{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,30]],"date-time":"2025-12-30T08:57:46Z","timestamp":1767085066023,"version":"build-2065373602"},"reference-count":60,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2022,3,25]],"date-time":"2022-03-25T00:00:00Z","timestamp":1648166400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"POR Lazio FSE 2014\/2020","award":["CUP code n. F87C21000190009, Project ID 23562"],"award-info":[{"award-number":["CUP code n. F87C21000190009, Project ID 23562"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Heart rate (HR) and respiratory rate (fR) can be estimated by processing videos framing the upper body and face regions without any physical contact with the subject. This paper proposed a technique for continuously monitoring HR and fR via a multi-ROI approach based on the spectral analysis of RGB video frames recorded with a mobile device (i.e., a smartphone\u2019s camera). The respiratory signal was estimated by the motion of the chest, whereas the cardiac signal was retrieved from the pulsatile activity at the level of right and left cheeks and forehead. Videos were recorded from 18 healthy volunteers in four sessions with different user-camera distances (i.e., 0.5 m and 1.0 m) and illumination conditions (i.e., natural and artificial light). For HR estimation, three approaches were investigated based on single or multi-ROI approaches. A commercially available multiparametric device was used to record reference respiratory signals and electrocardiogram (ECG). The results demonstrated that the multi-ROI approach outperforms the single-ROI approach providing temporal trends of both the vital parameters comparable to those provided by the reference, with a mean absolute error (MAE) consistently below 1 breaths\u00b7min\u22121 for fR in all the scenarios, and a MAE between 0.7 bpm and 6 bpm for HR estimation, whose values increase at higher distances.<\/jats:p>","DOI":"10.3390\/s22072539","type":"journal-article","created":{"date-parts":[[2022,3,27]],"date-time":"2022-03-27T21:31:25Z","timestamp":1648416685000},"page":"2539","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":19,"title":["Multi-ROI Spectral Approach for the Continuous Remote Cardio-Respiratory Monitoring from Mobile Device Built-In Cameras"],"prefix":"10.3390","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6454-3491","authenticated-orcid":false,"given":"Nunzia","family":"Molinaro","sequence":"first","affiliation":[{"name":"Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering, Universit\u00e0 Campus Bio-Medico di Roma, 00128 Rome, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9696-1265","authenticated-orcid":false,"given":"Emiliano","family":"Schena","sequence":"additional","affiliation":[{"name":"Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering, Universit\u00e0 Campus Bio-Medico di Roma, 00128 Rome, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5863-8336","authenticated-orcid":false,"given":"Sergio","family":"Silvestri","sequence":"additional","affiliation":[{"name":"Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering, Universit\u00e0 Campus Bio-Medico di Roma, 00128 Rome, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3090-5623","authenticated-orcid":false,"given":"Carlo","family":"Massaroni","sequence":"additional","affiliation":[{"name":"Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering, Universit\u00e0 Campus Bio-Medico di Roma, 00128 Rome, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2022,3,25]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1016\/j.irbm.2020.04.001","article-title":"A Review of Methods for Non-Invasive Heart Rate Measurement on Wrist","volume":"42","author":"Gehin","year":"2021","journal-title":"IRBM"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.compbiomed.2014.08.014","article-title":"Heart Monitoring Systems\u2014A Review","volume":"54","author":"Jain","year":"2014","journal-title":"Comput. Biol. Med."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Nicol\u00f2, A., Massaroni, C., Schena, E., and Sacchetti, M. (2020). The Importance of Respiratory Rate Monitoring: From Healthcare to Sport and Exercise. Sensors, 20.","DOI":"10.3390\/s20216396"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"801709","DOI":"10.3389\/fphys.2022.801709","article-title":"Contactless Vital Signs Monitoring from Videos Recorded with Digital Cameras: An Overview","volume":"13","author":"Molinaro","year":"2022","journal-title":"Front. Physiol."},{"key":"ref_5","first-page":"12","article-title":"Doppler Radar Architectures and Signal Processing for Heart Rate Extraction","volume":"15","author":"Lubecke","year":"2009","journal-title":"Mikrotalasna Rev."