{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T16:39:46Z","timestamp":1768408786585,"version":"3.49.0"},"reference-count":54,"publisher":"MDPI AG","issue":"17","license":[{"start":{"date-parts":[[2022,9,5]],"date-time":"2022-09-05T00:00:00Z","timestamp":1662336000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Quantitatively assessing personal health status is gaining increasing attention due to the improvement of diagnostic technology and the increasing occurrence of chronic pathologies. Monitoring physiological parameters allows for retrieving a general overview of the personal health status. Respiratory activity can provide relevant information, especially when pathologies affect the muscles and organs involved in breathing. Among many technologies, wearables may represent a valid solution for continuous and remote monitoring of respiratory activity, thus reducing healthcare costs. The most popular wearables used in this arena are based on detecting the breathing-induced movement of the chest wall. Therefore, their use in patients with impaired chest wall motion and abnormal respiratory kinematics can be challenging, but literature is still in its infancy. This study investigates the performance of a custom wearable device for respiratory monitoring in post-stroke patients. We tested the device on six hemiplegic patients under different respiratory regimes. The estimated respiratory parameters (i.e., respiratory frequency and the timing of the respiratory phase) demonstrated good agreement with the ones provided by a gold standard device. The promising results of this pilot study encourage the exploitation of wearables on these patients that may strongly impact the treatment of chronic diseases, such as hemiplegia.<\/jats:p>","DOI":"10.3390\/s22176708","type":"journal-article","created":{"date-parts":[[2022,9,8]],"date-time":"2022-09-08T04:18:32Z","timestamp":1662610712000},"page":"6708","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Investigating Stroke Effects on Respiratory Parameters Using a Wearable Device: A Pilot Study on Hemiplegic Patients"],"prefix":"10.3390","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9841-7861","authenticated-orcid":false,"given":"Joshua","family":"Di Tocco","sequence":"first","affiliation":[{"name":"Unit of Measurements and Biomedical Instrumentation, Universit\u00e0 Campus Bio-Medico di Roma, 00128 Rome, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1507-231X","authenticated-orcid":false,"given":"Daniela","family":"Lo Presti","sequence":"additional","affiliation":[{"name":"Unit of Measurements and Biomedical Instrumentation, Universit\u00e0 Campus Bio-Medico di Roma, 00128 Rome, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4849-6212","authenticated-orcid":false,"given":"Martina","family":"Zaltieri","sequence":"additional","affiliation":[{"name":"Unit of Measurements and Biomedical Instrumentation, Universit\u00e0 Campus Bio-Medico di Roma, 00128 Rome, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3396-4100","authenticated-orcid":false,"given":"Marco","family":"Bravi","sequence":"additional","affiliation":[{"name":"Unit of Physical and Rehabilitative Medicine, Universit\u00e0 Campus Bio-Medico di Roma, 00128 Rome, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4781-264X","authenticated-orcid":false,"given":"Michelangelo","family":"Morrone","sequence":"additional","affiliation":[{"name":"Unit of Physical and Rehabilitative Medicine, Universit\u00e0 Campus Bio-Medico di Roma, 00128 Rome, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2347-7544","authenticated-orcid":false,"given":"Silvia","family":"Sterzi","sequence":"additional","affiliation":[{"name":"Unit of Physical and Rehabilitative Medicine, Universit\u00e0 Campus Bio-Medico di Roma, 00128 Rome, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9696-1265","authenticated-orcid":false,"given":"Emiliano","family":"Schena","sequence":"additional","affiliation":[{"name":"Unit of Measurements and Biomedical Instrumentation, Universit\u00e0 Campus Bio-Medico di Roma, 00128 Rome, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3090-5623","authenticated-orcid":false,"given":"Carlo","family":"Massaroni","sequence":"additional","affiliation":[{"name":"Unit of Measurements and Biomedical Instrumentation, Universit\u00e0 Campus Bio-Medico di Roma, 00128 Rome, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2022,9,5]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Tulchinsky, T.H., and Varavikova, E.A. (2014). Measuring, Monitoring, and Evaluating the Health of a Population. New Public Health, 91\u2013147.","DOI":"10.1016\/B978-0-12-415766-8.00003-3"},{"key":"ref_2","unstructured":"(2022, August 01). Surveillance and Monitoring of Health-Related Indicators. Available online: http:\/\/www.emro.who.int\/about-who\/public-health-functions\/surveillance-and-monitoring-of-health-related-indicators.html."