{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,24]],"date-time":"2026-03-24T02:08:34Z","timestamp":1774318114622,"version":"3.50.1"},"reference-count":27,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2022,12,29]],"date-time":"2022-12-29T00:00:00Z","timestamp":1672272000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Corin Group"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Consideration of pelvic mobility when positioning implants for total hip arthroplasty (THA) has been shown to reduce the risk of complications such as dislocation, squeaking and excessive wear. We aim to test the repeatability of pelvic tilt measurements taken between three positions (standing, flexed-seated and step-up) by an inertial measurement unit (IMU) and hence, evaluate their reliability in screening for high pelvic mobility in patients undergoing THA. The repeated IMU measurements of pelvic tilt were analysed for consistency and compared with measures taken by x-ray analysis. Our study showed greater variation in measures taken by the IMU particularly in the flexed-seated position. The patient\u2019s pelvic tilt in this position negatively correlated with their mid-back angle, suggesting the posture of the patient is a source of variation in the flexed-seated position if not kept consistent during assessments. IMUs were overall able to produce accurate and reliable measurements of pelvic tilt; however, protocols will need to be adjusted to factor in a patient\u2019s mid-back angle when taking future readings.<\/jats:p>","DOI":"10.3390\/s23010377","type":"journal-article","created":{"date-parts":[[2022,12,30]],"date-time":"2022-12-30T03:19:46Z","timestamp":1672370386000},"page":"377","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Repeatability of Inertial Measurement Units for Measuring Pelvic Mobility in Patients Undergoing Total Hip Arthroplasty"],"prefix":"10.3390","volume":"23","author":[{"given":"Sushanth","family":"Vayalapra","sequence":"first","affiliation":[{"name":"Department of Trauma and Orthopaedics, University Hospitals Coventry & Warwickshire NHS Trust, Coventry CV2 2DX, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xueyang","family":"Wang","sequence":"additional","affiliation":[{"name":"WMG, University of Warwick, Coventry CV4 7AL, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arham","family":"Qureshi","sequence":"additional","affiliation":[{"name":"Department of Trauma and Orthopaedics, University Hospitals Coventry & Warwickshire NHS Trust, Coventry CV2 2DX, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5858-1109","authenticated-orcid":false,"given":"Abhinav","family":"Vepa","sequence":"additional","affiliation":[{"name":"Department of Trauma and Orthopaedics, University Hospitals Coventry & Warwickshire NHS Trust, Coventry CV2 2DX, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Usama","family":"Rahman","sequence":"additional","affiliation":[{"name":"Department of Trauma and Orthopaedics, University Hospitals Coventry & Warwickshire NHS Trust, Coventry CV2 2DX, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arnab","family":"Palit","sequence":"additional","affiliation":[{"name":"WMG, University of Warwick, Coventry CV4 7AL, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark A.","family":"Williams","sequence":"additional","affiliation":[{"name":"WMG, University of Warwick, Coventry CV4 7AL, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Richard","family":"King","sequence":"additional","affiliation":[{"name":"Department of Trauma and Orthopaedics, University Hospitals Coventry & Warwickshire NHS Trust, Coventry CV2 2DX, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4000-0198","authenticated-orcid":false,"given":"Mark T.","family":"Elliott","sequence":"additional","affiliation":[{"name":"WMG, University of Warwick, Coventry CV4 7AL, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2022,12,29]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1016\/j.arth.2017.08.013","article-title":"The Current Knowledge on Spinopelvic Mobility","volume":"33","author":"Lum","year":"2018","journal-title":"J. Arthroplast."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"62","DOI":"10.5301\/HIP.2012.9059","article-title":"Hospital cost of treating early dislocation following hip arthroplasty","volume":"22","author":"Procaccini","year":"2012","journal-title":"Hip Int."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1007\/s11999-015-4432-5","article-title":"What Safe Zone? The Vast Majority of Dislocated THAs Are within the Lewinnek Safe Zone for Acetabular Component Position","volume":"474","author":"Abdel","year":"2016","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"762","DOI":"10.1111\/os.12543","article-title":"The Influence of Pelvic Tilt on the Anteversion Angle of the Acetabular Prosthesis","volume":"11","author":"Yang","year":"2019","journal-title":"Orthop. Surg."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1302\/0301-620X.99B2.BJJ-2016-0098.R1","article-title":"Variation in functional pelvic tilt in patients undergoing total hip arthroplasty","volume":"99-B","author":"Pierrepiont","year":"2017","journal-title":"Bone Jt. J."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1016\/j.otsr.2017.02.014","article-title":"The influence of spine-hip relations on total hip replacement: A systematic review","volume":"103","author":"Lazennec","year":"2017","journal-title":"Orthop. Traumatol. Surg. Res."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1080\/17453670510041501","article-title":"Pelvic tilt makes acetabular cup navigation inaccurate","volume":"76","author":"Lembeck","year":"2005","journal-title":"Acta Orthop."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"3056","DOI":"10.1016\/j.arth.2017.04.046","article-title":"Quantifying Pelvic Motion During Total Hip Arthroplasty Using a New Surgical Navigation Device","volume":"32","author":"Schwarzkopf","year":"2017","journal-title":"J. Arthroplast."