{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,11]],"date-time":"2026-04-11T06:09:26Z","timestamp":1775887766795,"version":"3.50.1"},"reference-count":36,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2022,12,28]],"date-time":"2022-12-28T00:00:00Z","timestamp":1672185600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institute of Health","doi-asserted-by":"publisher","award":["RF1-NS113285"],"award-info":[{"award-number":["RF1-NS113285"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000002","name":"National Institute of Health","doi-asserted-by":"publisher","award":["R01-EB025149"],"award-info":[{"award-number":["R01-EB025149"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>We present a rapid prototyping method for sub-megahertz single-element piezoelectric transducers by using 3D-printed components. In most of the early research phases of applying new sonication ideas, the prototyping quickness is prioritized over the final packaging quality, since the quickness of preliminary demonstration is crucial for promptly determining specific aims and feasible research approaches. We aim to develop a rapid prototyping method for functional ultrasonic transducers to overcome the current long lead time (&gt;a few weeks). Here, we used 3D-printed external housing parts considering a single matching layer and either air backing or epoxy-composite backing (acoustic impedance &gt; 5 MRayl). By molding a single matching layer on the top surface of a piezoceramic in a 3D-printed housing, an entire packaging time was significantly reduced (&lt;26 h) compared to the conventional methods with grinding, stacking, and bonding. We demonstrated this prototyping method for 590-kHz single-element, rectangular-aperture transducers for moderate pressure amplitudes (mechanical index &gt; 1) at focus with temporal pulse controllability (maximum amplitude by &lt;5-cycle burst). We adopted an air-backing design (Type A) for efficient pressure outputs, and bandwidth improvement was tested by a tungsten-composite-backing (Type B) design. The acoustic characterization results showed that the type A prototype provided 3.3 kPa\/Vpp far-field transmitting sensitivity with 25.3% fractional bandwidth whereas the type B transducer showed 2.1 kPa\/Vpp transmitting sensitivity with 43.3% fractional bandwidth. As this method provided discernable quickness and cost efficiency, this detailed rapid prototyping guideline can be useful for early-phase sonication projects, such as multi-element therapeutic ultrasound array and micro\/nanomedicine testing benchtop device prototyping.<\/jats:p>","DOI":"10.3390\/s23010313","type":"journal-article","created":{"date-parts":[[2022,12,28]],"date-time":"2022-12-28T05:38:43Z","timestamp":1672205923000},"page":"313","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["A Rapid Prototyping Method for Sub-MHz Single-Element Piezoelectric Transducers by Using 3D-Printed Components"],"prefix":"10.3390","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2072-3922","authenticated-orcid":false,"given":"Jinwook","family":"Kim","sequence":"first","affiliation":[{"name":"Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC 27599, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bryce","family":"Menichella","sequence":"additional","affiliation":[{"name":"Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC 27599, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hanjoo","family":"Lee","sequence":"additional","affiliation":[{"name":"Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC 27599, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul A.","family":"Dayton","sequence":"additional","affiliation":[{"name":"Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC 27599, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gianmarco F.","family":"Pinton","sequence":"additional","affiliation":[{"name":"Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC 27599, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2022,12,28]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Safari, A., and Akdogan, E.K. (2008). Piezoelectric Transducers and Acoustic Materials for Transducer Aplications, Springer Science & Business Media.","DOI":"10.1007\/978-0-387-76540-2"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/j.pmatsci.2014.06.001","article-title":"Piezoelectric Single Crystal Ultrasonic Transducers for Biomedical Applications","volume":"66","author":"Zhou","year":"2014","journal-title":"Prog. Mater. Sci."