{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,27]],"date-time":"2026-09-27T08:00:24Z","timestamp":1790496024603,"version":"4.1.0"},"reference-count":30,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2022,2,18]],"date-time":"2022-02-18T00:00:00Z","timestamp":1645142400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001826","name":"Netherlands Organisation for Health Research and Development","doi-asserted-by":"publisher","award":["Technology for Sustainable Healthcare 2017"],"award-info":[{"award-number":["Technology for Sustainable Healthcare 2017"]}],"id":[{"id":"10.13039\/501100001826","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The success of total hip arthroplasty depends on the experience of the surgeon, and one of the ways the surgeon currently determines the final implant insertion depth is to listen to the change in audible pitch of the hammering sound. We investigated the use of vibration emissions as a novel method for insertion quality assessment. A non-invasive contact microphone-based measurement system for insertion depth estimation, fixation and fracture detection was developed using a simplified in vitro bone\/implant (n = 5). A total of 2583 audio recordings were analyzed in vitro to obtain energy spectral density functions. Out of the four main resonant peaks under in vitro conditions, broach insertion depth statistically correlates to increasing 3rd and 4th peak frequencies. Degree of fixation was also observed as higher goodness of fit (0.26\u20130.78 vs. 0.12\u20130.51 between two broach sizes, the latter undersized). Finally, however, the moment of fracture could not be predicted. A cadaveric in situ pilot study suggests comparable resonant frequencies in the same order of magnitudes with the bone model. Further understanding of the signal patterns are needed for an early warning system diagnostic system for imminent fractures, bone damage, improving accuracy and quality of future procedures.<\/jats:p>","DOI":"10.3390\/s22041609","type":"journal-article","created":{"date-parts":[[2022,2,21]],"date-time":"2022-02-21T08:34:47Z","timestamp":1645432487000},"page":"1609","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Using Acoustic Vibrations as a Method for Implant Insertion Assessment in Total Hip Arthroplasty"],"prefix":"10.3390","volume":"22","author":[{"given":"Jonathan C. J.","family":"Wei","sequence":"first","affiliation":[{"name":"Department of BioMechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, 2628 CD Delft, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9273-4073","authenticated-orcid":false,"given":"Willem H. A.","family":"Crezee","sequence":"additional","affiliation":[{"name":"Department of BioMechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, 2628 CD Delft, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hilda","family":"Jongeneel","sequence":"additional","affiliation":[{"name":"Department of BioMechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, 2628 CD Delft, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tobias S. A.","family":"De Haas","sequence":"additional","affiliation":[{"name":"Department of BioMechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, 2628 CD Delft, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wesley L. A.","family":"Kool","sequence":"additional","affiliation":[{"name":"Department of BioMechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, 2628 CD Delft, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bryan J.","family":"Blaauw","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Elkerliek Hospital, 5707 HA Helmond, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3951-2129","authenticated-orcid":false,"given":"Jenny","family":"Dankelman","sequence":"additional","affiliation":[{"name":"Department of BioMechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, 2628 CD Delft, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tim","family":"Horeman","sequence":"additional","affiliation":[{"name":"Department of BioMechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, 2628 CD Delft, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,2,18]]},"reference":[{"key":"ref_1","unstructured":"Landelijke Registratie Orthopedische Implantaten (2022, February 04). Number of Registered Hip Arthroplasties Per Year of Surgery (2007\u20132018) in the Lroi in April 2019. Available online: http:\/\/www.lroi-rapportage.nl\/2-magazines-op-home-2019-numbers-registered-procedures-2007-2018."