{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,18]],"date-time":"2026-06-18T13:48:59Z","timestamp":1781790539120,"version":"3.54.5"},"reference-count":43,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2022,2,25]],"date-time":"2022-02-25T00:00:00Z","timestamp":1645747200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"the National Key Research and Development Program of China","award":["2019YFB2204903"],"award-info":[{"award-number":["2019YFB2204903"]}]},{"name":"the Science and Technology Program from State Grid Corporation of China","award":["No.5700-201955318A-0-0-00"],"award-info":[{"award-number":["No.5700-201955318A-0-0-00"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Here, we report a novel technology for the fabrication of copper-electroplating-modified liquid metal microelectrodes. This technology overcomes the complexity of the traditional fabrication of sidewall solid metal electrodes and successfully fabricates a pair of tiny stable solid-contact microelectrodes on both sidewalls of a microchannel. Meanwhile, this technology also addresses the instability of liquid metal electrodes when directly contacted with sample solutions. The fabrication of this microelectrode depends on controllable microelectroplating of copper onto the gallium electrode by designing a microelectrolyte cell in a microfluidic chip. Using this technology, we successfully fabricate various microelectrodes with different microspacings (from 10 \u03bcm to 40 \u03bcm), which were effectively used for capacitive sensing, including droplet detection and oil particle counting.<\/jats:p>","DOI":"10.3390\/s22051820","type":"journal-article","created":{"date-parts":[[2022,2,27]],"date-time":"2022-02-27T20:48:33Z","timestamp":1645994913000},"page":"1820","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Copper-Electroplating-Modified Liquid Metal Microfluidic Electrodes"],"prefix":"10.3390","volume":"22","author":[{"given":"Jiahao","family":"Gong","sequence":"first","affiliation":[{"name":"Liquid Metal and Cryogenic Biomedical Research Center, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, 29 Zhongguancun East Road, Haidian District, Beijing 100190, China"},{"name":"CAS Key Laboratory of Bio-Inspired Materials and Interfacial Science, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, 29 Zhongguancun East Road, Haidian District, Beijing 100190, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bingxin","family":"Liu","sequence":"additional","affiliation":[{"name":"Liquid Metal and Cryogenic Biomedical Research Center, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, 29 Zhongguancun East Road, Haidian District, Beijing 100190, China"},{"name":"University of Chinese Academy of Sciences, 19 Yuquan Road, Shijingshan District, Beijing 100039, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pan","family":"Zhang","sequence":"additional","affiliation":[{"name":"Liquid Metal and Cryogenic Biomedical Research Center, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, 29 Zhongguancun East Road, Haidian District, Beijing 100190, China"},{"name":"University of Chinese Academy of Sciences, 19 Yuquan Road, Shijingshan District, Beijing 100039, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huimin","family":"Zhang","sequence":"additional","affiliation":[{"name":"Liquid Metal and Cryogenic Biomedical Research Center, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, 29 Zhongguancun East Road, Haidian District, Beijing 100190, China"},{"name":"University of Chinese Academy of Sciences, 19 Yuquan Road, Shijingshan District, Beijing 100039, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8015-0791","authenticated-orcid":false,"given":"Lin","family":"Gui","sequence":"additional","affiliation":[{"name":"Liquid Metal and Cryogenic Biomedical Research Center, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, 29 Zhongguancun East Road, Haidian District, Beijing 100190, China"},{"name":"University of Chinese Academy of Sciences, 19 Yuquan Road, Shijingshan District, Beijing 100039, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,2,25]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"2046","DOI":"10.1039\/b815152k","article-title":"An integrated microfluidic platform for sensitive and rapid detection of biological toxins","volume":"8","author":"Meagher","year":"2008","journal-title":"Lab Chip"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1898","DOI":"10.1039\/C4LC01459F","article-title":"A lab-on-a-chip system with integrated sample preparation and loop-mediated isothermal amplification for rapid and quantitative detection of Salmonella spp. in food samples","volume":"15","author":"Sun","year":"2015","journal-title":"Lab Chip"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"2348","DOI":"10.1039\/C8LC00408K","article-title":"Microfabricated devices for oral drug delivery","volume":"18","author":"Nielsen","year":"2018","journal-title":"Lab Chip"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"2905","DOI":"10.1039\/C9LC00527G","article-title":"Biodegradable microcontainers\u2014Towards real life applications of microfabricated systems for oral drug delivery","volume":"19","author":"Abid","year":"2019","journal-title":"Lab Chip"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1373","DOI":"10.1039\/C7LC00016B","article-title":"Recent advances in the design of polymeric microneedles for transdermal drug delivery