{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T20:10:23Z","timestamp":1793736623097,"version":"4.6.1"},"reference-count":67,"publisher":"MDPI AG","issue":"23","license":[{"start":{"date-parts":[[2022,12,6]],"date-time":"2022-12-06T00:00:00Z","timestamp":1670284800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Foot Balance Technology Pty. Ltd."}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The foot is a vital organ, as it stabilizes the impact forces between the human skeletal system and the ground. Hence, precise foot dimensions are essential not only for custom footwear design, but also for the clinical treatment of foot health. Most existing research on measuring foot dimensions depends on a heavy setup environment, which is costly and ineffective for daily use. In addition, there are several smartphone applications online, but they are not suitable for measuring the exact foot shape for custom footwear, both in clinical practice and public use. In this study, we designed and implemented computer-vision-based smartphone application OptiFit that provides the functionality to automatically measure the four essential dimensions (length, width, arch height, and instep girth) of a human foot from images and 3D scans. We present an instep girth measurement algorithm, and we used a pixel per metric algorithm for measurement; these algorithms were accordingly integrated with the application. Afterwards, we evaluated our application using 19 medical-grade silicon foot models (12 males and 7 females) from different age groups. Our experimental evaluation shows that OptiFit could measure the length, width, arch height, and instep girth with an accuracy of 95.23%, 96.54%, 89.14%, and 99.52%, respectively. A two-tailed paired t-test was conducted, and only the instep girth dimension showed a significant discrepancy between the manual measurement (MM) and the application-based measurement (AM). We developed a linear regression model to adjust the error. Further, we performed comparative analysis demonstrating that there were no significant errors between MM and AM, and the application offers satisfactory performance as a foot-measuring application. Unlike other applications, the iOS application we developed, OptiFit, fulfils the requirements to automatically measure the exact foot dimensions for individually fitted footwear. Therefore, the application can facilitate proper foot measurement and enhance awareness to prevent foot-related problems caused by inappropriate footwear.<\/jats:p>","DOI":"10.3390\/s22239554","type":"journal-article","created":{"date-parts":[[2022,12,7]],"date-time":"2022-12-07T05:50:52Z","timestamp":1670392252000},"page":"9554","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["OptiFit: Computer-Vision-Based Smartphone Application to Measure the Foot from Images and 3D Scans"],"prefix":"10.3390","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0779-2410","authenticated-orcid":false,"given":"Riyad Bin","family":"Rafiq","sequence":"first","affiliation":[{"name":"Department of Computer Science and Engineering, University of North Texas, Denton, TX 76203-5017, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0030-4824","authenticated-orcid":false,"given":"Kazi Miftahul","family":"Hoque","sequence":"additional","affiliation":[{"name":"Department of Computer Science and Engineering, Chittagong University of Engineering and Technology, Chottogram 4349, Bangladesh"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6798-6535","authenticated-orcid":false,"given":"Muhammad Ashad","family":"Kabir","sequence":"additional","affiliation":[{"name":"School of Computing, Mathematics and Engineering, Charles Sturt University, Bathurst, NSW 2795, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9049-6825","authenticated-orcid":false,"given":"Sayed","family":"Ahmed","sequence":"additional","affiliation":[{"name":"School of Health and Human Sciences, Southern Cross University, East Lismore, NSW 2480, Australia"},{"name":"Foot Balance Technology Pty. Ltd., Westmead, NSW 2145, Australia"},{"name":"EYM (Ease Your Motion) Pty. Ltd., Westmead, NSW 2145, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5666-6168","authenticated-orcid":false,"given":"Craig","family":"Laird","sequence":"additional","affiliation":[{"name":"EYM (Ease Your Motion) Pty. Ltd., Westmead, NSW 2145, Australia"},{"name":"Walk Easy Pedorthics Pty. Ltd., Tamworth, NSW 2340, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,12,6]]},"reference":[{"key":"ref_1","unstructured":"Luximon, A. (2001). Foot Shape Evaluation for Footwear Fitting, Hong Kong University of Science and Technology (Hong Kong)."