{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T10:37:17Z","timestamp":1781347037149,"version":"3.54.1"},"reference-count":65,"publisher":"MDPI AG","issue":"13","license":[{"start":{"date-parts":[[2022,6,23]],"date-time":"2022-06-23T00:00:00Z","timestamp":1655942400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>There is a growing research interest in wireless non-invasive solutions for core temperature estimation and their application in clinical settings. This study aimed to investigate the use of a novel wireless non-invasive heat flux-based thermometer in acute stroke patients admitted to a stroke unit and compare the measurements with the currently used infrared (IR) tympanic temperature readings. The study encompassed 30 acute ischemic stroke patients who underwent continuous measurement (Tcore) with the novel wearable non-invasive CORE device. Paired measurements of Tcore and tympanic temperature (Ttym) by using a standard IR-device were performed 3\u20135 times\/day, yielding a total of 305 measurements. The predicted core temperatures (Tcore) were significantly correlated with Ttym (r = 0.89, p &lt; 0.001). The comparison of the Tcore and Ttym measurements by Bland\u2013Altman analysis showed a good agreement between them, with a low mean difference of 0.11 \u00b1 0.34 \u00b0C, and no proportional bias was observed (B = \u22120.003, p = 0.923). The Tcore measurements correctly predicted the presence or absence of Ttym hyperthermia or fever in 94.1% and 97.4% of cases, respectively. Temperature monitoring with a novel wireless non-invasive heat flux-based thermometer could be a reliable alternative to the Ttym method for assessing core temperature in acute ischemic stroke patients.<\/jats:p>","DOI":"10.3390\/s22134760","type":"journal-article","created":{"date-parts":[[2022,6,23]],"date-time":"2022-06-23T22:43:00Z","timestamp":1656024180000},"page":"4760","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":31,"title":["A Novel Non-Invasive Thermometer for Continuous Core Body Temperature: Comparison with Tympanic Temperature in an Acute Stroke Clinical Setting"],"prefix":"10.3390","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8307-4360","authenticated-orcid":false,"given":"Milo\u0161","family":"Aj\u010devi\u0107","sequence":"first","affiliation":[{"name":"Clinical Unit of Neurology, Department of Medicine, Surgery and Health Sciences, Cattinara University Hospital ASUGI, University of Trieste, Strada di Fiume, 447-34149 Trieste, Italy"},{"name":"Department of Engineering and Architecture, University of Trieste, Via A. Valerio, 10-34127 Trieste, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4871-7022","authenticated-orcid":false,"given":"Alex","family":"Buoite Stella","sequence":"additional","affiliation":[{"name":"Clinical Unit of Neurology, Department of Medicine, Surgery and Health Sciences, Cattinara University Hospital ASUGI, University of Trieste, Strada di Fiume, 447-34149 Trieste, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9954-0239","authenticated-orcid":false,"given":"Giovanni","family":"Furlanis","sequence":"additional","affiliation":[{"name":"Clinical Unit of Neurology, Department of Medicine, Surgery and Health Sciences, Cattinara University Hospital ASUGI, University of Trieste, Strada di Fiume, 447-34149 Trieste, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paola","family":"Caruso","sequence":"additional","affiliation":[{"name":"Clinical Unit of Neurology, Department of Medicine, Surgery and Health Sciences, Cattinara University Hospital ASUGI, University of Trieste, Strada di Fiume, 447-34149 Trieste, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcello","family":"Naccarato","sequence":"additional","affiliation":[{"name":"Clinical Unit of Neurology, Department of Medicine, Surgery and Health Sciences, Cattinara University Hospital ASUGI, University of Trieste, Strada di Fiume, 447-34149 Trieste, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5749-6308","authenticated-orcid":false,"given":"Agostino","family":"Accardo","sequence":"additional","affiliation":[{"name":"Department of Engineering and Architecture, University of Trieste, Via A. Valerio, 10-34127 Trieste, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paolo","family":"Manganotti","sequence":"additional","affiliation":[{"name":"Clinical Unit of Neurology, Department of Medicine, Surgery and Health Sciences, Cattinara University Hospital ASUGI, University of Trieste, Strada di Fiume, 447-34149 Trieste, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,6,23]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.jinf.2019.11.003","article-title":"Ingestible Sensors Correlate Closely with Peripheral Temperature Measurements in Febrile Patients","volume":"80","author":"Huang","year":"2020","journal-title":"J. Infect."