{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T22:22:06Z","timestamp":1773872526518,"version":"3.50.1"},"reference-count":36,"publisher":"MDPI AG","issue":"14","license":[{"start":{"date-parts":[[2022,7,13]],"date-time":"2022-07-13T00:00:00Z","timestamp":1657670400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003447","name":"State Scholarships Foundation (IK\u03a5)","doi-asserted-by":"publisher","award":["MIS-5000432"],"award-info":[{"award-number":["MIS-5000432"]}],"id":[{"id":"10.13039\/501100003447","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Automatically delineating the deep and superficial aponeurosis of the skeletal muscles from ultrasound images is important in many aspects of the clinical routine. In particular, finding muscle parameters, such as thickness, fascicle length or pennation angle, is a time-consuming clinical task requiring both human labour and specialised knowledge. In this study, a multi-step solution for automating these tasks is presented. A process to effortlessly extract the aponeurosis for automatically measuring the muscle thickness has been introduced as a first step. This process consists mainly of three parts. In the first part, the Attention UNet has been incorporated to automatically delineate the boundaries of the studied muscles. Afterwards, a specialised post-processing algorithm was utilised to improve (and correct) the segmentation results. Lastly, the calculation of the muscle thickness was performed. The proposed method has achieved similar to a human-level performance. In particular, the overall discrepancy between the automatic and the manual muscle thickness measurements was equal to 0.4 mm, a significant result that demonstrates the feasibility of automating this task. In the second step of the proposed methodology, the fascicle\u2019s length and pennation angle are extracted through an unsupervised pipeline. Initially, filtering is applied to the ultrasound images to further distinguish the tissues from the other muscle structures. Later, the well-known K-Means algorithm is used to isolate them successfully. As the last step, the dominant angle of the segmented muscle tissues is reported and compared with manual measurements. The proposed pipeline is showing very promising results in the evaluated dataset. Specifically, in the calculation of the pennation angle, the overall discrepancy between the automatic and the manual measurements was less than 2.22\u00b0 (degrees), once more comparable with the human-level performance. Finally, regarding the fascicle length measurements, the results were divided based on the muscle properties. In the muscles where a large portion (or all) of the fascicles are located between the upper and lower aponeuroses, the proposed pipeline exhibits superb performance; otherwise, overall accuracy deteriorates due to errors caused by the trigonometric approximations needed for the length calculation.<\/jats:p>","DOI":"10.3390\/s22145230","type":"journal-article","created":{"date-parts":[[2022,7,14]],"date-time":"2022-07-14T00:12:40Z","timestamp":1657757560000},"page":"5230","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":20,"title":["Automatic Extraction of Muscle Parameters with Attention UNet in Ultrasonography"],"prefix":"10.3390","volume":"22","author":[{"given":"Sofoklis","family":"Katakis","sequence":"first","affiliation":[{"name":"Electronics Laboratory, Department of Physics, University of Patras, 26504 Patras, Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nikolaos","family":"Barotsis","sequence":"additional","affiliation":[{"name":"Department of Medical Physics, School of Medicine, University of Patras, 26504 Patras, Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexandros","family":"Kakotaritis","sequence":"additional","affiliation":[{"name":"Electronics Laboratory, Department of Physics, University of Patras, 26504 Patras, Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"George","family":"Economou","sequence":"additional","affiliation":[{"name":"Electronics Laboratory, Department of Physics, University of Patras, 26504 Patras, Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elias","family":"Panagiotopoulos","sequence":"additional","affiliation":[{"name":"Orthopaedic and Rehabilitation Department, Patras University Hospital, 26504 Patras, Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"George","family":"Panayiotakis","sequence":"additional","affiliation":[{"name":"Department of Medical Physics, School of Medicine, University of Patras, 26504 Patras, Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2022,7,13]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1097\/MRR.0000000000000390","article-title":"Reliability of muscle thickness measurements in ultrasonography","volume":"43","author":"Barotsis","year":"2020","journal-title":"Int. J. Rehabil. Res."