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1418","DOI":"10.1109\/TBME.2007.891930","article-title":"Contact-free measurement of cardiac pulse based on the analysis of thermal imagery","volume":"54","author":"Garbey","year":"2004","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1016\/j.bspc.2017.07.004","article-title":"Heart Rate Estimation Using Facial Video: A Review","volume":"38","author":"Hassan","year":"2017","journal-title":"Biomed. Signal Process. Control"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1016\/S1566-0702(01)00267-3","article-title":"Modulatory Effects of Respiration","volume":"90","author":"Bernardi","year":"2001","journal-title":"Auton. Neurosci. Basic Clin."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Han, B., Ivanov, K., Yan, Y., and Wang, L. (2015, January 14\u201316). Exploration of the Optimal Skin-Camera Distance for Facial Photoplethysmographic Imaging Measurement Using Cameras of Different Types. Proceedings of the 5th EAI International Conference on Wireless Mobile Communication and Healthcare, London, UK.","DOI":"10.4108\/eai.14-10-2015.2261689"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Tayibnapis, I.R., Yang, Y.M., and Lim, K.M. (2018). Blood Volume Pulse Extraction for Non-Contact Heart Rate Measurement by Digital Camera Using Singular Value Decomposition and Burg Algorithm. Energies, 11.","DOI":"10.3390\/en11051076"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"5388","DOI":"10.1007\/s10489-020-02167-4","article-title":"Heart Rate Estimation Based on Face Video under Unstable Illumination","volume":"51","author":"Yin","year":"2021","journal-title":"Appl. Intell."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Yang, Z., Wang, H., and Lu, F. (2021). Assessment of Deep Learning-Based Heart Rate Estimation Using Remote Photoplethysmography under Different Illuminations. arXiv.","DOI":"10.1109\/THMS.2022.3207755"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"103535","DOI":"10.1016\/j.compbiomed.2019.103535","article-title":"New Insights on Super-High Resolution for Video-Based Heart Rate Estimation with a Semi-Blind Source Separation Method","volume":"116","author":"Song","year":"2020","journal-title":"Comput. Biol. Med."},{"key":"ref_14","unstructured":"Kwon, S., Kim, H., and Park, K.S. (September, January 28). Validation of Heart Rate Extraction Using Video Imaging on a Built-in Camera System of a Smartphone. Proceedings of the 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, San Diego, CA, USA."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Datcu, D., Cidota, M., Lukosch, S., and Rothkrantz, L. (2013, January 28\u201329). Noncontact Automatic Heart Rate Analysis in Visible Spectrum by Specific Face Regions. Proceedings of the 14th International Conference on Computer Systems and Technologies, Ruse, Bulgaria.","DOI":"10.1145\/2516775.2516805"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Lin, Y.-C., and Lin, Y.-H. (2017, January 11\u201315). A Study of Color Illumination Effect on the SNR of RPPG Signals. Proceedings of the 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Jeju Island, Korea.","DOI":"10.1109\/EMBC.2017.8037807"},{"key":"ref_17","unstructured":"Kwon, S., Kim, J., Lee, D., and Park, K. (2015, January 25\u201329). ROI Analysis for Remote Photoplethysmography on Facial Video. Proceedings of the 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Milano, Italy."},{"key":"ref_18","first-page":"1275","article-title":"Contactless Heart Rate Estimation from Face Videos","volume":"23","author":"Lamba","year":"2020","journal-title":"J. Stat. Manag. Syst."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1109\/JBHI.2020.2998399","article-title":"Non-Contact HR Monitoring via Smartphone and Webcam during Different Respiratory Maneuvers and Body Movements","volume":"25","author":"Shoushan","year":"2021","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2106","DOI":"10.3758\/s13428-019-01256-8","article-title":"An Open-Source Remote Heart Rate Imaging Method with Practical Apparatus and Algorithms","volume":"51","author":"Naber","year":"2019","journal-title":"Behav. Res. Methods"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"15776","DOI":"10.1109\/ACCESS.2017.2735419","article-title":"Monitoring of Cardiorespiratory Signal: Principles of Remote Measurements and Review of Methods","volume":"5","author":"Gibson","year":"2017","journal-title":"IEEE Access"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Balakrishnan, G., Durand, F., and Guttag, J. (2013, January 23\u201328). Detecting Pulse from Head Motions in Video. Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition, Portland, OR, USA.","DOI":"10.1109\/CVPR.2013.440"},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Park, K.S., and Yoon, H. (2018). Ballistocardiography. Seamless Healthcare Monitoring, Springer.","DOI":"10.1007\/978-3-319-69362-0_5"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Massaroni, C., Schena, E., Silvestri, S., Taffoni, F., and Merone, M. (2018, January 11\u201313). Measurement System Based on RBG Camera Signal for Contactless Breathing Pattern and Respiratory Rate Monitoring. Proceedings of the 2018 IEEE International Symposium on Medical Measurements and Applications (MeMeA), Rome, Italy.","DOI":"10.1109\/MeMeA.2018.8438692"},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Massaroni, C., Lo Presti, D., Formica, D., Silvestri, S., and