{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,26]],"date-time":"2026-03-26T15:42:27Z","timestamp":1774539747491,"version":"3.50.1"},"reference-count":26,"publisher":"MDPI AG","issue":"19","license":[{"start":{"date-parts":[[2022,9,21]],"date-time":"2022-09-21T00:00:00Z","timestamp":1663718400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>At present, the online insulation monitoring and fault diagnosis of mining cables are extensively discussed, while their operation status assessment has not been deeply studied. Considering that mining cables are closely related to the safe and stable operation of coal mine power supply systems, a comprehensive evaluation method including the Analytic Hierarchy Process (AHP), the membership cloud theory, and the D-S evidence theory is proposed in this paper in order to accurately assess the operation status of the mining XLPE cable. Firstly, the membership cloud is introduced to solve the index membership degree and the weights are calculated by an improved weight vector calculation method. Secondly, the conversion from the base layer indicator membership degree to the target layer trust degree is realized based on the D-S evidence theory. Then, the cable operation status is judged via the trust degree maximum and the distribution of conflict coefficients is further analyzed to warn the indicators with a bad status in the base layer. Finally, the feasibility of the proposed evaluation method is verified by a sufficient and detailed case analysis.<\/jats:p>","DOI":"10.3390\/s22197174","type":"journal-article","created":{"date-parts":[[2022,9,22]],"date-time":"2022-09-22T23:07:55Z","timestamp":1663888075000},"page":"7174","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["A Comprehensive Operation Status Evaluation Method for Mining XLPE Cables"],"prefix":"10.3390","volume":"22","author":[{"given":"Yanwen","family":"Wang","sequence":"first","affiliation":[{"name":"School of Mechanical, Electronic & Information Engineering, China University of Mining and Technology-Beijing, Beijing 100083, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peng","family":"Chen","sequence":"additional","affiliation":[{"name":"School of Mechanical, Electronic & Information Engineering, China University of Mining and Technology-Beijing, Beijing 100083, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yanying","family":"Sun","sequence":"additional","affiliation":[{"name":"School of Mechanical, Electronic & Information Engineering, China University of Mining and Technology-Beijing, Beijing 100083, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chen","family":"Feng","sequence":"additional","affiliation":[{"name":"The Key Laboratory of Power System Intelligent Dispatch and Control, Shandong University, Jinan 250061, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2022,9,21]]},"reference":[{"key":"ref_1","unstructured":"Wang, Y., and Zhang, L. (2017, January 25\u201326). Research on single-phase-to-earth fault section location in coal mine high-voltage power supply system. Proceedings of the 2017 IEEE 2nd Advanced Information Technology, Electronic and Automation Control Conference (IAEAC), Chongqing, China."},{"key":"ref_2","first-page":"295","article-title":"2025 scenarios and development path of intelligent coal mine","volume":"43","author":"Wang","year":"2017","journal-title":"J. China Coal Soc."},{"key":"ref_3","first-page":"34","article-title":"Analysis on key technologies of intelligent coal mine and intelligent mining","volume":"44","author":"Wang","year":"2016","journal-title":"J. China Coal Soc."},{"key":"ref_4","first-page":"2296","article-title":"Discussion on theory and technology of building robust intelligent power grid in coal mine of China","volume":"45","author":"Liu","year":"2020","journal-title":"J. China Coal Soc."},{"key":"ref_5","first-page":"346","article-title":"A model for evaluating the production system of an intelligent mine based on unascertained measurement theory","volume":"38","author":"Li","year":"2019","journal-title":"J. Intell. Fuzzy Syst."},{"key":"ref_6","first-page":"727","article-title":"Space Charge Characteristics for XLPE Coaxial Cable Insulation Under Electrothermal Accelerated Aging","volume":"29","author":"Chen","year":"2022","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1109\/TDEI.2018.007442","article-title":"Evaluation of voltage endurance characteristics for new and aged XLPE cable insulation by electrical treeing test","volume":"26","author":"Su","year":"2019","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1942","DOI":"10.1109\/TDEI.2020.009025","article-title":"Study on Aging Characteristics of XLPE Cable Insulation Based on Quantum Chemical Calculation","volume":"27","author":"Zhu","year":"2020","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1109\/TDEI.2015.004995","article-title":"On-line monitoring method for long distance power cable insulation","volume":"23","author":"Pang","year":"2016","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"754","DOI":"10.1109\/TDEI.2013.6518945","article-title":"Application of K-Means