{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T00:00:29Z","timestamp":1780444829457,"version":"3.54.1"},"reference-count":39,"publisher":"MDPI AG","issue":"15","license":[{"start":{"date-parts":[[2022,8,2]],"date-time":"2022-08-02T00:00:00Z","timestamp":1659398400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"MCIU","award":["PID2021-126734OB-C21"],"award-info":[{"award-number":["PID2021-126734OB-C21"]}]},{"name":"MCIU","award":["T39 20R"],"award-info":[{"award-number":["T39 20R"]}]},{"name":"Aragon Government","award":["PID2021-126734OB-C21"],"award-info":[{"award-number":["PID2021-126734OB-C21"]}]},{"name":"Aragon Government","award":["T39 20R"],"award-info":[{"award-number":["T39 20R"]}]},{"name":"CIBER","award":["PID2021-126734OB-C21"],"award-info":[{"award-number":["PID2021-126734OB-C21"]}]},{"name":"CIBER","award":["T39 20R"],"award-info":[{"award-number":["T39 20R"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Heart rate variability (HRV) has been studied for decades in clinical environments. Currently, the exponential growth of wearable devices in health monitoring is leading to new challenges that need to be solved. These devices have relatively poor signal quality and are affected by numerous motion artifacts, with data loss being the main stumbling block for their use in HRV analysis. In the present paper, it is shown how data loss affects HRV metrics in the time domain and frequency domain and Poincar\u00e9 plots. A gap-filling method is proposed and compared to other existing approaches to alleviate these effects, both with simulated (16 subjects) and real (20 subjects) missing data. Two different data loss scenarios have been simulated: (i) scattered missing beats, related to a low signal to noise ratio; and (ii) bursts of missing beats, with the most common due to motion artifacts. In addition, a real database of photoplethysmography-derived pulse detection series provided by Apple Watch during a protocol including relax and stress stages is analyzed. The best correction method and maximum acceptable missing beats are given. Results suggest that correction without gap filling is the best option for the standard deviation of the normal-to-normal intervals (SDNN), root mean square of successive differences (RMSSD) and Poincar\u00e9 plot metrics in datasets with bursts of missing beats predominance (p&lt;0.05), whereas they benefit from gap-filling approaches in the case of scattered missing beats (p&lt;0.05). Gap-filling approaches are also the best for frequency-domain metrics (p&lt;0.05). The findings of this work are useful for the design of robust HRV applications depending on missing data tolerance and the desired HRV metrics.<\/jats:p>","DOI":"10.3390\/s22155774","type":"journal-article","created":{"date-parts":[[2022,8,3]],"date-time":"2022-08-03T00:15:26Z","timestamp":1659485726000},"page":"5774","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":27,"title":["Effects of Missing Data on Heart Rate Variability Metrics"],"prefix":"10.3390","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6606-2034","authenticated-orcid":false,"given":"Diego","family":"Cajal","sequence":"first","affiliation":[{"name":"Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Arag\u00f3n Institute of Engineering Research (I3A), IIS Arag\u00f3n, University of Zaragoza, 50018 Zaragoza, Spain"},{"name":"Centro de Investigaci\u00f3n Biom\u00e9dica en Red en Bioingenier\u00eda, Biomateriales y Nanomedicina (CIBER-BBN), 28029 Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1462-4880","authenticated-orcid":false,"given":"David","family":"Hernando","sequence":"additional","affiliation":[{"name":"Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Arag\u00f3n Institute of Engineering Research (I3A), IIS Arag\u00f3n, University of Zaragoza, 50018 Zaragoza, Spain"},{"name":"Centro de Investigaci\u00f3n Biom\u00e9dica en Red en Bioingenier\u00eda, Biomateriales y Nanomedicina (CIBER-BBN), 28029 Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8742-0072","authenticated-orcid":false,"given":"Jes\u00fas","family":"L\u00e1zaro","sequence":"additional","affiliation":[{"name":"Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Arag\u00f3n Institute of Engineering Research (I3A), IIS Arag\u00f3n, University of Zaragoza, 50018 