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1111\/j.1600-0838.2011.01338.x","article-title":"Skeletal Muscle Remodeling in Response to Alpine Skiing Training in Older Individuals","volume":"21","author":"Narici","year":"2011","journal-title":"Scand. J. Med. Sci. Sports"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1007\/s00421-008-0703-0","article-title":"Effect of 5 Weeks Horizontal Bed Rest on Human Muscle Thickness and Architecture of Weight Bearing and Non-Weight Bearing Muscles","volume":"104","author":"Seynnes","year":"2008","journal-title":"Eur. J. Appl. Physiol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1215","DOI":"10.1093\/gerona\/glq118","article-title":"Effects of Testosterone on Skeletal Muscle Architecture in Intermediate-Frail and Frail Elderly Men","volume":"65A","author":"Atkinson","year":"2010","journal-title":"J. Gerontol. Ser. A"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"2165","DOI":"10.1088\/0967-3334\/35\/10\/2165","article-title":"Anterior Thigh Composition Measured Using Ultrasound Imaging to Quantify Relative Thickness of Muscle and Non-Contractile Tissue: A Potential Biomarker for Musculoskeletal Health","volume":"35","author":"Warner","year":"2014","journal-title":"Physiol. Meas."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1002\/mus.21015","article-title":"Muscle Ultrasound in Neuromuscular Disorders","volume":"37","author":"Pillen","year":"2008","journal-title":"Muscle Nerve"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1186\/1880-6805-32-12","article-title":"Validity of Ultrasound Muscle Thickness Measurements for Predicting Leg Skeletal Muscle Mass in Healthy Japanese Middle-Aged and Older Individuals","volume":"32","author":"Takai","year":"2013","journal-title":"J. Physiol. Anthropol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1111\/cpf.12214","article-title":"Ultrasound Assessment of Hamstring Muscle Size Using Posterior Thigh Muscle Thickness","volume":"36","author":"Abe","year":"2016","journal-title":"Clin. Physiol. Funct. Imaging"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1007\/s00421-009-1269-1","article-title":"Development of an Equation to Predict Muscle Volume of Elbow Flexors for Men and Women with a Wide Range of Age","volume":"108","author":"Akagi","year":"2010","journal-title":"Eur. J. Appl. Physiol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"427","DOI":"10.23736\/S1973-9087.20.06222-X","article-title":"The ultrasonographic measurement of muscle thickness in sarcopenia. A prediction study","volume":"56","author":"Barotsis","year":"2020","journal-title":"Eur. J. Phys. Rehabil. Med."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1647","DOI":"10.1002\/1097-4598(200011)23:11<1647::AID-MUS1>3.0.CO;2-M","article-title":"Functional and clinical significance of skeletal muscle architecture","volume":"23","author":"Lieber","year":"2000","journal-title":"Muscle Nerve"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"226","DOI":"10.5432\/ijshs.3.226","article-title":"Use of Three-Dimensional Ultrasonography for the Analysis of the Fascicle Length of Human Gastrocnemius Muscle During Contractions","volume":"3","author":"Kurihara","year":"2005","journal-title":"Int. J. Sport Health Sci."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"761","DOI":"10.1152\/japplphysiol.01430.2011","article-title":"Reliability and Validity of Ultrasound Measurements of Muscle Fascicle Length and Pennation in Humans: A Systematic Review","volume":"114","author":"Kwah","year":"2013","journal-title":"J. Appl. Physiol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1111\/j.1469-7793.1998.603be.x","article-title":"In Vivo Measurements of the Triceps Surae Complex Architecture in Man: Implications for Muscle Function","volume":"512","author":"Maganaris","year":"1998","journal-title":"J. Physiol."},{"key":"ref_15","first-page":"359","article-title":"Muscle and Tendon: Properties, Models, Scaling, and Application to Biomechanics and Motor Control","volume":"17","author":"Zajac","year":"1989","journal-title":"Crit. Rev. Biomed. Eng."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"672","DOI":"10.1016\/j.ultrasmedbio.2018.11.012","article-title":"Transverse Muscle Ultrasound Analysis (TRAMA): Robust and Accurate Segmentation of Muscle Cross-Sectional Area","volume":"45","author":"Salvi","year":"2019","journal-title":"Ultrasound Med. Biol."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Marzola, F., van Alfen, N., Salvi, M., Santi, B.D., Doorduin, J., and Meiburger, K.M. (2020, January 20\u201324). Automatic Segmentation of Ultrasound Images of Gastrocnemius Medialis with Different Echogenicity Levels Using Convolutional Neural Networks. Proceedings of the 2020 42nd Annual International Conference of the IEEE Engineering in Medicine Biology Society (EMBC), Montreal, QC, Canada.","DOI":"10.1109\/EMBC44109.2020.9176343"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1016\/j.ultrasmedbio.2016.08.032","article-title":"Fully Automated Muscle Ultrasound Analysis (MUSA): Robust and Accurate Muscle Thickness Measurement","volume":"43","author":"Caresio","year":"2017","journal-title":"Ultrasound Med. Biol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"105583","DOI":"10.1016\/j.cmpb.2020.105583","article-title":"Using Deep Learning to Generate Synthetic B-Mode Musculoskeletal Ultrasound Images","volume":"196","author":"Cronin","year":"2020","journal-title":"Comput. Methods Programs Biomed."