{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T17:11:06Z","timestamp":1792602666998,"version":"4.5.0"},"reference-count":19,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2022,12,20]],"date-time":"2022-12-20T00:00:00Z","timestamp":1671494400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Quartz Crystal Microbalances (QCM) are widely used instruments thanks to their stability, low mass, and low cost. Nevertheless, the sensitivity to temperature is their main drawback and is often a driver for their design. Though the crystal average temperature is mostly considered as the only disturbance, temperature affects the QCM measurements also through the in-plane temperature gradients, an effect identified in the past but mostly neglected. Recently, it has been shown that this effect can prevail over that of the average temperature in implementations where the heat for thermal control is released directly on the crystal through deposited film heaters. In this study, the effect of temperature gradients for this kind of crystal is analyzed, the sensitivity of frequency to the average temperature gradient on the electrode border is determined, and a correction is proposed and verified. A numerical thermal model of the QCM has been created to determine the temperature gradients on the electrode borders. The frequency versus temperature-gradient function has been experimentally determined in different thermal conditions. The correction function has been eventually applied to a QCM implementing a crystal of the same manufacturing lot as the one used for the characterization. The residual errors after the implementation of the correction of both average temperature and temperature gradients were always lower than 5% of the initial temperature disturbance. Moreover, using the correlation between the heater power dissipation and the generated temperature gradients, it has been shown that an effective correction strategy can be based on the measurement of the power delivered to the crystal without the determination of the temperature gradient.<\/jats:p>","DOI":"10.3390\/s23010024","type":"journal-article","created":{"date-parts":[[2022,12,21]],"date-time":"2022-12-21T02:04:21Z","timestamp":1671588261000},"page":"24","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Compensation of Thermal Gradients Effects on a Quartz Crystal Microbalance"],"prefix":"10.3390","volume":"23","author":[{"given":"Marianna","family":"Magni","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering Politecnico di Milano, Polo Territoriale di Lecco, Via G. Previati 1\/c, 23900 Lecco, Italy"},{"name":"Rebel Dynamics, Via Carlo Porta 38, Cesana Brianza, 23861 Lecco, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3089-8942","authenticated-orcid":false,"given":"Diego","family":"Scaccabarozzi","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering Politecnico di Milano, Polo Territoriale di Lecco, Via G. Previati 1\/c, 23900 Lecco, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4033-3585","authenticated-orcid":false,"given":"Bortolino","family":"Saggin","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering Politecnico di Milano, Polo Territoriale di Lecco, Via G. Previati 1\/c, 23900 Lecco, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,12,20]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Wallace, D.A., and Wallace, S.A. (1988, January 27\u201329). Realistic performance specifications for flight quartz crystal microbalance instruments for contamination measurement on spacecraft. Proceedings of the AIAA 23rd Thermophysics, Plasmadynamics and Lasers Conference, San Antonio, CA, USA.","DOI":"10.2514\/6.1988-2727"},{"key":"ref_2","unstructured":"Wallace, D.A. (1980, January 5\u20137). Performance of a flight qualified, thermoelectrically temperature controlled QCM sensor with power supply, thermal controller and signal processor. Proceedings of the NASA Conference Publication, Hampton, VI, USA."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"31343","DOI":"10.1021\/acsami.2c08434","article-title":"Guar Gum\/Ethyl Cellulose-Polyvinyl Pyrrolidone Composite-Based Quartz Crystal Microbalance Humidity Sensor for Human Respiration Monitoring","volume":"14","author":"Yan","year":"2022","journal-title":"ACS Appl. Mater. Interfaces"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"SG1021","DOI":"10.35848\/1347-4065\/ac4141","article-title":"Measurement of complex shear viscosity up to 3 GHz using an electrodeless AT-cut quartz transducer","volume":"61","author":"Yamaguchi","year":"2022","journal-title":"Jpn. J. Appl. Phys."