},{"key":"ref_2","unstructured":"(2022, February 04). Monitoring Femoral Component Insertion in Cementless Total Hip Arthroplasty. Available online: http:\/\/citeseerx.ist.psu.edu\/viewdoc\/download?doi=10.1.1.506.6517&rep=rep1&type=pdf."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1177\/0954411912462813","article-title":"Spectral analysis of the sound produced during femoral broaching and implant insertion in uncemented total hip arthroplasty","volume":"227","author":"Whitwell","year":"2013","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1186\/1749-799X-4-10","article-title":"In vivo evaluation of a vibration analysis technique for the per-operative monitoring of the fixation of hip prostheses","volume":"4","author":"Pastrav","year":"2009","journal-title":"J. Orthop. Surg. Res."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s00590-012-1139-0","article-title":"The sound of orthopaedic surgery\u2014the application of acoustic emission technology in orthopaedic surgery: A review","volume":"24","author":"Rashid","year":"2014","journal-title":"Eur. J. Orthop. Surg. Traumatol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1016\/j.bspc.2016.12.011","article-title":"Development and validation of an acoustic emission device to measure wear in total hip replacements in-vitro and in-vivo","volume":"33","author":"Patrick","year":"2017","journal-title":"Biomed. Signal Processing Control."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1016\/S0268-0033(03)00051-2","article-title":"How much can a vibrational diagnostic tool reveal in total hip arthroplasty loosening?","volume":"18","author":"Qi","year":"2003","journal-title":"Clin. Biomech."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1016\/j.ijmecsci.2018.05.051","article-title":"Vibro-acoustic and non-linear analysis of cadaveric femoral bone impaction in cavity preparations","volume":"144","author":"Oberst","year":"2018","journal-title":"Int. J. Mech. Sci."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1016\/j.conengprac.2016.09.013","article-title":"Signal processing and event detection of hip implant acoustic emissions","volume":"58","author":"Rodgers","year":"2017","journal-title":"Control Eng. Pract."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1080\/03091902.2017.1411986","article-title":"Acoustic emission technology can warn of impending iatrogenic femur fracture during femoral canal preparation for uncemented hip replacement. a cadaveric animal bone study","volume":"42","author":"Pechon","year":"2018","journal-title":"J. Med. Eng. Technol."},{"key":"ref_11","unstructured":"Gueiral, N., and Nogueira, E. (2011). Recent Advances in Arthroplasty, InTechOpen."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1016\/j.medengphy.2010.10.025","article-title":"Realtime monitoring of progressive damage during loading of a simplified total hip stem construct using embedded acoustic emission sensors","volume":"33","author":"Mavrogordato","year":"2011","journal-title":"Med. Eng. Phys."},{"key":"ref_13","first-page":"576","article-title":"Per-operative vibration analysis: A valuable tool for defining correct stem insertion: Preliminary report","volume":"10","author":"Mulier","year":"2008","journal-title":"Ortop. Traumatol. Rehabil."},{"key":"ref_14","unstructured":"Shibanuma, N., Hata, Y., Nishiyama, T., Fujishiro, T., Tateishi, H., and Kurosaka, M. (2008, January 2\u20135). Determination of total hip arthroplasty stem stability by intraoperative measurement using an acoustic testing technique. Proceedings of the 54th Annual Meeting of the Orthopaedic Research Society, San Francisco, CA, USA."},{"key":"ref_15","unstructured":"Poudrel, A., Lomami, H., Rosi, G., Dubory, A., Flouzat-Lachaniette, C., and Haiat, G. (2022, January 19). Estimation of Cementless Femoral Stem Stability Using an Impact Hammer. Available online: https:\/\/hal.inria.fr\/hal-03235369."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1109\/JTEHM.2021.3128276","article-title":"Development of an Instrument to Assess the Stability of Cementless Femoral Implants Using Vibration Analysis During Total Hip Arthroplasty","volume":"9","author":"Leuridan","year":"2021","journal-title":"IEEE J. Transl. Eng. Health Med."