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2068","DOI":"10.1016\/j.jbiomech.2009.06.003","article-title":"Automated Tracking of Muscle Fascicle Orientation in B-Mode Ultrasound Images","volume":"42","author":"Rana","year":"2009","journal-title":"J. Biomech."},{"key":"ref_21","unstructured":"Oktay, O., Schlemper, J., Folgoc, L.L., Lee, M., Heinrich, M., Misawa, K., Mori, K., McDonagh, S., Hammerla, N.Y., and Kainz, B. (2018). Attention U-Net: Learning Where to Look for the Pancreas. arXiv."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1562","DOI":"10.1016\/j.ultrasmedbio.2019.02.011","article-title":"Muscle Type and Gender Recognition Utilising High-Level Textural Representation in Musculoskeletal Ultrasonography","volume":"45","author":"Katakis","year":"2019","journal-title":"Ultrasound Med. Biol."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Katakis, S., Barotsis, N., Kastaniotis, D., Theoharatos, C., Tsourounis, D., Fotopoulos, S., and Panagiotopoulos, E. (2018, January 10\u201312). Muscle Type Classification on Ultrasound Imaging Using Deep Convolutional Neural Networks. Proceedings of the 2018 IEEE 13th Image, Video, and Multidimensional Signal Processing Workshop (IVMSP), Aristi Village, Greece.","DOI":"10.1109\/IVMSPW.2018.8448648"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Ronneberger, O., Fischer, P., and Brox, T. (2015). U-Net: Convolutional Networks for Biomedical Image Segmentation. arXiv.","DOI":"10.1007\/978-3-319-24574-4_28"},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Lin, M., Bao, G., Sang, X., and Wu, Y. (2022). Recent Advanced Deep Learning Architectures for Retinal Fluid Segmentation on Optical Coherence Tomography Images. Sensors, 22.","DOI":"10.3390\/s22083055"},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Lee, H.M., Kim, Y.J., and Kim, K.G. (2022). Segmentation Performance Comparison Considering Regional Characteristics in Chest X-ray Using Deep Learning. Sensors, 22.","DOI":"10.3390\/s22093143"},{"key":"ref_27","unstructured":"Kingma, D.P., and Ba, J. (2014). Adam: A Method for Stochastic Optimisation. arXiv."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"108519","DOI":"10.1016\/j.apacoust.2021.108519","article-title":"Active echo signals and image optimization techniques via software filter correction of ultrasound system","volume":"188","author":"Jung","year":"2022","journal-title":"Appl. Acoust."},{"key":"ref_29","unstructured":"Heckbert, P. (1994). Contrast Limited Adaptive Histogram Equalization. Graphics Gems IV, Academic Press."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1002\/cyto.a.20022","article-title":"Design and validation of a tool for neurite tracing and analysis in fluorescence microscopy images","volume":"58","author":"Meijering","year":"2004","journal-title":"M Unser Cytom. Part A"},{"key":"ref_31","first-page":"129","article-title":"\u201cLeast squares quantisation in PCM\u201d Information Theory","volume":"28","author":"Lloyd","year":"1982","journal-title":"IEEE Trans."},{"key":"ref_32","first-page":"213","article-title":"Intraclass correlation coefficient","volume":"Volume 4","author":"Kotz","year":"2005","journal-title":"Encyclopedia of Statistical Sciences"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"307","DOI":"10.2307\/2987937","article-title":"Measurement in medicine: The analysis of method comparison studies","volume":"32","author":"Altman","year":"1983","journal-title":"Statistician"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1016\/j.pmrj.2015.09.014","article-title":"Ultrasound-based detection of low muscle mass for diagnosis of sarcopenia in older adults","volume":"8","author":"Minetto","year":"2016","journal-title":"PM&R"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1007\/s11357-013-9539-6","article-title":"Prevalence of site-specific thigh sarcopenia in Japanese men and women","volume":"36","author":"Abe","year":"2014","journal-title":"Age (Dordr)"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"106936","DOI":"10.1016\/j.cmpb.2022.106936","article-title":"Automated ultrasound measurements of lateral abdominal muscles under controlled breathing phases","volume":"221","author":"Linek","year":"2022","journal-title":"Comput. Methods Programs Biomed."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/14\/5230\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T23:49:25Z","timestamp":1760140165000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/14\/5230"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,13]]},"references-count":36,"journal-issue":{"issue":"14","published-online":{"date-parts":[[2022,7]]}},"alternative-id":["s22145230"],"URL":"https:\/\/doi.org\/10.3390\/s22145230","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,13]]}}}