{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T22:08:58Z","timestamp":1783116538015,"version":"3.54.6"},"reference-count":162,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2022,6,1]],"date-time":"2022-06-01T00:00:00Z","timestamp":1654041600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Several illnesses that are chronic and acute are becoming more relevant as the world\u2019s aging population expands, and the medical sector is transforming rapidly, as a consequence of which the need for \u201cpoint-of-care\u201d (POC), identification\/detection, and real time management of health issues that have been required for a long time are increasing. Biomarkers are biological markers that help to detect status of health or disease. Biosensors\u2019 applications are for screening for early detection, chronic disease treatment, health management, and well-being surveillance. Smart devices that allow continual monitoring of vital biomarkers for physiological health monitoring, medical diagnosis, and assessment are becoming increasingly widespread in a variety of applications, ranging from biomedical to healthcare systems of surveillance and monitoring. The term \u201csmart\u201d is used due to the ability of these devices to extract data with intelligence and in real time. Wearable, implantable, ingestible, and portable devices can all be considered smart devices; this is due to their ability of smart interpretation of data, through their smart sensors or biosensors and indicators. Wearable and portable devices have progressed more and more in the shape of various accessories, integrated clothes, and body attachments and inserts. Moreover, implantable and ingestible devices allow for the medical diagnosis and treatment of patients using tiny sensors and biomedical gadgets or devices have become available, thus increasing the quality and efficacy of medical treatments by a significant margin. This article summarizes the state of the art in portable, wearable, ingestible, and implantable devices for health status monitoring and disease management and their possible applications. It also identifies some new technologies that have the potential to contribute to the development of personalized care. Further, these devices are non-invasive in nature, providing information with accuracy and in given time, thus making these devices important for the future use of humanity.<\/jats:p>","DOI":"10.3390\/s22114228","type":"journal-article","created":{"date-parts":[[2022,6,1]],"date-time":"2022-06-01T21:43:42Z","timestamp":1654119822000},"page":"4228","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":72,"title":["State of the Art in Smart Portable, Wearable, Ingestible and Implantable Devices for Health Status Monitoring and Disease Management"],"prefix":"10.3390","volume":"22","author":[{"given":"Shouvik","family":"Mukherjee","sequence":"first","affiliation":[{"name":"Department of Biotechnology, School of Chemical and Life Sciences, Jamia Hamdard, Hamdard Nagar, New Delhi 110062, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shariq","family":"Suleman","sequence":"additional","affiliation":[{"name":"Department of Biotechnology, School of Chemical and Life Sciences, Jamia Hamdard, Hamdard Nagar, New Delhi 110062, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5329-110X","authenticated-orcid":false,"given":"Roberto","family":"Pilloton","sequence":"additional","affiliation":[{"name":"National Research Council (CNR), Department of Chemical Sciences and Materials Technology (DSCTM), Institute of Crystallography (IC), Via Salaria Km. 29.3, Monterotondo, 00185 Rome, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jagriti","family":"Narang","sequence":"additional","affiliation":[{"name":"Department of Biotechnology, School of Chemical and Life Sciences, Jamia Hamdard, Hamdard Nagar, New Delhi 110062, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2618-3883","authenticated-orcid":false,"given":"Kirti","family":"Rani","sequence":"additional","affiliation":[{"name":"Amity Institute of Biotechnology, Amity University Uttar Pradesh Noida (Uttar Pradesh), Gautam Buddha Nagar 201303, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,6,1]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Guk, K., Han, G., Lim, J., Jeong, K., Kang, T., Lim, E.-K., and Jung, J. (2019). Evolution of Wearable Devices with Real-Time Disease Monitoring for Personalized Healthcare. Nanomaterials, 9.","DOI":"10.3390\/nano9060813"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"17759","DOI":"10.1039\/C5RA15269K","article-title":"Biosensor-based detection of tuberculosis","volume":"6","author":"Srivastava","year":"2016","journal-title":"RSC Adv."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Kami\u0161ali\u0107, A., Fister, I., Turkanovi\u0107, M., and Karakati\u0109, S. (2018). Sensors and Functionalities of Non-Invasive Wrist-Wearable Devices: A Review. Sensors, 18.","DOI":"10.3390\/s18061714"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"5235","DOI":"10.1021\/acs.nanolett.6b02326","article-title":"Visible-Frequency Dielectric Metasurfaces for Multiwavelength Achromatic and Highly Dispersive Holograms","volume":"16","author":"Wang","year":"2016","journal-title":"Nano Lett."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"4373","DOI":"10.1002\/adma.201504366","article-title":"Monitoring of Vital Signs with Flexible and Wearable Medical Devices","volume":"28","author":"Khan","year":"2016","journal-title":"Adv. Mater."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1016\/j.tibtech.2014.04.005","article-title":"Non-invasive wearable electrochemical sensors: A review","volume":"32","author":"Bandodkar","year":"2014","journal-title":"Trends Biotechnol."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Free, C., Phillips, G., Galli, L., Watson, L., Felix, L., Edwards, P., Patel, V., and Haines, A. (2013). The Effectiveness of Mobile-Health Technology-Based Health Behaviour Change or Disease Management Interventions for Health Care Consumers: A Systematic Review. PLoS Med., 10.","DOI":"10.1371\/journal.pmed.1001362"},{"key":"ref_8","unstructured":"Narayan, R.J. (2016). Intelligent tattoos, patches, and other wearable biosensors. Medical Biosensors for Point of Care (POC) Applications, Woodhead Publishing."