{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,23]],"date-time":"2025-12-23T19:01:32Z","timestamp":1766516492719,"version":"build-2065373602"},"reference-count":26,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2022,12,20]],"date-time":"2022-12-20T00:00:00Z","timestamp":1671494400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"NASA MatISSE program"},{"name":"NASA Postdoctoral Program at the Jet Propulsion Laboratory"},{"name":"USRA under contract with NASA"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Since its invention in 1955, the Galperin symmetric triaxial seismometer has been widely used for seismic detection on Earth, and most recently on the planet Mars. In this paper, we present detailed physics of such seismometers, which has not yet been published in open literature. We extended Galperin\u2019s original work, which is based on idealized geometry and assumptions, to include more practical cases, including (1) non-idealized tilt angles of its component seismometers; (2) component seismometers that are not exactly oriented 120\u00b0 apart; (3) distributed mass on the boom; and (4) the case of operations at lower frequencies.<\/jats:p>","DOI":"10.3390\/s23010026","type":"journal-article","created":{"date-parts":[[2022,12,21]],"date-time":"2022-12-21T02:04:21Z","timestamp":1671588261000},"page":"26","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Extensions of the Galperin Transformation Matrices for Triaxial Seismometers"],"prefix":"10.3390","volume":"23","author":[{"given":"Talso C. P.","family":"Chui","sequence":"first","affiliation":[{"name":"Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9587-8670","authenticated-orcid":false,"given":"Andrew","family":"Erwin","sequence":"additional","affiliation":[{"name":"Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Inseob","family":"Hahn","sequence":"additional","affiliation":[{"name":"Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2022,12,20]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1289","DOI":"10.1785\/0120110223","article-title":"Review: Inertial sensors for low-frequency seismic vibration measurement","volume":"102","author":"Collette","year":"2012","journal-title":"Bull. Seismol. Soc. Am."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"945","DOI":"10.1785\/0120080344","article-title":"Introduction to the special issue on rotational seismology and engineering applications","volume":"99","author":"Lee","year":"2009","journal-title":"Bull. Seismol. Soc. Am."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"2049","DOI":"10.1785\/BSSA0660062049","article-title":"The seismic research observatory","volume":"66","author":"Peterson","year":"1976","journal-title":"Bull. Seismol. Soc. Am."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1126\/science.165.3890.241","article-title":"The Apollo Passive Seismic Experiment","volume":"165","author":"Latham","year":"1969","journal-title":"Science"},{"key":"ref_5","first-page":"2349","article-title":"The leaf-spring seismometer: Design and performance","volume":"72","author":"Wielandt","year":"1982","journal-title":"Bull. Seismol. Soc. Am."},{"unstructured":"Galperin, E.I. (1955). Azimuthal Method of Seismic Observations, Gostoptechizdat.","key":"ref_6"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1366","DOI":"10.1785\/0120080174","article-title":"The response to complex ground motions of seismometers with Galperin sensor configuration","volume":"99","author":"Graizer","year":"2009","journal-title":"Bull. Seismol. Soc. Am."},{"unstructured":"Bormann, P. (2002). Seismic sensors and their calibration. New Manual of Seismological Observatory Practice (NMSOP), IASPEI, GFZ.","key":"ref_8"},{"doi-asserted-by":"crossref","unstructured":"Beer, M., Kougioumtzoglou, I., Patelli, E., and Au, I.K. (2014). Symmetric triaxial seismometers. Encyclopedia of Earthquake Engineering, Springer.","key":"ref_9","DOI":"10.1007\/978-3-642-36197-5"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"3434","DOI":"10.4028\/www.scientific.net\/AMM.644-650.3434","article-title":"Application of digital coordinate transformation to a new posthole broadband seismometer","volume":"644\u2013650","author":"Peng","year":"2014","journal-title":"Appl. Mech. Mater."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"972","DOI":"10.1785\/gssrl.81.6.972","article-title":"Self-noise models of seismic instruments","volume":"81","author":"Ringler","year":"2010","journal-title":"Seismol. Res. Lett."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1785\/0120170233","article-title":"Effects of thermal variability on broadband seismometers: Controlled experiments, observations, and implications","volume":"108","author":"Doody","year":"2018","journal-title":"Bull. Seismol. Soc. Am."},{"unstructured":"Streckeisen, G., and Messger\u00e4te, A.G. (1995). Portable Very-Broad-Band Tri-Axial Seismometer, STS-2, Manual, Streckeosen AG.","key":"ref_13"},{"unstructured":"Nanometrics Inc. (2021). Trillium Compact, Datasheet, Nanometrics, Inc.","key":"ref_14"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"36","DOI":"10.3847\/PSJ\/abd63b","article-title":"Standing on Apollo\u2019s shoulders: A microseismometer for the Moon","volume":"2","author":"Nunn","year":"2021","journal-title":"Planet. Sci. J."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1093\/gji\/ggz473","article-title":"Improvements in seismic resolution and current limitations in the Global Seismographic Network","volume":"220","author":"Ringler","year":"2020","journal-title":"Geophys. J. Int."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"2022","DOI":"10.1785\/0120180045","article-title":"Three-component borehole optical seismic geodetic sensor","volume":"108","author":"Zumberge","year":"2018","journal-title":"Bull. Seismol. Soc. Am."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1038\/s41561-020-0536-y","article-title":"Constraints on the shallow elastic and anelastic structure of Mars from InSight seismic data","volume":"13","author":"Banerdt","year":"2020","journal-title":"Nat. Geosci."},{"key":"ref_19","first-page":"1","article-title":"SEIS: InSight\u2019s seismic experiment for internal structure of Mars","volume":"215","author":"Banerdt","year":"2019","journal-title":"Space Sci. Rev."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2102","DOI":"10.1063\/1.1144819","article-title":"A method for measuring the dependence of internal friction on strain","volume":"65","author":"Huang","year":"1994","journal-title":"Rev. Sci. Instrum."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"3065","DOI":"10.1785\/0120210072","article-title":"Brownian Noise and Temperature Sensitivity of Long-Period Lunar Seismometers","volume":"111","author":"Erwin","year":"2021","journal-title":"Bull. Seismol. Soc. Am."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1007\/s11214-017-0409-x","article-title":"The noise model of the SEIS seismometer of the InSight mission to Mars","volume":"211","author":"Mimoun","year":"2017","journal-title":"Space Sci. Rev."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"015101","DOI":"10.1063\/5.0019351","article-title":"Electrostatic frequency reduction: A negative stiffness mechanism for measuring dissipation in a mechanical oscillator at low frequency","volume":"92","author":"Erwin","year":"2021","journal-title":"Rev. Sci. Instrum."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1016\/S0375-9601(99)00597-6","article-title":"Electrostatic damping and its effect on precision mechanical experiments","volume":"263","author":"Speake","year":"1999","journal-title":"Phys. Lett. A"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1016\/S0375-9601(99)00184-X","article-title":"Low-frequency internal friction in clamped-free thin wires","volume":"255","author":"Cagnoli","year":"1999","journal-title":"Phys. Lett. A"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s11214-020-00709-3","article-title":"Lunar seismology: A data and instrumentation review","volume":"216","author":"Nunn","year":"2020","journal-title":"Space Sci. Rev."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/1\/26\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T01:44:45Z","timestamp":1760147085000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/1\/26"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,20]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,1]]}},"alternative-id":["s23010026"],"URL":"https:\/\/doi.org\/10.3390\/s23010026","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2022,12,20]]}}}