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"094001","DOI":"10.1088\/1361-6579\/ab2af6","article-title":"Bilateral Assessment of Body Core Temperature through Axillar, Tympanic and Inner Canthi Thermometers in a Young Population","volume":"40","author":"Vardasca","year":"2019","journal-title":"Physiol. Meas."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1007\/s13534-019-00102-2","article-title":"Thermometry and Interpretation of Body Temperature","volume":"9","author":"Chen","year":"2019","journal-title":"Biomed. Eng. Lett."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1016\/B978-0-444-64074-1.00029-X","article-title":"Body Temperature and Clinical Thermometry","volume":"157","author":"Childs","year":"2018","journal-title":"Handb. Clin. Neurol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/j.jtherbio.2014.10.006","article-title":"Considerations for the Measurement of Core, Skin and Mean Body Temperatures","volume":"46","author":"Taylor","year":"2014","journal-title":"J. Therm. Biol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1093\/bja\/aep134","article-title":"Accuracy and Precision of a Novel Non-Invasive Core Thermometer","volume":"103","author":"Kimberger","year":"2009","journal-title":"Br. J. Anaesth."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1071","DOI":"10.1007\/s11739-020-02556-0","article-title":"The Diagnostic Accuracy of Digital, Infrared and Mercury-in-Glass Thermometers in Measuring Body Temperature: A Systematic Review and Network Meta-Analysis","volume":"16","author":"Pecoraro","year":"2021","journal-title":"Intern. Emerg. Med."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1080\/03091902.2020.1822941","article-title":"Return to School in the COVID-19 Era: Considerations for Temperature Measurement","volume":"44","author":"Manganotti","year":"2020","journal-title":"J. Med. Eng. Technol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"768","DOI":"10.7326\/M15-1150","article-title":"Accuracy of Peripheral Thermometers for Estimating Temperature: A Systematic Review and Meta-Analysis","volume":"163","author":"Niven","year":"2015","journal-title":"Ann. Intern. Med."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Diamond, A., Lye, C.T., Prasad, D., and Abbott, D. (2021). One Size Does Not Fit All: Assuming the Same Normal Body Temperature for Everyone Is Not Justified. PLoS ONE, 16.","DOI":"10.1371\/journal.pone.0259428"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"ofz032","DOI":"10.1093\/ofid\/ofz032","article-title":"Normal Body Temperature: A Systematic Review","volume":"6","author":"Geneva","year":"2019","journal-title":"Open Forum Infect. Dis."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1330","DOI":"10.1097\/CCM.0b013e318169eda9","article-title":"Guidelines for Evaluation of New Fever in Critically Ill Adult Patients: 2008 Update from the American College of Critical Care Medicine and the Infectious Diseases Society of America","volume":"36","author":"Barie","year":"2008","journal-title":"Crit. Care Med."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"306","DOI":"10.4103\/joacp.JOACP_334_16","article-title":"Temperature Management under General Anesthesia: Compulsion or Option","volume":"33","author":"Bindu","year":"2017","journal-title":"J. Anaesthesiol. Clin. Pharmacol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"553","DOI":"10.1016\/S0022-3476(98)70067-8","article-title":"Comparison of Esophageal, Rectal, Axillary, Bladder, Tympanic, and Pulmonary Artery Temperatures in Children","volume":"133","author":"Robinson","year":"1998","journal-title":"J. Pediatr."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1007\/s00134-002-1619-5","article-title":"Temperature Measurement in Intensive Care Patients: Comparison of Urinary Bladder, Oesophageal, Rectal, Axillary, and Inguinal Methods versus Pulmonary Artery Core Method","volume":"29","author":"Lefrant","year":"2003","journal-title":"Intensive Care Med."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"S273-8","DOI":"10.1097\/CCM.0b013e3181aa6117","article-title":"Fever in the Critically Ill Medical Patient","volume":"37","author":"Laupland","year":"2009","journal-title":"Crit. Care Med."},{"key":"ref_17","first-page":"389","article-title":"Admission Body Temperature in Critically Ill Patients as an Independent Risk Predictor for Overall Outcome","volume":"29","author":"Erkens","year":"2020","journal-title":"Med. Princ. Pract. Int. J. Kuwait Univ. Health Sci. Cent."