{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,16]],"date-time":"2026-01-16T12:16:47Z","timestamp":1768565807297,"version":"3.49.0"},"reference-count":22,"publisher":"MDPI AG","issue":"13","license":[{"start":{"date-parts":[[2022,6,29]],"date-time":"2022-06-29T00:00:00Z","timestamp":1656460800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"European Union\u2019s Horizon 2020 research and innovation program","award":["824984"],"award-info":[{"award-number":["824984"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A novel wearable smart patch can monitor various aspects of physical activity, including the dynamics of running, but like any new device developed for such applications, it must first be tested for validity. Here, we compare the step rate while running in place as measured by this smart patch to the corresponding values obtained utilizing \u2018\u2018gold standard\u2019\u2019 MEMS accelerometers in combination with bilateral force plates equipped with HBM load cells, as well as the values provided by a three-dimensional motion capture system and the Garmin Dynamics Running Pod. The 15 healthy, physically active volunteers (age = 23 \u00b1 3 years; body mass = 74 \u00b1 17 kg, height = 176 \u00b1 10 cm) completed three consecutive 20-s bouts of running in place, starting at low, followed by medium, and finally at high intensity, all self-chosen. Our major findings are that the rates of running in place provided by all four systems were valid, with the notable exception of the fast step rate as measured by the Garmin Running Pod. The lowest mean bias and LoA for these measurements at all rates were associated consistently with the smart patch.<\/jats:p>","DOI":"10.3390\/s22134897","type":"journal-article","created":{"date-parts":[[2022,6,29]],"date-time":"2022-06-29T22:43:28Z","timestamp":1656542608000},"page":"4897","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["A Comparison of a Novel Stretchable Smart Patch for Measuring Runner\u2019s Step Rates with Existing Measuring Technologies"],"prefix":"10.3390","volume":"22","author":[{"given":"Nina","family":"Verdel","sequence":"first","affiliation":[{"name":"Department of Health Sciences, Mid Sweden University, 83125 \u00d6stersund, Sweden"},{"name":"Faculty of Sport, University of Ljubljana, 1000 Ljubljana, Slovenia"}]},{"given":"Miha","family":"Drobni\u010d","sequence":"additional","affiliation":[{"name":"Faculty of Sport, University of Ljubljana, 1000 Ljubljana, Slovenia"}]},{"given":"Jan","family":"Maslik","sequence":"additional","affiliation":[{"name":"Department of Materials Science and Engineering, Uppsala University, 75121 Uppsala, Sweden"}]},{"given":"Klara","family":"Bj\u00f6rnander Rahimi","sequence":"additional","affiliation":[{"name":"Department of Materials Science and Engineering, Uppsala University, 75121 Uppsala, Sweden"}]},{"given":"Giorgio","family":"Tantillo","sequence":"additional","affiliation":[{"name":"STMicroelectronics, 20864 Agrate Brianza, Italy"}]},{"given":"Alessandro","family":"Gumiero","sequence":"additional","affiliation":[{"name":"STMicroelectronics, 20864 Agrate Brianza, Italy"}]},{"given":"Klas","family":"Hjort","sequence":"additional","affiliation":[{"name":"Department of Materials Science and Engineering, Uppsala University, 75121 Uppsala, Sweden"}]},{"given":"Hans-Christer","family":"Holmberg","sequence":"additional","affiliation":[{"name":"Department of Health Sciences, Lule\u00e5 University of Technology, 97187 Lulea, Sweden"},{"name":"Department of Physiology and Pharmacology, Karolinska Institutet, 17177 Stockholm, Sweden"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7231-7002","authenticated-orcid":false,"given":"Matej","family":"Supej","sequence":"additional","affiliation":[{"name":"Department of Health Sciences, Mid Sweden University, 83125 \u00d6stersund, Sweden"},{"name":"Faculty of Sport, University of Ljubljana, 1000 Ljubljana, Slovenia"}]}],"member":"1968","published-online":{"date-parts":[[2022,6,29]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"104991","DOI":"10.1016\/j.clinbiomech.2020.104991","article-title":"Biomechanical Risk Factors for Running-Related Injury Differ by Sample Population: A Systematic Review and Meta-Analysis","volume":"75","author":"Vannatta","year":"2020","journal-title":"Clin. Biomech."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1260\/1747-9541.7.1.57","article-title":"Classifying Training Drills Based on Movement Demands in Australian Football","volume":"7","author":"Loader","year":"2012","journal-title":"Int. J. Sports Sci. Coach."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"973","DOI":"10.1519\/JSC.0b013e3181d09dde","article-title":"Reliability and Validity of a Novel Intermittent Peak Running Speed Test for Australian Football","volume":"25","author":"Mooney","year":"2011","journal-title":"J. Strength Cond. Res."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1080\/02640414.2011.627941","article-title":"Validity and Reliability of GPS for Measuring Instantaneous Velocity during Acceleration, Deceleration, and Constant Motion","volume":"30","author":"Varley","year":"2012","journal-title":"J. Sports Sci."