{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T19:59:14Z","timestamp":1777406354166,"version":"3.51.4"},"reference-count":39,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2023,1,28]],"date-time":"2023-01-28T00:00:00Z","timestamp":1674864000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100004504","name":"Research Council of Lithuania","doi-asserted-by":"publisher","award":["P-MIP-22-277"],"award-info":[{"award-number":["P-MIP-22-277"]}],"id":[{"id":"10.13039\/501100004504","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A measurement system based on the colossal magnetoresistance CMR-B-scalar sensor was developed for the measurement of short-duration high-amplitude magnetic fields. The system consists of a magnetic field sensor made from thin nanostructured manganite film with minimized memory effect, and a magnetic field recording module. The memory effect of the La1\u2212xSrx(Mn1\u2212yCoy)zO3 manganite films doped with different amounts of Co and Mn was investigated by measuring the magnetoresistance (MR) and resistance relaxation in pulsed magnetic fields up to 20 T in the temperature range of 80\u2013365 K. It was found that for low-temperature applications, films doped with Co (LSMCO) are preferable due to the minimized magnetic memory effect at these temperatures, compared with LSMO films without Co. For applications at temperatures higher than room temperature, nanostructured manganite LSMO films with increased Mn content above the stoichiometric level have to be used. These films do not exhibit magnetic memory effects and have higher MR values. To avoid parasitic signal due to electromotive forces appearing in the transmission line of the sensor during measurement of short-pulsed magnetic fields, a bipolar-pulsed voltage supply for the sensor was used. For signal recording, a measurement module consisting of a pulsed voltage generator with a frequency up to 12.5 MHz, a 16-bit ADC with a sampling rate of 25 MHz, and a microprocessor was proposed. The circuit of the measurement module was shielded against low- and high-frequency electromagnetic noise, and the recorded signal was transmitted to a personal computer using a fiber optic link. The system was tested using magnetic field generators, generating magnetic fields with pulse durations ranging from 3 to 20 \u03bcs. The developed magnetic field measurement system can be used for the measurement of high-pulsed magnetic fields with pulse durations in the order of microseconds in different fields of science and industry.<\/jats:p>","DOI":"10.3390\/s23031435","type":"journal-article","created":{"date-parts":[[2023,1,30]],"date-time":"2023-01-30T02:01:18Z","timestamp":1675044078000},"page":"1435","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Measurement System for Short-Pulsed Magnetic Fields"],"prefix":"10.3390","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6552-0862","authenticated-orcid":false,"given":"Voitech","family":"Stankevi\u010d","sequence":"first","affiliation":[{"name":"Department of Functional Materials and Electronics, Center for Physical Sciences and Technology, Sauletekio Ave. 3, 10257 Vilnius, Lithuania"},{"name":"Faculty of Electronics, Vilnius Gediminas Technical University, 10223 Vilnius, Lithuania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1815-357X","authenticated-orcid":false,"given":"Skirmantas","family":"Ker\u0161ulis","sequence":"additional","affiliation":[{"name":"Department of Functional Materials and Electronics, Center for Physical Sciences and Technology, Sauletekio Ave. 3, 10257 Vilnius, Lithuania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Justas","family":"Dilys","sequence":"additional","affiliation":[{"name":"Department of Functional Materials and Electronics, Center for Physical Sciences and Technology, Sauletekio Ave. 3, 10257 Vilnius, Lithuania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7966-3573","authenticated-orcid":false,"given":"Vytautas","family":"Bleizgys","sequence":"additional","affiliation":[{"name":"Department of Functional Materials and Electronics, Center for Physical Sciences and Technology, Sauletekio Ave. 3, 10257 Vilnius, Lithuania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mindaugas","family":"Vili\u016bnas","sequence":"additional","affiliation":[{"name":"Institute of Chemical Physics, Faculty of Physics, Vilnius University, 03225 Vilnius, Lithuania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vilius","family":"Vertelis","sequence":"additional","affiliation":[{"name":"Department of Functional Materials and Electronics, Center for Physical Sciences and Technology, Sauletekio Ave. 3, 10257 Vilnius, Lithuania"},{"name":"Faculty of Electronics, Vilnius Gediminas Technical University, 10223 Vilnius, Lithuania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4666-2996","authenticated-orcid":false,"given":"Andrius","family":"Maneikis","sequence":"additional","affiliation":[{"name":"Department