{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T18:29:13Z","timestamp":1775068153457,"version":"3.50.1"},"reference-count":31,"publisher":"MDPI AG","issue":"23","license":[{"start":{"date-parts":[[2022,12,2]],"date-time":"2022-12-02T00:00:00Z","timestamp":1669939200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Zhejiang Provincial Natural Science Foundation of China","award":["LQ22E070008"],"award-info":[{"award-number":["LQ22E070008"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Factors such as insufficient heat dissipation and excessively high temperature can easily lead to demagnetization of the PMs in permanent-magnet (PM) motors. As a result, the magnetic field distribution of the motor will not be uniform, producing fault harmonics and lowering the operational performance of the motor. An essential stage in the diagnosis of faults and the monitoring of motor condition is the establishment of an accurate model of motors with demagnetization faults. In this paper, demagnetization faults are modeled by changing the Fourier coefficients in the Fourier expansion of the magnetization of PMs. This model can be used to determine the motor performance under various types of demagnetization, including radial air gap flux density, back electromotive force (EMF), and torque. On this basis, the corresponding relationship between the demagnetization degree and the fault signature is established, to provide a theoretical foundation for the subsequent demagnetization fault diagnosis. The finite element analysis (FEA) verifies the effectiveness and superiority of the proposed analytical model. The modeling method proposed in this paper can be applied to PM motors with PMs having different magnetization directions and shapes because it is based on the demagnetization region of PMs.<\/jats:p>","DOI":"10.3390\/s22239440","type":"journal-article","created":{"date-parts":[[2022,12,5]],"date-time":"2022-12-05T08:10:57Z","timestamp":1670227857000},"page":"9440","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Analytical Modeling and Analysis of Permanent-Magnet Motor with Demagnetization Fault"],"prefix":"10.3390","volume":"22","author":[{"given":"Cenwei","family":"Shi","sequence":"first","affiliation":[{"name":"College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2824-5443","authenticated-orcid":false,"given":"Lin","family":"Peng","sequence":"additional","affiliation":[{"name":"College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China"}]},{"given":"Zhen","family":"Zhang","sequence":"additional","affiliation":[{"name":"College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5824-9453","authenticated-orcid":false,"given":"Tingna","family":"Shi","sequence":"additional","affiliation":[{"name":"College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China"}]}],"member":"1968","published-online":{"date-parts":[[2022,12,2]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1109\/TEC.2003.822325","article-title":"Noninvasive Detection of Brushless Exciter Rotating Diode Failure","volume":"19","author":"McArdle","year":"2004","journal-title":"IEEE Trans. Energy Convers."},{"key":"ref_2","unstructured":"Vijayraghavan, P., and Krishnan, R. (1998, January 12\u201315). Noise in Electric Machines: A Review. Proceedings of the Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242), St. Louis, MO, USA."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1109\/TMAG.2015.2480379","article-title":"Demagnetization Fault Indexes in Permanent Magnet Synchronous Motors\u2014An Overview","volume":"52","author":"Faiz","year":"2016","journal-title":"IEEE Trans. Magn."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1109\/TEC.2011.2176127","article-title":"Detection of Demagnetization Faults in Surface-Mounted Permanent Magnet Synchronous Motors by Means of the Zero-Sequence Voltage Component","volume":"27","author":"Urresty","year":"2012","journal-title":"IEEE Trans. Energy Convers."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"21","DOI":"10.23919\/CJEE.2015.7933135","article-title":"Overview of Fault Diagnosis Theory and Method for Permanent Magnet Machine","volume":"1","author":"Cheng","year":"2015","journal-title":"Chin. J. Electr. Eng."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Candelo-Zuluaga, C., Riba, J.-R., Thangamuthu, D.V., and Garcia, A. (2020). Detection of Partial Demagnetization Faults in Five-Phase Permanent Magnet Assisted Synchronous Reluctance Machines. Energies, 13.","DOI":"10.3390\/en13133496"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/j.matcom.2018.06.002","article-title":"Assessment of Current and Voltage Signature Analysis for the Diagnosis of Rotor Magnet Demagnetization in Five-Phase AC Permanent Magnet Generator Drives","volume":"158","author":"Gritli","year":"2019","journal-title":"Math. Comput. Simul."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Barmpatza, A.C., and Kappatou, J.C. (2020). Study of a Combined Demagnetization and Eccentricity Fault in an AFPM Synchronous Generator. Energies, 13.","DOI":"10.3390\/en13215609"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Krichen, M., Elbouchikhi, E., Benhadj, N., Chaieb, M., Benbouzid, M., and Neji, R. (2020). Motor Current Signature Analysis-Based Permanent Magnet Synchronous Motor Demagnetization Characterization and Detection. Machines, 8.","DOI":"10.3390\/machines8030035"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"2934","DOI":"10.1109\/TEC.2021.3071598","article-title":"The Demagnetization Harmonics Generation Mechanism in Permanent Magnet Machines with Concentrated Windings","volume":"36","author":"Gyftakis","year":"2021","journal-title":"IEEE Trans. Energy Convers."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"2499","DOI":"10.1109\/TIA.2018.2886772","article-title":"Online Detection of Rotor Eccentricity and Demagnetization Faults in PMSMs Based on Hall-Effect Field Sensor Measurements","volume":"55","author":"Park","year":"2019","journal-title":"IEEE Trans. Ind. Appl."