},{"key":"ref_2","unstructured":"Xiong, S. (2008). Pressure Perception on the Foot and the Mechanical Properties of Foot Tissue during Constrained Standing among Chinese, Hong Kong University of Science and Technology (Hong Kong)."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Shi, N., Yi, S., Xiong, S., and Jiang, Z. (2009, January 24\u201326). A CAD system for shoe last customization. Proceedings of the 2009 International Joint Conference on Computational Sciences and Optimization, CSO 2009, Sanya, China.","DOI":"10.1109\/CSO.2009.229"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"104343","DOI":"10.1016\/j.ijmedinf.2020.104343","article-title":"A smart wearable device for monitoring and self-management of diabetic foot: A proof of concept study","volume":"146","author":"Moulaei","year":"2021","journal-title":"Int. J. Med Inf."},{"key":"ref_5","unstructured":"Southeast Orthopedic Specialists (2022, October 10). Why Preventative Foot Care is Important. Available online: https:\/\/se-ortho.com\/foot-care-important\/."},{"key":"ref_6","unstructured":"Gray, A. (2022, October 10). A Strong Base: The Importance of Foot Health. Available online: https:\/\/pharmaceutical-journal.com\/article\/feature\/a-strong-base-the-importance-of-foot-health."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1016\/j.ergon.2006.06.004","article-title":"Foot measurements from three-dimensional scans: A comparison and evaluation of different methods","volume":"36","author":"Witana","year":"2006","journal-title":"Int. J. Ind. Ergon."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1213","DOI":"10.1080\/00140139408964899","article-title":"Quantitative morphology of the human foot in a North american population","volume":"37","author":"Hawes","year":"1994","journal-title":"Ergonomics"},{"key":"ref_9","first-page":"23","article-title":"Inter-generation differences in foot morphology: Aging or secular change?","volume":"32","author":"Kouchi","year":"2003","journal-title":"J. Hum. Ergol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1186\/s13047-014-0044-7","article-title":"Comparing 3D foot scanning with conventional measurement methods","volume":"7","author":"Lee","year":"2014","journal-title":"J. Foot Ankle Res."},{"key":"ref_11","unstructured":"The Brannock Device Co. Inc (2021, November 21). Brannock Device. Available online: https:\/\/brannock.com\/."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1186\/1757-1146-7-3","article-title":"Evaluation of the accuracy of shoe fitting in older people using three-dimensional foot scanning","volume":"7","author":"Menz","year":"2014","journal-title":"J. Foot Ankle Res."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1097\/NOR.0000000000000447","article-title":"Does the shoe fit? Considerations for proper shoe fitting","volume":"37","author":"Blazer","year":"2018","journal-title":"Orthop. Nurs."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1016\/j.measurement.2019.03.057","article-title":"Development of new shoe-sizing system for Malaysian women using 3D foot scanning technology","volume":"140","author":"Shariff","year":"2019","journal-title":"Measurement"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1080\/001401399185702","article-title":"Accuracy and reliability of a technique for quantifying foot shape, dimensions and structural characteristics","volume":"42","author":"Liu","year":"1999","journal-title":"Ergonomics"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Kouchi, M. (2014). Anthropometric methods for apparel design: Body measurement devices and techniques. Anthropometry, Apparel Sizing and Design, Elsevier.","DOI":"10.1533\/9780857096890.1.67"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"e24202","DOI":"10.2196\/24202","article-title":"Mobile apps for foot measurement in pedorthic practice: Scoping review","volume":"9","author":"Kabir","year":"2021","journal-title":"JMIR MHealth UHealth"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Szeliski, R. (2010). Computer Vision: Algorithms and Applications, Springer Science & Business Media.","DOI":"10.1007\/978-1-84882-935-0"},{"key":"ref_19","first-page":"012004","article-title":"A research on foot size measurement algorithm based on image","volume":"1903","author":"Wang","year":"2021","journal-title":"J. Physics: Conf. Ser."