{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,13]],"date-time":"2026-11-13T15:47:35Z","timestamp":1794584855861,"version":"4.9.1"},"reference-count":64,"publisher":"MDPI AG","issue":"18","license":[{"start":{"date-parts":[[2022,9,17]],"date-time":"2022-09-17T00:00:00Z","timestamp":1663372800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft (DFG, German Research Foundation)","doi-asserted-by":"publisher","award":["401786308"],"award-info":[{"award-number":["401786308"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Blood pressure (BP) is among the most important vital signals. Estimation of absolute BP solely using photoplethysmography (PPG) has gained immense attention over the last years. Available works differ in terms of used features as well as classifiers and bear large differences in their results. This work aims to provide a machine learning method for absolute BP estimation, its interpretation using computational methods and its critical appraisal in face of the current literature. We used data from three different sources including 273 subjects and 259,986 single beats. We extracted multiple features from PPG signals and its derivatives. BP was estimated by xgboost regression. For interpretation we used Shapley additive values (SHAP). Absolute systolic BP estimation using a strict separation of subjects yielded a mean absolute error of 9.456mmHg and correlation of 0.730. The results markedly improve if data separation is changed (MAE: 6.366mmHg, r: 0.874). Interpretation by means of SHAP revealed four features from PPG, its derivation and its decomposition to be most relevant. The presented approach depicts a general way to interpret multivariate prediction algorithms and reveals certain features to be valuable for absolute BP estimation. Our work underlines the considerable impact of data selection and of training\/testing separation, which must be considered in detail when algorithms are to be compared. In order to make our work traceable, we have made all methods available to the public.<\/jats:p>","DOI":"10.3390\/s22187037","type":"journal-article","created":{"date-parts":[[2022,9,19]],"date-time":"2022-09-19T04:49:22Z","timestamp":1663562962000},"page":"7037","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":18,"title":["Beat-to-Beat Blood Pressure Estimation by Photoplethysmography and Its Interpretation"],"prefix":"10.3390","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1852-9266","authenticated-orcid":false,"given":"Vincent","family":"Fleischhauer","sequence":"first","affiliation":[{"name":"Faculty of Information Technology, University of Applied Sciences and Arts Dortmund, 44139 Dortmund, Germany"},{"name":"TU Dresden, Institute for Biomedical Engineering, 01069 Dresden, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0014-8879","authenticated-orcid":false,"given":"Aarne","family":"Feldheiser","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology, Intensive Care Medicine and Pain Therapy, Evang. Kliniken Essen-Mitte, Huyssens-Stiftung\/Knappschaft, 45136 Essen, Germany"},{"name":"Department of Anaesthesiology and Operative Intensive Care Medicine (CCM, CVK), Charit\u00e9\u2014Universit\u00e4tsmedizin Berlin, Corporate Member of Freie Universit\u00e4t Berlin, Humboldt-Universit\u00e4t zu Berlin, and Berlin Institute of Health, 13353 Berlin, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6114-3142","authenticated-orcid":false,"given":"Sebastian","family":"Zaunseder","sequence":"additional","affiliation":[{"name":"Faculty of Information Technology, University of Applied Sciences and Arts Dortmund, 44139 Dortmund, Germany"},{"name":"TU Dresden, Institute for Biomedical Engineering, 01069 Dresden, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,9,17]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1016\/j.bpa.2014.08.001","article-title":"Measurement of blood pressure","volume":"28","author":"Saugel","year":"2014","journal-title":"Best Pract. Res. Clin. Anaesthesiol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1186\/1757-7241-22-8","article-title":"Noninvasive continuous versus intermittent arterial pressure monitoring: Evaluation of the vascular unloading technique (CNAP device) in the emergency department","volume":"22","author":"Wagner","year":"2014","journal-title":"Scand. J. Trauma Resusc. Emerg. Med."},{"key":"ref_3","unstructured":"Car\u00f3s, J.M.S.I. (2011). Continuous Non\u2014Invasive Blood Pressure Estimation. [Doctoral Thesis, ETH Z\u00fcrich]."