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Hoskins, P., Martin, K., and Thrush, A. (2010). Diagnostic Ultrasound: Physics and Equipment, Cambridge University Press. [2nd ed.].","DOI":"10.1017\/CBO9780511750885"},{"key":"ref_4","unstructured":"Gallego-Ju\u00e1rez, J.A., and Graff, K.F. (2015). High-Intensity Focused Ultrasound for Medical Therapy. Power Ultrasonics, Woodhead Publishing."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Jiang, X., Li, S., Kim, J., and Ma, J. (2017). High Frequency Piezo-Composite Micromachined Ultrasound Transducer Array Technology for Biomedical Imaging, ASME Press.","DOI":"10.1115\/1.860441"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"3515","DOI":"10.1088\/0031-9155\/49\/16\/001","article-title":"A New Ultrasonic Transducer for Improved Contrast Nonlinear Imaging","volume":"49","author":"Bouakaz","year":"2004","journal-title":"Phys. Med. Biol."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Dauba, A., Delalande, A., Kamimura, H.A.S., Conti, A., Larrat, B., Tsapis, N., and Novell, A. (2020). Recent Advances on Ultrasound Contrast Agents for Blood-Brain Barrier Opening with Focused Ultrasound. Pharmaceutics, 12.","DOI":"10.3390\/pharmaceutics12111125"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1038\/nmat3776","article-title":"Stimuli-Responsive Nanocarriers for Drug Delivery","volume":"12","author":"Mura","year":"2013","journal-title":"Nat. Mater."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"9480193","DOI":"10.1155\/2019\/9480193","article-title":"Review on Acoustic Droplet Vaporization in Ultrasound Diagnostics and Therapeutics","volume":"2019","author":"Loskutova","year":"2019","journal-title":"Biomed. Res. Int."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"10973","DOI":"10.7150\/thno.49670","article-title":"Ultrasound-Triggered Therapeutic Microbubbles Enhance the Efficacy of Cytotoxic Drugs by Increasing Circulation and Tumor Drug Accumulation and Limiting Bioavailability and Toxicity in Normal Tissues","volume":"10","author":"Ingram","year":"2020","journal-title":"Theranostics"},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Sung, J.-H., and Chang, J.-H. (2021). Mechanically Rotating Intravascular Ultrasound (IVUS) Transducer: A Review. Sensors, 21.","DOI":"10.3390\/s21113907"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"2917","DOI":"10.1109\/TUFFC.2021.3068113","article-title":"Transcranial MR-Guided Histotripsy System","volume":"68","author":"Lu","year":"2021","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"2419","DOI":"10.1109\/TUFFC.2021.3065952","article-title":"Characterization of an Array-Based Dual-Frequency Transducer for Superharmonic Contrast Imaging","volume":"68","author":"Yang","year":"2021","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1007\/s10557-020-07016-7","article-title":"Ultrasound Theranostics in Adult and Pediatric Cardiovascular Research","volume":"35","author":"Jani","year":"2021","journal-title":"Cardiovasc. Drugs Ther."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"2418","DOI":"10.1109\/TUFFC.2018.2872911","article-title":"A Dual-Frequency Co-Linear Array for Acoustic Angiography in Prostate Cancer Evaluation","volume":"65","author":"Li","year":"2018","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1073\/pnas.1910343117","article-title":"Biodegradable Nanofiber-Based Piezoelectric Transducer","volume":"117","author":"Curry","year":"2020","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1585","DOI":"10.1038\/s41467-022-29065-2","article-title":"Ultrasound-Controllable Engineered Bacteria for Cancer Immunotherapy","volume":"13","author":"Abedi","year":"2022","journal-title":"Nat. Commun."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"2131","DOI":"10.1109\/TUFFC.2018.2869689","article-title":"A Low-Cost Miniature Histotripsy Transducer for Precision Tissue Ablation","volume":"65","author":"Woodacre","year":"2018","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"106520","DOI":"10.1016\/j.ultras.2021.106520","article-title":"A Multi-Pillar Piezoelectric Stack Transducer for Nanodroplet Mediated Intravascular Sonothrombolysis","volume":"116","author":"Kim","year":"2021","journal-title":"Ultrasonics"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1559","DOI":"10.1109\/TUFFC.2014.3070","article-title":"Rapid Prototyping Fabrication of Focused Ultrasound Transducers","volume":"61","author":"Kim","year":"2014","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Zhu, K., Ma, J., Qi, X., Shen, B., Liu, Y., Sun, E., and