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"113498","DOI":"10.1016\/j.sna.2022.113498","article-title":"The potential of acoustic wave devices for gas sensing applications","volume":"339","author":"Kumar","year":"2022","journal-title":"Sens. Actuators A Phys."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"131419","DOI":"10.1016\/j.snb.2022.131419","article-title":"Highly sensitive ammonia sensor based on PSS doped ZIF-8-derived porous carbon\/polyaniline hybrid film coated on quartz crystal microbalance","volume":"357","author":"Zhang","year":"2022","journal-title":"Sens. Actuators B Chem."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Johnson, W.L., and Mansfield, E. (2012, January 21\u201324). Thermogravimetric analysis with a heated quartz crystal microbalance. Proceedings of the 2012 IEEE International Frequency Control Symposium Proceedings (IFCS 2012), Baltimore, MD, USA.","DOI":"10.1109\/FCS.2012.6243694"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Dirri, F., Palomba, E., Longobardo, A., Biondi, D., Boccaccini, A., Galiano, A., Zampetti, E., Saggin, B., Scaccabarozzi, D., and Martin-Torres, J. (2018, January 20\u201322). VISTA Instrument: A PCM-Based sensor for organics and volatiles characterization by using thermogravimetric technique. Proceedings of the 5th IEEE International Workshop on Metrology for AeroSpace, MetroAeroSpace 2018-Proceedings, Rome, Italy.","DOI":"10.1109\/MetroAeroSpace.2018.8453532"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1002\/j.1538-7305.1940.tb03132.x","article-title":"Low Temperature Coefficient Quartz Crystals","volume":"19","author":"Mason","year":"1940","journal-title":"Bell Labs Tech. J."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1109\/JRPROC.1944.230340","article-title":"Low-Frequency Quartz-Crystal Cuts Having Low Temperature Coefficients","volume":"32","author":"Mason","year":"1944","journal-title":"Proc. IRE"},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Tsuchiya, Y., Kukita, H., Shiobara, T., Yukumatsu, K., and Miyazaki, E. (2019, January 27\u201330). Temperature Controllable QCM Sensor with Accurate Temperature Measurement for Outgas and Contamination Assessment. Proceedings of the IEEE Sensors, Montreal, QC, Canada.","DOI":"10.1109\/SENSORS43011.2019.8956952"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"2386","DOI":"10.1016\/j.asr.2014.08.030","article-title":"Thermo-mechanical design and testing of a microbalance for space applications","volume":"54","author":"Scaccabarozzi","year":"2014","journal-title":"Adv. Space Res."},{"key":"ref_13","unstructured":"Valentin, J.P., Theobald, G., and Gagnepain, J.J. (June, January 29). Frequency Shifts Arising from in-Plane Temperature Gradient Distribution in Quartz Resonators. Proceedings of the Annual IEEE International Frequency Control Symposium, Philadelphia, PA, USA."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1388","DOI":"10.1063\/1.336112","article-title":"Temperature-induced frequency shifts in quartz resonators","volume":"58","author":"Valentin","year":"1985","journal-title":"J. Appl. Phys."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1109\/T-SU.1985.31634","article-title":"On the Interaction of Temperature Gradients with Surface Wave Propagation in Anisotropic Solids","volume":"32","author":"Sinha","year":"1985","journal-title":"IEEE Trans. Sonics Ultrason."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"5715","DOI":"10.1109\/JSEN.2018.2840124","article-title":"A QCM Dew Point Sensor With Active Temperature Control Using Thermally Conductive Electrodes","volume":"18","author":"Li","year":"2018","journal-title":"IEEE Sens. J."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Magni, M., Scaccabarozzi, D., Palomba, E., Zampetti, E., and Saggin, B. (2022). Characterization of Thermal Gradient Effects on a Quartz Crystal Microbalance. Sensors, 22.","DOI":"10.3390\/s22197256"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/j.tecto.2008.11.006","article-title":"Effect of crystal preferred orientations on the thermal diffusivity of quartz polycrystalline aggregates at high temperature","volume":"465","author":"Gibert","year":"2009","journal-title":"Tectonophysics"},{"key":"ref_19","unstructured":"Rohsenow, W.R., Hartnett, J.P., and Cho, Y.I. (1998). Handbook of Heat Transfer, McGraw Hill."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/1\/24\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T01:44:45Z","timestamp":1760147085000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/1\/24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,20]]},"references-count":19,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,1]]}},"alternative-id":["s23010024"],"URL":"https:\/\/doi.org\/10.3390\/s23010024","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,12,20]]}}}