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1097\/00001573-200403000-00004","article-title":"Recent advances in pacemaker and implantable defibrillator therapy for young patients","volume":"19","author":"Walsh","year":"2004","journal-title":"Curr. Opin. Cardiol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"231","DOI":"10.4258\/hir.2012.18.3.231","article-title":"Book Review: mHealth: New Horizons for Health through Mobile Technologies: Based on the Findings of the Second Global Survey on eHealth (Global Observatory for eHealth Series, Volume 3)","volume":"18","author":"Ryu","year":"2012","journal-title":"Healthc. Informatics Res."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1007\/s10728-015-0309-8","article-title":"Implantable Smart Technologies (IST): Defining the \u2018Sting\u2019 in Data and Device","volume":"24","author":"Haddow","year":"2016","journal-title":"Healthc. Care Anal."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1016\/j.glohj.2019.07.001","article-title":"Smart healthcare: Making medical care more intelligent","volume":"3","author":"Tian","year":"2019","journal-title":"Glob. Heal. J."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"e18907","DOI":"10.2196\/18907","article-title":"Wearable Health Devices in Health Care: Narrative Systematic Review","volume":"8","author":"Lu","year":"2020","journal-title":"JMIR mHealth uHealth"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1021\/acssensors.7b00045","article-title":"Ingestible Sensors","volume":"2","author":"Ha","year":"2017","journal-title":"ACS Sens."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/j.addr.2020.05.004","article-title":"Orally ingestible medical devices for gut engineering","volume":"165\u2013166","author":"Mandsberg","year":"2020","journal-title":"Adv. Drug Deliv. Rev."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1016\/j.addr.2009.11.016","article-title":"Nano\/Microfluidics for diagnosis of infectious diseases in developing countries","volume":"62","author":"Lee","year":"2010","journal-title":"Adv. Drug Deliv. Rev."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Tyagi, H., Daulton, E., Bannaga, A.S., Arasaradnam, R.P., and Covington, J.A. (2021). Non-Invasive Detection and Staging of Colorectal Cancer Using a Portable Electronic Nose. Sensors, 21.","DOI":"10.3390\/s21165440"},{"key":"ref_18","unstructured":"Michael Okun, B.S., and Zeilman, P.R. (2014). A Practical Guide for Patients and Families, National Parkinson Foundation. [2nd ed.]. Available online: https:\/\/books.google.co.in\/books?id=ldqAoAEACAAJ."},{"key":"ref_19","first-page":"55","article-title":"Implantable Cardiac Pacemakers\u201450 Years from the First Implantation","volume":"79","year":"2010","journal-title":"Slov. Med. J."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Toledano, M., Toledano-Osorio, M., Carrasco-Carmona, \u00c1., Vallecillo, C., Toledano, R., Medina-Castillo, A.L., and Osorio, R. (2020). State of the art on biomaterials for soft tissue augmentation in the oral cavity. Part II: Synthetic polymers-based biomaterials. Polymers, 12.","DOI":"10.3390\/polym12081845"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"194","DOI":"10.21037\/atm.2017.03.90","article-title":"The history of time for capsule endoscopy","volume":"5","author":"Adler","year":"2017","journal-title":"Ann. Transl. Med."},{"key":"ref_22","first-page":"329","article-title":"Pill camera","volume":"5","author":"Dahad","year":"2016","journal-title":"Int. J. Adv. Res. Comput. Commun. Eng."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1007\/s00535-007-2153-6","article-title":"Capsule endoscopy: Past, present, and future","volume":"43","author":"Nakamura","year":"2008","journal-title":"J. Gastroenterol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1159\/000345346","article-title":"Review Article on Current Applications and Future Concepts of Capsule Endoscopy","volume":"87","author":"Neumann","year":"2013","journal-title":"Digestion"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"e91","DOI":"10.1002\/mp.12299","article-title":"Magnetically guided capsule endoscopy","volume":"44","author":"Shamsudhin","year":"2017","journal-title":"Med. Phys."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2012\/807165","article-title":"Ingestible Wireless Capsule Technology: A Review of Development and Future Indication","volume":"2012","author":"Basar","year":"2012","journal-title":"Int. J. Antennas Propag."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1109\/MPRV.2008.17","article-title":"Swallowable-Capsule Technology","volume":"7","author":"Chevalerias","year":"2008","journal-title":"IEEE Pervasive Comput."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1016\/j.snb.2015.04.063","article-title":"Development of a wireless swallowable capsule with potentiostatic electrochemical sensor for gastrointestinal track investigation","volume":"218","author":"Twomey","year":"2015","journal-title":"Sensors Actuators B Chem."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"eaaz0127","DOI":"10.1126\/sciadv.aaz0127","article-title":"Ingestible transiently anchoring electronics for microstimulation and conductive signaling","volume":"6","author":"Abramson","year":"2020","journal-title":"Sci. Adv."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Memon, F., Touma, G., Wang, J., Baltsavias, S., Moini, A., Chang, C., Rasmussen, M.F., Nikoozadeh, A., Choe, J.W., and Olcott, E. (2016, January 18\u201321). Capsule ultrasound device: Further developments. Proceedings of the 2016 IEEE International Ultrasonics Symposium (IUS), Tours, France.","DOI":"10.1109\/ULTSYM.2016.7728851"},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Memon, F., Touma, G., Wang, J., Baltsavias, S., Moini, A., Chang, C., Rasmussen, M.F., Nikoozadeh, A., Choe, J.W., and Arbabian, A. (2015, January 21\u201324). Capsule ultrasound device. Proceedings of the 2015 IEEE International Ultrasonics Symposium (IUS), Taipei, Taiwan.","DOI":"10.1109\/ULTSYM.2015.0168"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1109\/TBME.2014.2341272","article-title":"An Ingestible Sensor for Measuring Medication Adherence","volume":"62","author":"Hafezi","year":"2014","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"16043","DOI":"10.1038\/micronano.2016.43","article-title":"Emerging flexible and wearable physical sensing platforms for healthcare and biomedical applications","volume":"2","author":"Kenry","year":"2016","journal-title":"Microsyst. Nanoeng."