of Functional Materials and Electronics, Center for Physical Sciences and Technology, Sauletekio Ave. 3, 10257 Vilnius, Lithuania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vakaris","family":"Rudokas","sequence":"additional","affiliation":[{"name":"Department of Functional Materials and Electronics, Center for Physical Sciences and Technology, Sauletekio Ave. 3, 10257 Vilnius, Lithuania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Valentina","family":"Plau\u0161inaitien\u0117","sequence":"additional","affiliation":[{"name":"Department of Functional Materials and Electronics, Center for Physical Sciences and Technology, Sauletekio Ave. 3, 10257 Vilnius, Lithuania"},{"name":"Faculty of Chemistry and Geosciences, Vilnius University, 03225 Vilnius, Lithuania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0912-4563","authenticated-orcid":false,"given":"Nerija","family":"\u017durauskien\u0117","sequence":"additional","affiliation":[{"name":"Department of Functional Materials and Electronics, Center for Physical Sciences and Technology, Sauletekio Ave. 3, 10257 Vilnius, Lithuania"},{"name":"Faculty of Electronics, Vilnius Gediminas Technical University, 10223 Vilnius, Lithuania"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2023,1,28]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Abate, D., and Cavazzana, R. (2022). Effective Area Measurements of Magnetic Pick-Up Coil Sensors for RFX-mod2. Sensors, 22.","DOI":"10.3390\/s22249767"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1851","DOI":"10.1109\/TMAG.1981.1061385","article-title":"A magnetic spectrometer with gradient field","volume":"17","author":"Coupland","year":"1981","journal-title":"IEEE Trans. Magn."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"R31","DOI":"10.1088\/0957-0233\/18\/3\/R01","article-title":"Indution coil sensors\u2014A review","volume":"18","author":"Tumanski","year":"2007","journal-title":"Meas. Sci. Technol."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Wei, S., Liao, X., Zhang, H., Pang, J., and Zhou, Y. (2021). Recent Progress of Fluxgate Magnetic Sensors: Basic Research and Application. Sensors, 21.","DOI":"10.3390\/s21041500"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Cho, H.-S., Yang, J.-H., Lee, S.-Y., Lee, J.-W., and Lee, J.-H. (2022). Wearable Fabric Loop Sensor Based on Magnetic\u2013Field\u2013Induced Conductivity for Simultaneous Detection of Cardiac Activity and Respiration Signals. Sensors, 22.","DOI":"10.3390\/s22249884"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Marconato, N. (2022). Design of Integrated Micro-Fluxgate Magnetic Sensors: Advantages and Challenges of Numerical Analyses. Sensors, 22.","DOI":"10.3390\/s22030961"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"10J12","DOI":"10.1063\/1.5039356","article-title":"Application of a Hall sensor for pulsed magnetic field measurement in the FAT\u2013CM FRC experiments","volume":"89","author":"Hosozawa","year":"2018","journal-title":"Rev. Sci. Instr."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/0924-4247(94)85020-8","article-title":"Micromachined Hall elements for two-dimensional magnetic-field sensing","volume":"40","author":"Kawahito","year":"1994","journal-title":"Sens. Actuators A Phys."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"631","DOI":"10.1109\/JSEN.2006.874493","article-title":"Magnetic sensors and their applications","volume":"6","author":"Lenz","year":"2006","journal-title":"IEEE Sens. J."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"28665","DOI":"10.3390\/s151128665","article-title":"Recent developments of magnetoresistive sensors for industrial applications","volume":"15","author":"Jogschies","year":"2015","journal-title":"Sensors"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"02200","DOI":"10.1088\/2631-8695\/ac0838","article-title":"Magnetic sensors-A review and recent technologies","volume":"3","author":"Khan","year":"2021","journal-title":"Eng. Res. Express"},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Murzin, D., Mapps, D.J., Levada, K., Belyaev, V., Omelyanchik, A., Panina, L., and Rodionova, V. (2020). Ultrasensitive Magnetic Field Sensors for Biomedical Applications. Sensors, 20.","DOI":"10.3390\/s20061569"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"0800130","DOI":"10.1109\/TMAG.2019.2896036","article-title":"Magnetoresistive sensor development roadmap (non-recording applications)","volume":"55","author":"Zheng","year":"2019","journal-title":"IEEE Trans. Magn."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Tang, W., Lyu, F., Wang, D., and Pan, H. (2018). A new design of a single\u2013device 3d Hall sensor: Cross\u2013shaped 3D Hall sensor. Sensors, 18.","DOI":"10.3390\/s18041065"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1038\/s41928-021-00542-8","article-title":"A spin\u2013orbit torque device for sensing three-dimensional magnetic fields","volume":"4","author":"Li","year":"2021","journal-title":"Nat. Electron."