{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,30]],"date-time":"2025-12-30T08:58:44Z","timestamp":1767085124063,"version":"build-2065373602"},"reference-count":40,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2022,12,21]],"date-time":"2022-12-21T00:00:00Z","timestamp":1671580800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This paper presents a novel hallway gait extraction system that enables an individual\u2019s spatiotemporal gait parameter extraction at each gait cycle using a single FMCW (Frequency Modulated Continuous Wave) radar. The purpose of the proposed system is to detect changes in gait that may be the signs of changes in mobility, cognition, and frailty, particularly for older adults in retirement homes. We believe that one of the straightforward applications for gait monitoring using radars is in corridors and hallways, which are commonly available in most retirement and long-term care homes. To achieve in-corridor coverage, we designed an in-package hyperbola-based lens antenna integrated with a radar module package empowered by our fast and easy-to-implement gait extraction method. We validated system functionality by capturing spatiotemporal gait values (e.g., speed, step points, step time, step length, and step count) of people walking in a hallway. The results achieved in this work pave the way to explore the use of stand-alone radar-based sensors in long hallways in retirement apartment buildings or individual\u2019s homes for use in day-to-day long-term monitoring of gait parameters of older adults.<\/jats:p>","DOI":"10.3390\/s23010071","type":"journal-article","created":{"date-parts":[[2022,12,22]],"date-time":"2022-12-22T02:31:11Z","timestamp":1671676271000},"page":"71","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Hallway Gait Monitoring System Using an In-Package Integrated Dielectric Lens Paired with a mm-Wave Radar"],"prefix":"10.3390","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4089-0373","authenticated-orcid":false,"given":"Hajar","family":"Abedi","sequence":"first","affiliation":[{"name":"Department of Systems Design Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6150-151X","authenticated-orcid":false,"given":"Jennifer","family":"Boger","sequence":"additional","affiliation":[{"name":"Department of Systems Design Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9515-6478","authenticated-orcid":false,"given":"Plinio Pelegrini","family":"Morita","sequence":"additional","affiliation":[{"name":"School of Public Health Sciences, University of Waterloo, Waterloo, ON N2L 3G1, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexander","family":"Wong","sequence":"additional","affiliation":[{"name":"Department of Systems Design Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1450-2138","authenticated-orcid":false,"given":"George","family":"Shaker","sequence":"additional","affiliation":[{"name":"Electrical and Computer Engineering Department, University of Waterloo, Waterloo, ON N2L 3G1, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2022,12,21]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"2186","DOI":"10.1109\/TMC.2020.2975158","article-title":"GaitWay: Monitoring and Recognizing Gait Speed Through the Walls","volume":"20","author":"Wu","year":"2021","journal-title":"IEEE Trans. Mob. Comput."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1109\/TBME.2004.840727","article-title":"Assessment of Walking Features from Foot Inertial Sensing","volume":"52","author":"Sabatini","year":"2005","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_3","first-page":"353","article-title":"Gait Analysis: Normal and Pathological Function","volume":"9","author":"Perry","year":"2010","journal-title":"J. Sport. Sci. Med."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1016\/j.gaitpost.2004.10.005","article-title":"Validity of the GAITRite\u00ae walkway system for the measurement of averaged and individual step parameters of gait","volume":"22","author":"Webster","year":"2005","journal-title":"Gait Posture"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"274","DOI":"10.3109\/03091902.2014.909540","article-title":"Comparative abilities of Microsoft Kinect and Vicon 3D motion capture for gait analysis","volume":"38","author":"Pfister","year":"2014","journal-title":"J. Med. Eng. Technol."},{"key":"ref_6","first-page":"84","article-title":"Falls in an acute care hospital as reported in the adverse event management system","volume":"4","author":"Watson","year":"2015","journal-title":"J. Hosp. Adm."