{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T01:31:09Z","timestamp":1787880669527,"version":"build-2784847793"},"reference-count":32,"publisher":"MDPI AG","issue":"14","license":[{"start":{"date-parts":[[2022,7,6]],"date-time":"2022-07-06T00:00:00Z","timestamp":1657065600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Compensated shock and hypovolaemia are frequent conditions that remain clinically undetected and can quickly cause deterioration of perioperative and critically ill patients. Automated, accurate and non-invasive detection methods are needed to avoid such critical situations. In this experimental study, we aimed to create a prediction model for stroke volume index (SVI) decrease based on electrical cardiometry (EC) measurements. Transthoracic echo served as reference for SVI assessment (SVI-TTE). In 30 healthy male volunteers, central hypovolaemia was simulated using a lower body negative pressure (LBNP) chamber. A machine-learning algorithm based on variables of EC was designed. During LBNP, SVI-TTE declined consecutively, whereas the vital signs (arterial pressures and heart rate) remained within normal ranges. Compared to heart rate (AUC: 0.83 (95% CI: 0.73\u20130.87)) and systolic arterial pressure (AUC: 0.82 (95% CI: 0.74\u20130.85)), a model integrating EC variables (AUC: 0.91 (0.83\u20130.94)) showed a superior ability to predict a decrease in SVI-TTE \u2265 20% (p = 0.013 compared to heart rate, and p = 0.002 compared to systolic blood pressure). Simulated central hypovolaemia was related to a substantial decline in SVI-TTE but only minor changes in vital signs. A model of EC variables based on machine-learning algorithms showed high predictive power to detect a relevant decrease in SVI and may provide an automated, non-invasive method to indicate hypovolaemia and compensated shock.<\/jats:p>","DOI":"10.3390\/s22145066","type":"journal-article","created":{"date-parts":[[2022,7,6]],"date-time":"2022-07-06T21:15:52Z","timestamp":1657142152000},"page":"5066","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Detection of a Stroke Volume Decrease by Machine-Learning Algorithms Based on Thoracic Bioimpedance in Experimental Hypovolaemia"],"prefix":"10.3390","volume":"22","author":[{"given":"Matthias","family":"Stetzuhn","sequence":"first","affiliation":[{"name":"Department of Anaesthesiology and Operative Intensive Care Medicine (CCM, CVK), Charit\u00e9\u2013Universit\u00e4tsmedizin Berlin, Corporate Member of Freie Universit\u00e4t Berlin, Humboldt-Universit\u00e4t zu Berlin, and Berlin Institute of Health, 13353 Berlin, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1275-5796","authenticated-orcid":false,"given":"Timo","family":"Tigges","sequence":"additional","affiliation":[{"name":"Department of Electronics and Medical Signal Processing, Technical University, 10587 Berlin, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexandru Gabriel","family":"Pielmus","sequence":"additional","affiliation":[{"name":"Department of Electronics and Medical Signal Processing, Technical University, 10587 Berlin, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1062-0495","authenticated-orcid":false,"given":"Claudia","family":"Spies","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology and Operative Intensive Care Medicine (CCM, CVK), Charit\u00e9\u2013Universit\u00e4tsmedizin Berlin, Corporate Member of Freie Universit\u00e4t Berlin, Humboldt-Universit\u00e4t zu Berlin, and Berlin Institute of Health, 13353 Berlin, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charlotte","family":"Middel","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology and Operative Intensive Care Medicine (CCM, CVK), Charit\u00e9\u2013Universit\u00e4tsmedizin Berlin, Corporate Member of Freie Universit\u00e4t Berlin, Humboldt-Universit\u00e4t zu Berlin, and Berlin Institute of Health, 13353 Berlin, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6993-6753","authenticated-orcid":false,"given":"Michael","family":"Klum","sequence":"additional","affiliation":[{"name":"Department of Electronics and Medical Signal Processing, Technical University, 10587 Berlin, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6114-3142","authenticated-orcid":false,"given":"Sebastian","family":"Zaunseder","sequence":"additional","affiliation":[{"name":"Faculty of Information Technology, Fachhochschule Dortmund\u2014University of Applied Sciences and Arts, 44139 Dortmund, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Reinhold","family":"Orglmeister","sequence":"additional","affiliation":[{"name":"Department of Electronics and Medical Signal Processing, Technical University, 10587 Berlin, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0014-8879","authenticated-orcid":false,"given":"Aarne","family":"Feldheiser","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology