{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,18]],"date-time":"2025-11-18T01:17:33Z","timestamp":1763428653958,"version":"build-2065373602"},"reference-count":32,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2022,4,10]],"date-time":"2022-04-10T00:00:00Z","timestamp":1649548800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The acoustic signal in the operation of a power transformer contains a lot of transformer operation state information, which is of great significance to the detection of DC bias state. In this paper, three typical parameters used for DC bias state detection are selected by comparing the acoustic variation of a 500 kV Jingting transformer substation No. 2 transformer with that of the core model built in the laboratory; then, acoustic samples of the 162 EHV normal state transformers are collected, and the distribution regularity of three typical parameters in normal state is given. Finally, according to the distribution regularity, clear warning threshold of typical parameters are given, and the DC bias cases from the 500 kV Jingting transformer substation are used to verify the effectiveness of the threshold.<\/jats:p>","DOI":"10.3390\/s22082906","type":"journal-article","created":{"date-parts":[[2022,4,10]],"date-time":"2022-04-10T23:06:01Z","timestamp":1649631961000},"page":"2906","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Acoustic Multi-Parameter Early Warning Method for Transformer DC Bias State"],"prefix":"10.3390","volume":"22","author":[{"given":"Yuhao","family":"Zhou","sequence":"first","affiliation":[{"name":"International Education Institute, North China Electric Power University (Baoding), Baoding 071003, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bowen","family":"Wang","sequence":"additional","affiliation":[{"name":"Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power University (Baoding), Baoding 071003, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2022,4,10]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1173","DOI":"10.1109\/61.296304","article-title":"An experimental analysis of DC excitation of transformers by geomagnetically induced currents","volume":"9","author":"Takasu","year":"1994","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1386","DOI":"10.1109\/TDEI.2015.005525","article-title":"Investigation of vibration impacts on HVAC transformer from HVDC system under monopole operation","volume":"23","author":"Ding","year":"2016","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"He, Y.D., Zhou, Q., Lin, S., and Zhao, L.P. (2020). Validity Evaluation Method Based on Data Driving for On-Line Monitoring Data of Transformer under DC-Bias. Sensors, 20.","DOI":"10.3390\/s20154321"},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Rusakov, V., and Raikher, Y. (2018). Magnetorelaxometry in the Presence of a DC Bias Field of Ferromagnetic Nanoparticles Bearing a Viscoelastic Corona. Sensors, 18.","DOI":"10.3390\/s18051661"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Asif, M., Lee, H.Y., Park, K.H., and Lee, B.W. (2020). Accurate Evaluation of Steady-State Sheath Voltage and Current in HVDC Cable Using Electromagnetic Transient Simulation. Energies, 12.","DOI":"10.3390\/en12214161"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"72629","DOI":"10.1109\/ACCESS.2018.2874624","article-title":"Influence of High Voltage DC Transmission on Measuring Accuracy of Current Transformers","volume":"6","author":"Yang","year":"2018","journal-title":"IEEE Access"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"861","DOI":"10.1109\/TPWRD.2017.2715040","article-title":"I Enhanced Independent Pole Control of Hybrid MMC-HVdc System","volume":"32","author":"Xiang","year":"2018","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_8","first-page":"4806136","article-title":"Calculation and Analysis of DC Magnetic Bias Current of Urban Main Transformer under the Action of Stray Current","volume":"2021","author":"Wu","year":"2021","journal-title":"Mob. Inf. Syst."},{"key":"ref_9","first-page":"4806136","article-title":"Modeling and Advanced Control of Dual-Active-Bridge DC-DC Converters: A Review","volume":"2021","author":"Shao","year":"2021","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_10","first-page":"8202904","article-title":"Magnetically Controlled Saturable Reactor Core Vibration Under Practical Working Conditions","volume":"53","author":"Ben","year":"2017","journal-title":"IEEE Trans. Magn."},{"key":"ref_11","first-page":"115","article-title":"Fractional Order Simple Chaotic Oscillator with Saturable Reactors and Its Engineering Applications","volume":"48","author":"Rajagopal","year":"2019","journal-title":"Inf. Technol. Control"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1585","DOI":"10.1177\/1077546311422925","article-title":"Application of high-resolution spectral analysis for identifying faults in induction motors by means of sound","volume":"18","year":"2012","journal-title":"J. Vib. Control"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"2621","DOI":"10.1177\/1077546316689644","article-title":"A dual sensor signal fusion approach for detection of faults in rotating machines","volume":"24","author":"Saimurugan","year":"2018","journal-title":"J. Vib. Control"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Zou, L., Guo, Y.K., Liu, H., and Zhao, T. (2018). A Method of Abnormal States Detection Based on Adaptive Extraction of Transformer Vibro-Acoustic Signals. Energies, 10.","DOI":"10.3390\/en10122076"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"9426","DOI":"10.1016\/j.eswa.2015.07.079","article-title":"An expert system for acoustic diagnosis of power circuit breakers and on-load tap changers","volume":"42","author":"Hussain","year":"2015","journal-title":"Expert Syst. Appl."