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"9614","DOI":"10.1021\/acsnano.7b04898","article-title":"Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring","volume":"11","author":"Liu","year":"2017","journal-title":"ACS Nano"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1049\/el.2013.3715","article-title":"Ferroelectret film-based patch-type sensor for continuous blood pressure monitoring","volume":"50","author":"Noh","year":"2014","journal-title":"Electron. Lett."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"1178","DOI":"10.1002\/adfm.201504560","article-title":"Flexible Piezoresistive Sensor Patch Enabling Ultralow Power Cuffless Blood Pressure Measurement","volume":"26","author":"Luo","year":"2015","journal-title":"Adv. Funct. Mater."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"031301","DOI":"10.1063\/1.4921039","article-title":"The microfluidics of the eccrine sweat gland, including biomarker partitioning, transport, and biosensing implications","volume":"9","author":"Sonner","year":"2015","journal-title":"Biomicrofluidics"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"2632","DOI":"10.1039\/C8LC00510A","article-title":"A wearable patch for continuous monitoring of sweat electrolytes during exertion","volume":"18","author":"Alizadeh","year":"2018","journal-title":"Lab Chip"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1016\/S0924-4247(03)00049-9","article-title":"A PDMS dermal patch for non-intrusive transdermal glucose sensing","volume":"104","author":"Paranjape","year":"2003","journal-title":"Sens. Actuators A Phys."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1016\/j.amjsurg.2008.06.015","article-title":"Effectiveness of a noninvasive digital infrared thermal imaging system in the detection of breast cancer","volume":"196","author":"Arora","year":"2008","journal-title":"Am. J. Surg."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1177\/1534735408326171","article-title":"A Comparative Review of Thermography as a Breast Cancer Screening Technique","volume":"8","author":"Kennedy","year":"2009","journal-title":"Integr. Cancer Ther."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"23468","DOI":"10.1038\/srep23468","article-title":"A Flexible and Wearable Human Stress Monitoring Patch","volume":"6","author":"Yoon","year":"2016","journal-title":"Sci. Rep."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"502","DOI":"10.1002\/adma.201504441","article-title":"An All-Elastomeric Transparent and Stretchable Temperature Sensor for Body-Attachable Wearable Electronics","volume":"28","author":"Trung","year":"2016","journal-title":"Adv. Mater."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"2353","DOI":"10.1373\/clinchem.2004.039701","article-title":"Photonic Crystal Glucose-Sensing Material for Noninvasive Monitoring of Glucose in Tear Fluid","volume":"50","author":"Alexeev","year":"2004","journal-title":"Clin. Chem."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1089\/dia.2006.8.312","article-title":"Fluorescent Measurement in the Non-Invasive Contact Lens Glucose Sensor","volume":"8","author":"March","year":"2006","journal-title":"Diabetes Technol. Ther."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1016\/j.snb.2011.12.049","article-title":"A contact lens with an integrated lactate sensor","volume":"162","author":"Thomas","year":"2012","journal-title":"Sens. Actuators B Chem."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"1061","DOI":"10.1016\/j.bios.2015.07.039","article-title":"Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics","volume":"74","author":"Kim","year":"2015","journal-title":"Biosens. Bioelectron."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"1170","DOI":"10.1002\/elan.201600083","article-title":"Cavitas Sensors: Contact Lens Type Sensors & Mouthguard Sensors","volume":"28","author":"Mitsubayashi","year":"2016","journal-title":"Electroanalysis"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"1703257","DOI":"10.1002\/adma.201703257","article-title":"Functional, RF-Trilayer Sensors for Tooth-Mounted, Wireless Monitoring of the Oral Cavity and Food Consumption","volume":"30","author":"Tseng","year":"2018","journal-title":"Adv. Mater."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1038\/s41587-019-0045-y","article-title":"Wearable biosensors for healthcare monitoring","volume":"37","author":"Kim","year":"2019","journal-title":"Nat. Biotechnol."},{"key":"ref_51","unstructured":"Sazonov, E. (2020). From wearables to implantables\u2014Clinical drive and technical challenges. Wearable Sensors, Academic Press."},{"key":"ref_52","first-page":"42","article-title":"The epidemiology of pacemaker implantation in the United States","volume":"110","author":"Silverman","year":"1995","journal-title":"Public Health Rep."},{"key":"ref_53","doi-asserted-by":"crossref","unstructured":"Vega, K., Jiang, N., Liu, X., Kan, V., Barry, N., Maes, P., Yetisen, A., and Paradiso, J. (2017, January 11\u201315). The dermal abyss: Interfacing with the skin by tattooing biosensors. Proceedings of the ISWC \u201917: Proceedings of the 2017 ACM International Symposium on Wearable Computers, Maui, Hawaii.","DOI":"10.1145\/3123021.3123039"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"1704821","DOI":"10.1002\/adma.201704821","article-title":"3D Printing of Living Responsive Materials and Devices","volume":"30","author":"Liu","year":"2018","journal-title":"Adv. Mater."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1038\/s41582-020-00426-z","article-title":"Technology of deep brain stimulation: Current status and future directions","volume":"17","author":"Krauss","year":"2020","journal-title":"Nat. Rev. Neurol."