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Niu, L., Xiong, G., Shang, X., Guo, C., Chen, X., and Wu, H. (2021). 3D Foot Reconstruction Based on Mobile Phone Photographing. Appl. Sci., 11.","DOI":"10.3390\/app11094040"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Shilov, L., Shanshin, S., Romanov, A., Fedotova, A., Kurtukova, A., Kostyuchenko, E., and Sidorov, I. (2021). Reconstruction of a 3D Human Foot Shape Model Based on a Video Stream Using Photogrammetry and Deep Neural Networks. Future Internet, 13.","DOI":"10.3390\/fi13120315"},{"key":"ref_22","unstructured":"Taboada-Crispi, A. (2021, January 5\u20137). Automatic Classification of Diabetic Foot Ulcers Using Computer Vision Techniques. Proceedings of the Progress in Artificial Intelligence and Pattern Recognition: 7th International Workshop on Artificial Intelligence and Pattern Recognition, IWAIPR 2021, Havana, Cuba."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Delfi, G., Kamachi, M., and Dutta, T. (2021). Development of an Automated Minimum Foot Clearance Measurement System: Proof of Principle. Sensors, 21.","DOI":"10.3390\/s21030976"},{"key":"ref_24","unstructured":"Miller, R. (1976). Manual of Shoemaking, C. & J. Clark Ltd."},{"key":"ref_25","unstructured":"White, R.M. (1982). Comparative Anthropometry of the Foot, United States Army Natick Research and Development Laboratories. Technical Report."},{"key":"ref_26","unstructured":"Venkatappaiah, B. (1997). Introduction to the Modern Footwear Technology, B. Sita. [1st ed.]."},{"key":"ref_27","unstructured":"Pivecka, J., and Laure, S. (1995). The Shoe Last: Practical Handbook for Shoe Designers, Jan Pivecka Foundation."},{"key":"ref_28","unstructured":"Freedman, A., Huntington, E., Davis, G., Magee, R., Milstead, V., and Kirkpatrick, C. (1946). Foot Dimensions of Soldiers (Third Partial Report Project No. T-13), Armored Medical Research Laboratory."},{"key":"ref_29","first-page":"149","article-title":"Foot measurement for shoe construction with reference to the relationship between foot length, foot breadth, and ball girth","volume":"3","author":"Baba","year":"1974","journal-title":"J. Hum. Ergol."},{"key":"ref_30","unstructured":"Pheasant, S., and Haslegrave, C. (2006). Bodyspace: Anthropometry, Ergonomics and the Design of Work, CRC Press."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1109\/51.731323","article-title":"Evaluating different footprints parameters as a predictor of arch height","volume":"17","author":"Shiang","year":"1998","journal-title":"IEEE Eng. Med. Biol. Mag."},{"key":"ref_32","first-page":"1","article-title":"Reproducibility of foot dimensions measured from 3-dimensional foot scans in children and adolescents with Down syndrome","volume":"13","author":"Hassan","year":"2020","journal-title":"J. Foot Ankle Res."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1177\/107110078300400213","article-title":"The high incidence of mismated feet in the population","volume":"4","author":"Rossi","year":"1983","journal-title":"Foot Ankle"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1520\/JTE11086J","article-title":"Foot measurement strategies for fitting athletes","volume":"16","author":"Bunch","year":"1988","journal-title":"J. Test. Eval."},{"key":"ref_35","first-page":"178","article-title":"ShapeGrabber FootScanner: A Low Cost High Accuracy 3D System for the Acquisition of Human Feet","volume":"Volume 3958","author":"Blais","year":"2000","journal-title":"Three-Dimensional Image Capture and Applications III"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1117\/12.302458","article-title":"Novel fully integrated computer system for custom footwear: From 3D digitization to manufacturing","volume":"Volume 3313","author":"Houle","year":"1998","journal-title":"Three-Dimensional Image Capture and Applications"},{"key":"ref_37","first-page":"104","article-title":"Multiple structured light system for the 3D measurement of feet","volume":"Volume 3640","author":"Gaertner","year":"1999","journal-title":"Three-Dimensional Image Capture and Applications II"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1117\/12.351360","article-title":"3D-imaging laser scanner for close-range metrology","volume":"Volume 3707","author":"Wehr","year":"1999","journal-title":"Laser Radar Technology and Applications IV"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s13047-021-00461-z","article-title":"Semi-automatic measurements of foot morphological parameters from 3D plantar foot scans","volume":"14","author":"Rogati","year":"2021","journal-title":"J. Foot Ankle Res."