{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T17:21:21Z","timestamp":1777656081342,"version":"3.51.4"},"reference-count":76,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2022,4,12]],"date-time":"2022-04-12T00:00:00Z","timestamp":1649721600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Current literature lacks a comparative analysis of different motion capture systems for tracking upper limb (UL) movement as individuals perform standard tasks. To better understand the performance of various motion capture systems in quantifying UL movement in the prosthesis user population, this study compares joint angles derived from three systems that vary in cost and motion capture mechanisms: a marker-based system (Vicon), an inertial measurement unit system (Xsens), and a markerless system (Kinect). Ten healthy participants (5F\/5M; 29.6 \u00b1 7.1 years) were trained with a TouchBionic i-Limb Ultra myoelectric terminal device mounted on a bypass prosthetic device. Participants were simultaneously recorded with all systems as they performed standardized tasks. Root mean square error and bias values for degrees of freedom in the right elbow, shoulder, neck, and torso were calculated. The IMU system yielded more accurate kinematics for shoulder, neck, and torso angles while the markerless system performed better for the elbow angles. By evaluating the ability of each system to capture kinematic changes of simulated upper limb prosthesis users during a variety of standardized tasks, this study provides insight into the advantages and limitations of using different motion capture technologies for upper limb functional assessment.<\/jats:p>","DOI":"10.3390\/s22082953","type":"journal-article","created":{"date-parts":[[2022,4,12]],"date-time":"2022-04-12T22:48:45Z","timestamp":1649803725000},"page":"2953","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Comparison of Motion Analysis Systems in Tracking Upper Body Movement of Myoelectric Bypass Prosthesis Users"],"prefix":"10.3390","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1439-9203","authenticated-orcid":false,"given":"Sophie L.","family":"Wang","sequence":"first","affiliation":[{"name":"Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, MD 20993, USA"},{"name":"Department of Bioengineering, University of Maryland, College Park, MD 20742, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gene","family":"Civillico","sequence":"additional","affiliation":[{"name":"Institute for Chemical Imaging of Living Systems, Northeastern University, Boston, MA 02115, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wesley","family":"Niswander","sequence":"additional","affiliation":[{"name":"Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, MD 20993, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4978-6011","authenticated-orcid":false,"given":"Kimberly L.","family":"Kontson","sequence":"additional","affiliation":[{"name":"Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, MD 20993, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2022,4,12]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1016\/0966-6362(95)99067-U","article-title":"Comparison of the performance of 3D camera systems","volume":"3","author":"Ehara","year":"1995","journal-title":"Gait Posture"},{"key":"ref_2","first-page":"61","article-title":"Optical Motion Capture: Theory and Implementation","volume":"12","year":"1995","journal-title":"J. Theor. Appl. Inform."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/0268-0033(95)00046-1","article-title":"Position and orientation in space of bones during movement: Experimental artefacts","volume":"11","author":"Cappozzo","year":"1996","journal-title":"Clin. Biomech."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1016\/S0003-9993(97)90162-3","article-title":"Quantification of upper extremity function using kinematic analysis","volume":"78","author":"Ramos","year":"1997","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"977","DOI":"10.1016\/S0021-9290(98)00083-9","article-title":"Skin movement artefact assessment and compensation in the estimation of knee-joint kinematics","volume":"31","author":"Lucchetti","year":"1998","journal-title":"J. Biomech."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1006\/cviu.1998.0744","article-title":"Human Motion Analysis: A Review","volume":"73","author":"Aggarwal","year":"1999","journal-title":"Comput. Vis. Image Underst."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1016\/S0167-9457(99)00023-8","article-title":"The measurement of human motion: A comparison of commercially available systems","volume":"18","author":"Richards","year":"1999","journal-title":"Hum. Mov. Sci."