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"6553","DOI":"10.1021\/ac401573r","article-title":"Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration","volume":"85","author":"Jia","year":"2013","journal-title":"Anal. Chem."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"7031","DOI":"10.1039\/c3an01672b","article-title":"A potentiometric tattoo sensor for monitoring ammonium in sweat","volume":"138","author":"Guinovart","year":"2013","journal-title":"Analyst"},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1021\/ac504300n","article-title":"Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study","volume":"87","author":"Bandodkar","year":"2015","journal-title":"Anal. Chem."},{"key":"ref_59","first-page":"79","article-title":"A human pilot trial of ingestible electronic capsules capable of sensing different gases in the gut","volume":"1","author":"Berean","year":"2017","journal-title":"Nat. Electron."},{"key":"ref_60","first-page":"1821","article-title":"In Vivo Wireless Sensors for Gut Microbiome Redox Monitoring","volume":"67","author":"Baltsavias","year":"2020","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_61","doi-asserted-by":"crossref","unstructured":"Belknap, R., Weis, S., Brookens, A., Au-Yeung, K.Y., Moon, G., Dicarlo, L., and Reves, R. (2013). Feasibility of an Ingestible Sensor-Based System for Monitoring Adherence to Tuberculosis Therapy. PLoS ONE, 8.","DOI":"10.1371\/journal.pone.0053373"},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"e7833","DOI":"10.2196\/jmir.7833","article-title":"Effectiveness of Digital Medicines to Improve Clinical Outcomes in Patients with Uncontrolled Hypertension and Type 2 Diabetes: Prospective, Open-Label, Cluster-Randomized Pilot Clinical Trial","volume":"19","author":"Frias","year":"2017","journal-title":"J. Med. Internet Res."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1017\/S0263574709990361","article-title":"Robotic magnetic steering and locomotion of capsule endoscope for diagnostic and surgical endoluminal procedures","volume":"28","author":"Ciuti","year":"2010","journal-title":"Robotica"},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"AB165","DOI":"10.1016\/j.gie.2007.03.264","article-title":"Validation of a New Pillcam\u2122 SB2 Video Capsule Versus the Standard Pillcam\u2122 SB for Detection of Small Bowel Disease","volume":"65","author":"Adler","year":"2007","journal-title":"Gastrointest. Endosc."},{"key":"ref_65","unstructured":"Rajbhandary, P., and Nallathambi, G. (2021). Validity and reliability of oral temperature compared to ingestible core temperature pill in free-living conditions. arXiv."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1016\/j.jtherbio.2004.08.020","article-title":"Validation of a new telemetric core temperature monitor","volume":"29","author":"McKenzie","year":"2004","journal-title":"J. Therm. Biol."},{"key":"ref_67","first-page":"16","article-title":"The Ingestible Thermal Monitoring System","volume":"9","author":"Cutchis","year":"1988","journal-title":"Johns Hopkins APL Tech. Dig."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.dld.2007.10.025","article-title":"The Bravo\u2122 pH capsule system","volume":"40","author":"Kwiatek","year":"2008","journal-title":"Dig. Liver Dis."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"2928","DOI":"10.1007\/s10620-011-1751-6","article-title":"Generalized Transit Delay on Wireless Motility Capsule Testing in Patients with Clinical Suspicion of Gastroparesis, Small Intestinal Dysmotility, or Slow Transit Constipation","volume":"56","author":"Kuo","year":"2011","journal-title":"Am. J. Dig. Dis. Sci."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1177\/1756283X12437874","article-title":"Evaluation of regional and whole gut motility using the wireless motility capsule: Relevance in clinical practice","volume":"5","author":"Tran","year":"2012","journal-title":"Ther. Adv. Gastroenterol."},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1109\/RBME.2011.2171182","article-title":"Capsule Endoscopy: From Current Achievements to Open Challenges","volume":"4","author":"Ciuti","year":"2011","journal-title":"IEEE Rev. Biomed. Eng."},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"352","DOI":"10.1109\/TBME.2014.2352493","article-title":"OdoCapsule: Next-Generation Wireless Capsule Endoscopy with Accurate Lesion Localization and Video Stabilization Capabilities","volume":"62","author":"Karargyris","year":"2014","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1016\/j.tibtech.2015.02.002","article-title":"Human intestinal gas measurement systems: In vitro fermentation and gas capsules","volume":"33","author":"Ou","year":"2015","journal-title":"Trends Biotechnol."},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1053\/j.gastro.2015.07.072","article-title":"Intestinal Gas Capsules: A Proof-of-Concept Demonstration","volume":"150","author":"Yao","year":"2016","journal-title":"Gastroenterology"},{"key":"ref_75","doi-asserted-by":"crossref","unstructured":"Lay, H.S., Qiu, Y., Al-Rawhani, M., Beeley, J., Poltarjonoks, R., Seetohul, V., Cumming, D., Cochran, S., Cummins, G., and Desmulliez, M.P.Y. (2016, January 18\u201321). Progress towards a multi-modal capsule endoscopy device featuring microultrasound imaging. Proceedings of the 2016 IEEE International Ultrasonics Symposium (IUS), Tours, France.","DOI":"10.1109\/ULTSYM.2016.7728692"},{"key":"ref_76","doi-asserted-by":"crossref","unstructured":"Wang, J., Memon, F., Touma, G., Baltsavias, S., Jang, J.H., Chang, C., Rasmussen, M.F., Olcott, E., Jeffrey, R.B., and Arbabian, A. (2017, January 6\u20139). Capsule ultrasound device: Characterization and testing results. Proceedings of the 2017 IEEE International Ultrasonics Symposium (IUS), Washington, DC, USA.","DOI":"10.1109\/ULTSYM.2017.8092071"},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1038\/nrd1417","article-title":"Microbubbles in medical imaging: Current applications and future directions","volume":"3","author":"Lindner","year":"2004","journal-title":"Nat. Rev. Drug Discov."},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"8378","DOI":"10.1039\/C5CP07538F","article-title":"Complex interfaces in \u201cphase-change\u201d contrast agents","volume":"18","author":"Capece","year":"2016","journal-title":"Phys. Chem. Chem. Phys."