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1007\/s13246-019-00813-x","article-title":"Non-invasive continuous blood pressure monitoring systems: Current and proposed technology issues and challenges","volume":"43","author":"Rastegar","year":"2020","journal-title":"Phys. Eng. Sci. Med."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1531","DOI":"10.2215\/CJN.03680320","article-title":"Cuffless Blood Pressure Monitoring","volume":"15","author":"Pandit","year":"2020","journal-title":"Clin. J. Am. Soc. Nephrol."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Quan, X., Liu, J., Roxlo, T., Siddharth, S., Leong, W., Muir, A., Cheong, S.M., and Rao, A. (2021). Advances in Non-Invasive Blood Pressure Monitoring. Sensors, 21.","DOI":"10.3390\/s21134273"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1515\/bmt-2020-0209","article-title":"Surrogate based continuous noninvasive blood pressure measurement","volume":"66","author":"Pielmus","year":"2021","journal-title":"Biomed. Eng.\/Biomed. Tech."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"3299","DOI":"10.1109\/TIM.2017.2745081","article-title":"Nonlinear Cuffless Blood Pressure Estimation of Healthy Subjects Using Pulse Transit Time and Arrival Time","volume":"66","author":"Esmaili","year":"2017","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_9","first-page":"1","article-title":"An Optimization Study of Estimating Blood Pressure Models Based on Pulse Arrival Time for Continuous Monitoring","volume":"2020","author":"Shao","year":"2020","journal-title":"J. Healthc. Eng."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"138077","DOI":"10.1109\/ACCESS.2020.3012384","article-title":"Pulse Transit Time-Pulse Wave Analysis Fusion Based on Wearable Wrist Ballistocardiogram for Cuff-Less Blood Pressure Trend Tracking","volume":"8","author":"Yousefian","year":"2020","journal-title":"IEEE Access"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"212478","DOI":"10.1109\/ACCESS.2020.3040257","article-title":"Continuous Non-Invasive Blood Pressure Monitoring: A Methodological Review on Measurement Techniques","volume":"8","author":"Le","year":"2020","journal-title":"IEEE Access"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"101870","DOI":"10.1016\/j.bspc.2020.101870","article-title":"A review of machine learning techniques in photoplethysmography for the non-invasive cuff-less measurement of blood pressure","volume":"58","author":"Kyriacou","year":"2020","journal-title":"Biomed. Signal Process. Control"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"125009","DOI":"10.1088\/1361-6579\/abc8dd","article-title":"A novel method for continuous blood pressure estimation based on a single-channel photoplethysmogram signal","volume":"41","author":"Hu","year":"2020","journal-title":"Physiol. Meas."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Goudarzi, R.H., Somayyeh Mousavi, S., and Charmi, M. (2020, January 18\u201320). Using imaging Photoplethysmography (iPPG) Signal for Blood Pressure Estimation. Proceedings of the Iranian Conference on Machine Vision and Image Processing, MVIP, Tehran, Iran.","DOI":"10.1109\/MVIP49855.2020.9116902"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"103392","DOI":"10.1016\/j.compbiomed.2019.103392","article-title":"SVR ensemble-based continuous blood pressure prediction using multi-channel photoplethysmogram","volume":"113","author":"Ng","year":"2019","journal-title":"Comput. Biol. Med."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1141","DOI":"10.1007\/s11760-019-01460-1","article-title":"Improved PPG-based estimation of the blood pressure using latent space features","volume":"13","author":"Hassani","year":"2019","journal-title":"Signal Image Video Process."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Liu, Z., Miao, F., Wang, R., Liu, J., Wen, B., and Li, Y. (2019, January 23\u201327). Cuff-less Blood Pressure Measurement Based on Deep Convolutional Neural Network. Proceedings of the 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Berlin, Germany.","DOI":"10.1109\/EMBC.2019.8856588"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Lee, D., Kwon, H., Son, D., Eom, H., Park, C., Lim, Y., Seo, C., and Park, K. (2020). Beat-to-Beat Continuous Blood Pressure Estimation Using Bidirectional Long Short-Term Memory Network. Sensors, 21.","DOI":"10.3390\/s21010096"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"13539","DOI":"10.1038\/s41598-021-92997-0","article-title":"Combined deep CNN\u2013LSTM network-based multitasking learning architecture for noninvasive continuous blood pressure estimation using difference in ECG-PPG features","volume":"11","author":"Jeong","year":"2021","journal-title":"Sci. Rep."