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Diraco, G., Leone, A., and Siciliano, P. (2017). A Radar-Based Smart Sensor for Unobtrusive Elderly Monitoring in Ambient Assisted Living Applications. Biosensors, 7.","DOI":"10.20944\/preprints201710.0115.v1"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Postolache, O., Pereira, J.D., Viegas, V., and Girao, P.S. (2015, January 7\u20139). Gait Rehabilitation Assessment Based on Microwave Doppler Radars Embedded in Walkers. Proceedings of the 2015 IEEE International Symposium on Medical Measurements and Applications, MeMeA 2015\u2014Proceedings, Torino, Italy.","DOI":"10.1109\/MeMeA.2015.7145200"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Alshamaa, D., Chkeir, A., Soubra, R., and Mourad-Chehade, F. (2019, January 11\u201313). Measurement of Gait Speed using a Doppler Radar: Influence of Acceleration and Deceleration Zones. Proceedings of the SAS 2019\u20142019 IEEE Sensors Applications Symposium, Sophia Antipolis, France.","DOI":"10.1109\/SAS.2019.8706123"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Tahmoush, D., and Silvious, J. (2009, January 28\u201330). Radar Micro-Doppler for Long range Front-View Gait Recognition. Proceedings of the IEEE 3rd International Conference on Biometrics: Theory, Applications and Systems (BTAS 2009), Washington, DC, USA.","DOI":"10.1109\/BTAS.2009.5339049"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"15133","DOI":"10.1109\/JSEN.2022.3184188","article-title":"Hallway Gait Monitoring Using Novel Radar Signal Processing and Unsupervised Learning","volume":"22","author":"Abedi","year":"2022","journal-title":"IEEE Sens. J."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"23","DOI":"10.2478\/v10177-011-0003-1","article-title":"Gait Variations in Human Micro-Doppler","volume":"57","author":"Tahmoush","year":"2011","journal-title":"Int. J. Electron. Telecommun."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Yardibi, T., Cuddihy, P., Genc, S., Bufi, C., Skubic, M., Rantz, M., Liu, L., and Phillips, C. (2011, January 21\u201325). Gait Characterization via Pulse-Doppler Radar. Proceedings of the 2011 IEEE International Conference on Pervasive Computing and Communications Workshops (PERCOM Workshops 2011), Seattle, WA, USA.","DOI":"10.1109\/PERCOMW.2011.5766971"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Seifert, A.K., Amin, M.G., and Zoubir, A.M. (2019, January 22\u201326). Detection of Gait Asymmetry using Indoor Doppler Radar. Proceedings of the 2019 IEEE Radar Conference (RadarConf), Boston, MA, USA.","DOI":"10.1109\/RADAR.2019.8835611"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Fei, L., Binke, H., Hang, Z., and Hao, D. (2012, January 27\u201330). Human Gait Recognition using Micro-Doppler Features. Proceedings of the 2012 5th Global Symposium on Millimeter-Waves (GSMM 2012), Harbin, China.","DOI":"10.1109\/GSMM.2012.6314067"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Palmer, J.W., Bing, K.F., Sharma, A.C., and Perkins, J.B. (2012, January 4\u20137). Exploitation of Radar Doppler Signatures for Gait Analysis. Proceedings of the 2012 Conference Record of the Forty Sixth Asilomar Conference on Signals, Systems and Computers (ASILOMAR), Pacific Grove, CA, USA.","DOI":"10.1109\/ACSSC.2012.6489085"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"2125","DOI":"10.1109\/LGRS.2015.2452311","article-title":"Knowledge Exploitation for Human Micro-Doppler Classification","volume":"12","author":"Karabacak","year":"2015","journal-title":"IEEE Geosci. Remote Sens. Lett."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Boutte, D., Radzicki, V.R., Gumley, M., Hunt, S., Taylor, P., and Hunt, A. (2017, January 8\u201312). A Multistatic Doppler Radar System with Application to Aeroecology. Proceedings of the 2017 IEEE Radar Conference (RadarConf 2017), Seattle, WA, USA.","DOI":"10.1109\/RADAR.2017.7944169"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1109\/JBHI.2020.2994471","article-title":"Doppler Radar for the Extraction of Biomechanical Parameters in Gait Analysis","volume":"25","author":"Seifert","year":"2021","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Abedi, H., Ansariyan, A., Morita, P.P., Boger, J., Wong, A., and Shaker, G. (2021, January 4\u201310). Sequential Deep Learning for In-Home Activity Monitoring Using mm-Wave FMCW Radar. Proceedings of the 2021 IEEE International Symposium on Antennas and Propagation and North American Radio Science Meeting, APS\/URSI 2021\u2014Proceedings, Singapore.","DOI":"10.1109\/APS\/URSI47566.2021.9704291"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Abedi, H., Ansariyan, A., Morita, P.P., Wong, A., Boger, J., and Shaker, G. (2022). AI-Powered Non-Contact In-Home Gait Monitoring and Activity Recognition System Based on mm-Wave FMCW Radar and Cloud Computing. arXiv.","DOI":"10.1109\/JIOT.2023.3235268"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Abedi, H., Morita, P.P., Boger, J., Wong, A., and Shaker, G. (2021, January 4\u201310). In-Package Integrated Dielectric Lens Paired with a MIMO mm-Wave Radar for Corridor Gait Monitoring. Proceedings of the 2021 IEEE International Symposium on Antennas and Propagation and North American Radio Science Meeting, APS\/URSI 2021\u2014Proceedings, Singapore.","DOI":"10.1109\/APS\/URSI47566.2021.9704192"},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Abedi, H., and Shaker, G. (2020, January 5\u201310). Low-Cost 3D printed Dielectric Hyperbolic Lens Antenna for Beam Focusing and Steering of a 79 GHz MIMO Radar. Proceedings of the 2020 IEEE International Symposium on Antennas and Propagation and North American Radio Science Meeting, IEEECONF 2020\u2014Proceedings, Quebec, QC, Canada.","DOI":"10.1109\/IEEECONF35879.2020.9329969"},{"key":"ref_24","first-page":"2","article-title":"Integration of Random Forests and MM-Wave FMCW Radar Technology for Gait Recognition","volume":"5","author":"Abedi","year":"2019","journal-title":"J. Comput. Vis. Imaging Syst."