{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,5]],"date-time":"2025-11-05T06:47:29Z","timestamp":1762325249217,"version":"build-2065373602"},"reference-count":16,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2022,3,16]],"date-time":"2022-03-16T00:00:00Z","timestamp":1647388800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"General nuclear safety technology","award":["xxx080202"],"award-info":[{"award-number":["xxx080202"]}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["11905102"],"award-info":[{"award-number":["11905102"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Natural Science Foundation of Hunan Province","award":["2020JJ5499"],"award-info":[{"award-number":["2020JJ5499"]}]},{"DOI":"10.13039\/100009377","name":"Education Department of Hunan Province","doi-asserted-by":"publisher","award":["18B268"],"award-info":[{"award-number":["18B268"]}],"id":[{"id":"10.13039\/100009377","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Herein, we report the \u03b3-ray ionizing radiation response of a commercial monolithic active-pixel sensor (MAPS) camera under strong-dose-rate irradiation with an online detection and monitoring system for strong radiation conditions. We present the first results of the distribution of three types of MAPS camera and establish a linear relationship between the average response signal and radiation dose rate in the strong-dose-rate range. There is an obvious response signal in the video frames when the camera module parameters are set to automatic, but the linear response is very poor. However, the fixed image parameters are not good at adapting to the changes of the environment and affect the quality of the video frames. A dual module online radiation detection and monitoring probe was made to carry out effective video monitoring and radiation detection at the same time. The measurement results show that the dose rate detection error is less than 5% with a dose rate in the range of 60 to 425 Gy\/h, and the visible light image does not have obvious distortion, deformation, or color shift due to the interference of the radiation response event and radiation damage. Hence, the system test results show that it can be used for online detection and monitoring in a strong radiation environment.<\/jats:p>","DOI":"10.3390\/s22062279","type":"journal-article","created":{"date-parts":[[2022,3,16]],"date-time":"2022-03-16T03:36:23Z","timestamp":1647401783000},"page":"2279","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Strong Radiation Field Online Detection and Monitoring System with Camera"],"prefix":"10.3390","volume":"22","author":[{"given":"Yongchao","family":"Han","sequence":"first","affiliation":[{"name":"China Institute of Atomic Energy, Beijing 102413, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6614-9639","authenticated-orcid":false,"given":"Shoulong","family":"Xu","sequence":"additional","affiliation":[{"name":"School of Resource Environment and Safety Engineering, University of South China, Hengyang 421001, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yang","family":"Liu","sequence":"additional","affiliation":[{"name":"School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ling","family":"Xu","sequence":"additional","affiliation":[{"name":"China Institute of Atomic Energy, Beijing 102413, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dawei","family":"Gong","sequence":"additional","affiliation":[{"name":"School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhiwei","family":"Qin","sequence":"additional","affiliation":[{"name":"School of Resource Environment and Safety Engineering, University of South China, Hengyang 421001, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hanfeng","family":"Dong","sequence":"additional","affiliation":[{"name":"School of Resource Environment and Safety Engineering, University of South China, Hengyang 421001, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Huaiqing","family":"Yang","sequence":"additional","affiliation":[{"name":"School of Resource Environment and Safety Engineering, University of South China, Hengyang 421001, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2022,3,16]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.nima.2012.12.043","article-title":"Active Pixel as Dosimetric Device for Interventional Radiology","volume":"720","author":"Servoli","year":"2013","journal-title":"Nucl. Inst. Methods Phys. Res. A"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1109\/TIM.2015.2476279","article-title":"Experimental Characterization of a Wireless Personal Sensor Node for the Dosimetry during Interventional Radiology Procedures","volume":"65","author":"Magalotti","year":"2016","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"2002","DOI":"10.1109\/TIM.2016.2534661","article-title":"Experimental Characterization of a Personal Wireless Sensor Network for the Medical X-ray Dosimetry","volume":"65","author":"Magalotti","year":"2016","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_4","unstructured":"Fu, M. (2012). Study on Key Parameters of CMOS MAPS for Charged Particle Detection. [Ph.D. Thesis, Dalian University of Technology]."},{"key":"ref_5","first-page":"387","article-title":"Can Smartphones Measure Radiation Exposures?","volume":"58","author":"Pang","year":"2015","journal-title":"Pac. Hist. Rev."},{"key":"ref_6","first-page":"651","article-title":"A vailability Evaluation and Improvement Plan of Image Sensor in Accident of Nuclear Power Plant","volume":"36","author":"Xu","year":"2016","journal-title":"Nucl. Electron. Detect. Technol."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Hirvonen, L.M., and Suhling, K. (2016). Photon Counting Imaging with an Electron-bombarded Pixel Image Sensor. Sensors, 16.","DOI":"10.3390\/s16050617"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Xu, S., Zou, S., Han, Y., and Qu, Y. (2018). Study on the Availability of 4t-aps as a Video Monitor and Radiation Detector in Nuclear Accidents. Sustainability, 10.","DOI":"10.3390\/su10072172"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1016\/j.nima.2016.04.072","article-title":"Particle detection and classification using commercial off the shelf CMOS image sensors","volume":"827","author":"Lipovetzky","year":"2016","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"P\u00e9rez, M., Haro, M.S., Sidelnik, I., Tozzi, L., Brito, D.R., Mora, C., Blostein, J.J., Berisso, M.G., and Lipovetzky, J. (2015, January 30\u201331). Commercial CMOS Pixel Array for Beta and Gamma Radiation Particle Counting. Proceedings of the Argentine School of Micro-Nanoelectronics, Villa Maria, Argentina.","DOI":"10.1109\/EAMTA.2015.7237371"},{"key":"ref_11","first-page":"175","article-title":"Nuclear Radiation Detection Based on Un-covered CMOS Camera under Static Scene","volume":"51","author":"Wei","year":"2017","journal-title":"At. Energy Sci. Technol."},{"key":"ref_12","first-page":"1278","article-title":"Direct Application of CMOS in Radiation Distribution and Exposure Rate Detection","volume":"10","author":"Wang","year":"2013","journal-title":"Nucl. Electron. Detect. Technol."},{"key":"ref_13","first-page":"60401","article-title":"Obtaining Low Energy \u03b3 Dose with CMOS Sensors","volume":"25","author":"Wang","year":"2014","journal-title":"Nucl. Sci. Tech."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"4383","DOI":"10.1088\/0031-9155\/60\/11\/4383","article-title":"Photon Small-field Measurements with a CMOS Active Pixel Sensor","volume":"60","author":"Spang","year":"2015","journal-title":"Phys. Med. Biol."},{"key":"ref_15","first-page":"77108","article-title":"Characterization of Total Ionizing Dose Damage in COTS Pinned Photodiode CMOS Image Sensors","volume":"6","author":"Wang","year":"2016","journal-title":"AIP Adv."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"34913","DOI":"10.1364\/OE.437580","article-title":"Low dose rate \u03b3-ray detection using a MAPS camera under a neutron radiation environment","volume":"29","author":"Xu","year":"2021","journal-title":"Opt. Express"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/6\/2279\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T22:37:11Z","timestamp":1760135831000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/6\/2279"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,16]]},"references-count":16,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2022,3]]}},"alternative-id":["s22062279"],"URL":"https:\/\/doi.org\/10.3390\/s22062279","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2022,3,16]]}}}