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Schrumpf, F., Frenzel, P., Aust, C., Osterhoff, G., and Fuchs, M. (2021). Assessment of Non-Invasive Blood Pressure Prediction from PPG and rPPG Signals Using Deep Learning. Sensors, 21.","DOI":"10.3390\/s21186022"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Tang, Q., Chen, Z., Ward, R., Menon, C., and Elgendi, M. (2022). Subject-Based Model for Reconstructing Arterial Blood Pressure from Photoplethysmogram. Bioengineering, 9.","DOI":"10.3390\/bioengineering9080402"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"10000","DOI":"10.1109\/JSEN.2020.2990864","article-title":"PP-Net: A Deep Learning Framework for PPG-Based Blood Pressure and Heart Rate Estimation","volume":"20","author":"Panwar","year":"2020","journal-title":"IEEE Sens. J."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Ahmad, M.A., Teredesai, A., and Eckert, C. (2018, January 4\u20137). Interpretable Machine Learning in Healthcare. Proceedings of the 2018 IEEE International Conference on Healthcare Informatics (ICHI), New York, NY, USA.","DOI":"10.1109\/ICHI.2018.00095"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1136\/medethics-2020-107102","article-title":"Machine learning in medicine: Should the pursuit of enhanced interpretability be abandoned?","volume":"48","author":"Yoon","year":"2021","journal-title":"J. Med. Ethics"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1186\/s13195-021-00879-4","article-title":"Data analysis with Shapley values for automatic subject selection in Alzheimer\u2019s disease data sets using interpretable machine learning","volume":"13","author":"Bloch","year":"2021","journal-title":"Alzheimer\u2019s Res. Ther."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Bloch, L., and Friedrich, C. (2021, January 11\u201313). Developing a Machine Learning Workflow to Explain Black-box Models for Alzheimer\u2019s Disease Classification. Proceedings of the 14th International Joint Conference on Biomedical Engineering Systems and Technologies, SCITEPRESS\u2014Science and Technology Publications, Vienna, Austria.","DOI":"10.5220\/0010211300870099"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"210410","DOI":"10.1109\/ACCESS.2020.3040166","article-title":"Explainable Prediction of Acute Myocardial Infarction using Machine Learning and Shapley Values","volume":"8","author":"Ibrahim","year":"2020","journal-title":"IEEE Access"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1038\/s41746-019-0136-7","article-title":"The use of photoplethysmography for assessing hypertension","volume":"2","author":"Elgendi","year":"2019","journal-title":"Npj Digit. Med."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Welykholowa, K., Hosanee, M., Chan, G., Cooper, R., Kyriacou, P.A., Zheng, D., Allen, J., Abbott, D., Menon, C., and Lovell, N.H. (2020). Multimodal Photoplethysmography-Based Approaches for Improved Detection of Hypertension. J. Clin. Med., 9.","DOI":"10.3390\/jcm9041203"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"12498","DOI":"10.1109\/JSEN.2021.3073850","article-title":"The Machine Learnings Leading the Cuffless PPG Blood Pressure Sensors Into the Next Stage","volume":"21","author":"Chao","year":"2021","journal-title":"IEEE Sens. J."},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Bassiouni, M.M., Hegazy, I., Rizk, N., El-Dahshan, E.S.A., and Salem, A.M. (2021, January 5\u20137). Combination of ECG And PPG Signals For Smart HealthCare Systems: Techniques, Applications, and Challenges. Proceedings of the 2021 Tenth International Conference on Intelligent Computing and Information Systems (ICICIS), Cairo, Egypt.","DOI":"10.1109\/ICICIS52592.2021.9694241"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"102301","DOI":"10.1016\/j.bspc.2020.102301","article-title":"Deep learning models for cuffless blood pressure monitoring from PPG signals using attention mechanism","volume":"65","author":"Kyriacou","year":"2021","journal-title":"Biomed. Signal Process. Control"},{"key":"ref_33","first-page":"325","article-title":"HYPE: Predicting Blood Pressure from Photoplethysmograms in a Hypertensive Population","volume":"Volume 12299","author":"Datta","year":"2020","journal-title":"Lecture Notes in Computer Science (Including Subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"4300","DOI":"10.1109\/JSEN.2019.2961411","article-title":"Blood Pressure Estimation Using Photoplethysmogram Signal and Its Morphological Features","volume":"20","author":"Hasanzadeh","year":"2020","journal-title":"IEEE Sens. J."