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1117\/12.302452","article-title":"3D range optical sensor: Analysis of the measurement errors and development of procedures for their compensation","volume":"Volume 3313","author":"Carocci","year":"1998","journal-title":"Three-Dimensional Image Capture and Applications"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1518\/hfes.46.2.304.37346","article-title":"Foot Shape Modeling","volume":"6","author":"Luximon","year":"2004","journal-title":"Hum. Factors J. Hum. Factors Ergon. Soc."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1518\/001872099779591231","article-title":"Footwear cushioning: Relating objective and subjective measurements","volume":"41","author":"Goonetilleke","year":"1999","journal-title":"Hum. Factors"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1007\/BF00714999","article-title":"Swelling of the foot, its vascular volume and systemic hemoconcentration during long-term constrained sitting","volume":"55","author":"Winkel","year":"1986","journal-title":"Eur. J. Appl. Physiol. Occup. Physiol."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1186\/1757-1146-3-19","article-title":"The use of 3D surface scanning for the measurement and assessment of the human foot","volume":"3","author":"Telfer","year":"2010","journal-title":"J. Foot Ankle Res."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"574","DOI":"10.1080\/09511921003682648","article-title":"An automatic method of measuring foot girths for custom footwear using local RBF implicit surfaces","volume":"23","author":"Ding","year":"2010","journal-title":"Int. J. Comput. Integr. Manuf."},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"Goonetilleke, R.S., Witana, C.P., Zhao, J., and Xiong, S. (2009, January 19\u201324). The pluses and minuses of obtaining measurements from digital scans. Proceedings of the International Conference on Digital Human Modeling, San Diego, CA, USA.","DOI":"10.1007\/978-3-642-02809-0_72"},{"key":"ref_47","first-page":"145","article-title":"Novel Use of the Intel realsense sr300 camera for foot 3d reconstruction","volume":"20","author":"Fangchuan","year":"2020","journal-title":"Rev. De Piel. Incaltaminte"},{"key":"ref_48","unstructured":"Wang, J., Saito, H., Kimura, M., Mochimaru, M., and Kanade, T. (2005, January 13\u201316). Shape reconstruction of human foot from multi-camera images based on PCA of human shape database. Proceedings of the Fifth International Conference on 3-D Digital Imaging and Modeling (3DIM\u201905), Ottawa, ON, Canada."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"1732","DOI":"10.1093\/ietisy\/e89-d.5.1732","article-title":"Human foot reconstruction from multiple camera images with foot shape database","volume":"89","author":"Wang","year":"2006","journal-title":"IEICE Trans. Inf. Syst."},{"key":"ref_50","doi-asserted-by":"crossref","unstructured":"Amstutz, E., Teshima, T., Kimura, M., Mochimaru, M., and Saito, H. (2008, January 12\u201315). PCA based 3D shape reconstruction of human foot using multiple viewpoint cameras. Proceedings of the International Conference on Computer Vision Systems, Santorini, Greece.","DOI":"10.1007\/s11633-008-0217-6"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1007\/s00170-009-2087-7","article-title":"A computer-aided design system for foot-feature-based shoe last customization","volume":"46","author":"Xiong","year":"2010","journal-title":"Int. J. Adv. Manuf. Technol."},{"key":"ref_52","doi-asserted-by":"crossref","unstructured":"Xiong, S., Li, Y., Zhu, Y., Qian, J., and Yang, D. (2010, January 7\u201310). Foot measurements from 2D digital images. Proceedings of the IEEE International Conference on Industrial Engineering and Engineering Management (IEEM), Macao, China.","DOI":"10.1109\/IEEM.2010.5674498"},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1186\/s13640-018-0368-5","article-title":"A 3D foot shape feature parameter measurement algorithm based on Kinect2","volume":"2018","author":"Wang","year":"2018","journal-title":"EURASIP J. Image Video Process."