Schena, E. (2019). Non-Contact Monitoring of Breathing Pattern and Respiratory Rate via Rgb Signal Measurement. Sensors, 19.","DOI":"10.3390\/s19122758"},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Chatterjee, A., Prathosh, A.P., and Praveena, P. (2016, January 16\u201320). Real-Time Respiration Rate Measurement from Thoracoabdominal Movement with a Consumer Grade Camera. Proceedings of the 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Orlando, FL, USA.","DOI":"10.1109\/EMBC.2016.7591289"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"2760","DOI":"10.1109\/TBME.2014.2327024","article-title":"Noncontact Monitoring Breathing Pattern, Exhalation Flow Rate and Pulse Transit Time","volume":"61","author":"Shao","year":"2014","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"4838","DOI":"10.1364\/BOE.8.004838","article-title":"Novel Health Monitoring Method Using an RGB Camera","volume":"8","author":"Hassan","year":"2017","journal-title":"Biomed. Opt. Express"},{"key":"ref_29","unstructured":"Chari, P., Kabra, K., Karinca, D., Lahiri, S., Srivastava, D., Kulkarni, K., Chen, T., Cannesson, M., Jalilian, L., and Kadambi, A. (2020). Diverse R-PPG: Camera-based heart rate estimation for diverse subject skin-tones and scenes. arXiv."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"R1","DOI":"10.1088\/0967-3334\/28\/3\/R01","article-title":"Photoplethysmography and Its Application in Clinical Physiological Measurement","volume":"28","author":"Allen","year":"2007","journal-title":"Physiol. Meas."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"300","DOI":"10.3389\/fpubh.2017.00300","article-title":"The PhysioCam: A Novel Non-Contact Sensor to Measure Heart Rate Variability in Clinical and Field Applications","volume":"5","author":"Davila","year":"2017","journal-title":"Front. Public Health"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"10762","DOI":"10.1364\/OE.18.010762","article-title":"Non-Contact, Automated Cardiac Pulse Measurements Using Video Imaging and Blind Source Separation","volume":"18","author":"Poh","year":"2010","journal-title":"Opt. Express"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1166\/jmihi.2012.1064","article-title":"Measuring Pulse Rate with a Webcam","volume":"2","author":"Lewandowska","year":"2012","journal-title":"J. Med. Imaging Health Inform."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"1479","DOI":"10.1109\/TBME.2016.2609282","article-title":"Algorithmic Principles of Remote PPG","volume":"64","author":"Wang","year":"2017","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"2878","DOI":"10.1109\/TBME.2013.2266196","article-title":"Robust Pulse Rate from Chrominance-Based RPPG","volume":"60","author":"Jeanne","year":"2013","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Schrumpf, F., Frenzel, P., Aust, C., Osterhoff, G., and Fuchs, M. (2021). Assessment of Non-Invasive Blood Pressure Prediction from PPG and RPPG Signals Using Deep Learning. Sensors, 21.","DOI":"10.3390\/s21186022"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"115001","DOI":"10.1088\/1361-6579\/ab525c","article-title":"Cardio-Respiratory Signal Extraction from Video Camera Data for Continuous Non-Contact Vital Sign Monitoring Using Deep Learning","volume":"40","author":"Chaichulee","year":"2019","journal-title":"Physiol. Meas."},{"key":"ref_38","unstructured":"Viola, P., and Jones, M. (2001, January 8\u201314). Rapid Object Detection Using a Boosted Cascade of Simple Features. Proceedings of the 2001 IEEE Computer Society Conference on Computer Vision and Pattern Recognition, CVPR 2001, Kauai, HI, USA."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"4567213","DOI":"10.1155\/2018\/4567213","article-title":"Contactless Monitoring of Breathing Patterns and Respiratory Rate at the Pit of the Neck: A Single Camera Approach","volume":"2018","author":"Massaroni","year":"2018","journal-title":"J. Sens."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"382","DOI":"10.61872\/sdj-2018-05-405","article-title":"The Face\u2014A Vascular Perspective. A Literature Review","volume":"128","author":"Tamura","year":"2018","journal-title":"Swiss Dent. J."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1016\/0004-3702(81)90024-2","article-title":"Determining Optical Flow","volume":"17","author":"Horn","year":"1981","journal-title":"Artif. Intell."