{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,25]],"date-time":"2026-07-25T04:08:23Z","timestamp":1784952503390,"version":"3.55.0"},"reference-count":42,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2023,1,7]],"date-time":"2023-01-07T00:00:00Z","timestamp":1673049600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>pH sensors are increasingly being utilized in the biomedical field and have been implicated in health applications that aim to improve the monitoring and treatment of patients. In this work, a previously developed Titanium Nitride (TiN) solid-state pH sensor is further enhanced, with the potential to be used for pH regulation inside the human body and for other biomedical, industrial, and environmental applications. One of the main limitations of existing solid-state pH sensors is their reduced performance in high redox mediums. The potential shift E0 value of the previously developed TiN pH electrode in the presence of oxidizing or reducing agents is 30 mV. To minimize this redox shift, a Nafion-modified TiN electrode was developed, tested, and evaluated in various mediums. The Nafion-modified electrode has been shown to shift the E0 value by only 2 mV, providing increased accuracy in highly redox samples while maintaining acceptable reaction times. Overcoming the redox interference for pH measurement enables several advantages of the Nafion-modified TiN electrode over the standard pH glass electrode, implicating its use in medical diagnosis, real-time health monitoring, and further development of miniaturized smart sensors.<\/jats:p>","DOI":"10.3390\/s23020699","type":"journal-article","created":{"date-parts":[[2023,1,9]],"date-time":"2023-01-09T07:05:09Z","timestamp":1673247909000},"page":"699","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":18,"title":["Nafion Modified Titanium Nitride pH Sensor for Future Biomedical Applications"],"prefix":"10.3390","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7784-797X","authenticated-orcid":false,"given":"Shimrith Paul","family":"Shylendra","sequence":"first","affiliation":[{"name":"School of Science, Edith Cowan University, Joondalup, WA 6027, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3666-2175","authenticated-orcid":false,"given":"Magdalena","family":"Wajrak","sequence":"additional","affiliation":[{"name":"School of Science, Edith Cowan University, Joondalup, WA 6027, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kamal","family":"Alameh","sequence":"additional","affiliation":[{"name":"School of Science, Edith Cowan University, Joondalup, WA 6027, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0242-4187","authenticated-orcid":false,"given":"James Jin","family":"Kang","sequence":"additional","affiliation":[{"name":"School of Science, Edith Cowan University, Joondalup, WA 6027, Australia"},{"name":"International College, National Taiwan University, Taipei 10617, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,1,7]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"4955","DOI":"10.3390\/s90604955","article-title":"Metal Oxides and Ion-Exchanging Surfaces as pH Sensors in Liquids: State-of-the-Art and Outlook","volume":"9","author":"Kurzweil","year":"2009","journal-title":"Sensors"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"756","DOI":"10.3390\/coatings4040756","article-title":"Recent Developments in R.F. Magnetron Sputtered Thin Films for pH Sensing Applications\u2014An Overview","volume":"4","author":"Maurya","year":"2014","journal-title":"Coatings"},{"key":"ref_3","unstructured":"Riddle, P. (2013). pH meters and their electrodes: Calibration, maintenance and use. Biomed. Sci., 202\u2013205. Available online: https:\/\/www.ibms.org\/includes\/act_download.php?download=2013-apr-ph-meters.pdf."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"209","DOI":"10.3390\/s5040209","article-title":"On calibration of pH meters","volume":"5","author":"Cheng","year":"2005","journal-title":"Sensors"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"878","DOI":"10.1021\/ac9020374","article-title":"Self-calibrating microfabricated iridium oxide pH electrode array for remote monitoring","volume":"82","author":"Carroll","year":"2010","journal-title":"Anal. Chem."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Nguyen, T., Journet, B., Takhedmit, H., and Lissorgues, G. (2022, January 11\u201313). Porous Titanium Nitride electrodes on miniaturised pH sensor for foetal health monitoring application. Proceedings of the 2022 Symposium on Design, Test, Integration and Packaging of MEMS\/MOEMS (DTIP), Pont-a-Mousson, France.","DOI":"10.1109\/DTIP56576.2022.9911738"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1222","DOI":"10.1016\/j.snb.2018.07.022","article-title":"Application of ruthenium oxide pH sensitive electrode to samples with high redox interference","volume":"273","author":"Lonsdale","year":"2018","journal-title":"Sens. Actuators B Chem."