Zhang, R. (2022). Enhancement of Ultrasonic Transducer Bandwidth by Acoustic Impedance Gradient Matching Layer. Sensors, 22.","DOI":"10.3390\/s22208025"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1278","DOI":"10.1109\/TUFFC.2020.3030040","article-title":"A 1.5-D Array for Acoustic Radiation Force (ARF)-Induced Peak Displacement-Based Tissue Anisotropy Assessment With a Row-Column Excitation Method","volume":"68","author":"Wu","year":"2021","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"21322","DOI":"10.1063\/5.0024177","article-title":"3D Printing in Biomedical Engineering: Processes, Materials, and Applications","volume":"8","author":"Lai","year":"2021","journal-title":"Appl. Phys. Rev."},{"key":"ref_24","first-page":"110","article-title":"Photo-Curing 3D Printing Technique and Its Challenges","volume":"5","author":"Quan","year":"2020","journal-title":"Bioact. Mater."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"2723","DOI":"10.1109\/TBME.2022.3150781","article-title":"An Affordable and Easy-to-Use Focused Ultrasound Device for Noninvasive and High Precision Drug Delivery to the Mouse Brain","volume":"69","author":"Hu","year":"2022","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"113706","DOI":"10.1016\/j.sna.2022.113706","article-title":"Design and 3D Printing of Waveguide-Based Ultrasonic Longitudinal-Torsional Transducers for Medical Needle Insertion","volume":"344","author":"Wang","year":"2022","journal-title":"Sens. Actuators A Phys."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"051902","DOI":"10.1063\/5.0035298","article-title":"Acoustic Holograms for Directing Arbitrary Cavitation Patterns","volume":"118","author":"Kim","year":"2021","journal-title":"Appl. Phys. Lett."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1109\/TUFFC.2021.3108448","article-title":"Transcranial Neuromodulation Array With Imaging Aperture for Simultaneous Multifocus Stimulation in Nonhuman Primates","volume":"69","author":"Jones","year":"2022","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.ultras.2015.06.009","article-title":"Phantom Evaluation of Stacked-Type Dual-Frequency 1\u20133 Composite Transducers: A Feasibility Study on Intracavitary Acoustic Angiography","volume":"63","author":"Kim","year":"2015","journal-title":"Ultrasonics"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1078","DOI":"10.1109\/TUFFC.2017.2702010","article-title":"Dual-Frequency Piezoelectric Endoscopic Transducer for Imaging Vascular Invasion in Pancreatic Cancer","volume":"64","author":"Lindsey","year":"2017","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1109\/58.895911","article-title":"High Frequency Properties of Passive Materials for Ultrasonic Transducers","volume":"48","author":"Wang","year":"2001","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Zhou, J., Bai, J., and Liu, Y. (2022). Fabrication and Modeling of Matching System for Air-Coupled Transducer. Micromachines, 13.","DOI":"10.3390\/mi13050781"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"20825","DOI":"10.3390\/s141120825","article-title":"Dual-Frequency Piezoelectric Transducers for Contrast Enhanced Ultrasound Imaging","volume":"14","author":"Martin","year":"2014","journal-title":"Sensors"},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Kim, J., Wu, H., and Jiang, X. (2017, January 3\u20139). Miniaturized Focused Ultrasound Transducers for Intravascular Therapies. Proceedings of the International Mechanical Engineering Congress and Exposition; American Society of Mechanical Engineers Digital Collection, Tampa, FL, USA.","DOI":"10.1115\/IMECE2017-72426"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1109\/58.585184","article-title":"Propagation and Backpropagation for Ultrasonic Wavefront Design","volume":"44","author":"Liu","year":"1997","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1038\/nature19755","article-title":"Holograms for Acoustics","volume":"537","author":"Melde","year":"2016","journal-title":"Nature"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/1\/313\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T01:53:40Z","timestamp":1760147620000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/1\/313"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,28]]},"references-count":36,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,1]]}},"alternative-id":["s23010313"],"URL":"https:\/\/doi.org\/10.3390\/s23010313","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,12,28]]}}}