jacc.2016.11.069","article-title":"Sleep apnea: Types, mechanisms, and clinical cardiovascular consequences","volume":"69","author":"Javaheri","year":"2017","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1093\/bja\/aes465","article-title":"Proportion of surgical patients with undiagnosed obstructive sleep apnoea","volume":"110","author":"Singh","year":"2013","journal-title":"Br. J. Anaesth."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1093\/sleep\/32.2.150","article-title":"The new AASM criteria for scoring hypopneas: Impact on the apnea hypopnea index","volume":"32","author":"Ruehland","year":"2009","journal-title":"Sleep"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"2666","DOI":"10.1109\/JSEN.2013.2257742","article-title":"Empirical mode decomposition vs. wavelet decomposition for the extraction of respiratory signal from single-channel ECG: A comparison","volume":"13","author":"Labate","year":"2013","journal-title":"IEEE Sens. J."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"2072","DOI":"10.1007\/s10439-014-1073-x","article-title":"Electrocardiogram derived respiratory rate from QRS slopes and R-wave angle","volume":"42","author":"Alcaine","year":"2014","journal-title":"Ann. Biomed. Eng."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1059","DOI":"10.1109\/JBHI.2017.2734074","article-title":"Variational mode extraction: A new efficient method to derive respiratory signals from ECG","volume":"22","author":"Nazari","year":"2018","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1161\/CIRCEP.110.958009","article-title":"Screening for Obstructive Sleep Apnea by Cyclic Variation of Heart Rate","volume":"4","author":"Hayano","year":"2011","journal-title":"Circ. Arrhythm. Electrophysiol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/j.neucom.2016.12.062","article-title":"An expert system for automated identification of obstructive sleep apnea from single-lead ECG using random under sampling boosting","volume":"235","author":"Hassan","year":"2017","journal-title":"Neurocomputing"},{"key":"ref_10","first-page":"2875","article-title":"Sleep apnea classification using ECG-signal wavelet-PCA features","volume":"24","author":"Rachim","year":"2014","journal-title":"Biomed. Mater. Eng."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/j.compbiomed.2018.06.011","article-title":"Application of an optimal class of antisymmetric wavelet filter banks for obstructive sleep apnea diagnosis using ECG signals","volume":"100","author":"Sharma","year":"2018","journal-title":"Comput. Biol. Med."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"100170","DOI":"10.1016\/j.imu.2019.100170","article-title":"A new approach to identify obstructive sleep apnea using an optimal orthogonal wavelet filter bank with ECG signals","volume":"16","author":"Sharma","year":"2019","journal-title":"Inform. Med. Unlocked"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Chang, H.Y., Yeh, C.Y., Lee, C.T., and Lin, C.C. (2020). A sleep apnea detection system based on a one-dimensional deep convolution neural network model using single-lead electrocardiogram. Sensors, 20.","DOI":"10.3390\/s20154157"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"e7731","DOI":"10.7717\/peerj.7731","article-title":"Sleep apnea detection from a single-lead ECG signal with automatic feature-extraction through a modified LeNet-5 convolutional neural network","volume":"7","author":"Wang","year":"2019","journal-title":"PeerJ"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.cmpb.2019.05.002","article-title":"A RR interval based automated apnea detection approach using residual network","volume":"176","author":"Wang","year":"2019","journal-title":"Comput. Methods Programs Biomed."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"015026","DOI":"10.1088\/2057-1976\/ab68e9","article-title":"Sleep apnea detection from ECG using variational mode decomposition","volume":"6","author":"Sharma","year":"2020","journal-title":"Biomed. Phys. Eng. Express"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"105568","DOI":"10.1016\/j.asoc.2019.105568","article-title":"Towards an accurate sleep apnea detection based on ECG signal: The quintessential of a wise feature selection","volume":"83","author":"Pinho","year":"2019","journal-title":"Appl. Soft Comput."},{"key":"ref_18","first-page":"255","article-title":"The apnea-ECG database","volume":"27","author":"Penzel","year":"2000","journal-title":"Comput. Cardiol."},{"key":"ref_19","first-page":"e215","article-title":"PhysioBank, PhysioToolkit, and PhysioNet: Components of a new research resource for complex physiologic signals","volume":"101","author":"Goldberger","year":"2003","journal-title":"Circulation"},{"key":"ref_20","unstructured":"(2021, August 21). Signal Processing Toolbox-MATLAB. Available online: https:\/\/www.mathworks.com\/products\/signal.html."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"He, K., Zhang, X., Ren, S., and Sun, J. (2015). Delving Deep into Rectifiers: Surpassing Human-Level Performance on ImageNet Classification. arXiv.","DOI":"10.1109\/ICCV.2015.123"},{"key":"ref_22","unstructured":"Kingma, P.D., and Ba, J.L. (2017). Adam: A Method for Stochastic Optimization. arXiv."},{"key":"ref_23","first-page":"557","article-title":"Selection and interpretation of diagnostic tests and procedures. Principles and applications","volume":"94","author":"Griner","year":"1981","journal-title":"Ann. Intern. Med."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1532","DOI":"10.1109\/TBME.2015.2498199","article-title":"An obstructive sleep apnea detection approach using a discriminative hidden markov model from ECG signals","volume":"63","author":"Song","year":"2016","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1016\/j.neucom.2018.03.011","article-title":"A method to detect sleep apnea based on deep neural network and hidden Markov model using single-lead ECG signal","volume":"294","author":"Li","year":"2018","journal-title":"Neurocomputing"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"762","DOI":"10.1109\/TBCAS.2018.2824659","article-title":"Online obstructive sleep apnea detection on medical wearable sensors","volume":"12","author":"Surrel","year":"2018","journal-title":"IEEE Trans. Biomed. Circuits Syst."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/2\/510\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,13]],"date-time":"2025-10-13T13:27:14Z","timestamp":1760362034000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/2\/510"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,10]]},"references-count":26,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2022,1]]}},"alternative-id":["s22020510"],"URL":"https:\/\/doi.org\/10.3390\/s22020510","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,10]]}}}