and Operative Intensive Care Medicine (CCM, CVK), Charit\u00e9\u2013Universit\u00e4tsmedizin Berlin, Corporate Member of Freie Universit\u00e4t Berlin, Humboldt-Universit\u00e4t zu Berlin, and Berlin Institute of Health, 13353 Berlin, Germany"},{"name":"Department of Anaesthesiology, Intensive Care Medicine and Pain Therapy, Evang. Kliniken Essen-Mitte, Huyssens-Stiftung\/Knappschaft, 45136 Essen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,7,6]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Stokes, M.E., Ye, X., Shah, M., Mercaldi, K., Reynolds, M.W., Rupnow, M.F., and Hammond, J. (2011). Impact of Bleeding-Related Complications and\/or Blood Product Transfusions on Hospital Costs in Inpatient Surgical Patients. BMC Health Serv. Res., 11.","DOI":"10.1186\/1472-6963-11-135"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1815","DOI":"10.1016\/S0195-668X(03)00485-8","article-title":"Predictors of Major Bleeding in Acute Coronary Syndromes: The Global Registry of Acute Coronary Events (GRACE)","volume":"24","author":"Moscucci","year":"2003","journal-title":"Eur. Heart J."},{"key":"ref_3","unstructured":"Hall, J.E., and Hall, M.E. (2017). Guyton and Hall Textbook of Medical Physiology, Elsevier. [12th ed.]."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/2110-5820-1-1","article-title":"Hemodynamic Parameters to Guide Fluid Therapy","volume":"1","author":"Marik","year":"2011","journal-title":"Ann. Intensive Care"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1432","DOI":"10.1097\/TA.0b013e31829246c7","article-title":"The Value of Traditional Vital Signs, Shock Index, and Age-Based Markers in Predicting Trauma Mortality","volume":"74","author":"Bruijns","year":"2013","journal-title":"J. Trauma Acute Care Surg."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1016\/S0736-4679(03)00042-8","article-title":"Diagnosis and Monitoring of Hemorrhagic Shock during the Initial Resuscitation of Multiple Trauma Patients: A Review","volume":"24","author":"Wilson","year":"2003","journal-title":"J. Emerg. Med."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1022","DOI":"10.1001\/jama.281.11.1022","article-title":"Is This Patient Hypovolemic?","volume":"281","author":"McGee","year":"1999","journal-title":"JAMA"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1097\/SHK.0000000000000323","article-title":"Individual-Specific, Beat-to-Beat Trending of Significant Human Blood Loss: The Compensatory Reserve","volume":"44","author":"Convertino","year":"2015","journal-title":"Shock"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1007\/s001340050328","article-title":"Comparison of Commonly Used Clinical Indicators of Hypovolaemia with Gastrointestinal Tonometry","volume":"23","author":"Mythen","year":"1997","journal-title":"Intensive Care Med."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1249","DOI":"10.1152\/japplphysiol.01155.2003","article-title":"Lower Body Negative Pressure as a Model to Study Progression to Acute Hemorrhagic Shock in Humans","volume":"96","author":"Cooke","year":"2004","journal-title":"J. Appl. Physiol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1186\/s13054-017-1737-7","article-title":"Transthoracic Echocardiography: An Accurate and Precise Method for Estimating Cardiac Output in the Critically Ill Patient","volume":"21","author":"Mercado","year":"2017","journal-title":"Crit. Care"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"44","DOI":"10.3389\/fmed.2015.00044","article-title":"Hemodynamic Monitoring in the Critically Ill Patient\u2014Current Status and Perspective","volume":"2","author":"Sakka","year":"2015","journal-title":"Front. Med."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1093\/bja\/aew461","article-title":"Accuracy and Precision of Non-Invasive Cardiac Output Monitoring Devices in Perioperative Medicine: A Systematic Review and Meta-Analysis \u2020","volume":"118","author":"Joosten","year":"2017","journal-title":"Br. J. Anaesth."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1007\/s10877-015-9757-9","article-title":"Accuracy and Precision of Minimally-Invasive Cardiac Output Monitoring in Children: A Systematic Review and Meta-Analysis","volume":"30","author":"Suehiro","year":"2016","journal-title":"J. Clin. Monit. Comput."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1007\/s10877-017-9976-3","article-title":"Journal of Clinical Monitoring and Computing 2016 End of Year Summary: Cardiovascular and Hemodynamic Monitoring","volume":"31","author":"Saugel","year":"2017","journal-title":"J. Clin. Monit. Comput."