Zaragoza, Spain"},{"name":"Centro de Investigaci\u00f3n Biom\u00e9dica en Red en Bioingenier\u00eda, Biomateriales y Nanomedicina (CIBER-BBN), 28029 Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3434-9254","authenticated-orcid":false,"given":"Pablo","family":"Laguna","sequence":"additional","affiliation":[{"name":"Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Arag\u00f3n Institute of Engineering Research (I3A), IIS Arag\u00f3n, University of Zaragoza, 50018 Zaragoza, Spain"},{"name":"Centro de Investigaci\u00f3n Biom\u00e9dica en Red en Bioingenier\u00eda, Biomateriales y Nanomedicina (CIBER-BBN), 28029 Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7285-0715","authenticated-orcid":false,"given":"Eduardo","family":"Gil","sequence":"additional","affiliation":[{"name":"Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Arag\u00f3n Institute of Engineering Research (I3A), IIS Arag\u00f3n, University of Zaragoza, 50018 Zaragoza, Spain"},{"name":"Centro de Investigaci\u00f3n Biom\u00e9dica en Red en Bioingenier\u00eda, Biomateriales y Nanomedicina (CIBER-BBN), 28029 Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1272-0550","authenticated-orcid":false,"given":"Raquel","family":"Bail\u00f3n","sequence":"additional","affiliation":[{"name":"Biomedical Signal Interpretation and Computational Simulation (BSICoS) Group, Arag\u00f3n Institute of Engineering Research (I3A), IIS Arag\u00f3n, University of Zaragoza, 50018 Zaragoza, Spain"},{"name":"Centro de Investigaci\u00f3n Biom\u00e9dica en Red en Bioingenier\u00eda, Biomateriales y Nanomedicina (CIBER-BBN), 28029 Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,8,2]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1161\/01.CIR.93.5.1043","article-title":"Heart rate variability: Standards of measurement, physiological interpretation, and clinical use","volume":"93","author":"Camm","year":"1996","journal-title":"Circulation"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"2073","DOI":"10.1161\/01.CIR.85.6.2073","article-title":"Heart rate variability during the acute phase of myocardial infarction","volume":"85","author":"Casolo","year":"1992","journal-title":"Circulation"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1016\/0165-1838(88)90078-1","article-title":"Spectral analysis of heart rate variability in the assessment of autonomic diabetic neuropathy","volume":"23","author":"Pagani","year":"1988","journal-title":"J. Auton. Nerv. Syst."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1097\/00004872-198809000-00004","article-title":"Sympathetic predominance in essential hypertension: A study employing spectral analysis of heart rate variability","volume":"6","author":"Guzzetti","year":"1988","journal-title":"J. Hypertens."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1161\/01.CIR.84.2.482","article-title":"Cardiovascular neural regulation explored in the frequency domain","volume":"84","author":"Malliani","year":"1991","journal-title":"Circulation"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1161\/01.CIR.79.1.76","article-title":"Power spectrum analysis of heart rate variability in human cardiac transplant recipients","volume":"79","author":"Sands","year":"1989","journal-title":"Circulation"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/0165-0327(94)90091-4","article-title":"Are affective disorders associated with alterations of heart rate variability?","volume":"32","author":"Rechlin","year":"1994","journal-title":"J. Affect. Disord."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1271","DOI":"10.1088\/0967-3334\/31\/9\/015","article-title":"Photoplethysmography pulse rate variability as a surrogate measurement of heart rate variability during non-stationary conditions","volume":"31","author":"Gil","year":"2010","journal-title":"Physiol. Meas."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.ijcard.2012.03.119","article-title":"How accurate is pulse rate variability as an estimate of heart rate variability?: A review on studies comparing photoplethysmographic technology with an electrocardiogram","volume":"166","author":"Vagedes","year":"2013","journal-title":"Int. J. Cardiol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1016\/j.ijcard.2007.06.047","article-title":"Alterations of an average heart rate change heart rate variability due to mathematical reasons","volume":"128","author":"Sacha","year":"2008","journal-title":"Int. J. Cardiol."