},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"128522","DOI":"10.1016\/j.colsurfa.2022.128522","article-title":"Improved hybrid-shelled perfluorocarbon microdroplets as ultrasound- and laser-activated phase-change platform","volume":"641","author":"Palmieri","year":"2022","journal-title":"Colloids Surf. A Physicochem. Eng. Asp."},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"2573","DOI":"10.1109\/COMST.2017.2731979","article-title":"A Survey of Wearable Devices and Challenges","volume":"19","author":"Seneviratne","year":"2017","journal-title":"IEEE Commun. Surv. Tutor."},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"349","DOI":"10.3938\/jkps.58.349","article-title":"Estimated Blood Pressure Algorithm for a Wrist-wearable Pulsimeter Using Hall Device","volume":"58","author":"Lee","year":"2011","journal-title":"J. Korean Phys. Soc."},{"key":"ref_82","doi-asserted-by":"crossref","unstructured":"Hsu, Y.-P., and Young, D.J. (2013, January 3\u20136). Skin-surface-coupled personal health monitoring system. Proceedings of the IEEE 2013 International Conference on Sensors, Baltimore, MD, USA.","DOI":"10.1109\/ICSENS.2013.6688176"},{"key":"ref_83","doi-asserted-by":"crossref","unstructured":"Ishikawa, T., Hyodo, Y., Miyashita, K., Yoshifuji, K., Komoriya, Y., and Imai, Y. (2017, January 21\u201323). Wearable motion tolerant PPG sensor for instant heart rate in daily activity. Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2017), Porto, Portugal.","DOI":"10.5220\/0006109901260133"},{"key":"ref_84","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1016\/j.aca.2012.03.043","article-title":"Non-invasive glucose monitoring technology in diabetes management: A review","volume":"750","author":"Vashist","year":"2012","journal-title":"Anal. Chim. Acta"},{"key":"ref_85","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.jns.2019.04.011","article-title":"Smartwatch for the analysis of rest tremor in patients with Parkinson\u2019s disease","volume":"401","author":"Velasco","year":"2019","journal-title":"J. Neurol. Sci."},{"key":"ref_86","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1001\/jamacardio.2018.0136","article-title":"Passive Detection of Atrial Fibrillation Using a Commercially Available Smartwatch","volume":"3","author":"Tison","year":"2018","journal-title":"JAMA Cardiol."},{"key":"ref_87","doi-asserted-by":"crossref","unstructured":"Constant, N., Douglas-Prawl, O., Johnson, S., and Mankodiya, K. (2015, January 9\u201312). Pulse-Glasses: An unobtrusive, wearable HR monitor with Internet-of-Things functionality. Proceedings of the 2015 IEEE 12th International Conference on Wearable and Implantable Body Sensor Networks (BSN), Cambridge, MA, USA.","DOI":"10.1109\/BSN.2015.7299350"},{"key":"ref_88","doi-asserted-by":"crossref","first-page":"1834","DOI":"10.1039\/C7LC00192D","article-title":"Eyeglasses based wireless electrolyte and metabolite sensor platform","volume":"17","author":"Sempionatto","year":"2017","journal-title":"Lab Chip"},{"key":"ref_89","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1016\/j.bios.2015.12.014","article-title":"Mouthguard biosensor with telemetry system for monitoring of saliva glucose: A novel cavitas sensor","volume":"84","author":"Arakawa","year":"2016","journal-title":"Biosens. Bioelectron."},{"key":"ref_90","doi-asserted-by":"crossref","first-page":"1632","DOI":"10.1039\/C3AN02359A","article-title":"Non-invasive mouthguard biosensor for continuous salivary monitoring of metabolites","volume":"139","author":"Kim","year":"2014","journal-title":"Analyst"},{"key":"ref_91","doi-asserted-by":"crossref","first-page":"e1706910","DOI":"10.1002\/adma.201706910","article-title":"Wearables in Medicine","volume":"30","author":"Yetisen","year":"2018","journal-title":"Adv. Mater."},{"key":"ref_92","doi-asserted-by":"crossref","first-page":"2093","DOI":"10.1039\/C6LC00307A","article-title":"Embroidered electrochemical sensors for biomolecular detection","volume":"16","author":"Liu","year":"2016","journal-title":"Lab Chip"},{"key":"ref_93","doi-asserted-by":"crossref","unstructured":"Pacelli, M., Loriga, G., Taccini, N., and Paradiso, R. (2006, January 4\u20136). Sensing fabrics for monitoring physiological and biomechanical variables: E-textile solutions. Proceedings of the 3rd IEEE-EMBS International Summer School and Symposium on Medical Devices and Biosensors, MIT, Boston, MA, USA.","DOI":"10.1109\/ISSMDBS.2006.360082"},{"key":"ref_94","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.1139\/apnm-2015-0140","article-title":"Validation of the Hexoskin wearable vest during lying, sitting, standing, and walking activities","volume":"40","author":"Villar","year":"2015","journal-title":"Appl. Physiol. Nutr. Metab."},{"key":"ref_95","doi-asserted-by":"crossref","unstructured":"Jung, P.-G., Lim, G., and Kong, K. (2013, January 6\u201310). A mobile motion capture system based on inertial sensors and smart shoes. Proceedings of the 2013 IEEE International Conference on Robotics and Automation, Karlsruhe, Germany.","DOI":"10.1109\/ICRA.2013.6630648"},{"key":"ref_96","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1016\/j.medengphy.2016.02.004","article-title":"Objectively quantifying walking ability in degenerative spinal disorder patients using sensor equipped smart shoes","volume":"38","author":"Lee","year":"2016","journal-title":"Med. Eng. Phys."},{"key":"ref_97","doi-asserted-by":"crossref","first-page":"553","DOI":"10.1021\/acssensors.7b00051","article-title":"Wearable Flexible and Stretchable Glove Biosensor for On-Site Detection of Organophosphorus Chemical Threats","volume":"2","author":"Mishra","year":"2017","journal-title":"ACS Sens."},{"key":"ref_98","doi-asserted-by":"crossref","first-page":"194","DOI":"10.2337\/ds18-0091","article-title":"A Clinical Overview of Insulin Pump Therapy for the Management of Diabetes: Past, Present, and Future of Intensive Therapy","volume":"32","author":"Berget","year":"2019","journal-title":"Diabetes Spectr."