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1085","DOI":"10.1592\/phco.31.11.1085","article-title":"Treatment of Fever after Stroke: Conflicting Evidence","volume":"31","author":"Wrotek","year":"2011","journal-title":"Pharmacotherapy"},{"key":"ref_19","first-page":"313","article-title":"Management of Fever, Hyperglycemia, and Dysphagia in an Acute Stroke Unit","volume":"41","author":"Kenny","year":"2016","journal-title":"Rehabil. Nurs. Off. J. Assoc. Rehabil. Nurses"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1159\/000099133","article-title":"The Main Components of Stroke Unit Care: Results of a European Expert Survey","volume":"23","author":"Leys","year":"2007","journal-title":"Cerebrovasc. Dis."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1007\/s10877-020-00543-6","article-title":"Accuracy and Precision of Zero-Heat-Flux Temperature Measurements with the 3MTM Bair HuggerTM Temperature Monitoring System: A Systematic Review and Meta-Analysis","volume":"35","author":"Conway","year":"2021","journal-title":"J. Clin. Monit. Comput."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.jtherbio.2017.03.007","article-title":"Measuring Core Body Temperature with a Non-Invasive Sensor","volume":"66","author":"Mazgaoker","year":"2017","journal-title":"J. Therm. Biol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"22079","DOI":"10.1038\/s41598-021-99300-1","article-title":"Clinical evaluation of non-contact infrared thermometers","volume":"11","author":"Sullivan","year":"2021","journal-title":"Sci. Rep."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"11832","DOI":"10.1038\/s41598-021-90100-1","article-title":"Proper use of noncontact infrared thermometry for temperature screening during COVID-19","volume":"11","author":"Hussain","year":"2021","journal-title":"Sci. Rep."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"447","DOI":"10.2147\/RMHP.S357567","article-title":"Reliability of Non-Contact Infrared Thermometers for Fever Screening Under COVID-19","volume":"15","author":"Lai","year":"2022","journal-title":"Risk Manag. Healthc. Policy"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"S63","DOI":"10.1016\/j.resp.2009.04.005","article-title":"The Double Sensor-A Non-Invasive Device to Continuously Monitor Core Temperature in Humans on Earth and in Space","volume":"169","author":"Gunga","year":"2009","journal-title":"Respir. Physiol. Neurobiol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1179\/174313208X300422","article-title":"Risk Factors for Fever in Critically Ill Patients with Acute New-Onset Stroke","volume":"30","author":"Yan","year":"2008","journal-title":"Neurol. Res."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1111\/j.1365-2796.2006.01694.x","article-title":"Hyperthermia Is a Surrogate Marker of Inflammation-Mediated Cause of Brain Damage in Acute Ischaemic Stroke","volume":"260","author":"Leira","year":"2006","journal-title":"J. Intern. Med."},{"key":"ref_29","unstructured":"Khan, S., Ali, S., Khan, A., and Bermak, A. (2021). Wearable Printed Temperature Sensors: Short Review on Latest Advances for Biomedical Applications. IEEE Rev. Biomed. Eng., Early Access."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"2158","DOI":"10.1109\/JBHI.2021.3124551","article-title":"Wearable Personal Core Body Temperature Measurement Considering Individual Differences and Dynamic Tissue Blood Perfusion","volume":"26","author":"Shan","year":"2021","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Chaglla, E.J.S., Celik, N., and Balachandran, W. (2018). Measurement of Core Body Temperature Using Graphene-Inked Infrared Thermopile Sensor. Sensors, 18.","DOI":"10.3390\/s18103315"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1097\/00000539-200207000-00012","article-title":"Insufficiency in a new temporal-artery thermometer for adult and pediatric patients","volume":"95","author":"Suleman","year":"2002","journal-title":"Anesth. Analg."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1042","DOI":"10.1213\/01.ane.0000281927.88935.e0","article-title":"Temporal artery versus bladder thermometry during perioperative and intensive care unit monitoring","volume":"105","author":"Kimberger","year":"2007","journal-title":"Anesth. Analg."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1097\/01.CCM.0000250318.31453.CB","article-title":"Tympanic temperature measurements: Are they reliable in the critically ill? A clinical study of measures of agreement","volume":"35","author":"Moran","year":"2007","journal-title":"Crit. Care Med."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"985","DOI":"10.1097\/00000542-199112000-00010","article-title":"Isoflurane anesthesia and circadian temperature cycles in humans","volume":"75","author":"Sessler","year":"1991","journal-title":"Anesthesiology"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1007\/s004240050530","article-title":"Circadian changes in the sweating-to-vasoconstriction interthreshold range","volume":"435","author":"Tayefeh","year":"1998","journal-title":"Pflug. Archiv. Eur. J. Physiol."