},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Hsu, Y.C., Li, Y.H., Chang, C.C., and Harfiya, L.N. (2020). Generalized Deep Neural Network Model for Cuffless Blood Pressure Estimation with Photoplethysmogram Signal Only. Sensors, 20.","DOI":"10.3390\/s20195668"},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"El Hajj, C., and Kyriacou, P.A. (2020, January 20\u201324). Cuffless and Continuous Blood Pressure Estimation From PPG Signals Using Recurrent Neural Networks. Proceedings of the 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC), Montreal, QC, Canada.","DOI":"10.1109\/EMBC44109.2020.9175699"},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Slapni\u010dar, G., Mlakar, N., and Lu\u0161trek, M. (2019). Blood Pressure Estimation from Photoplethysmogram Using a Spectro-Temporal Deep Neural Network. Sensors, 19.","DOI":"10.3390\/s19153420"},{"key":"ref_38","first-page":"1","article-title":"A Novel Neural Network Model for Blood Pressure Estimation Using Photoplethesmography without Electrocardiogram","volume":"2018","author":"Wang","year":"2018","journal-title":"J. Healthc. Eng."},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Dey, J., Gaurav, A., and Tiwari, V.N. (2018, January 18\u201321). InstaBP: Cuff-less Blood Pressure Monitoring on Smartphone using Single PPG Sensor. Proceedings of the 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Honolulu, HI, USA.","DOI":"10.1109\/EMBC.2018.8513189"},{"key":"ref_40","first-page":"128","article-title":"A SVM method for continuous blood pressure estimation from a PPG signal","volume":"Part F1283","author":"Zhang","year":"2017","journal-title":"Acm Int. Conf. Proc. Ser."},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"Jain, M., Deb, S., and Subramanyam, A.V. (2017, January 21\u201323). Face video based touchless blood pressure and heart rate estimation. Proceedings of the 2016 IEEE 18th International Workshop on Multimedia Signal Processing, MMSP 2016, Montreal, QC, Canada.","DOI":"10.1109\/MMSP.2016.7813389"},{"key":"ref_42","doi-asserted-by":"crossref","unstructured":"Gaurav, A., Maheedhar, M., Tiwari, V.N., and Narayanan, R. (2016, January 16\u201320). Cuff-less PPG based continuous blood pressure monitoring\u2014A smartphone based approach. Proceedings of the 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Orlando, FL, USA.","DOI":"10.1109\/EMBC.2016.7590775"},{"key":"ref_43","doi-asserted-by":"crossref","unstructured":"Gao, S.C., Wittek, P., Zhao, L., and Jiang, W.J. (2016, January 16\u201320). Data-driven estimation of blood pressure using photoplethysmographic signals. Proceedings of the 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Orlando, FL, USA.","DOI":"10.1109\/EMBC.2016.7590814"},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Duan, K., Qian, Z., Atef, M., and Wang, G. (2016, January 16\u201320). A feature exploration methodology for learning based cuffless blood pressure measurement using photoplethysmography. Proceedings of the 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Orlando, FL, USA.","DOI":"10.1109\/EMBC.2016.7592189"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1177\/0954411915587957","article-title":"Inverse-model-based cuffless blood pressure estimation using a single photoplethysmography sensor","volume":"229","author":"Suzuki","year":"2015","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"ref_46","first-page":"15","article-title":"Spatio-temporal analysis of blood perfusion by imaging photoplethysmography","volume":"10501","author":"Zaunseder","year":"2018","journal-title":"Opt. Diagn. Sens. XVIII Toward Point- Diagn."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"180020","DOI":"10.1038\/sdata.2018.20","article-title":"A new, short-recorded photoplethysmogram dataset for blood pressure monitoring in China","volume":"5","author":"Liang","year":"2018","journal-title":"Sci. Data"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"584","DOI":"10.1213\/ANE.0b013e318241f7c0","article-title":"University of Queensland Vital Signs Dataset","volume":"114","author":"Liu","year":"2012","journal-title":"Anesth. Analg."