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.resuscitation.2020.01.004","article-title":"Evaluation of a new respiratory monitoring tool \u201cEarly Warning ScoreO2\u201d for patients admitted at the emergency department with dyspnea","volume":"148","author":"Viglino","year":"2020","journal-title":"Resuscitation"},{"key":"ref_4","first-page":"101475","article-title":"Early identification and treatment of COPD exacerbation using remote respiratory monitoring","volume":"34","author":"Polsky","year":"2021","journal-title":"Respir. Med. Case Rep."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1111\/j.1365-2044.1993.tb06949.x","article-title":"Ventilatory effects of pneumoperitoneum monitored with continuous spirometry","volume":"48","author":"Bardoczky","year":"1993","journal-title":"Anaesthesia"},{"key":"ref_6","first-page":"796","article-title":"Workplace spirometry monitoring for respiratory disease prevention: A methods review [State of the art]","volume":"14","author":"Hnizdo","year":"2010","journal-title":"Int. J. Tuberc. Lung Dis."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1016\/j.arbr.2013.07.007","article-title":"Spirometry","volume":"49","author":"Calle","year":"2013","journal-title":"Arch. Bronconeumol. (Engl. Ed.)"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"171","DOI":"10.4028\/www.scientific.net\/KEM.698.171","article-title":"Non-contact vital sensing systems using a motion capture device: Medical and healthcare applications","volume":"Volume 698","author":"Yuminaka","year":"2016","journal-title":"Key Engineering Materials"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"21497","DOI":"10.1038\/s41598-021-01033-8","article-title":"Measurement of chest wall motion using a motion capture system with the one-pitch phase analysis method","volume":"11","author":"Tamiya","year":"2021","journal-title":"Sci. Rep."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1546","DOI":"10.1164\/ajrccm.161.5.9903024","article-title":"Optoelectronic plethysmography in intensive care patients","volume":"161","author":"Aliverti","year":"2000","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1590\/S1413-35552012005000061","article-title":"Optoelectronic plethysmography: A review of the literature","volume":"16","author":"Parreira","year":"2012","journal-title":"Braz. J. Phys. Ther."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1203\/PDR.0b013e3181c0b184","article-title":"Measurement of total and compartmental lung volume changes in newborns by optoelectronic plethysmography","volume":"67","author":"Dellaca","year":"2010","journal-title":"Pediatr. Res."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1125","DOI":"10.1007\/s11276-018-1694-3","article-title":"Technological aspects of WBANs for health monitoring: A comprehensive review","volume":"25","author":"Punj","year":"2019","journal-title":"Wirel. Netw."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1016\/j.cmpb.2018.04.026","article-title":"Mobile and wearable technologies in healthcare for the ageing population","volume":"161","author":"Malwade","year":"2018","journal-title":"Comput. Methods Programs Biomed."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"da Costa, T.D., Vara, M., Cristino, C.S., Zanella, T.Z., Neto, G.N.N., and Nohama, P. (2019). Breathing monitoring and pattern recognition with wearable sensors. Wearable Devices-the Big Wave of Innovation, IntechOpen.","DOI":"10.5772\/intechopen.85460"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Massaroni, C., Nicol\u00f2, A., Lo Presti, D., Sacchetti, M., Silvestri, S., and Schena, E. (2019). Contact-based methods for measuring respiratory rate. Sensors, 19.","DOI":"10.3390\/s19040908"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"6535","DOI":"10.3390\/s140406535","article-title":"Low-power wearable respiratory sound sensing","volume":"14","author":"Oletic","year":"2014","journal-title":"Sensors"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"102027","DOI":"10.1016\/j.isci.2020.102027","article-title":"Wearable triboelectric sensors for biomedical monitoring and human-machine interface","volume":"24","author":"Pu","year":"2021","journal-title":"Iscience"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"7391","DOI":"10.1109\/JSEN.2019.2916320","article-title":"Wearable system based on flexible FBG for respiratory and cardiac monitoring","volume":"19","author":"Presti","year":"2019","journal-title":"IEEE Sens. J."