},{"key":"ref_11","first-page":"347","article-title":"Interplay between heart rate and its variability: A prognostic game","volume":"5","author":"Sacha","year":"2014","journal-title":"Front. Psychol."},{"key":"ref_12","first-page":"55","article-title":"An introduction to heart rate variability: Methodological considerations and clinical applications","volume":"6","author":"Billman","year":"2015","journal-title":"Front. Psychol."},{"key":"ref_13","first-page":"73","article-title":"Monitoring training status with HR measures: Do all roads lead to Rome?","volume":"5","author":"Buchheit","year":"2014","journal-title":"Front. Psychol."},{"key":"ref_14","first-page":"74","article-title":"Nonlinear digital signal processing in mental health: Characterization of major depression using instantaneous entropy measures of heartbeat dynamics","volume":"6","author":"Valenza","year":"2015","journal-title":"Front. Psychol."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Weippert, M., Behrens, K., Rieger, A., Stoll, R., and Kreuzfeld, S. (2013). Heart rate variability and blood pressure during dynamic and static exercise at similar heart rate levels. PLoS ONE, 8.","DOI":"10.1371\/journal.pone.0083690"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1203\/PDR.0b013e318123fbcc","article-title":"Heart rate variability: Impact of differences in outlier identification and management strategies on common measures in three clinical populations","volume":"62","author":"Kemper","year":"2007","journal-title":"Pediatr. Res."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1109\/TBME.2003.808831","article-title":"Analysis of heart rate variability in the presence of ectopic beats using the heart timing signal","volume":"50","author":"Mateo","year":"2003","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_18","unstructured":"McNames, J., Thong, T., and Aboy, M. (2004, January 1\u20135). Impulse rejection filter for artifact removal in spectral analysis of biomedical signals. Proceedings of the 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, San Francisco, CA, USA."},{"key":"ref_19","unstructured":"Lee, M.Y., and Yu, S.N. (September, January 31). Improving discriminality in heart rate variability analysis using simple artifact and trend removal preprocessors. Proceedings of the 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology, Buenos Aires, Argentina."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Begum, S., Islam, M.S., Ahmed, M.U., and Funk, P. (2011, January 14\u201317). K-NN based interpolation to handle artifacts for heart rate variability analysis. Proceedings of the 2011 IEEE International Symposium on Signal Processing and Information Technology (ISSPIT), Bilbao, Spain.","DOI":"10.1109\/ISSPIT.2011.6151593"},{"key":"ref_21","first-page":"1944","article-title":"A pattern-based windowed impulse rejection filter for nonpathological HRV artifacts correction","volume":"64","author":"Eid","year":"2014","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"726","DOI":"10.1519\/JSC.0000000000001800","article-title":"Heart rate variability during exercise: A comparison of artefact correction methods","volume":"32","author":"Giles","year":"2018","journal-title":"J. Strength Cond. Res."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1007\/s10916-017-0796-2","article-title":"Effect of missing inter-beat interval data on heart rate variability analysis using wrist-worn wearables","volume":"41","author":"Baek","year":"2017","journal-title":"J. Med. Syst."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Morelli, D., Rossi, A., Cairo, M., and Clifton, D.A. (2019). Analysis of the impact of interpolation methods of missing RR-intervals caused by motion artifacts on HRV features estimations. Sensors, 19.","DOI":"10.3390\/s19143163"},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Benchekroun, M., Chevallier, B., Istrate, D., Zalc, V., and Lenne, D. (2022). Preprocessing Methods for Ambulatory HRV Analysis Based on HRV Distribution, Variability and Characteristics (DVC). Sensors, 22.","DOI":"10.3390\/s22051984"},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Kr\u00f3lak, A., Wiktorski, T., Bj\u00f8rkavoll-Bergseth, M.F., and \u00d8rn, S. (2020). Artifact correction in short-term hrv during strenuous physical exercise. Sensors, 20.","DOI":"10.3390\/s20216372"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"12432","DOI":"10.1109\/JSEN.2019.2939391","article-title":"Motion artifact removal in ambulatory ECG signal for heart rate variability analysis","volume":"19","author":"Berwal","year":"2019","journal-title":"IEEE Sens. J."