method to pattern recognition in on-line cable partial discharge monitoring","volume":"20","author":"Peng","year":"2016","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"2087","DOI":"10.1109\/TDEI.2015.004398","article-title":"A novel on-line cable pd localisation method based on cable transfer function and detected pd pulse rise-time","volume":"22","author":"Sheng","year":"2015","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1347","DOI":"10.1109\/TDEI.2015.005579","article-title":"Increased operation reliability of HV apparatus through PD monitoring","volume":"23","author":"Koltunowicz","year":"2016","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_13","first-page":"1","article-title":"Online Monitoring of Power Cables Tangent Delta Based on Low-Frequency Signal Injection Method","volume":"70","author":"Zhu","year":"2021","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"42","DOI":"10.23919\/CJEE.2019.000019","article-title":"Online monitoring method based on locus-analysis for high-voltage cable faults","volume":"5","author":"Zhao","year":"2019","journal-title":"Chin. J. Electr. Eng."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"144444","DOI":"10.1109\/ACCESS.2019.2944570","article-title":"Distributed Online Monitoring Method and Application of Cable Partial Discharge Based on \u03c6 -OTDR","volume":"7","author":"Pan","year":"2019","journal-title":"IEEE Access"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"7360","DOI":"10.1109\/TIE.2021.3102410","article-title":"Online Monitoring for Underground Power Cable Insulation Based on Common-Mode Signal Injection","volume":"69","author":"Wu","year":"2021","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Liu, H., Li, L., Zhang, K., Zhang, H., Li, Z., and Liang, J. (2022, January 25\u201327). The Insulation Aging State Assessment of High Voltage Cable Based on the Isothermal Relaxation Current. Proceedings of the 2022 IEEE International Conference on Electrical Engineering, Big Data and Algorithms (EEBDA), Changchun, China.","DOI":"10.1109\/EEBDA53927.2022.9745002"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"176651","DOI":"10.1109\/ACCESS.2020.3026650","article-title":"Transient Disturbances Based Non-Intrusive Ageing Condition Assessment for Cross-Bonded Cables","volume":"8","author":"Li","year":"2020","journal-title":"IEEE Access"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"118975","DOI":"10.1109\/ACCESS.2019.2936419","article-title":"A Holistic Approach to Risk-Based Maintenance Scheduling for HV Cables","volume":"7","author":"Liao","year":"2019","journal-title":"IEEE Access"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"111020","DOI":"10.1109\/ACCESS.2021.3066654","article-title":"Assessment of Thermal Aging Degree of 10kV Cross-Linked Polyethylene Cable Based on Depolarization Current","volume":"9","author":"Zhang","year":"2020","journal-title":"IEEE Access"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"33492","DOI":"10.1109\/ACCESS.2022.3161742","article-title":"MCDM and Various Prioritization Methods in AHP for CSS: A Comprehensive Review","volume":"10","author":"Gyani","year":"2022","journal-title":"IEEE Access"},{"key":"ref_22","first-page":"1","article-title":"Security assessment of coal mine power grid voltage based on an improved AHP-FCE","volume":"2022","author":"Wang","year":"2022","journal-title":"Math. Probl. Eng."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1318","DOI":"10.1109\/TSG.2016.2619375","article-title":"Novel Estimation Method of Metering Errors of Electric Energy Based on Membership Cloud and Dynamic Time Warping","volume":"8","author":"Zhou","year":"2022","journal-title":"IEEE Trans. Smart Grid"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.1109\/TSG.2015.2388778","article-title":"Research on Multiobjective Group Decision-Making in Condition-Based Maintenance for Transmission and Transformation Equipment Based on D-S Evidence Theory","volume":"6","author":"Wang","year":"2015","journal-title":"IEEE Trans. Smart Grid"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"597","DOI":"10.35833\/MPCE.2020.000470","article-title":"Comprehensive Evaluation of Electric Power Prediction Models Based on D-S Evidence Theory Combined with Multiple Accuracy Indicators","volume":"10","author":"Cui","year":"2022","journal-title":"J. Mod. Power Syst. Clean Energy"},{"key":"ref_26","first-page":"34","article-title":"Methods to Determine Generalized Basic Probability Assignment in Generalized Evidence Theory","volume":"45","author":"Deng","year":"2011","journal-title":"J. Xi\u2019an Jiaotong Univ."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/19\/7174\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T00:36:57Z","timestamp":1760143017000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/19\/7174"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,21]]},"references-count":26,"journal-issue":{"issue":"19","published-online":{"date-parts":[[2022,10]]}},"alternative-id":["s22197174"],"URL":"https:\/\/doi.org\/10.3390\/s22197174","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,21]]}}}