},{"key":"ref_99","doi-asserted-by":"crossref","first-page":"29","DOI":"10.2147\/MDER.S135882","article-title":"Digital stethoscope: Technology update","volume":"11","author":"Swarup","year":"2018","journal-title":"Med. Devices E\u00c9vid. Res."},{"key":"ref_100","first-page":"e5547","article-title":"Use of Handheld Video Otoscopy for the Diagnosis of Acute Otitis Media","volume":"11","author":"Soares","year":"2019","journal-title":"Cureus"},{"key":"ref_101","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1093\/ije\/dys135","article-title":"Convergence of non-communicable and infectious diseases in low- and middle-income countries","volume":"42","author":"Remais","year":"2013","journal-title":"Int. J. Epidemiol."},{"key":"ref_102","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/j.procbio.2020.04.006","article-title":"Systematic and validated techniques for the detection of ovarian cancer emphasizing the electro-analytical approach","volume":"94","author":"Anzar","year":"2020","journal-title":"Process Biochem."},{"key":"ref_103","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1016\/j.drudis.2010.08.006","article-title":"Cancer nanotechnology: Application of nanotechnology in cancer therapy","volume":"15","author":"Misra","year":"2010","journal-title":"Drug Discov. Today"},{"key":"ref_104","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1093\/jnci\/djy100","article-title":"Analgesic Use and Ovarian Cancer Risk: An Analysis in the Ovarian Cancer Cohort Consortium","volume":"111","author":"Trabert","year":"2019","journal-title":"JNCI J. Natl. Cancer Inst."},{"key":"ref_105","doi-asserted-by":"crossref","first-page":"1402","DOI":"10.1002\/elan.201501174","article-title":"Electrochemical Biosensors for Cancer Biomarkers Detection: Recent Advances and Challenges","volume":"28","author":"Topkaya","year":"2016","journal-title":"Electroanalysis"},{"key":"ref_106","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.1021\/ac802092j","article-title":"Enrichment of Cancer Cells Using Aptamers Immobilized on a Microfluidic Channel","volume":"81","author":"Phillips","year":"2009","journal-title":"Anal. Chem."},{"key":"ref_107","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1016\/S0956-5663(00)00115-9","article-title":"Evaluation of antibody immobilization methods for piezoelectric biosensor application","volume":"15","author":"Babacan","year":"2000","journal-title":"Biosens. Bioelectron."},{"key":"ref_108","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1016\/j.ymeth.2005.05.005","article-title":"Piezoelectric biosensors: Strategies for coupling nucleic acids to piezoelectric devices","volume":"37","author":"Tombelli","year":"2005","journal-title":"Methods"},{"key":"ref_109","first-page":"19","article-title":"Genetic Alterations in Colorectal Cancer","volume":"5","author":"Armaghany","year":"2012","journal-title":"Gastrointest. Cancer Res."},{"key":"ref_110","first-page":"63","article-title":"An Overview on Infectious Disease","volume":"2","author":"Kumar","year":"2012","journal-title":"Indian J. Pharm. Sci. Res."},{"key":"ref_111","doi-asserted-by":"crossref","first-page":"128759","DOI":"10.1016\/j.cej.2021.128759","article-title":"Point of care detection of COVID-19: Advancement in biosensing and diagnostic methods","volume":"414","author":"Suleman","year":"2021","journal-title":"Chem. Eng. J."},{"key":"ref_112","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1016\/S0140-6736(03)13967-0","article-title":"Newly discovered coronavirus as the primary cause of severe acute respiratory syndrome","volume":"362","author":"Kuiken","year":"2003","journal-title":"Lancet"},{"key":"ref_113","unstructured":"Zhang, X., Qi, Q., Jing, Q., Ao, S., Zhang, Z., Ding, M., Wu, M., Liu, K., Wang, W., and Ling, Y. (2020). Electrical probing of COVID-19 spike protein receptor binding domain via a graphene field-effect transistor. arXiv, Available online: http:\/\/arxiv.org\/abs\/2003.12529."},{"key":"ref_114","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1007\/s00216-020-02958-1","article-title":"SARS-CoV-2 pandemic: A review of molecular diagnostic tools including sample collection and commercial response with associated advantages and limitations","volume":"413","author":"Jayamohan","year":"2021","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_115","doi-asserted-by":"crossref","first-page":"5268","DOI":"10.1021\/acsnano.0c02439","article-title":"Dual-Functional Plasmonic Photothermal Biosensors for Highly Accurate Severe Acute Respiratory Syndrome Coronavirus 2 Detection","volume":"14","author":"Qiu","year":"2020","journal-title":"ACS Nano"},{"key":"ref_116","doi-asserted-by":"crossref","first-page":"1178","DOI":"10.1021\/acsabm.0c01545","article-title":"Conventional and Nanotechnology-Based Sensing Methods for SARS Coronavirus (2019-nCoV)","volume":"4","author":"Shetti","year":"2021","journal-title":"ACS Appl. Bio Mater."},{"key":"ref_117","doi-asserted-by":"crossref","first-page":"100017","DOI":"10.1016\/j.snr.2020.100017","article-title":"Mini review: Recent progress in RT-LAMP enabled COVID-19 detection","volume":"2","author":"Thompson","year":"2020","journal-title":"Sens. Actuators Rep."},{"key":"ref_118","doi-asserted-by":"crossref","first-page":"112830","DOI":"10.1016\/j.bios.2020.112830","article-title":"Diagnosis of COVID-19 for controlling the pandemic: A review of the state-of-the-art","volume":"174","author":"Taleghani","year":"2021","journal-title":"Biosens. Bioelectron."},{"key":"ref_119","doi-asserted-by":"crossref","first-page":"17028","DOI":"10.1021\/acsnano.0c06392","article-title":"Rapid, ultrasensitive, and quantitative detection of SARS-CoV-2 using antisense oligonucleotides directed electrochemical biosensor chip","volume":"14","author":"Alafeef","year":"2020","journal-title":"ACS Nano"},{"key":"ref_120","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.procbio.2020.11.009","article-title":"Diagnostic approaches for the rapid detection of Zika virus\u2014A review","volume":"101","author":"Alam","year":"2021","journal-title":"Process Biochem."