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1109\/TMAG.2016.2617318","article-title":"Comprehensive Analysis of Magnet Defect Fault Monitoring through Leakage Flux","volume":"53","author":"Goktas","year":"2017","journal-title":"IEEE Trans. Magn."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1109\/TIA.2019.2947401","article-title":"A Torque Angle-Based Fault Detection and Identification Technique for IPMSM","volume":"56","author":"Ullah","year":"2020","journal-title":"IEEE Trans. Ind. Appl."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Burriel-Valencia, J., Puche-Panadero, R., Martinez-Roman, J., Sapena-Bano, A., Pineda-Sanchez, M., Perez-Cruz, J., and Riera-Guasp, M. (2018). Automatic Fault Diagnostic System for Induction Motors under Transient Regime Optimized with Expert Systems. Electronics, 8.","DOI":"10.3390\/electronics8010006"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1559","DOI":"10.1109\/TII.2019.2928008","article-title":"A New Demagnetization Fault Recognition and Classification Method for DPMSLM","volume":"16","author":"Song","year":"2020","journal-title":"IEEE Trans. Ind. Inf."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"11352","DOI":"10.1016\/j.eswa.2009.03.022","article-title":"Fault Diagnosis of Power Transformer Based on Support Vector Machine with Genetic Algorithm","volume":"36","author":"Fei","year":"2009","journal-title":"Expert Syst. Appl."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Wang, C.-S., Kao, I.-H., and Perng, J.-W. (2021). Fault Diagnosis and Fault Frequency Determination of Permanent Magnet Synchronous Motor Based on Deep Learning. Sensors, 21.","DOI":"10.3390\/s21113608"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Arellano-Espitia, F., Delgado-Prieto, M., Martinez-Viol, V., Saucedo-Dorantes, J.J., and Osornio-Rios, R.A. (2020). Deep-Learning-Based Methodology for Fault Diagnosis in Electromechanical Systems. Sensors, 20.","DOI":"10.3390\/s20143949"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"109569","DOI":"10.1016\/j.ymssp.2022.109569","article-title":"Discriminative Feature Learning Using a Multiscale Convolutional Capsule Network from Attitude Data for Fault Diagnosis of Industrial Robots","volume":"182","author":"Long","year":"2023","journal-title":"Mech. Syst. Signal Process."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"109615","DOI":"10.1016\/j.ymssp.2022.109615","article-title":"A Novel Unsupervised Directed Hierarchical Graph Network with Clustering Representation for Intelligent Fault Diagnosis of Machines","volume":"183","author":"Zhao","year":"2023","journal-title":"Mech. Syst. Signal Process."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Lee, H., Jeong, H., Kim, S., and Kim, S.W. (2022). Severity Estimation for Interturn Short-Circuit and Demagnetization Faults through Self-Attention Network. Sensors, 22.","DOI":"10.3390\/s22124639"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"2366","DOI":"10.1109\/TIA.2021.3058541","article-title":"Online Rotor Fault Diagnosis of Permanent Magnet Synchronous Motors Based on Stator Tooth Flux","volume":"57","author":"Zeng","year":"2021","journal-title":"IEEE Trans. Ind. Appl."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"118030","DOI":"10.1109\/ACCESS.2020.3005038","article-title":"Modeling and Classification of Stator Inter-Turn Fault and Demagnetization Effects in BLDC Motor Using Rotor Back-EMF and Radial Magnetic Flux Analysis","volume":"8","author":"Usman","year":"2020","journal-title":"IEEE Access"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"2775","DOI":"10.1109\/TTE.2021.3073630","article-title":"Online Detecting Magnet Defect Fault in PMSG With Magnetic Sensing","volume":"7","author":"Xu","year":"2021","journal-title":"IEEE Trans. Transp. Electrif."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"5830","DOI":"10.1109\/TIE.2018.2873099","article-title":"General Analytical Modeling for Magnet Demagnetization in Surface Mounted Permanent Magnet Machines","volume":"66","author":"Guo","year":"2019","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_26","first-page":"1955","article-title":"Nonlinear Analytical Modelling for Surface-Mounted Permanent Magnet Motors with Magnet Defect Fault","volume":"37","author":"Li","year":"2022","journal-title":"IEEE Trans. Energy Convers."},{"key":"ref_27","first-page":"8203404","article-title":"Demagnetization Fault Detection in Axial Flux PM Machines by Using Sensing Coils and an Analytical Model","volume":"53","author":"Vansompel","year":"2017","journal-title":"IEEE Trans. Magn."},{"key":"ref_28","first-page":"8107712","article-title":"Analytical Model for Combined Study of Magnet Demagnetization and Eccentricity Defects in Axial Flux Permanent Magnet Synchronous Machines","volume":"53","author":"Sergeant","year":"2017","journal-title":"IEEE Trans. Magn."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1109\/TEC.2019.2958071","article-title":"Active Demagnetization Fault Compensation for Axial Flux Permanent-Magnet Synchronous Machines Using an Analytical Inverse Model","volume":"35","author":"Verkroost","year":"2020","journal-title":"IEEE Trans. Energy Convers."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"2041","DOI":"10.1109\/TIE.2013.2263777","article-title":"Advanced Eccentricity Fault Recognition in Permanent Magnet Synchronous Motors Using Stator Current Signature Analysis","volume":"61","author":"Ebrahimi","year":"2014","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_31","first-page":"1331","article-title":"A Comprehensive Analysis of Magnet Defect Faults in Permanent Magnet Synchronous Motors","volume":"52","author":"Zafarani","year":"2015","journal-title":"IEEE Trans. Ind. Appl."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/23\/9440\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T01:33:03Z","timestamp":1760146383000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/23\/9440"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,2]]},"references-count":31,"journal-issue":{"issue":"23","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["s22239440"],"URL":"https:\/\/doi.org\/10.3390\/s22239440","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,12,2]]}}}