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"682","DOI":"10.1016\/j.jbiomech.2006.01.017","article-title":"Accuracy of an optical active-marker system to track the relative motion of rigid bodies","volume":"40","author":"Maletsky","year":"2007","journal-title":"J Biomech."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/j.cviu.2006.08.002","article-title":"A survey of advances in vision-based human motion capture and analysis","volume":"104","author":"Moeslund","year":"2006","journal-title":"Comput. Vis. Image Underst."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1186\/1743-0003-3-6","article-title":"The evolution of methods for the capture of human movement leading to markerless motion capture for biomechanical applications","volume":"3","author":"Mundermann","year":"2006","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Chang, C.-Y., Lange, B., Zhang, M., Koenig, S., Requejo, P., Somboon, N., Sawchuk, A., and Rizzo, A. (2012, January 21\u201324). Towards Pervasive Physical Rehabilitation Using Microsoft Kinect. Proceedings of the 2012 6th International Conference on Pervasive Computing Technologies for Healthcare (PervasiveHealth) and Workshops, San Diego, CA, USA.","DOI":"10.4108\/icst.pervasivehealth.2012.248714"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.medengphy.2013.09.002","article-title":"A wearable inertial system to assess the cervical spine mobility: Comparison with an optoelectronic-based motion capture evaluation","volume":"36","author":"Duc","year":"2014","journal-title":"Med. Eng. Phys."},{"key":"ref_13","first-page":"846514","article-title":"A Review on Technical and Clinical Impact of Microsoft Kinect on Physical Therapy and Rehabilitation","volume":"2014","author":"Khademi","year":"2014","journal-title":"J. Med. Eng."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"18813","DOI":"10.3390\/s150818813","article-title":"Upper Limb Kinematics Using Inertial and Magnetic Sensors: Comparison of Sensor-to-Segment Calibrations","volume":"15","author":"Bouvier","year":"2015","journal-title":"Sensors"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1177\/0309364613506913","article-title":"The DEKA Arm: Its features, functionality, and evolution during the Veterans Affairs Study to optimize the DEKA Arm","volume":"38","author":"Resnik","year":"2014","journal-title":"Prosthet. Orthot. Int."},{"key":"ref_16","first-page":"100057","article-title":"Comparison of DEKA Arm and body-powered upper limb prosthesis joint kinematics","volume":"2","author":"Bloomer","year":"2020","journal-title":"Arch. Rehabil. Res. Clin. Transl."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"255","DOI":"10.3109\/17483107.2012.704654","article-title":"Kinematic comparison of the wrist movements that are possible with a biomechatronics wrist prosthesis and a body-powered prosthesis: A preliminary study","volume":"8","year":"2013","journal-title":"Disabil. Rehabil. Assist. Technol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"e1960","DOI":"10.1002\/rcs.1960","article-title":"Transradial prostheses: Trends in development of hardware and control systems","volume":"15","author":"Semasinghe","year":"2019","journal-title":"Int. J. Med. Robot."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"318","DOI":"10.3109\/17483107.2013.822024","article-title":"Controlling a multi-degree of freedom upper limb prosthesis using foot controls: User experience","volume":"9","author":"Resnik","year":"2014","journal-title":"Disabil. Rehabil. Assist. Technol."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Bloomer, C., Wang, S., and Kontson, K. (2020). Kinematic analysis of motor learning in upper limb body-powered bypass prosthesis training. PLoS ONE, 15.","DOI":"10.1371\/journal.pone.0226563"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"2029","DOI":"10.1016\/j.apmr.2012.03.011","article-title":"Characterization of compensatory trunk movements during prosthetic upper limb reaching tasks","volume":"93","author":"Metzger","year":"2012","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"2184","DOI":"10.1109\/TBME.2013.2250286","article-title":"Markerless motion capture and measurement of hand kinematics: Validation and application to home-based upper limb rehabilitation","volume":"60","author":"Metcalf","year":"2013","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1080\/00140139.2015.1057238","article-title":"Comparison between low-cost marker-less and high-end marker-based motion capture systems for the computer-aided assessment of working ergonomics","volume":"59","author":"Patrizi","year":"2016","journal-title":"Ergonomics"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1016\/j.jse.2015.07.011","article-title":"Measurement of active shoulder motion using the Kinect, a commercially available infrared position detection system","volume":"25","author":"Matsen","year":"2016","journal-title":"J. Shoulder. Elbow. Surg."