and biosensing","volume":"17","author":"Wang","year":"2017","journal-title":"Lab Chip"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"5218","DOI":"10.1039\/c2lc40921f","article-title":"Droplet Microarray: Facile formation of arrays of microdroplets and hydrogel micropads for cell screening applications","volume":"12","author":"Ueda","year":"2012","journal-title":"Lab Chip"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"3733","DOI":"10.1039\/C8LC00818C","article-title":"Functional TCR T cell screening using single-cell droplet microfluidics","volume":"18","author":"Segaliny","year":"2018","journal-title":"Lab Chip"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1696","DOI":"10.1039\/b711513j","article-title":"Cell-based high content screening using an integrated microfluidic device","volume":"7","author":"Ye","year":"2007","journal-title":"Lab Chip"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"962","DOI":"10.1039\/c2lc41060e","article-title":"Electrostatic charging and control of droplets in microfluidic devices","volume":"13","author":"Zhou","year":"2013","journal-title":"Lab Chip"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"3228","DOI":"10.1039\/b909158k","article-title":"A light-induced dielectrophoretic droplet manipulation platform","volume":"9","author":"Park","year":"2009","journal-title":"Lab Chip"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1744","DOI":"10.1039\/C3EE44044C","article-title":"Microfluidic fuel cells on paper: Meeting the power needs of next generation lateral flow devices","volume":"7","author":"Esquivel","year":"2014","journal-title":"Energy Environ. Sci."},{"key":"ref_12","first-page":"65","article-title":"Development status of microfluidic fuel cell","volume":"35","author":"Zhang","year":"2016","journal-title":"Chem. Ind. Eng. Prog."},{"key":"ref_13","unstructured":"Ji, X., Pan, J., and Zhou, J. (2016, January 25\u201328). Dielectrophoretic microfluidic chip with 3D vertical side-wall electrodes. Proceedings of the 13th IEEE International Conference on Solid-State and Integrated-Circuit Technology (ICSICT), Hangzhou, China."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.jelechem.2014.06.006","article-title":"Selective deposition of chemically-bonded gold electrodes onto PDMS microchannel side walls","volume":"727","author":"Kadilak","year":"2014","journal-title":"J. Electroanal. Chem."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"4493","DOI":"10.1142\/S0217979206041574","article-title":"Fabrication of microchannel with electrodes on side wall","volume":"20","author":"Kang","year":"2006","journal-title":"Int. J. Mod. Phys. B"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1016\/j.talanta.2019.05.081","article-title":"Electrochemical paper-based microfluidic device for high throughput multiplexed analysis","volume":"203","author":"Fava","year":"2019","journal-title":"Talanta"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1016\/j.bios.2013.07.025","article-title":"Microfluidic chip integrated with flexible PDMS-based electrochemical cytosensor for dynamic analysis of drug-induced apoptosis on HeLa cells","volume":"51","author":"Cao","year":"2014","journal-title":"Biosens. Bioelectron."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"e1701629","DOI":"10.1126\/sciadv.1701629","article-title":"Skin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring","volume":"3","author":"Chen","year":"2017","journal-title":"Sci. Adv."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1039\/C4LC00593G","article-title":"Electrical cell-substrate impedance sensing with field-effect transistors is able to unravel cellular adhesion and detachment processes on a single cell level","volume":"15","author":"Susloparova","year":"2015","journal-title":"Lab Chip"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1073","DOI":"10.1039\/D0LC00937G","article-title":"Digital electrical impedance analysis for single bacterium sensing and antimicrobial susceptibility testing","volume":"21","author":"Scherer","year":"2021","journal-title":"Lab Chip"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"496","DOI":"10.1039\/C9LC00995G","article-title":"Liquid metal electrode-enabled flexible microdroplet sensor","volume":"20","author":"Zhang","year":"2020","journal-title":"Lab Chip"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Zuo, Z., Wang, K., Gao, L., Ho, V., Mao, H., and Qian, D. (2019). A Novel Mass-Producible Capacitive Sensor with Fully Symmetric 3D Structure and Microfluidics for Cells Detection. Sensors, 19.","DOI":"10.3390\/s19020325"},{"key":"ref_23","unstructured":"Ali, M.M., Narakathu, B.B., Emamian, S., Chlaihawi, A.A., Aljanabi, F., Maddipatla, D., Bazuin, B.J., and Atashbar, M.Z. (November, January 30). Eutectic Ga-In Liquid Metal Based Flexible Capacitive Pressure Sensor. Proceedings of the 15th IEEE Sensors Conference, Orlando, FL, USA."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"5376","DOI":"10.1109\/TIE.2020.2988237","article-title":"An Impedance Debris Sensor Based on a High-Gradient Magnetic Field for High Sensitivity and High Throughput","volume":"68","author":"Shi","year":"2021","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1039\/b917719a","article-title":"3-dimensional electrode patterning within a microfluidic channel using metal ion implantation","volume":"10","author":"Choi","year":"2010","journal-title":"Lab Chip"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1109\/JMEMS.2006.889530","article-title":"Side-Wall Vertical Electrodes for Lateral Field Microfluidic Applications","volume":"16","author":"Wang","year":"2007","journal-title":"J. Microelectromech. Syst."