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Michel, A., Bosc, R., Meningaud, J., Hernigou, P., and Haiat, G. (2016). Assessing the Acetabular Cup Implant Primary Stability by Impact Analyses: A Cadaveric Study. PLoS ONE, 11.","DOI":"10.1371\/journal.pone.0166778"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/j.medengphy.2017.07.006","article-title":"Development of an acoustic measurement protocol to monitor acetabular implant fixation in cementless total hip Arthroplasty: A preliminary study","volume":"49","author":"Goossens","year":"2017","journal-title":"Med. Eng. Phys."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1164","DOI":"10.1002\/jor.24837","article-title":"Acoustic analysis to monitor implant seating and early detect fractures in cementless THA: An in vivo study","volume":"39","author":"Goossens","year":"2020","journal-title":"J. Orthop. Res."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1051\/sicotj\/2016049","article-title":"Acoustic pattern evaluation during cementless hip arthroplasty surgery may be a new method for predicting complications","volume":"3","author":"Morohashi","year":"2017","journal-title":"SICOTJ"},{"key":"ref_21","unstructured":"Kutz, M. (2003). Standard Handbook of Biomedical Engineering and Design, McGraw-Hill."},{"key":"ref_22","unstructured":"Crisman, A., Yoder, N., McCuskey, M., Meneghini, R., and Cornwell, P. (2022, February 04). Femoral Component Insertion Monitoring Using Human Cadaveric Specimens. Conference Proceedings of the Society for Experimental Mechanics Series, 01. Available online: https:\/\/citeseerx.ist.psu.edu\/viewdoc\/download?doi=10.1.1.529.3840&rep=rep1&type=pdf."},{"key":"ref_23","unstructured":"Purves, D., Augustine, G.J., Fitzpatrick, D., Katz, L., LaMantia, A.-S., McNamara, J., and Mark Williams, S. (2022, February 04). The Audible Spectrum, Neuroscience, Available online: https:\/\/www.ncbi.nlm.nih.gov\/books\/NBK10924."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"O\u2019Connor, J., Borges, L., Duda, F., and da Cruz, A. (2015, January 21\u201325). Growth and reabsorption in biological tissues. Proceedings of the XXXVI Ibero-Latin American Congress on Computational Methods in Engineering (cilamce2015), Rio de Janiero, Brazil.","DOI":"10.20906\/CPS\/CILAMCE2015-0427"},{"key":"ref_25","unstructured":"(2022, February 04). CES EduPack Software. Available online: https:\/\/www.ansys.com\/products\/materials\/granta-edupack."},{"key":"ref_26","unstructured":"(2022, February 04). Eigenfrequency Analysis. Available online: https:\/\/www.comsol.com\/multiphysics\/eigenfrequency-analysis."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Blevins, R.D. (2015). Natural Frequency of Beams. Formulas for Dynamics, Acoustics and Vibration, John Wiley & Sons.","DOI":"10.1002\/9781119038122"},{"key":"ref_28","unstructured":"(2022, February 04). Actis Surgical Technique. Available online: http:\/\/synthes.vo.llnwd.net\/o16\/LLNWMB8\/US%20Mobile\/Synthes%20North%20America\/Product%20Support%20Materials\/Technique%20Guides\/Actis%20Surgical%20Technique%20March%202018.pdf."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1016\/8756-3282(89)90074-4","article-title":"Sex Differences in Age-Related Loss of Vertebral Trabecular Bone Mass and Structure\u2014Biomechanical Consequences","volume":"10","author":"Mosekilde","year":"1989","journal-title":"Bone"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"e176233","DOI":"10.1001\/jamasurg.2017.6233","article-title":"Understanding costs of care in the operating room","volume":"153","author":"Childers","year":"2018","journal-title":"JAMA Surg."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/4\/1609\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T22:22:36Z","timestamp":1760134956000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/4\/1609"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,18]]},"references-count":30,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2022,2]]}},"alternative-id":["s22041609"],"URL":"https:\/\/doi.org\/10.3390\/s22041609","relation":{"has-preprint":[{"id-type":"doi","id":"10.20944\/preprints202112.0019.v1","asserted-by":"object"}]},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,18]]}}}