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1016\/j.gaitpost.2012.03.033","article-title":"Validity of the Microsoft Kinect for assessment of postural control","volume":"36","author":"Clark","year":"2012","journal-title":"Gait Posture"},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Fern\u2019ndez-Baena, A., Susin, A., and Lligadas, X. (2012, January 19\u201321). Biomechanical Validation of Upper-Body and Lower-Body Joint Movements of Kinect Motion Capture Data for Rehabilitation Treatments. Proceedings of the 2012 Fourth International Conference on Intelligent Networking and Collaborative Systems, Bucharest, Romania.","DOI":"10.1109\/iNCoS.2012.66"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1062","DOI":"10.1016\/j.gaitpost.2014.01.008","article-title":"Accuracy of the Microsoft Kinect sensor for measuring movement in people with Parkinson\u2019s disease","volume":"39","author":"Galna","year":"2014","journal-title":"Gait Posture"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1080\/10255840802326736","article-title":"The static accuracy and calibration of inertial measurement units for 3D orientation","volume":"11","author":"Brodie","year":"2008","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/j.math.2009.05.009","article-title":"Feasibility of using inertial sensors to assess human movement","volume":"15","author":"Bryant","year":"2010","journal-title":"Man. Ther."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"N63","DOI":"10.1088\/0967-3334\/34\/8\/N63","article-title":"Concurrent validation of Xsens MVN measurement of lower limb joint angular kinematics","volume":"34","author":"Zhang","year":"2013","journal-title":"Physiol. Meas."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1111\/evj.12529","article-title":"Comparison of a standalone consumer grade smartphone with a specialist inertial measurement unit for quantification of movement symmetry in the trotting horse","volume":"49","author":"Pfau","year":"2017","journal-title":"Equine Vet. J."},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Poitras, I., Bielmann, M., Campeau-Lecours, A., Mercier, C., Bouyer, L.J., and Roy, J.S. (2019). Validity of Wearable Sensors at the Shoulder Joint: Combining Wireless Electromyography Sensors and Inertial Measurement Units to Perform Physical Workplace Assessments. Sensors, 19.","DOI":"10.3390\/s19081885"},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Cuesta-Vargas, A.I., and Roldan-Jimenez, C. (2016). Validity and reliability of arm abduction angle measured on smartphone: A cross-sectional study. BMC Musculoskelet. Disord., 17.","DOI":"10.1186\/s12891-016-0957-3"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"23168","DOI":"10.3390\/s150923168","article-title":"Performance Evaluation of Smartphone Inertial Sensors Measurement for Range of Motion","volume":"15","author":"Mourcou","year":"2015","journal-title":"Sensors"},{"key":"ref_35","first-page":"555558","article-title":"A Comparison of Dual-Kinect and Vicon Tracking of Human Motion for Use in Robotic Motion Programming","volume":"1","author":"Schlagenhauf","year":"2017","journal-title":"Robot. Autom. Eng. J."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"2776","DOI":"10.1016\/j.jbiomech.2008.06.024","article-title":"Systematic accuracy and precision analysis of video motion capturing systems\u2014Exemplified on the Vicon-460 system","volume":"41","author":"Windolf","year":"2008","journal-title":"J. Biomech."},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Mjosund, H.L., Boyle, E., Kjaer, P., Mieritz, R.M., Skallgard, T., and Kent, P. (2017). Clinically acceptable agreement between the ViMove wireless motion sensor system and the Vicon motion capture system when measuring lumbar region inclination motion in the sagittal and coronal planes. BMC Musculoskelet. Disord., 18.","DOI":"10.1186\/s12891-017-1489-1"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"532","DOI":"10.1016\/j.gaitpost.2014.06.012","article-title":"Evaluation of the Microsoft Kinect as a clinical assessment tool of body sway","volume":"40","author":"Yeung","year":"2014","journal-title":"Gait Posture"},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Richter, C., Daniels, K.A.J., King, E., and Franklyn-Miller, A. (2020). Agreement between An Inertia and Optical Based Motion Capture during the VU-Return-to-Play- Field-Test. Sensors, 20.","DOI":"10.3390\/s20030831"},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Van der Straaten, R., Bruijnes, A., Vanwanseele, B., Jonkers, I., De Baets, L., and Timmermans, A. (2019). Reliability and Agreement of 3D Trunk and Lower Extremity Movement Analysis by Means of Inertial Sensor Technology for Unipodal and Bipodal Tasks. Sensors, 19.","DOI":"10.3390\/s19010141"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.gaitpost.2019.02.024","article-title":"Functional