},{"key":"ref_121","first-page":"259","article-title":"Genosensor technology and the detection of interfacial nucleic acid chemistry","volume":"346","author":"Yang","year":"1997","journal-title":"Anal. Chim. Acta"},{"key":"ref_122","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1016\/j.bios.2017.03.046","article-title":"Localized surface plasmon resonance-mediated fluorescence signals in plasmonic nanoparticle-quantum dot hybrids for ultrasensitive Zika virus RNA detection via hairpin hybridization assays","volume":"94","author":"Adegoke","year":"2017","journal-title":"Biosens. Bioelectron."},{"key":"ref_123","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1002\/celc.201600831","article-title":"Unamplified RNA Sensor for On-Site Screening of Zika Virus Disease in a Limited Resource Setting","volume":"4","author":"Cheng","year":"2017","journal-title":"ChemElectroChem"},{"key":"ref_124","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1016\/j.bios.2019.02.018","article-title":"Label-free electrochemical DNA biosensor for zika virus identification","volume":"131","author":"Faria","year":"2019","journal-title":"Biosens. Bioelectron."},{"key":"ref_125","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/S0003-2670(97)00167-0","article-title":"Antibodies for immunosensors a review","volume":"347","author":"Hock","year":"1997","journal-title":"Anal. Chim. Acta"},{"key":"ref_126","doi-asserted-by":"crossref","first-page":"1700096","DOI":"10.1002\/adbi.201700096","article-title":"Rapid, Point-of-Care, Paper-Based Plasmonic Biosensor for Zika Virus Diagnosis","volume":"1","author":"Jiang","year":"2017","journal-title":"Adv. Biosyst."},{"key":"ref_127","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1038\/s41598-018-28035-3","article-title":"A sensitive electrochemical immunosensor for label-free detection of Zika-virus protein","volume":"8","author":"Kaushik","year":"2018","journal-title":"Sci. Rep."},{"key":"ref_128","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/j.talanta.2019.04.080","article-title":"Early diagnosis of Zika infection using a ZnO nanostructures-based rapid electrochemical biosensor","volume":"203","author":"Faria","year":"2019","journal-title":"Talanta"},{"key":"ref_129","doi-asserted-by":"crossref","unstructured":"Takemura, K., Adegoke, O., Suzuki, T., and Park, E.Y. (2019). A localized surface plasmon resonance-amplified immunofluorescence biosensor for ultrasensitive and rapid detection of nonstructural protein 1 of Zika virus. PLoS ONE, 14.","DOI":"10.1371\/journal.pone.0211517"},{"key":"ref_130","doi-asserted-by":"crossref","first-page":"1551","DOI":"10.1039\/C5AN01824B","article-title":"Aptamers in analytics","volume":"141","author":"Ilgu","year":"2016","journal-title":"Analyst"},{"key":"ref_131","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1038\/nri1706","article-title":"Perils at mucosal front lines for HIV and SIV and their hosts","volume":"5","author":"Haase","year":"2005","journal-title":"Nat. Rev. Immunol."},{"key":"ref_132","doi-asserted-by":"crossref","first-page":"763","DOI":"10.1038\/312763a0","article-title":"The CD4 (T4) antigen is an essential component of the receptor for the AIDS retrovirus","volume":"312","author":"Dalgleish","year":"1984","journal-title":"Nature"},{"key":"ref_133","unstructured":"World Health Organization (2004). Patient Monitoring Guidelines for HIV Care and Antiretroviral Therapy."},{"key":"ref_134","doi-asserted-by":"crossref","first-page":"2121","DOI":"10.1039\/b811131f","article-title":"A polymer lab-on-a-chip for reverse transcription (RT)-PCR based point-of-care clinical diagnostics","volume":"8","author":"Lee","year":"2008","journal-title":"Lab Chip"},{"key":"ref_135","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1039\/B713695A","article-title":"Ultra wide-field lens-free monitoring of cells on-chip","volume":"8","author":"Ozcan","year":"2007","journal-title":"Lab Chip"},{"key":"ref_136","unstructured":"Moon, S.J., Keles, H.O., Kim, Y.-G., Kuritzkes, D., and Demirci, U. (2009, January 3\u20136). Lensless imaging for point-of-care testing. Proceedings of the 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Minneapolis, MN, USA."},{"key":"ref_137","doi-asserted-by":"crossref","first-page":"100006","DOI":"10.1016\/j.bea.2021.100006","article-title":"Analytical methods for detection of human cytomegalovirus clinched biosensor a cutting-edge diagnostic tool","volume":"1","author":"Hasan","year":"2021","journal-title":"Biomed. Eng. Adv."},{"key":"ref_138","doi-asserted-by":"crossref","unstructured":"Sun, H., Qi, C., Niu, Y., Kang, T., Wei, Y., Jin, G., Dong, X., Wang, C., and Zhu, W. (2015). Detection of Cytomegalovirus Antibodies Using a Biosensor Based on Imaging Ellipsometry. PLoS ONE, 10.","DOI":"10.1371\/journal.pone.0136253"},{"key":"ref_139","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.ab.2004.06.008","article-title":"Studies of substrate-induced conformational changes in human cytomegalovirus protease using optical biosensor technology","volume":"332","author":"Geitmann","year":"2004","journal-title":"Anal. Biochem."},{"key":"ref_140","doi-asserted-by":"crossref","first-page":"2559","DOI":"10.1016\/j.ijbiomac.2017.10.146","article-title":"Portable bioactive paper based genosensor incorporated with Zn-Ag nanoblooms for herpes detection at the point-of-care","volume":"107","author":"Narang","year":"2018","journal-title":"Int. J. Biol. Macromol."},{"key":"ref_141","doi-asserted-by":"crossref","first-page":"16076","DOI":"10.1038\/nrdp.2016.76","article-title":"Tuberculosis","volume":"2","author":"Pai","year":"2016","journal-title":"Nat. Rev. Dis. Prim."},{"key":"ref_142","doi-asserted-by":"crossref","first-page":"e20200483","DOI":"10.1590\/1980-5373-mr-2020-0483","article-title":"Novel Biosensor Detection of Tuberculosis Based on Photonic Band Gap Materials","volume":"24","author":"Aly","year":"2021","journal-title":"Mater. Res."},{"key":"ref_143","doi-asserted-by":"crossref","first-page":"e06321","DOI":"10.1016\/j.heliyon.2021.e06321","article-title":"Recent progress in surface plasmon resonance based sensors: A comprehensive review","volume":"7","author":"Yesudasu","year":"2021","journal-title":"Heliyon"},{"key":"ref_144","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1016\/j.biortech.2017.12.095","article-title":"Pathway and mechanism of nitrogen transformation during composting: Functional enzymes and genes under different concentrations of PVP-AgNPs","volume":"253","author":"Zeng","year":"2018","journal-title":"Bioresour. Technol."