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"De jonckheere, J., Narbonneau, F., D\u2019angelo, L., Witt, J., Paquet, B., Kinet, D., Kreber, K., and Logier, R. (2010, January 1\u20133). FBG-based smart textiles for continuous monitoring of respiratory movements for healthcare applications. Proceedings of the 12th IEEE International Conference on e-Health Networking, Applications and Services, Lyon, France.","DOI":"10.1109\/HEALTH.2010.5556557"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1166\/sl.2015.3407","article-title":"A simultaneous and validated wearable FBG heartbeat and respiration rate monitoring system","volume":"13","author":"Elsarnagawy","year":"2015","journal-title":"Sens. Lett."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"805","DOI":"10.1088\/0957-0233\/12\/7\/309","article-title":"A fibre optic Bragg grating strain sensor for monitoring ventilatory movements","volume":"12","author":"Wehrle","year":"2001","journal-title":"Meas. Sci. Technol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"13167","DOI":"10.3390\/s121013167","article-title":"Development of a respiratory inductive plethysmography module supporting multiple sensors for wearable systems","volume":"12","author":"Zhang","year":"2012","journal-title":"Sensors"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1159\/000212117","article-title":"Respiratory monitoring by inductive plethysmography in unrestrained subjects using position sensor-adjusted calibration","volume":"79","author":"Fritsch","year":"2010","journal-title":"Respiration"},{"key":"ref_25","unstructured":"Wu, D., Wang, L., Zhang, Y.T., Huang, B.Y., Wang, B., Lin, S.J., and Xu, X.W. (2009, January 3\u20136). A wearable respiration monitoring system based on digital respiratory inductive plethysmography. Proceedings of the 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Minneapolis, MN, USA."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1109\/JSEN.2006.874488","article-title":"Inductive fiber-meshed strain and displacement transducers for respiratory measuring systems and motion capturing systems","volume":"6","author":"Wijesiriwardana","year":"2006","journal-title":"IEEE Sens. J."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1109\/JSEN.2008.2010356","article-title":"Textile-based capacitive sensors for respiration monitoring","volume":"9","author":"Merritt","year":"2008","journal-title":"IEEE Sens. J."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1039","DOI":"10.3390\/s140101039","article-title":"The MAIN shirt: A textile-integrated magnetic induction sensor array","volume":"14","author":"Teichmann","year":"2014","journal-title":"Sensors"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"04CL05","DOI":"10.7567\/JJAP.52.04CL05","article-title":"A wearable capacitive sensor for monitoring human respiratory rate","volume":"52","author":"Kundu","year":"2013","journal-title":"Jpn. J. Appl. Phys."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"3245","DOI":"10.1109\/JSEN.2014.2327991","article-title":"Simplified structural textile respiration sensor based on capacitive pressure sensing method","volume":"14","author":"Min","year":"2014","journal-title":"IEEE Sens. J."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"7718","DOI":"10.1109\/JSEN.2019.2917617","article-title":"Smart textile based on piezoresistive sensing elements for respiratory monitoring","volume":"19","author":"Massaroni","year":"2019","journal-title":"IEEE Sens. J."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"130869","DOI":"10.1016\/j.cej.2021.130869","article-title":"A highly sensitive stretchable strain sensor based on multi-functionalized fabric for respiration monitoring and identification","volume":"426","author":"Liu","year":"2021","journal-title":"Chem. Eng. J."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1016\/j.sna.2006.02.012","article-title":"A novel wearable sensor device with conductive fabric and PVDF film for monitoring cardiorespiratory signals","volume":"128","author":"Choi","year":"2006","journal-title":"Sens. Actuators A Phys."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"14087","DOI":"10.1021\/acsami.7b19699","article-title":"Interface-controlled conductive fibers for wearable strain sensors and stretchable conducting wires","volume":"10","author":"Cao","year":"2018","journal-title":"ACS Appl. Mater. Interfaces"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"2173","DOI":"10.1109\/JSEN.2019.2949608","article-title":"Respiratory monitoring during physical activities with a multi-sensor smart garment and related algorithms","volume":"20","author":"Massaroni","year":"2019","journal-title":"IEEE Sens. J."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"e201700263","DOI":"10.1002\/jbio.201700263","article-title":"Smart textile for respiratory monitoring and thoraco-abdominal motion pattern evaluation","volume":"11","author":"Massaroni","year":"2018","journal-title":"J. Biophotonics"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"78","DOI":"10.3109\/03790799009166256","article-title":"Respiratory function in chronic hemiplegia","volume":"12","author":"Annoni","year":"1990","journal-title":"Int. Disabil. Stud."