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1109\/JBHI.2013.2267096","article-title":"Pulse Rate Variability Analysis for Discrimination of Sleep-Apnea-Related Decreases in the Amplitude Fluctuations of Pulse Photoplethysmographic Signal in Children","volume":"18","author":"Lazaro","year":"2014","journal-title":"IEEE J. Biomed. Health Inf."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"095009","DOI":"10.1088\/1361-6579\/abb005","article-title":"Pulse decomposition analysis in photoplethysmography imaging","volume":"41","author":"Fleischhauer","year":"2020","journal-title":"Physiol. Meas."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1007\/s10558-010-9098-8","article-title":"A new two-pulse synthesis model for digital volume pulse signal analysis","volume":"10","author":"Goswami","year":"2010","journal-title":"Cardiovasc. Eng."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"1801","DOI":"10.1088\/0967-3334\/36\/9\/1801","article-title":"Assessment of cardiovascular function from multi-Gaussian fitting of a finger photoplethysmogram","volume":"36","author":"Couceiro","year":"2015","journal-title":"Physiol. Meas."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s11082-020-02667-0","article-title":"Non-invasive cuff-less blood pressure estimation using a hybrid deep learning model","volume":"53","author":"Yang","year":"2021","journal-title":"Opt. Quantum Electron."},{"key":"ref_54","doi-asserted-by":"crossref","unstructured":"Liang, Y., Chen, Z., Ward, R., and Elgendi, M. (2018). Hypertension Assessment via ECG and PPG Signals: An Evaluation Using MIMIC Database. Diagnostics, 8.","DOI":"10.3390\/diagnostics8030065"},{"key":"ref_55","doi-asserted-by":"crossref","unstructured":"Chowdhury, M.H., Shuzan, M.N.I., Chowdhury, M.E., Mahbub, Z.B., Uddin, M.M., Khandakar, A., and Reaz, M.B.I. (2020). Estimating Blood Pressure from the Photoplethysmogram Signal and Demographic Features Using Machine Learning Techniques. Sensors, 20.","DOI":"10.3390\/s20113127"},{"key":"ref_56","doi-asserted-by":"crossref","unstructured":"Chen, T., and Guestrin, C. (2016, January 13\u201317). XGBoost: A Scalable Tree Boosting System. Proceedings of the 22nd ACM SIGKDD International Conference on Knowledge Discovery and Data Mining (KDD \u201916), San Francisco, CA, USA.","DOI":"10.1145\/2939672.2939785"},{"key":"ref_57","unstructured":"Molnar, C. (2022). Interpretable Machine Learning, Lulu. com. [2nd ed.]."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1038\/s41551-018-0304-0","article-title":"Explainable machine-learning predictions for the prevention of hypoxaemia during surgery","volume":"2","author":"Lundberg","year":"2018","journal-title":"Nat. Biomed. Eng."},{"key":"ref_59","unstructured":"Lundberg, S., and Lee, S.I. (2017). A Unified Approach to Interpreting Model Predictions. arXiv."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"3134","DOI":"10.1109\/TBME.2020.2976989","article-title":"PPG Sensor Contact Pressure Should Be Taken Into Account for Cuff-Less Blood Pressure Measurement","volume":"67","author":"Chandrasekhar","year":"2020","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_61","doi-asserted-by":"crossref","unstructured":"Cao, Y., Chen, H., Li, F., and Wang, Y. (2021, January 25\u201329). Crisp-BP: Continuous Wrist PPG-based Blood Pressure Measurement. Proceedings of the 27th Annual International Conference on Mobile Computing and Networking, New Orleans, LA, USA.","DOI":"10.1145\/3447993.3483241"},{"key":"ref_62","first-page":"1","article-title":"A Review of Wearable Multi-wavelength Photoplethysmography","volume":"15","author":"Ray","year":"2021","journal-title":"IEEE Rev. Biomed. Eng."},{"key":"ref_63","first-page":"1","article-title":"CatBoost: Unbiased boosting with categorical features","volume":"Volume 31","author":"Bengio","year":"2018","journal-title":"Advances in Neural Information Processing Systems"},{"key":"ref_64","first-page":"1","article-title":"LightGBM: A Highly Efficient Gradient Boosting Decision Tree","volume":"Volume 30","author":"Guyon","year":"2017","journal-title":"Advances in Neural Information Processing Systems"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/18\/7037\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T00:33:23Z","timestamp":1760142803000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/18\/7037"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,17]]},"references-count":64,"journal-issue":{"issue":"18","published-online":{"date-parts":[[2022,9]]}},"alternative-id":["s22187037"],"URL":"https:\/\/doi.org\/10.3390\/s22187037","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,17]]}}}