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"2556","DOI":"10.1016\/j.arth.2018.03.018","article-title":"Predictability of Pelvic Tilt During Total Hip Arthroplasty Using a Traction Table","volume":"33","author":"Roettges","year":"2018","journal-title":"J. Arthroplast."},{"key":"ref_10","first-page":"2638","article-title":"Measurement of Pelvic Movement during Total Hip Arthroplasty Using a Hip Navigation System","volume":"4","author":"Ohashi","year":"2019","journal-title":"Clin. Surg."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1016\/j.ijscr.2014.07.015","article-title":"Can pelvic tilting be ignored in total hip arthroplasty?","volume":"5","author":"Shon","year":"2014","journal-title":"Int. J. Surg. Case Rep."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Inaba, Y., Kobayashi, N., Suzuki, H., Ike, H., Kubota, S., and Saito, T. (2016). Preoperative planning for implant placement with consideration of pelvic tilt in total hip arthroplasty: Postoperative efficacy evaluation. BMC Musculoskelet. Disord., 17.","DOI":"10.1186\/s12891-016-1120-x"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1080\/17434440.2016.1198694","article-title":"Wearable inertial sensors for human movement analysis","volume":"13","author":"Iosa","year":"2016","journal-title":"Expert Rev. Med. Devices"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1007\/s11517-009-0545-x","article-title":"\u201cOutwalk\u201d: A protocol for clinical gait analysis based on inertial and magnetic sensors","volume":"48","author":"Cutti","year":"2010","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Wang, X., Qureshi, A., Vepa, A., Rahman, U., Palit, A., Williams, M.A., King, R., and Elliott, M.T. (2020). A sensor-based screening tool for identifying high pelvic mobility in patients due to undergo total hip arthroplasty. Sensors, 20.","DOI":"10.3390\/s20216182"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Posada-Ordax, J., Cosin-Matamoros, J., Losa-Iglesias, M.E., Becerro-de-Bengoa-Vallejo, R., Esteban-Gonzalo, L., Martin-Villa, C., Calvo-Lobo, C., and Rodriguez-Sanz, D. (2021). Accuracy and Repeatability of Spatiotemporal Gait Parameters Measured with an Inertial Measurement Unit. J. Clin. Med., 10.","DOI":"10.3390\/jcm10091804"},{"key":"ref_17","unstructured":"ClinicalTrials.gov (2021, November 28). Evaluation of X-ray, Acetabular Guides and CT in THR (EXACT), Available online: https:\/\/clinicaltrials.gov\/ct2\/show\/NCT03072706."},{"key":"ref_18","unstructured":"International Congress for Joint Reconstruction (2021, November 28). Patient Specific Acetabular Cup Orientation in Functional Positions using Musculoskeletal Modelling: A Pre-Operative Planning Tool. Available online: https:\/\/icjr.net\/surgeries\/patient-specific-acetabular-cup-orientation-in-functional-positions-using-musculoskeletal-modelling-a-pre-operative-planning-tool."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"J\u00f3\u017awiak, M., Rychlik, M., Musielak, B., Chen, B.P.-J., Idzior, M., and Grzegorzewski, A. (2015). An accurate method of radiological assessment of acetabular volume and orientation in computed tomography spatial reconstruction. BMC Musculoskelet. Disord., 16.","DOI":"10.1186\/s12891-015-0503-8"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1259","DOI":"10.1007\/s00586-014-3739-3","article-title":"Pelvic incidence and pelvic tilt measurements using femoral heads or acetabular domes to identify centers of the hips: Comparison of two methods","volume":"24","author":"Tyrakowski","year":"2015","journal-title":"Eur. Spine J."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"159","DOI":"10.2307\/2529310","article-title":"The Measurement of Observer Agreement for Categorical Data","volume":"33","author":"Landis","year":"1977","journal-title":"Biometrics"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"217","DOI":"10.2165\/00007256-199826040-00002","article-title":"Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine","volume":"26","author":"Atkinson","year":"1998","journal-title":"Sport. Med."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.arth.2018.10.034","article-title":"Functional Safe Zone Is Superior to the Lewinnek Safe Zone for Total Hip Arthroplasty: Why the Lewinnek Safe Zone Is Not Always Predictive of Stability","volume":"34","author":"Tezuka","year":"2019","journal-title":"J. Arthroplast."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.arth.2018.10.035","article-title":"Death of the Lewinnek \u201cSafe Zone\u201d","volume":"34","author":"Dorr","year":"2019","journal-title":"J. Arthroplast."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1016\/j.gaitpost.2008.09.003","article-title":"The reliability of three-dimensional kinematic gait measurements: A systematic review","volume":"29","author":"McGinley","year":"2009","journal-title":"Gait Posture"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1016\/j.medengphy.2015.11.009","article-title":"Validity of an inertial measurement unit to assess pelvic orientation angles during gait, sit-stand transfers and step-up transfers: Comparison with an optoelectronic motion capture system","volume":"38","author":"Bolink","year":"2016","journal-title":"Med. Eng. Phys."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1186\/1475-925X-13-146","article-title":"Estimation of pelvis kinematics in level walking based on a single inertial sensor positioned close to the sacrum: Validation on healthy subjects with stereophotogrammetric system","volume":"13","author":"Benedetti","year":"2014","journal-title":"Biomed. Eng. Online"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/1\/377\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T01:55:43Z","timestamp":1760147743000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/1\/377"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,29]]},"references-count":27,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,1]]}},"alternative-id":["s23010377"],"URL":"https:\/\/doi.org\/10.3390\/s23010377","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,12,29]]}}}