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"154924","DOI":"10.1109\/ACCESS.2020.3018616","article-title":"Camera-Based Method for Respiratory Rhythm Extraction from a Lateral Perspective","volume":"8","year":"2020","journal-title":"IEEE Access"},{"key":"ref_43","doi-asserted-by":"crossref","unstructured":"Romano, C., Schena, E., Silvestri, S., and Massaroni, C. (2021). Non-Contact Respiratory Monitoring Using an RGB Camera for Real-World Applications. Sensors, 21.","DOI":"10.3390\/s21155126"},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Ibrahim, N., Tomari, R., Nurshazwani Wan Zakaria, W., and Othman, N. (2017, January 7). Analysis of Non-Invasive Video Based Heart Rate Monitoring System Obtained from Various Distances and Different Facial Spot. Proceedings of the International PostGraduate Conference on Applied Science & Physics, Johor, Malaysia.","DOI":"10.1088\/1742-6596\/1049\/1\/012003"},{"key":"ref_45","doi-asserted-by":"crossref","unstructured":"Krolak, A. (2017, January 20\u201322). Influence of Skin Tone on Efficiency of Vision-Based Heart Rate Estimation. Proceedings of the Polish Conference on Biocybernetics and Biomedical Engineering, Krak\u00f3w, Poland.","DOI":"10.1007\/978-3-319-66905-2_4"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1109\/10.979357","article-title":"An Advanced Detrending Method with Application to HRV Analysis","volume":"49","author":"Tarvainen","year":"2002","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1109\/TBME.2010.2086456","article-title":"Advancements in Noncontact, Multiparameter Physiological Measurements Using a Webcam","volume":"58","author":"Poh","year":"2011","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"2948","DOI":"10.1109\/TBME.2014.2340991","article-title":"Remote Detection of Photoplethysmographic Systolic and Diastolic Peaks Using a Digital Camera","volume":"61","author":"McDuff","year":"2014","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_49","doi-asserted-by":"crossref","unstructured":"Tasli, H.E., Gudi, A., and Den Uyl, M. (2014, January 27\u201330). Remote PPG based vital sign measurement using adaptive facial regions. Proceedings of the 2014 IEEE International Conference on Image Processing (ICIP), Paris, France.","DOI":"10.1109\/ICIP.2014.7025282"},{"key":"ref_50","doi-asserted-by":"crossref","unstructured":"Lempe, G., Zaunseder, S., Wirthgen, T., Zipster, S., and Malberg, H. (2013). ROI Selection for Remote Photoplethysmography. Bildverarbeitung f\u00fcr die Medizin, Springer.","DOI":"10.1007\/978-3-642-36480-8_19"},{"key":"ref_51","doi-asserted-by":"crossref","unstructured":"Stricker, R., M\u00fcller, S., and Gross, H. (2014, January 25\u201329). Non-Contact Video-Based Pulse Rate Measurement on a Mobile Service Robot. Proceedings of the 23rd IEEE International Symposium on Robot and Human Interactive Communication, Edinburgh, UK.","DOI":"10.1109\/ROMAN.2014.6926392"},{"key":"ref_52","doi-asserted-by":"crossref","unstructured":"Li, X., Chen, J., Zhao, G., and Pietik\u00e4inen, M. (2014, January 24\u201327). Remote Heart Rate Measurement From Face Videos under Realistic Situations. Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition, Columbus, OH, USA.","DOI":"10.1109\/CVPR.2014.543"},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"21434","DOI":"10.1364\/OE.16.021434","article-title":"Remote Plethysmographic Imaging Using Ambient Light","volume":"16","author":"Verkruysse","year":"2008","journal-title":"Opt. Express"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"642986","DOI":"10.3389\/fphys.2021.642986","article-title":"Development of a Novel Web Camera-Based Contact-Free Major Depressive Disorder Screening System Using Autonomic Nervous Responses Induced by a Mental Task and Its Clinical Application","volume":"12","author":"Unursaikhan","year":"2021","journal-title":"Front. Physiol."},{"key":"ref_55","first-page":"63r81","article-title":"An Overview of Independent Component Analysis and Its Applications","volume":"35","author":"Naik","year":"2011","journal-title":"Informatica"},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"107549","DOI":"10.1016\/j.apacoust.2020.107549","article-title":"Active-Beacon-Based Driver Sound Separation System for Autonomous Vehicle Applications","volume":"171","author":"Choi","year":"2021","journal-title":"Appl. Acoust."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1162\/089976699300016863","article-title":"High-Order Contrasts for Independent Component Analysis","volume":"11","author":"Cardoso","year":"1999","journal-title":"Neural Comput."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1002\/wics.101","article-title":"Principal Component Analysis","volume":"2","author":"Abdi","year":"2010","journal-title":"Wiley Interdiscip. Rev. Comput. Stat."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"350","DOI":"10.1109\/TBME.2020.2993649","article-title":"Multispectral Video Fusion for Non-Contact Monitoring of Respiratory Rate and Apnea","volume":"68","author":"Scebba","year":"2020","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"1499","DOI":"10.1088\/0967-3334\/34\/11\/1499","article-title":"Signal Recovery in Imaging Photoplethysmography","volume":"34","author":"Holton","year":"2013","journal-title":"Physiol. Meas."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/7\/2539\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T22:43:28Z","timestamp":1760136208000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/7\/2539"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,25]]},"references-count":60,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2022,4]]}},"alternative-id":["s22072539"],"URL":"https:\/\/doi.org\/10.3390\/s22072539","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2022,3,25]]}}}