{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T01:48:33Z","timestamp":1760147313229,"version":"build-2065373602"},"reference-count":19,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2023,1,26]],"date-time":"2023-01-26T00:00:00Z","timestamp":1674691200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"The Ministry of Education of the Republic of Korea and the National Research Foundation of Korea","award":["NRF-2021S1A5A2A03065436"],"award-info":[{"award-number":["NRF-2021S1A5A2A03065436"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The shoe upper hides the foot motion on the insole, so it has been challenging to measure the non-slip function of socks in a dynamic motor task. The study aimed to propose a method to estimate the non-slip function of socks in an acute maneuver. Participants performed a shuttle run task while wearing three types of socks with different frictional properties. The forces produced by foot movement on the upper during the task were measured by pressure sensors installed at the upper. A force platform was also used to measure the ground reaction force at the outsole and ground. Peak force and impulse values computed by using forces measured by the pressure sensors were significantly different between the sock conditions, while there were no such differences in those values computed by using ground reaction forces measured by a force platform. The results suggested that the non-slip function of socks could be quantified by measuring forces at the foot-upper interface. The method could be an affordable option to measure the non-slip function of socks with minimal effects from skin artifacts and shoe upper integrity.<\/jats:p>","DOI":"10.3390\/s23031378","type":"journal-article","created":{"date-parts":[[2023,1,27]],"date-time":"2023-01-27T01:27:58Z","timestamp":1674782878000},"page":"1378","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A Method for Accessing the Non-Slip Function of Socks in an Acute Maneuver"],"prefix":"10.3390","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6688-9442","authenticated-orcid":false,"given":"Dongwook","family":"Seo","sequence":"first","affiliation":[{"name":"College of Physical Education, Kookmin University, Seoul 02707, Republic of Korea"}]},{"given":"Jinsu","family":"Eun","sequence":"additional","affiliation":[{"name":"College of Physical Education, Kookmin University, Seoul 02707, Republic of Korea"}]},{"given":"Yeonwoo","family":"Yu","sequence":"additional","affiliation":[{"name":"College of Physical Education, Kookmin University, Seoul 02707, Republic of Korea"}]},{"given":"Sangsoo","family":"Park","sequence":"additional","affiliation":[{"name":"School of Global Sport Studies, Korea University Sejong Campus, Sejong 30019, Republic of Korea"}]},{"given":"Kikwang","family":"Lee","sequence":"additional","affiliation":[{"name":"College of Physical Education, Kookmin University, Seoul 02707, Republic of Korea"}]}],"member":"1968","published-online":{"date-parts":[[2023,1,26]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"117","DOI":"10.2165\/00128071-200001020-00007","article-title":"Diabetic Foot Ulcers","volume":"1","author":"Phillips","year":"2000","journal-title":"Am. J. Clin. Dermatol."},{"key":"ref_2","first-page":"K-A","article-title":"New socks offer relief, blister guard system with Teflon reduces friction between foot and sock","volume":"26","author":"Delporte","year":"1997","journal-title":"Am. Text. Int."},{"key":"ref_3","first-page":"350","article-title":"Lateral stability in sideward cutting movements","volume":"28","author":"Stacoff","year":"1996","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1351","DOI":"10.1080\/02640414.2022.2080163","article-title":"Grip socks improve slalom course performance and reduce in-shoe foot displacement of the forefoot in male and female sports players","volume":"40","author":"Apps","year":"2022","journal-title":"J. Sports Sci."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"3799","DOI":"10.1016\/j.jbiomech.2014.10.028","article-title":"In-shoe plantar tri-axial stress profiles during maximum-effort cutting maneuvers","volume":"47","author":"Cong","year":"2014","journal-title":"J. Biomech."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1177\/0040517514530029","article-title":"The effect of fiber type, yarn structure and fabric structure on the frictional characteristics of sock fabrics","volume":"85","author":"Lowe","year":"2015","journal-title":"Text. Res. J."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1080\/15298669291359672","article-title":"Floor\/shoe slip resistance measurement","volume":"53","author":"Chaffin","year":"1992","journal-title":"Am. Ind. Hyg. Assoc. J."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1007\/s12221-010-0277-4","article-title":"Effect of weight and apllied force on the friction coefficient of the spunlace nonwoven fabrics","volume":"11","author":"Kalebek","year":"2010","journal-title":"Fibers Polym."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"759","DOI":"10.1016\/j.proeng.2016.06.324","article-title":"Investigating foot-sock friction: A comparison of two different methodologies","volume":"147","author":"Tasron","year":"2016","journal-title":"Procedia Eng."},{"key":"ref_10","first-page":"213","article-title":"Skin-Fabric Friction and Other Performance Characteristics of Socks Fabrics Produced from Cellulosic Fibers","volume":"28","author":"Kaplan","year":"2018","journal-title":"Text. Appar."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"83","DOI":"10.4197\/Eng.21-2.5","article-title":"Friction behaviour of Bare Foot and Foot Wearing Socks Sliding against Marble Flooring Tiles","volume":"21","author":"Ali","year":"2010","journal-title":"JKAU Eng. Sci."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"D\u2019Souza, B., Kasar, A.K., Jones, J., Skeete, A., Rader, L., Kumar, P., and Menezes, P.L. (2022). A Brief Review on Factors Affecting the Tribological Interaction between Human Skin and Different Textile Materials. Materials, 15.","DOI":"10.3390\/ma15062184"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Eun, J., Ryue, J., Park, S., and Lee, K. (2022). A Novel Method to Measure the Static Coefficient of Friction for Socks. Sensors, 22.","DOI":"10.3390\/s22155525"},{"key":"ref_14","first-page":"161","article-title":"Material properties of commonly-used interface materials and their static coefficients of friction with skin and socks","volume":"35","author":"Sanders","year":"1998","journal-title":"J. Rehabil. Res. Dev."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1080\/02640414.2019.1690618","article-title":"Footwear insoles with higher frictional properties enhance performance by reducing in-shoe sliding during rapid changes of direction","volume":"38","author":"Apps","year":"2020","journal-title":"J. Sports Sci."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1390","DOI":"10.1249\/00005768-199212000-00013","article-title":"Heel movement within a court shoe","volume":"24","author":"Reinschmidt","year":"1992","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/j.medengphy.2011.06.017","article-title":"Determining the maximum diameter for holes in the shoe without compromising shoe integrity when using a multi-segment foot model","volume":"34","author":"Shultz","year":"2012","journal-title":"Med. Eng. Phys."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1080\/19424280.2022.2038692","article-title":"The impact of self-lacing technology on foot containment during dynamic cutting","volume":"14","author":"Myers","year":"2022","journal-title":"Footwear Sci."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1680","DOI":"10.1249\/MSS.0b013e318216ea37","article-title":"Technical ability of force application as a determinant factor of sprint performance","volume":"43","author":"Morin","year":"2011","journal-title":"Med. Sci. Sport. Exerc."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/3\/1378\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T18:16:05Z","timestamp":1760120165000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/3\/1378"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,26]]},"references-count":19,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2023,2]]}},"alternative-id":["s23031378"],"URL":"https:\/\/doi.org\/10.3390\/s23031378","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2023,1,26]]}}}