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Tigges, T., Feldheiser, A., Pielmus, A., Klum, M., Wiegank, L., and Orglmeister, R. (2019, January 23\u201327). Evaluation of Pulse Arrival Times during Lower Body Negative Pressure Test for the Non-Invasive Detection of Hypovolemia. Proceedings of the 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Berlin, Germany.","DOI":"10.1109\/EMBC.2019.8856652"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1152\/advan.00009.2006","article-title":"Construction of a Lower Body Negative Pressure Chamber","volume":"31","author":"Esch","year":"2007","journal-title":"Adv. Physiol. Educ."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1139\/facets-2016-0012","article-title":"How to Build a Lower-Body Differential Pressure Chamber Integrated on a Tilt-Table: A Pedagogy Tool to Demonstrate the Cardiovagal Baroreflex","volume":"1","author":"Tymko","year":"2017","journal-title":"FACETS"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1152\/japplphysiol.00640.2013","article-title":"Validation of Lower Body Negative Pressure as an Experimental Model of Hemorrhage","volume":"116","author":"Shade","year":"2014","journal-title":"J. Appl. Physiol."},{"key":"ref_20","unstructured":"(2020). R Core Team R: A Language and Environment for Statistical Computing, R Foundation for Statistical Computing."},{"key":"ref_21","unstructured":"Kuhn, M. (2020). Caret: Classification and Regression Training, Astrophysics Source Code Library."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1023","DOI":"10.1097\/ALN.0b013e3181d47604","article-title":"Statistical Evaluation of a Biomarker","volume":"112","author":"Ray","year":"2010","journal-title":"Anesthesiology"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1097\/ALN.0b013e318225b80a","article-title":"Assessing the Diagnostic Accuracy of Pulse Pressure Variations for the Prediction of Fluid Responsiveness: A \u201cGray Zone\u201d Approach","volume":"115","author":"Cannesson","year":"2011","journal-title":"Anesthesiology"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1002\/1097-0142(1950)3:1<32::AID-CNCR2820030106>3.0.CO;2-3","article-title":"Index for Rating Diagnostic Tests","volume":"3","author":"Youden","year":"1950","journal-title":"Cancer"},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Hastie, T., Tibshirani, R., and Friedman, J. (2009). The Elements of Statistical Learning: Data Mining, Inference, and Prediction, Springer.","DOI":"10.1007\/978-0-387-84858-7"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"807","DOI":"10.1152\/physrev.00006.2018","article-title":"Lower Body Negative Pressure: Physiological Effects, Applications, and Implementation","volume":"99","author":"Goswami","year":"2019","journal-title":"Physiol. Rev."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1016\/j.autneu.2004.02.007","article-title":"Stroke Volume and Sympathetic Responses to Lower-Body Negative Pressure Reveal New Insight into Circulatory Shock in Humans","volume":"111","author":"Convertino","year":"2004","journal-title":"Auton. Neurosci."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1161\/01.RES.34.4.515","article-title":"Human Splanchnic and Forearm Vasoconstrictor Responses to Reductions of Right Atrial and Aortic Pressures","volume":"34","author":"Johnson","year":"1974","journal-title":"Circ. Res."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1093\/bja\/aei224","article-title":"Comparison of Electrical Velocimetry and Transoesophageal Doppler Echocardiography for Measuring Stroke Volume and Cardiac Output","volume":"95","author":"Schmidt","year":"2005","journal-title":"Br. J. Anaesth."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"75","DOI":"10.2152\/jmi.66.75","article-title":"Measurement of Hemodynamics Immediately after Vaginal Delivery in Healthy Pregnant Women by Electrical Cardiometry","volume":"66","author":"Yoshida","year":"2019","journal-title":"J. Med. Investig."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1007\/s10877-019-00330-y","article-title":"Accuracy and Precision of Non-Invasive Cardiac Output Monitoring by Electrical Cardiometry: A Systematic Review and Meta-Analysis","volume":"34","author":"Sanders","year":"2020","journal-title":"J. Clin. Monit. Comput."},{"key":"ref_32","first-page":"S25","article-title":"Use of Advanced Machine-Learning Techniques for Noninvasive Monitoring of Hemorrhage","volume":"71","author":"Convertino","year":"2011","journal-title":"J. Trauma"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/14\/5066\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T23:43:16Z","timestamp":1760139796000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/14\/5066"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,6]]},"references-count":32,"journal-issue":{"issue":"14","published-online":{"date-parts":[[2022,7]]}},"alternative-id":["s22145066"],"URL":"https:\/\/doi.org\/10.3390\/s22145066","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,6]]}}}