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"102788","DOI":"10.1016\/j.jtherbio.2020.102788","article-title":"Assessing Rectal Temperature with a Novel Non-Invasive Sensor","volume":"95","author":"Tsadok","year":"2021","journal-title":"J. Therm. Biol."},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Moyen, N.E., Bapat, R.C., Tan, B., Hunt, L.A., Jay, O., and M\u00fcndel, T. (2021). Accuracy of Algorithm to Non-Invasively Predict Core Body Temperature Using the Kenzen Wearable Device. Int. J. Environ. Res. Public Health, 18.","DOI":"10.3390\/ijerph182413126"},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Verdel, N., Podlogar, T., Ciuha, U., Holmberg, H.-C., Debevec, T., and Supej, M. (2021). Reliability and Validity of the CORE Sensor to Assess Core Body Temperature during Cycling Exercise. Sensors, 21.","DOI":"10.3390\/s21175932"},{"key":"ref_40","first-page":"OC43","article-title":"Comparison of Conventional Mercury Thermometer and Continuous TherCom(\u00ae) Temperature Recording in Hospitalized Patients","volume":"10","author":"Dakappa","year":"2016","journal-title":"J. Clin. Diagn. Res."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"e039474","DOI":"10.1136\/bmjopen-2020-039474","article-title":"Evaluation of a Wearable Wireless Device with Artificial Intelligence, IThermonitor WT705, for Continuous Temperature Monitoring for Patients in Surgical Wards: A Prospective Comparative Study","volume":"10","author":"Liu","year":"2020","journal-title":"BMJ Open"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"2700407","DOI":"10.1109\/JTEHM.2021.3098127","article-title":"A Novel Wearable Device for Continuous Temperature Monitoring & Fever Detection","volume":"9","author":"Verma","year":"2021","journal-title":"IEEE J. Transl. Eng. Health Med."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1007\/s00484-020-02044-2","article-title":"Heat Risk Exacerbation Potential for Neurology Patients during the COVID-19 Pandemic and Related Isolation","volume":"65","author":"Filingeri","year":"2021","journal-title":"Int. J. Biometeorol."},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Kagiyama, N., Hiki, M., Matsue, Y., Dohi, T., Matsuzawa, W., Daida, H., Minamino, T., and Kasai, T. (2021). Validation of Telemedicine-Based Self-Assessment of Vital Signs for Patients with COVID-19: A Pilot Study. J. Telemed. Telecare, 1357633X211011825.","DOI":"10.1177\/1357633X211011825"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"104442","DOI":"10.1016\/j.ijmedinf.2021.104442","article-title":"E-Health Solution for Home Patient Telemonitoring in Early Post-Acute TIA\/Minor Stroke during COVID-19 Pandemic","volume":"152","author":"Furlanis","year":"2021","journal-title":"Int. J. Med. Inform."},{"key":"ref_46","first-page":"3479","article-title":"Comprehensive Telemedicine Solution for Remote Monitoring of Parkinson\u2019s Disease Patients with Orthostatic Hypotension during COVID-19 Pandemic","volume":"43","author":"Polverino","year":"2022","journal-title":"Neurol. Sci. Off. J. Ital. Neurol. Soc. Ital. Soc. Clin. Neurophysiol."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"2911","DOI":"10.1161\/STROKEAHA.109.192362","article-title":"Comprehensive Overview of Nursing and Interdisciplinary Care of the Acute Ischemic Stroke Patient: A Scientific Statement from the American Heart Association","volume":"40","author":"Summers","year":"2009","journal-title":"Stroke"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"e98","DOI":"10.1161\/STROKEAHA.115.008188","article-title":"Evidence-Base for Fever Interventions Following Stroke","volume":"46","author":"Thompson","year":"2015","journal-title":"Stroke"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"699","DOI":"10.1088\/0967-3334\/25\/5\/C01","article-title":"IR Ear Thermometers: What Do They Measure and How Do They Comply with the EU Technical Regulation?","volume":"25","author":"Pusnik","year":"2004","journal-title":"Physiol. Meas."},{"key":"ref_50","doi-asserted-by":"crossref","unstructured":"Dell\u2019Isola, G.B., Cosentini, E., Canale, L., Ficco, G., and Dell\u2019Isola, M. (2021). Noncontact Body Temperature Measurement: Uncertainty Evaluation and Screening Decision Rule to Prevent the Spread of COVID-19. Sensors, 21.","DOI":"10.3390\/s21020346"},{"key":"ref_51","first-page":"142","article-title":"Clinical Accuracy of Non-Contact Forehead Infrared Thermometer and Infrared Tympanic Thermometer in Postoperative Adult Patients: A Comparative Study","volume":"32","author":"Kameda","year":"2021","journal-title":"J. Perioper. Pract."