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"906","DOI":"10.1519\/JSC.0b013e3181aeb11a","article-title":"Heart Rate Responses to Small-Sided Games among Elite Junior Rugby League Players","volume":"24","author":"Foster","year":"2010","journal-title":"J. Strength Cond. Res."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"744","DOI":"10.5435\/00124635-201212000-00002","article-title":"Heat- and Cold-Induced Injuries in Athletes: Evaluation and Management","volume":"20","author":"Noonan","year":"2012","journal-title":"J. Am. Acad. Orthop. Surg."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1177\/1941738115616917","article-title":"Wearable Performance Devices in Sports Medicine","volume":"8","author":"Li","year":"2016","journal-title":"Sports Health"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"898","DOI":"10.1136\/bjsports-2018-100493","article-title":"Is Running Associated with a Lower Risk of All-Cause, Cardiovascular and Cancer Mortality, and Is the More the Better? A Systematic Review and Meta-Analysis","volume":"54","author":"Pedisic","year":"2020","journal-title":"Br. J. Sports Med."},{"key":"ref_9","unstructured":"Daniels, J. (2013). Daniels\u2019 Running Formula, Human Kinetics. [3rd ed.]."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"3406","DOI":"10.1242\/jeb.125500","article-title":"Effects of Stride Frequency and Foot Position at Landing on Braking Force, Hip Torque, Impact Peak Force and the Metabolic Cost of Running in Humans","volume":"218","author":"Lieberman","year":"2015","journal-title":"J. Exp. Biol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"2177","DOI":"10.1249\/MSS.0b013e3181a984c4","article-title":"Effects of Stride Length and Running Mileage on a Probabilistic Stress Fracture Model","volume":"41","author":"Edwards","year":"2009","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Van Oeveren, B.T., de Ruiter, C.J., Beek, P.J., and van Die\u00ebn, J.H. (2021). The Biomechanics of Running and Running Styles: A Synthesis. Sports Biomech., 1\u201339.","DOI":"10.1080\/14763141.2021.1873411"},{"key":"ref_13","unstructured":"(2022, April 05). Wearable Tech Named Top Fitness Trend for 2022. Available online: https:\/\/www.acsm.org\/news-detail."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1249\/FIT.0000000000000631","article-title":"Worldwide Survey of Fitness Trends for 2021","volume":"25","author":"Thompson","year":"2021","journal-title":"ACSM\u2019s Health Fit. J."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"e102","DOI":"10.2196\/mhealth.9341","article-title":"Recommendations for Assessment of the Reliability, Sensitivity, and Validity of Data Provided by Wearable Sensors Designed for Monitoring Physical Activity","volume":"6","author":"Fuss","year":"2018","journal-title":"JMIR Mhealth Uhealth"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1240","DOI":"10.1136\/bjsports-2016-097295","article-title":"Wearable, Yes, but Able \u2026?: It Is Time for Evidence-Based Marketing Claims!","volume":"51","author":"Sperlich","year":"2017","journal-title":"Br. J. Sports Med."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"6116","DOI":"10.1109\/ACCESS.2018.2791579","article-title":"Pedestrian Dead-Reckoning Indoor Localization Based on OS-ELM","volume":"6","author":"Zhang","year":"2018","journal-title":"IEEE Access"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1186\/s12984-019-0494-z","article-title":"Locomotion and Cadence Detection Using a Single Trunk-Fixed Accelerometer: Validity for Children with Cerebral Palsy in Daily Life-like Conditions","volume":"16","author":"Newman","year":"2019","journal-title":"J. NeuroEngineering Rehabil."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1177\/096228029900800204","article-title":"Measuring Agreement in Method Comparison Studies","volume":"8","author":"Bland","year":"1999","journal-title":"Stat. Methods Med. Res."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Nijs, A., Beek, P.J., and Roerdink, M. (2021). Reliability and Validity of Running Cadence and Stance Time Derived from Instrumented Wireless Earbuds. Sensors, 21.","DOI":"10.3390\/s21237995"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"471","DOI":"10.2519\/jospt.2016.6391","article-title":"Validity and Reliability of a Commercial Fitness Watch for Measuring Running Dynamics","volume":"46","author":"Adams","year":"2016","journal-title":"J. Orthop. Sports Phys. Ther."},{"key":"ref_22","unstructured":"(2022, April 05). Is There an Optimal Way to Run? | SportMedBC. Available online: https:\/\/sportmedbc.com\/article\/there-optimal-way-run."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/13\/4897\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T23:40:07Z","timestamp":1760139607000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/13\/4897"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,29]]},"references-count":22,"journal-issue":{"issue":"13","published-online":{"date-parts":[[2022,7]]}},"alternative-id":["s22134897"],"URL":"https:\/\/doi.org\/10.3390\/s22134897","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6,29]]}}}