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"2238","DOI":"10.1109\/JBHI.2019.2962627","article-title":"Robust interbeat interval and heart rate variability estimation method from various morphological features using wearable sensors","volume":"24","author":"Aygun","year":"2019","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"570","DOI":"10.1109\/TBME.2003.821031","article-title":"A wavelet-based ECG delineator: Evaluation on standard databases","volume":"51","author":"Almeida","year":"2004","journal-title":"IEEE. Trans. Biomed. Eng."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Hernando, D., Roca, S., Sancho, J., Alesanco, \u00c1., and Bail\u00f3n, R. (2018). Validation of the apple watch for heart rate variability measurements during relax and mental stress in healthy subjects. Sensors, 18.","DOI":"10.3390\/s18082619"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1080\/00140137308924484","article-title":"An analysis of heart rate variability","volume":"16","author":"Luczak","year":"1973","journal-title":"Ergonomics"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1007\/BF02441043","article-title":"Measurement of heart-rate variability: Part 1\u2014Comparative study of heart-rate variability analysis methods","volume":"15","author":"Rompelman","year":"1977","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1039","DOI":"10.1088\/0967-3334\/30\/10\/005","article-title":"The effect of missing RR-interval data on heart rate variability analysis in the frequency domain","volume":"30","author":"Kim","year":"2009","journal-title":"Physiol. Meas."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"1016","DOI":"10.1109\/JBHI.2016.2553578","article-title":"Inclusion of Respiratory Frequency Information in Heart Rate Variability Analysis for Stress Assessment","volume":"20","author":"Hernando","year":"2016","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1109\/TBME.1968.4502576","article-title":"Spectral analysis of pulse frequency modulation in the nervous systems","volume":"BME-15","author":"Bayly","year":"1968","journal-title":"IEEE. Trans. Biomed. Eng."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"985","DOI":"10.1109\/10.855925","article-title":"Improved heart rate variability signal analysis from the beat occurrence times according to the IPFM model","volume":"47","author":"Mateo","year":"2000","journal-title":"IEEE. Trans. Biomed. Eng."},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Koichubekov, B., Riklefs, V., Sorokina, M., Korshukov, I., Turgunova, L., Laryushina, Y., and Kultenova, M. (2017). Informative nature and nonlinearity of lagged poincar\u00e9 plots indices in analysis of heart rate variability. Entropy, 19.","DOI":"10.3390\/e19100523"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"741","DOI":"10.1109\/JBHI.2017.2694999","article-title":"Reliability of lagged poincar\u00e9 plot parameters in ultrashort heart rate variability series: Application on affective sounds","volume":"22","author":"Nardelli","year":"2017","journal-title":"IEEE. J. Biomed. Health Inform."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1109\/10.678605","article-title":"Power spectral density of unevenly sampled data by least-square analysis: Performance and application to heart rate signals","volume":"45","author":"Laguna","year":"1998","journal-title":"IEEE. Trans. Biomed. Eng."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/15\/5774\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T00:01:16Z","timestamp":1760140876000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/15\/5774"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8,2]]},"references-count":39,"journal-issue":{"issue":"15","published-online":{"date-parts":[[2022,8]]}},"alternative-id":["s22155774"],"URL":"https:\/\/doi.org\/10.3390\/s22155774","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,8,2]]}}}