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1039\/b717416k","article-title":"Model based design of a microfluidic mixer driven by induced charge electroosmosis","volume":"8","author":"Harnett","year":"2008","journal-title":"Lab Chip"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"115012","DOI":"10.1088\/0960-1317\/22\/11\/115012","article-title":"Design and demonstration of a novel micro-Coulter counter utilizing liquid metal electrodes","volume":"22","author":"Richards","year":"2012","journal-title":"J. Micromech. Microeng."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Gao, M., and Gui, L. (2016). Development of a Multi-Stage Electroosmotic Flow Pump Using Liquid Metal Electrodes. Micromachines, 7.","DOI":"10.3390\/mi7090165"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1039\/c0lc00501k","article-title":"Inherently aligned microfluidic electrodes composed of liquid metal","volume":"11","author":"So","year":"2011","journal-title":"Lab Chip"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1007\/s10404-012-1068-6","article-title":"A novel method to construct 3D electrodes at the sidewall of microfluidic channel","volume":"14","author":"Li","year":"2013","journal-title":"Microfluid. Nanofluid."},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Wang, Q., Gao, M., Zhang, L., Deng, Z., and Gui, L. (2019). A Handy Flexible Micro-Thermocouple Using Low-Melting-Point Metal Alloys. Sensors, 19.","DOI":"10.3390\/s19020314"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1295","DOI":"10.1109\/TCPMT.2016.2573161","article-title":"3-D In-Bi-Sn Electrodes for Lab-on-PCB Cell Sorting","volume":"6","author":"Luo","year":"2016","journal-title":"IEEE Trans. Compon. Packag. Manuf. Technol."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"D3058","DOI":"10.1149\/2.0081901jes","article-title":"Observation of the Behavior of Additives in Copper Electroplating Using a Microfluidic Device","volume":"166","author":"Akita","year":"2018","journal-title":"J. Electrochem. Soc."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1049\/mnl.2018.5113","article-title":"Development and characterisation of electroplating silver\/silver chloride modified microelectrode arrays","volume":"14","author":"Bao","year":"2019","journal-title":"Micro Nano Lett."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"C559","DOI":"10.1149\/1.1773732","article-title":"Microelectroplating Silver on Sharp Edges toward the Fabrication of Solid-State Nanopores","volume":"151","author":"Polk","year":"2004","journal-title":"J. Electrochem. Soc."},{"key":"ref_37","first-page":"264","article-title":"Comparison Between Micro-chemical Etching and Microelectroplating Processes for Preparing Metal Mold of Microfluidic Chip","volume":"27","author":"Zheng","year":"2015","journal-title":"Corros. Sci. Prot. Technol."},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"He, Q., Chen, G., Chen, X., and Yao, C. (2009, January 20\u201324). Application of Oil Analysis to the Condition Monitoring of Large Engineering Machinery. Proceedings of the 8th International Conference on Reliability, Maintainability and Safety (ICRMS 2009), Chengdu, China.","DOI":"10.1109\/ICRMS.2009.5270033"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"136577","DOI":"10.1016\/j.cplett.2019.07.005","article-title":"Impact of metal particle size on partial discharge characteristics of moving metal particles in transformer oil","volume":"731","author":"Ma","year":"2019","journal-title":"Chem. Phys. Lett."},{"key":"ref_40","unstructured":"Wang, Y., Zhang, M., and Liu, D. (2012, January 23\u201325). A Compact On-line Particle Counter Sensor for Hydraulic Oil Contamination Detection. Proceedings of the 3rd International Conference on Mechanical and Electronics Engineering (ICMEE 2011), Hefei, China."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"1693","DOI":"10.1007\/s00170-017-0833-9","article-title":"Active control of hydraulic oil contamination to extend the service life of aviation hydraulic system","volume":"96","author":"Zhang","year":"2018","journal-title":"Int. J. Adv. Manuf. Technol."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"2067","DOI":"10.1109\/JSEN.2020.3016000","article-title":"Inductive-Capacitive Coulter Counting: Detection and Differentiation of Multi-Contaminants in Hydraulic Oil Using a Microfluidic Sensor","volume":"21","author":"Shi","year":"2021","journal-title":"IEEE Sens. J."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"016105","DOI":"10.1063\/1.3072665","article-title":"A microfluidic Coulter counting device for metal wear detection in lubrication oil","volume":"80","author":"Murali","year":"2009","journal-title":"Rev. Sci. Instrum."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/5\/1820\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T22:27:18Z","timestamp":1760135238000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/5\/1820"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,25]]},"references-count":43,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2022,3]]}},"alternative-id":["s22051820"],"URL":"https:\/\/doi.org\/10.3390\/s22051820","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,25]]}}}