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1016\/j.snb.2014.07.067","article-title":"Fabrication of thick film sensitive RuO2-TiO2 and Ag\/AgCl\/KCl reference electrodes and their application for pH measurements","volume":"204","author":"Manjakkal","year":"2014","journal-title":"Sens. Actuators B Chem."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1016\/j.jelechem.2015.10.036","article-title":"Sensing of RuO2\u2013SnO2 thick film pH sensors studied by potentiometric method and electrochemical impedance spectroscopy","volume":"759","author":"Manjakkal","year":"2015","journal-title":"J. Electroanal. Chem."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Higuchi, S., Okada, H., Takamatsu, S., and Itoh, T. (2020). Valve-actuator-integrated reference electrode for an ultra-long-life rumen pH sensor. Sensors, 20.","DOI":"10.3390\/s20051249"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1016\/j.talanta.2017.12.070","article-title":"Manufacture and application of RuO2 solid-state metaloxide pH sensor to common beverages","volume":"180","author":"Lonsdale","year":"2018","journal-title":"Talanta"},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Dong, Q., Sun, X., and He, S. (2021). Iridium Oxide Enabled Sensors Applications. Catalysts, 11.","DOI":"10.3390\/catal11101164"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"102088","DOI":"10.1039\/C6RA17786G","article-title":"Impedimetric blood pH sensor based on MoS2","volume":"6","author":"Awasthi","year":"2016","journal-title":"RSC Adv."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"107511","DOI":"10.1149\/1945-7111\/ac2d3c","article-title":"Nafion protective membrane enables using ruthenium oxide electrodes for pH measurement in milk","volume":"168","author":"Lazouskaya","year":"2021","journal-title":"J. Electrochem. Soc."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Lonsdale, W., Wajrak, M., and Alameh, K. (2017). RuO2 pH Sensor with Super-Glue-Inspired Reference Electrode. Sensors, 17.","DOI":"10.3390\/s17092036"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1016\/j.electacta.2011.09.086","article-title":"Improvement in the long-term stability of screen-printed planar type solid-state Ag\/AgCl reference electrode by introducing poly(dimethylsiloxane) liquid junction","volume":"58","author":"Shitanda","year":"2011","journal-title":"Electrochim. Acta"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1016\/0250-6874(84)80004-9","article-title":"Electronic semiconducting oxides as pH sensors","volume":"5","author":"Fog","year":"1984","journal-title":"Sens. Actuators"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/0925-4005(94)01254-7","article-title":"A solid-state pH sensor based on a Nafion-coated iridium oxide indicator electrode and a polymer-based silver chloride reference electrode","volume":"22","author":"Kinlen","year":"1994","journal-title":"Sens. Actuators B Chem."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1697956","DOI":"10.1155\/2018\/1697956","article-title":"Impact of Various Acids and Bases on the Voltammetric Response of Platinum Group Metal Oxides","volume":"2018","author":"Chalupczok","year":"2018","journal-title":"Int. J. Electrochem."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1002\/(SICI)1521-4109(199907)11:10\/11<788::AID-ELAN788>3.0.CO;2-4","article-title":"Hydrophobic Membranes as Liquid Junction-Free Reference Electrodes","volume":"11","author":"Bakker","year":"1999","journal-title":"Electroanalysis"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Paul Shylendra, S., Lonsdale, W., Wajrak, M., Nur-E-Alam, M., and Alameh, K. (2021). Titanium Nitride Thin Film Based Low-Redox-Interference Potentiometric pH Sensing Electrodes. Sensors, 21.","DOI":"10.3390\/s21010042"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1364\/OME.2.000478","article-title":"Titanium nitride as a plasmonic material for visible and near-infrared wavelengths","volume":"2","author":"Naik","year":"2012","journal-title":"Opt. Mater. Express"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2478","DOI":"10.3390\/s90402478","article-title":"Fabrication and Characterization of a Ruthenium Nitride Membrane for Electrochemical pH Sensors","volume":"9","author":"Liao","year":"2009","journal-title":"Sensors"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.surfcoat.2004.07.066","article-title":"Effect of nitrogen flow rate on structure and properties of nanocrystalline TiN thin films produced by unbalanced magnetron sputtering","volume":"191","author":"Huang","year":"2005","journal-title":"Surf. Coat. Technol."},{"key":"ref_25","first-page":"787","article-title":"Study effects of thin film thickness on the behavior of CuS EGFET implemented as pH sensor","volume":"11","author":"Sabah","year":"2016","journal-title":"DJNB"},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Nur-E-Alam, M., Rahman, M.M., Basher, M.K., Vasiliev, M., and Alameh, K. (2020). Optical and Chromaticity Properties of Metal-Dielectric Composite-Based Multilayer Thin-Film Structures Prepared by RF Magnetron Sputtering. Coatings, 10.","DOI":"10.20944\/preprints202002.0260.v1"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"012036","DOI":"10.1088\/1742-6596\/927\/1\/012036","article-title":"Electrical properties of titanium nitride films synthesized by reactive magnetron sputtering","volume":"927","author":"Mohammed","year":"2017","journal-title":"J. Phys. Conf. Ser."