},{"key":"ref_145","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1007\/s00216-003-1912-3","article-title":"Electrochemical immunosensor for Forest-Spring encephalitis based on protein A labeled with colloidal gold","volume":"376","author":"Brainina","year":"2003","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_146","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.aca.2004.10.072","article-title":"A label-free amperometric immunosenor based on multi-layer assembly of polymerized o-phenylenediamine and gold nanoparticles for determination of Japanese B encephalitis vaccine","volume":"531","author":"Yuan","year":"2005","journal-title":"Anal. Chim. Acta"},{"key":"ref_147","doi-asserted-by":"crossref","first-page":"1385","DOI":"10.1016\/S0956-5663(03)00066-6","article-title":"An ultrasensitive and stable potentiometric immunosensor","volume":"18","author":"Purvis","year":"2003","journal-title":"Biosens. Bioelectron."},{"key":"ref_148","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1016\/0022-1759(93)90336-6","article-title":"Rapid immunofiltration assay of Newcastle disease virus using a silicon sensor","volume":"166","author":"Lee","year":"1993","journal-title":"J. Immunol. Methods"},{"key":"ref_149","doi-asserted-by":"crossref","first-page":"1079","DOI":"10.1039\/b603402k","article-title":"The role of biosensors in the detection of emerging infectious diseases","volume":"131","author":"Pejcic","year":"2006","journal-title":"Analyst"},{"key":"ref_150","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.bioelechem.2004.05.004","article-title":"A novel immunosensor based on immobilization of hepatitis B surface antibody on platinum electrode modified colloidal gold and polyvinyl butyral as matrices via electrochemical impedance spectroscopy","volume":"65","author":"Tang","year":"2004","journal-title":"Bioelectrochemistry"},{"key":"ref_151","doi-asserted-by":"crossref","first-page":"757","DOI":"10.1109\/JSEN.2005.846377","article-title":"Rapid detection of bovine viral diarrhea virus as surrogate of bioterrorism agents","volume":"5","author":"Alocilja","year":"2005","journal-title":"IEEE Sens. J."},{"key":"ref_152","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1139\/v96-076","article-title":"Detection of Newcastle disease virus using an evanescent wave immuno-based biosensor","volume":"74","author":"Lee","year":"1996","journal-title":"Can. J. Chem."},{"key":"ref_153","doi-asserted-by":"crossref","first-page":"3768","DOI":"10.1039\/C4NR06687A","article-title":"An ultra-sensitive impedimetric immunosensor for detection of the serum oncomarker CA-125 in ovarian cancer patients","volume":"7","author":"Rashidi","year":"2015","journal-title":"Nanoscale"},{"key":"ref_154","doi-asserted-by":"crossref","first-page":"920","DOI":"10.1016\/j.bios.2016.07.014","article-title":"Dual-responsive immunosensor that combines colorimetric recognition and electrochemical response for ultrasensitive detection of cancer biomarkers","volume":"86","author":"Hong","year":"2016","journal-title":"Biosens. Bioelectron."},{"key":"ref_155","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1186\/s11671-018-2632-0","article-title":"A Novel Magnetoelastic Immunosensor for Ultrasensitively Detecting Carcinoembryonic Antigen","volume":"13","author":"Zhang","year":"2018","journal-title":"Nanoscale Res. Lett."},{"key":"ref_156","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/j.snb.2017.10.049","article-title":"Sensitive on-chip detection of cancer antigen 125 using a DNA aptamer\/carbon nanotube network platform","volume":"256","author":"Gedi","year":"2018","journal-title":"Sensors Actuators B Chem."},{"key":"ref_157","doi-asserted-by":"crossref","first-page":"5135","DOI":"10.1021\/acsnano.0c02823","article-title":"Rapid Detection of COVID-19 Causative Virus (SARS-CoV-2) in Human Nasopharyngeal Swab Specimens Using Field-Effect Transistor-Based Biosensor","volume":"14","author":"Seo","year":"2020","journal-title":"ACS Nano"},{"key":"ref_158","doi-asserted-by":"crossref","first-page":"3412","DOI":"10.1016\/j.bios.2009.06.012","article-title":"Real-time monitoring of the strand displacement amplification (SDA) of human cytomegalovirus by a new SDA-piezoelectric DNA sensor system","volume":"24","author":"Chen","year":"2009","journal-title":"Biosens. Bioelectron."},{"key":"ref_159","doi-asserted-by":"crossref","first-page":"15224","DOI":"10.1039\/C9NR01075K","article-title":"Antifolate SERS-active nanovectors: Quantitative drug nanostructuring and selective cell targeting for effective theranostics","volume":"11","author":"Fasolato","year":"2019","journal-title":"Nanoscale"},{"key":"ref_160","doi-asserted-by":"crossref","first-page":"413","DOI":"10.3389\/fchem.2019.00413","article-title":"Exploring the Potentiality of a SERS-Active pH Nano-Biosensor","volume":"7","author":"Capocefalo","year":"2019","journal-title":"Front. Chem."},{"key":"ref_161","doi-asserted-by":"crossref","unstructured":"Capocefalo, A., Bizien, T., Sennato, S., Ghofraniha, N., Bordi, F., and Brasili, F. (2022). Responsivity of Fractal Nanoparticle Assemblies to Multiple Stimuli: Structural Insights on the Modulation of the Optical Properties. Nanomaterials, 12.","DOI":"10.3390\/nano12091529"},{"key":"ref_162","doi-asserted-by":"crossref","first-page":"17080","DOI":"10.1038\/natrevmats.2017.80","article-title":"Nanomaterials for in vivo imaging of mechanical forces and electrical fields","volume":"3","author":"Mehlenbacher","year":"2017","journal-title":"Nat. Rev. Mater."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/11\/4228\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T23:23:29Z","timestamp":1760138609000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/11\/4228"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,1]]},"references-count":162,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2022,6]]}},"alternative-id":["s22114228"],"URL":"https:\/\/doi.org\/10.3390\/s22114228","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6,1]]}}}