range of motion in the upper extremity and trunk joints: Nine functional everyday tasks with inertial sensors","volume":"70","author":"Dogan","year":"2019","journal-title":"Gait Posture"},{"key":"ref_42","doi-asserted-by":"crossref","unstructured":"Moon, Y., McGinnis, R.S., Seagers, K., Motl, R.W., Sheth, N., Wright, J.A., Ghaffari, R., and Sosnoff, J.J. (2017). Monitoring gait in multiple sclerosis with novel wearable motion sensors. PLoS ONE, 12.","DOI":"10.1371\/journal.pone.0171346"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1186\/1743-0003-10-31","article-title":"Automatic identification of inertial sensor placement on human body segments during walking","volume":"10","author":"Weenk","year":"2013","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Muller, B., Ilg, W., Giese, M.A., and Ludolph, N. (2017). Validation of enhanced kinect sensor based motion capturing for gait assessment. PLoS ONE, 12.","DOI":"10.1101\/098863"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"274","DOI":"10.3109\/03091902.2014.909540","article-title":"Comparative abilities of Microsoft Kinect and Vicon 3D motion capture for gait analysis","volume":"38","author":"Pfister","year":"2014","journal-title":"J. Med. Eng. Technol."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"27569","DOI":"10.3390\/s151127569","article-title":"Calibration of Kinect for Xbox One and Comparison between the Two Generations of Microsoft Sensors","volume":"15","author":"Pagliari","year":"2015","journal-title":"Sensors"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1016\/j.jbiomech.2013.11.031","article-title":"Accuracy and repeatability of joint angles measured using a single camera markerless motion capture system","volume":"47","author":"Schmitz","year":"2014","journal-title":"J. Biomech."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"2679","DOI":"10.1016\/j.jbiomech.2006.12.012","article-title":"System and modelling errors in motion analysis: Implications for the measurement of the elbow angle in cricket bowling","volume":"40","author":"Elliott","year":"2007","journal-title":"J. Biomech."},{"key":"ref_49","first-page":"951","article-title":"Evaluation of Performance-Based Outcome Measures for the Upper Limb: A Comprehensive Narrative Review","volume":"10","author":"Wang","year":"2018","journal-title":"PM R J. Inj. Funct. Rehabil."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1016\/0028-3932(71)90067-4","article-title":"The assessment and analysis of handedness: The Edinburgh inventory","volume":"9","author":"Oldfield","year":"1971","journal-title":"Neuropsychologia"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1053\/apmr.2003.50014","article-title":"Training with an upper-limb prosthetic simulator to enhance transfer of skill across limbs","volume":"84","author":"Weeks","year":"2003","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1682\/JRRD.2013.05.0123","article-title":"Comparison of body-powered voluntary opening and voluntary closing prehensor for activities of daily life","volume":"51","author":"Berning","year":"2014","journal-title":"J. Rehabil. Res. Dev."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1186\/1743-0003-11-16","article-title":"Changes in performance over time while learning to use a myoelectric prosthesis","volume":"11","author":"Bouwsema","year":"2014","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1177\/0309364614554030","article-title":"Assessment of body-powered upper limb prostheses by able-bodied subjects, using the Box and Blocks Test and the Nine-Hole Peg Test","volume":"40","author":"Haverkate","year":"2016","journal-title":"Prosthet. Orthot. Int."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1186\/s12984-016-0197-7","article-title":"Learning to use a body-powered prosthesis: Changes in functionality and kinematics","volume":"13","author":"Huinink","year":"2016","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"1","DOI":"10.15761\/PMRR.1000191","article-title":"Creating a standardized, quantitative training protocol for upper limb bypass prostheses","volume":"3","author":"Bloomer","year":"2018","journal-title":"Phys. Med. Rehabil. Res."},{"key":"ref_57","doi-asserted-by":"crossref","unstructured":"Kontson, K., Marcus, I., Myklebust, B., and Civillico, E. (2017). Targeted box and blocks test: Normative data and comparison to standard tests. PLoS ONE, 12.","DOI":"10.1371\/journal.pone.0177965"},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/j.jht.2018.10.002","article-title":"Assessing kinematic variability during performance of Jebsen-Taylor Hand Function Test","volume":"33","author":"Kontson","year":"2019","journal-title":"J. Hand. Ther."