},{"key":"ref_38","unstructured":"Davies, P.M. (1990). Right in the Middle: Selective Trunk Activity in the Treatment of Adult Hemiplegia, Springer Science & Business Media."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1259\/bjr\/71968119","article-title":"An evaluation of diaphragmatic movements in hemiplegic patients","volume":"85","author":"Voyvoda","year":"2012","journal-title":"Br. J. Radiol."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1164\/rccm.200207-745OC","article-title":"Chest wall kinematics in patients with hemiplegia","volume":"168","author":"Lanini","year":"2003","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1114\/1.1332084","article-title":"Compartmental analysis of breathing in the supine and prone positions by optoelectronic plethysmography","volume":"29","author":"Aliverti","year":"2001","journal-title":"Ann. Biomed. Eng."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"1412","DOI":"10.1016\/j.rmed.2007.01.021","article-title":"Patterns of chest wall kinematics during volitional pursed-lip breathing in COPD at rest","volume":"101","author":"Bianchi","year":"2007","journal-title":"Respir. Med."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1016\/j.jbiomech.2018.05.036","article-title":"Comparison of marker models for the analysis of the volume variation and thoracoabdominal motion pattern in untrained and trained participants","volume":"76","author":"Massaroni","year":"2018","journal-title":"J. Biomech."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"1224","DOI":"10.1152\/jappl.1994.77.3.1224","article-title":"Three-dimensional optical analysis of chest wall motion","volume":"77","author":"Ferrigno","year":"1994","journal-title":"J. Appl. Physiol."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"1678","DOI":"10.1080\/10255842.2017.1406081","article-title":"Analysis of breathing via optoelectronic systems: Comparison of four methods for computing breathing volumes and thoraco-abdominal motion pattern","volume":"20","author":"Massaroni","year":"2017","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1123\/jab.2016-0271","article-title":"A novel method to compute breathing volumes via motion capture systems: Design and experimental trials","volume":"33","author":"Massaroni","year":"2017","journal-title":"J. Appl. Biomech."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"327","author":"Bland","year":"1986","journal-title":"Lancet"},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"Aliverti, A., and Pedotti, A. (2002). Opto-electronic plethysmography. Mechanics of Breathing, Springer.","DOI":"10.1007\/978-88-470-2916-3"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1378\/chest.11-2964","article-title":"Lung volumes: Measurement, clinical use, and coding","volume":"142","author":"Flesch","year":"2012","journal-title":"Chest"},{"key":"ref_50","doi-asserted-by":"crossref","unstructured":"Silva, L., Dias, M., Folgado, D., Nunes, M., Namburi, P., Anthony, B., Carvalho, D., Carvalho, M., Edelman, E., and Gamboa, H. (2022). Respiratory Inductance Plethysmography to Assess Fatigability during Repetitive Work. Sensors, 22.","DOI":"10.3390\/s22114247"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1007\/s10877-021-00753-6","article-title":"Clinical evaluation of a wearable sensor for mobile monitoring of respiratory rate on hospital wards","volume":"36","author":"Takala","year":"2022","journal-title":"J. Clin. Monit. Comput."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1016\/j.resp.2007.12.003","article-title":"Chest wall kinematics during voluntary cough in neuromuscular patients","volume":"161","author":"Lanini","year":"2008","journal-title":"Respir. Physiol. Neurobiol."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1007\/s11517-020-02125-9","article-title":"A novel acquisition platform for long-term breathing frequency monitoring based on inertial measurement units","volume":"58","author":"Cesareo","year":"2020","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1152\/jappl.1967.22.3.407","article-title":"Measurement of the separate volume changes of rib cage and abdomen during breathing","volume":"22","author":"Konno","year":"1967","journal-title":"J. Appl. Physiol."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/17\/6708\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T00:23:44Z","timestamp":1760142224000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/17\/6708"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,5]]},"references-count":54,"journal-issue":{"issue":"17","published-online":{"date-parts":[[2022,9]]}},"alternative-id":["s22176708"],"URL":"https:\/\/doi.org\/10.3390\/s22176708","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,5]]}}}