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Abedi, H., Ansariyan, A., Lehman, C., Morita, P.P., Boger, J., Wong, A., and Shaker, G. (November, January 30). Non-Visual and Contactless Wellness Monitoring for Long Term Care Facilities Using mm-Wave Radar Sensors. Proceedings of the 2022 IEEE Sensors, Dallas, TX, USA.","DOI":"10.1109\/SENSORS52175.2022.9967327"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"2019","DOI":"10.34297\/AJBSR.2019.06.001009","article-title":"Use of Millimeter Wave FMCW Radar to Capture Gait Parameters","volume":"6","author":"Abedi","year":"2019","journal-title":"Am. J. Biomed. Sci. Res."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Fernandes, C.A., Lima, E.B., and Costa, J.R. (2015). Dielectric Lens Antennas, Springer Science+Business Media.","DOI":"10.1007\/978-981-4560-75-7_40-1"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"18998","DOI":"10.1109\/ACCESS.2021.3138051","article-title":"AI-Powered In-Vehicle Passenger Monitoring Using Low-Cost mm-Wave Radar","volume":"10","author":"Abedi","year":"2021","journal-title":"IEEE Access"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"38809","DOI":"10.1109\/ACCESS.2020.2975805","article-title":"WGM-Based Sensing of Characterized Glucose- Aqueous Solutions at mm-Waves","volume":"8","author":"Omer","year":"2020","journal-title":"IEEE Access"},{"key":"ref_30","unstructured":"(2019, February 20). Ansys HFSS | 3D High-Frequency Simulation Software. Available online: https:\/\/www.ansys.com\/products\/electronics\/ansys-hfss."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"276","DOI":"10.4266\/acc.2019.00647","article-title":"Lund and Browder chart\u2014Modified versus original: A comparative study","volume":"34","author":"Murari","year":"2019","journal-title":"Acute Crit. Care"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1047","DOI":"10.3390\/ijerph7031047","article-title":"Leg Length, Body Proportion, and Health: A Review with a Note on Beauty","volume":"7","author":"Bogin","year":"2010","journal-title":"Int. J. Environ. Res. Public Health"},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Seifert, A.-K., Zoubir, A.M., and Amin, M.G. (2017, January 8\u201312). Radar-Based Human Gait Recognition in Cane-Assisted Walks. Proceedings of the 2017 IEEE Radar Conference (RadarConf 2017), Seattle, WA, USA.","DOI":"10.1109\/RADAR.2017.7944431"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1109\/TAES.2006.1603402","article-title":"Micro-doppler effect in radar: Phenomenon, model, and simulation study","volume":"42","author":"Chen","year":"2006","journal-title":"IEEE Trans. Aerosp. Electron. Syst."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1007\/s41666-020-00071-7","article-title":"Comparative Analysis of Gait Speed Estimation Using Wideband and Narrowband Radars, Thermal Camera, and Motion Tracking Suit Technologies","volume":"4","author":"Morita","year":"2020","journal-title":"J. Healthc. Inform. Res."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1111\/j.1532-5415.2006.00701.x","article-title":"Meaningful Change and Respon-siveness in Common Physical Performance Measures in Older Adults","volume":"54","author":"Perera","year":"2006","journal-title":"J. Am. Geriatr. Soc."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"2320","DOI":"10.1109\/JSEN.2017.2678484","article-title":"Gait Classification of Young Adults, Elderly Non-Fallers, and Elderly Fallers Using Micro-Doppler Radar Signals: Simulation Study","volume":"17","author":"Saho","year":"2017","journal-title":"IEEE Sens. J."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"24122","DOI":"10.1109\/ACCESS.2019.2900303","article-title":"Using Micro-Doppler Radar to Measure Gait Features Associated with Cognitive Functions in Elderly Adults","volume":"7","author":"KSaho","year":"2019","journal-title":"IEEE Access"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"2434","DOI":"10.1109\/TBME.2014.2319333","article-title":"Quantitative Gait Measurement with Pulse-Doppler Radar for Passive In-Home Gait Assessment","volume":"61","author":"Wang","year":"2014","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Morita, P.P., Rocha, A.S., Shaker, G., Lee, D., Wei, J., Fong, B., Thatte, A., Karimi, A.-H., Xu, L.L., and Ma, A. (2019, January 24\u201327). Comparison of Gait Speed Estimation of Multiple Sensor-Based Technologie. Proceedings of the International Symposium on Human Factors and Ergonomics in Health Care, Chicago, IL, USA.","DOI":"10.1177\/2327857919081032"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/1\/71\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T01:47:06Z","timestamp":1760147226000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/1\/71"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,21]]},"references-count":40,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,1]]}},"alternative-id":["s23010071"],"URL":"https:\/\/doi.org\/10.3390\/s23010071","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2022,12,21]]}}}