},{"key":"ref_59","first-page":"311","article-title":"An objective and standardized test of hand function","volume":"50","author":"Jebsen","year":"1969","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1682\/JRRD.2013.08.0180","article-title":"Self-reported and performance-based outcomes using DEKA Arm","volume":"51","author":"Resnik","year":"2014","journal-title":"J. Rehabil. Res. Dev."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1682\/JRRD.2013.09.0197","article-title":"Test-retest reliability and rater agreements of assessment of capacity for myoelectric control version 2.0","volume":"51","author":"Lindner","year":"2014","journal-title":"J. Rehabil. Res. Dev."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"1789","DOI":"10.1016\/j.apmr.2018.04.021","article-title":"Development and Psychometric Validation of Capacity Assessment of Prosthetic Performance for the Upper Limb (CAPPFUL)","volume":"99","author":"Kearns","year":"2018","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"870","DOI":"10.1002\/pmrj.12298","article-title":"Capacity Assessment of Prosthetic Performance for the Upper Limb (CAPPFUL): Characterization of Normative Kinematics and Performance","volume":"12","author":"Boyle","year":"2019","journal-title":"PMR"},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1016\/j.apmr.2012.10.004","article-title":"Development and evaluation of the activities measure for upper limb amputees","volume":"94","author":"Resnik","year":"2013","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_65","first-page":"32","article-title":"Evaluation of functional methods for human movement modelling","volume":"17","author":"Gastaldi","year":"2015","journal-title":"Acta. Bioeng. Biomech."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1016\/j.otsr.2009.04.012","article-title":"Upper extremity kinematics analysis in obstetrical brachial plexus palsy","volume":"95","author":"Fitoussi","year":"2009","journal-title":"Orthop. Traumatol. Surg. Res."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1186\/1475-925X-13-49","article-title":"Development and performance of a new prosthesis system using ultrasonic sensor for wrist movements: A preliminary study","volume":"13","author":"Gholizadeh","year":"2014","journal-title":"Biomed. Eng. Online"},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1016\/j.jbiomech.2005.01.008","article-title":"An upper extremity kinematic model for evaluation of hemiparetic stroke","volume":"39","author":"Hingtgen","year":"2006","journal-title":"J. Biomech."},{"key":"ref_69","doi-asserted-by":"crossref","unstructured":"Wouda, F.J., Giuberti, M., Bellusci, G., and Veltink, P.H. (2016). Estimation of Full-Body Poses Using Only Five Inertial Sensors: An Eager or Lazy Learning Approach?. Sensors, 16.","DOI":"10.3390\/s16122138"},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1016\/j.jbiomech.2005.11.011","article-title":"Ambulatory measurement of arm orientation","volume":"40","author":"Luinge","year":"2007","journal-title":"J. Biomech."},{"key":"ref_71","doi-asserted-by":"crossref","unstructured":"Al-Amri, M., Nicholas, K., Button, K., Sparkes, V., Sheeran, L., and Davies, J.L. (2018). Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity. Sensors, 18.","DOI":"10.3390\/s18030719"},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"24297","DOI":"10.3390\/s150924297","article-title":"Leveraging Two Kinect Sensors for Accurate Full-Body Motion Capture","volume":"15","author":"Gao","year":"2015","journal-title":"Sensors"},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1007\/s40846-016-0184-2","article-title":"Evaluation of Kinect 3D Sensor for Healthcare Imaging","volume":"36","author":"Pohlmann","year":"2016","journal-title":"J. Med. Biol. Eng."},{"key":"ref_74","unstructured":"iPiSoft (2019, February 01). User Guide for Multiple Depth Sensors Configuration. Available online: http:\/\/docs.ipisoft.com\/index.php?title=User_Guide_for_Multiple_Depth_Sensors_Configuration&oldid=2024."},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1037\/0033-2909.86.2.420","article-title":"Intraclass correlations: Uses in assessing rater reliability","volume":"86","author":"Shrout","year":"1979","journal-title":"Psychol. Bull."},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1007\/s11517-016-1537-2","article-title":"Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis","volume":"55","author":"Mecheri","year":"2017","journal-title":"Med. Biol. Eng. Comput."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/8\/2953\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T22:52:39Z","timestamp":1760136759000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/8\/2953"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4,12]]},"references-count":76,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2022,4]]}},"alternative-id":["s22082953"],"URL":"https:\/\/doi.org\/10.3390\/s22082953","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,4,12]]}}}