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"084502","DOI":"10.1115\/1.4050751","article-title":"The Design and Validation of a Low-Cost Foot Measurement System","volume":"143","author":"Dickerson","year":"2021","journal-title":"J. Biomech. Eng."},{"key":"ref_55","doi-asserted-by":"crossref","unstructured":"Cheung, K.Y.W., Reth, D., Song, C., Li, Z., Li, Q., and Xu, W. (2019, January 19\u201322). BigFoot: A Mobile Solution toward Foot Parameters Extraction. Proceedings of the IEEE 16th International Conference on Wearable and Implantable Body Sensor Networks (BSN), Chicago, IL, USA.","DOI":"10.1109\/BSN.2019.8771077"},{"key":"ref_56","doi-asserted-by":"crossref","unstructured":"Bizen, H., Yoshida, M., Jimbu, M., and Kawai, Y. (2021, January 9\u201311). Virtual Shoe Fitting System that Uses Augmented Reality to Measure Feet and Try on Shoes. Proceedings of the IEEE 3rd Global Conference on Life Sciences and Technologies (LifeTech), Nara, Japan.","DOI":"10.1109\/LifeTech52111.2021.9391966"},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/j.medengphy.2021.08.001","article-title":"Foot-surface-structure analysis using a smartphone-based 3D foot scanner","volume":"95","author":"Yamashita","year":"2021","journal-title":"Med. Eng. Phys."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"S26","DOI":"10.1080\/19424280.2015.1038308","article-title":"Low-cost 3D foot scanner using a mobile app","volume":"7","author":"Parrilla","year":"2015","journal-title":"Footwear Sci."},{"key":"ref_59","doi-asserted-by":"crossref","unstructured":"Ballester, A., Pi\u00e9rola, A., Parrilla, E., Izquierdo, M., Uriel, J., N\u00e1cher, B., Ortiz, V., Gonzalez, J.C., Page, A., and Alemany, S. (2017, January 11\u201312). Fast, portable and low-cost 3D foot digitizers: Validity and reliability of measurements. Proceedings of the 8th International Conference and Exhibition on 3D Body Scanning and Processing Technologies, Montreal QC, Canada.","DOI":"10.15221\/17.218"},{"key":"ref_60","doi-asserted-by":"crossref","unstructured":"Ballester, A., Parrilla, E., Vivas, J.A., Pierola, A., Uriel, J., Puigcerver, S.A., Piqueras, P., Solve, C., Rodriguez, M., and Gonzalez, J.C. (2015, January 27\u201328). Low-cost data-driven 3D reconstruction and its applications. Proceedings of the 6th International Conferenc on 3D body Scanning Technologies, Lugano, Switzerland.","DOI":"10.15221\/15.184"},{"key":"ref_61","first-page":"45","article-title":"The reliability of a smartphone application in measuring the foot structure of cyclists during sitting and standing","volume":"14","year":"2021","journal-title":"Footwear Sci."},{"key":"ref_62","first-page":"40","article-title":"Engineering and environmental applications of laser scanner techniques","volume":"34","author":"Bornaz","year":"2002","journal-title":"Int. Arch. Photogramm. Remote Sens. Spat. Inf. Sci."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"690","DOI":"10.1109\/TPAMI.1987.4767964","article-title":"The adaptive Hough transform","volume":"PAMI-9","author":"Illingworth","year":"1987","journal-title":"IEEE Trans. Pattern Anal. Mach. Intell."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1016\/0020-0190(72)90045-2","article-title":"An efficient algorithm for determining the convex hull of a finite planar set","volume":"1","author":"Graham","year":"1972","journal-title":"Inf. Process. Lett."},{"key":"ref_65","doi-asserted-by":"crossref","unstructured":"Berg, M.D., Kreveld, M.v., Overmars, M., and Schwarzkopf, O. (1997). Computational geometry. Computational Geometry, Springer.","DOI":"10.1007\/978-3-662-03427-9_1"},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/0146-664X(80)90054-4","article-title":"Euclidean distance mapping","volume":"14","author":"Danielsson","year":"1980","journal-title":"Comput. Graph. Image Process."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/j.cie.2007.07.015","article-title":"Computerized girth determination for custom footwear manufacture","volume":"54","author":"Zhao","year":"2008","journal-title":"Comput. Ind. Eng."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/23\/9554\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T01:35:11Z","timestamp":1760146511000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/23\/9554"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,6]]},"references-count":67,"journal-issue":{"issue":"23","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["s22239554"],"URL":"https:\/\/doi.org\/10.3390\/s22239554","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,12,6]]}}}