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"2676","DOI":"10.1063\/1.1691195","article-title":"Amorphous boron carbon nitride as a pH sensor","volume":"84","author":"Li","year":"2004","journal-title":"Appl. Phys. Lett."},{"key":"ref_29","unstructured":"Yusof, K.A., Noh, N.I., Herman, S.H., Abdullah, A.Z., Zolkapli, M., and Abdullah, W.F. (2013, January 19\u201320). pH sensing characteristics of silicon nitride thin film and silicon nitride-based ISFET sensor. Proceedings of the 2013 IEEE 4th Control and System Graduate Research Colloquium, IEEE, Shah Alam, Malaysia."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"6311","DOI":"10.1143\/JJAP.40.6311","article-title":"Titanium Nitride Membrane Application to Extended Gate Field Effect Transistor pH Sensor Using VLSI Technology","volume":"40","author":"Chin","year":"2001","journal-title":"Jpn. J. Appl. Phys."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"044108","DOI":"10.1063\/1.1851000","article-title":"Structure and electronic properties of zirconium and hafnium nitrides and oxynitrides","volume":"97","author":"Bazhanov","year":"2005","journal-title":"J. Appl. Phys."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.1109\/JSEN.2010.2080317","article-title":"Highly Sensitive pH Sensing Using an Indium Nitride Ion-Sensitive Field-Effect Transistor","volume":"11","author":"Chang","year":"2011","journal-title":"IEEE Sens. J."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1016\/j.msea.2006.09.021","article-title":"Properties of titanium nitride films prepared by direct current magnetron sputtering","volume":"445\u2013446","author":"Jeyachandran","year":"2007","journal-title":"Mater. Sci. Eng. A"},{"key":"ref_34","unstructured":"Lengauer, W. (2015). The Reactivity of Some Transition Metal Nitrides and Carbides, Wiley."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"4550","DOI":"10.1039\/C6TA08308K","article-title":"Effect of oxidative surface treatments on charge storage at titanium nitride surfaces for supercapacitor applications","volume":"5","author":"Gray","year":"2017","journal-title":"J. Mater. Chem. A"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"6481","DOI":"10.1039\/C5AN00617A","article-title":"An instantly usable paper-based screen-printed solid-state KCl\/Ag\/AgCl reference electrode with long-term stability","volume":"140","author":"Shitanda","year":"2015","journal-title":"Analyst"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1016\/S0257-8972(96)03094-0","article-title":"dos Characterization of titanium nitride films prepared by d.c. reactive magnetron sputtering at different nitrogen pressures","volume":"90","author":"Meng","year":"1997","journal-title":"Surf. Coat. Technol."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"012035","DOI":"10.1088\/1742-6596\/872\/1\/012035","article-title":"Mechanical properties of titanium nitride films obtained by reactively sputtering with hot target","volume":"872","author":"Babinova","year":"2017","journal-title":"J. Phys. Conf. Ser."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"2786","DOI":"10.1364\/OME.5.002786","article-title":"Optimization of sputtered titanium nitride as a tunable metal for plasmonic applications","volume":"5","author":"Zgrabik","year":"2015","journal-title":"Opt. Mater. Express"},{"key":"ref_40","first-page":"9159350","article-title":"Titanium nitride as an electrode material for high charge density applications","volume":"394","author":"Patan","year":"2007","journal-title":"Theses"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"834","DOI":"10.1016\/j.electacta.2015.09.155","article-title":"Titanium nitride as an electrocatalyst for V(II)\/V(III)redox couples in all-vanadium redox flow batteries","volume":"182","author":"Yang","year":"2015","journal-title":"Electrochem. Acta"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"214305","DOI":"10.1016\/j.ccr.2021.214305","article-title":"Portable electrochemical sensing methodologies for on-site detection of pesticide residues in fruits and vegetables","volume":"453","author":"Umapathi","year":"2022","journal-title":"Coord. Chem. Rev."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/2\/699\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T18:02:56Z","timestamp":1760119376000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/2\/699"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,7]]},"references-count":42,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2023,1]]}},"alternative-id":["s23020699"],"URL":"https:\/\/doi.org\/10.3390\/s23020699","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1,7]]}}}