},{"key":"ref_16","first-page":"061019","article-title":"Acoustic Radiation of a Cylindrical Piezoelectric Power Transformer","volume":"80","author":"Zhang","year":"2013","journal-title":"J. Vib. Control"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"660","DOI":"10.1049\/iet-epa.2015.0034","article-title":"A Parameter identification and prediction of Jiles-Atherton model for DC-biased transformer using improved shuffled frog leaping algorithm and least square support vector machine","volume":"9","author":"Wang","year":"2015","journal-title":"IET Electr. Power Appl."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"S173","DOI":"10.3233\/JAE-2014","article-title":"Vibrations of Transformer Cores Operating with Submagnetizing of DC Flux","volume":"51","author":"Majer","year":"2016","journal-title":"Int. J. Appl. Electromagn. Mech."},{"key":"ref_19","first-page":"6101304","article-title":"Research on Dynamic Magnetic Flux Measurement Under DC-Biased Magnetization by the Type-c Transducer","volume":"51","author":"Wang","year":"2015","journal-title":"IEEE Trans. Magn."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"8400804","DOI":"10.1109\/TMAG.2018.2839722","article-title":"A Novel Approach to Investigate the Core Vibration in Power Transformers","volume":"54","author":"Zhang","year":"2018","journal-title":"IEEE Trans. Magn."},{"key":"ref_21","first-page":"6100204","article-title":"Magnetostriction of Silicon Steel Sheets Under Different Magnetization Conditions","volume":"52","author":"Zhang","year":"2016","journal-title":"IEEE Trans. Magn."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Kunicki, M., and Wotzka, D. (2019). A Classification Method for Select Defects in Power Transformers Based on the Acoustic Signals. Sensors, 19.","DOI":"10.3390\/s19235212"},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Huerta, R.J.R., Granados, L.D., Garcia, P.A., Camarena, M.D., Amezquita, S.J.P., and Valtierra, R.M. (2021). Short-Circuited Turn Fault Diagnosis in Transformers by Using Vibration Signals, Statistical Time Features, and Support Vector Machines on FPGA. Sensors, 21.","DOI":"10.3390\/s21113598"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"83915","DOI":"10.1109\/ACCESS.2019.2923809","article-title":"Vibro-acoustic methods in the condition assessment of power transformers: A survey","volume":"7","author":"Secic","year":"2019","journal-title":"IEEE Access"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/j.measurement.2016.07.002","article-title":"A vibration measurement system for health monitoring of power transformers","volume":"93","author":"Hong","year":"2016","journal-title":"Measurement"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1109\/TPWRD.2003.820177","article-title":"Vibro-acoustic techniques to diagnose power transformers","volume":"19","author":"Bartoletti","year":"2004","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1109\/TPWRD.2005.852280","article-title":"Transformer tank vibration modeling as a method of detecting winding deformations-part I: Theoretical foundatio","volume":"21","author":"Burgos","year":"2006","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1109\/TPWRD.2005.852275","article-title":"Transformer tank vibration modeling as a method of detecting winding deformations-part II: Experimental verification","volume":"21","author":"Burgos","year":"2006","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.apacoust.2019.03.011","article-title":"Investigation on vibration source and transmission characteristics in power transformers","volume":"151","author":"Zhang","year":"2019","journal-title":"Appl. Acoust."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1666","DOI":"10.1109\/TPWRD.2019.2918151","article-title":"Multi-Frequency Acoustic Signal Under Short-Circuit Transient and Its Application on the Condition Monitoring of Transformer Winding","volume":"34","author":"Wang","year":"2019","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_31","first-page":"323","article-title":"The magnetostriction of iron under tensile and compressive stress","volume":"1","author":"Michael","year":"1971","journal-title":"Intern. J. Magn."},{"key":"ref_32","first-page":"1536","article-title":"Analysis on vibration characteristics of power transformer under DC bias","volume":"38","author":"Gao","year":"2014","journal-title":"Power Syst. Technol."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/8\/2906\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T22:51:20Z","timestamp":1760136680000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/8\/2906"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4,10]]},"references-count":32,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2022,4]]}},"alternative-id":["s22082906"],"URL":"https:\/\/doi.org\/10.3390\/s22082906","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2022,4,10]]}}}