},{"key":"ref_52","doi-asserted-by":"crossref","unstructured":"Mekjavic, I.B., and Tipton, M.J. (2020). Myths and Methodologies: Degrees of Freedom\u2014Limitations of Infrared Thermographic Screening for Covid-19 and Other Infections. Exp. Physiol., Early View.","DOI":"10.1113\/EP089260"},{"key":"ref_53","doi-asserted-by":"crossref","unstructured":"Mogensen, C.B., Wittenhoff, L., Fruerh\u00f8j, G., and Hansen, S. (2018). Forehead or Ear Temperature Measurement Cannot Replace Rectal Measurements, except for Screening Purposes. BMC Pediatr., 18.","DOI":"10.1186\/s12887-018-0994-1"},{"key":"ref_54","doi-asserted-by":"crossref","unstructured":"Chen, H.Y., Chen, A., and Chen, C. (2020). Investigation of the Impact of Infrared Sensors on Core Body Temperature Monitoring by Comparing Measurement Sites. Sensors, 20.","DOI":"10.3390\/s20102885"},{"key":"ref_55","doi-asserted-by":"crossref","unstructured":"Dwith Chenna, Y.N., Ghassemi, P., Pfefer, T.J., Casamento, J., and Wang, Q. (2018). Free-Form Deformation Approach for Registration of Visible and Infrared Facial Images in Fever Screening. Sensors, 18.","DOI":"10.3390\/s18010125"},{"key":"ref_56","doi-asserted-by":"crossref","unstructured":"Silawan, N., Kusukame, K., Kek, K.J., and Kuan, W.S. (2018, January 18\u201321). A Novel Environment-Invariant Core Body Temperature Estimation for High Sensitivity and Specificity Fever Screening. Proceedings of the 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Honolulu, HI, USA.","DOI":"10.1109\/EMBC.2018.8512541"},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"1351","DOI":"10.1007\/s10877-019-00446-1","article-title":"Perioperative measurement of core body temperature using an unobtrusive passive heat flow sensor","volume":"34","author":"Atallah","year":"2020","journal-title":"J. Clin. Monit. Comput."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1088\/0967-3334\/32\/5\/005","article-title":"Non-Invasive Continuous Core Temperature Measurement by Zero Heat Flux","volume":"32","author":"Teunissen","year":"2011","journal-title":"Physiol. Meas."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"25004","DOI":"10.1088\/1361-6579\/aaf0c1","article-title":"Validation of Non-Invasive Brain Temperature Estimation Models during Swine Therapeutic Hypothermia","volume":"40","author":"Sung","year":"2019","journal-title":"Physiol. Meas."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"1121","DOI":"10.1007\/s10877-019-00411-y","article-title":"Zero-Heat-Flux Core Temperature Monitoring System: An Observational Secondary Analysis to Evaluate Agreement with Naso-\/Oropharyngeal Probe during Anesthesia","volume":"34","author":"West","year":"2020","journal-title":"J. Clin. Monit. Comput."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1042\/cs0440081","article-title":"A new method for monitoring deep body temperature from the skin surface","volume":"44","author":"Fox","year":"1973","journal-title":"Clin. Sci."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"21746","DOI":"10.1038\/s41598-020-78753-w","article-title":"Accuracy of zero-heat-flux thermometry and bladder temperature measurement in critically ill patients","volume":"10","author":"Fazliu","year":"2020","journal-title":"Sci. Rep."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1097\/EJA.0000000000000232","article-title":"Intraoperative temperature monitoring with zero heat flux technology (3M SpotOn sensor) in comparison with sublingual and nasopharyngeal temperature: An observational study","volume":"32","author":"Iden","year":"2015","journal-title":"Eur. J. Anaesthesiol."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"973","DOI":"10.1053\/j.jvca.2016.03.141","article-title":"Novel Zero-Heat-Flux Deep Body Temperature Measurement in Lower Extremity Vascular and Cardiac Surgery","volume":"30","author":"Pesonen","year":"2016","journal-title":"J. Cardiothorac. Vasc. Anesth."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1109\/JBHI.2014.2385103","article-title":"Unobtrusive monitoring of neonatal brain temperature using a zero-heat-flux sensor matrix","volume":"20","author":"Atallah","year":"2016","journal-title":"IEEE J. Biomed. Health Inform."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/13\/4760\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T23:38:59Z","timestamp":1760139539000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/13\/4760"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,23]]},"references-count":65,"journal-issue":{"issue":"13","published-online":{"date-parts":[[2022,7]]}},"alternative-id":["s22134760"],"URL":"https:\/\/doi.org\/10.3390\/s22134760","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6,23]]}}}