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1038\/s43246-021-00206-2","article-title":"Three-dimensional sensing of the magnetic-field vector by a compact planar-type Hall device","volume":"2","author":"Shiogai","year":"2021","journal-title":"Commun. Mater."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"4144","DOI":"10.1109\/TMAG.2012.2237019","article-title":"Three-Axis Magnetic Field Induction Sensor Realized on Buckled Cantilever Plate","volume":"49","author":"Alfadhel","year":"2013","journal-title":"IEEE Trans. Magn."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"044704","DOI":"10.1063\/1.4870280","article-title":"Pulsed magnetic field measurement system based on colossal magnetoresistance-B-scalar sensors for railgun investigation","volume":"85","author":"Liebfried","year":"2014","journal-title":"Rev. Sci. Instrum."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1526","DOI":"10.1109\/TPS.2013.2248026","article-title":"Diagnostic capabilities for electromagnetic railguns","volume":"41","author":"Haran","year":"2013","journal-title":"IEEE Trans. Plasma Sci."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"092407","DOI":"10.1063\/1.4749820","article-title":"Nanostructured thin manganite films in megagauss magnetic field","volume":"101","author":"Abrutis","year":"2012","journal-title":"Appl. Phys. Lett."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"2773","DOI":"10.1109\/TPS.2017.2688727","article-title":"Magnetoresistance relaxation anisotropy of nanostructured La-Sr(Ca)-Mn-O films induced by high-pulsed magnetic fields","volume":"45","author":"Pavilonis","year":"2017","journal-title":"IEEE Trans. Plasma Sci."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.crhy.2012.11.005","article-title":"Beyond 100 Tesla: Scientific experiments using single-turn coils","volume":"14","author":"Portugall","year":"2013","journal-title":"Comptes Rendus Phys."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2354","DOI":"10.1088\/0022-3727\/32\/18\/306","article-title":"Megagauss magnetic field generation in single-turn coils: New frontiers for scientific experiments","volume":"32","author":"Portugall","year":"1999","journal-title":"J. Phys. D Appl. Phys."},{"key":"ref_24","unstructured":"Novac, B.M., Smith, I.R., Rankin, D.F., Pu, Z., and Hubbard, M. (2003, January 15\u201318). Electromagnetic flux-compression: Experimentation. Proceedings of the 14th IEEE International Pulsed Power Conference, Dallas, TX, USA. Digest of Technical Papers."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Novac, B.M., Hook, N.D., and Smith, I.R. (2010, January 23\u201327). Magnetic flux-compression driven by exploding single-turn coils. Proceedings of the IEEE International Power Modulator and High Voltage Conference, Atlanta, GA, USA.","DOI":"10.1109\/IPMHVC.2010.5958311"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1007\/s40436-016-0162-5","article-title":"Measurement and analysis technologies for magnetic pulse welding: Established methods and new strategies","volume":"4","author":"Bellmann","year":"2016","journal-title":"Adv. Manuf."},{"key":"ref_27","first-page":"21","article-title":"Magnetic pulse welding","volume":"1","author":"Broeckhove","year":"2011","journal-title":"Int. J. Sustain. Constr. Des."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"104409","DOI":"10.1103\/PhysRevB.64.104409","article-title":"Magnetic relaxation in bulk and film manganite compounds","volume":"64","author":"Sirena","year":"2001","journal-title":"Phys. Rev. B"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"2830","DOI":"10.1109\/TPS.2013.2261558","article-title":"Magnetoresistance relaxation in thin La-Sr-Mn-O films exposed to high-pulsed magnetic fields","volume":"41","author":"Zurauskiene","year":"2013","journal-title":"IEEE Trans. Plasma Sci."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"4002645","DOI":"10.1109\/TMAG.2017.2708980","article-title":"Nanostructured La\u2013Sr\u2013Mn\u2013Co\u2013O films for room-temperature pulsed magnetic field sensors","volume":"53","author":"Zurauskiene","year":"2017","journal-title":"IEEE Trans. Magn."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"168340","DOI":"10.1016\/j.jmmm.2021.168340","article-title":"Magnetoresistance and its relaxation of nanostructured La\u2013Sr\u2013Mn\u2013Co\u2013O films: Application for low temperature magnetic sensors","volume":"539","author":"Zurauskiene","year":"2021","journal-title":"J. Magn. Magn. Mater."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"4530","DOI":"10.1109\/TPS.2019.2911545","article-title":"Increase of operating temperature of magnetic field sensors based on La\u2013Sr\u2013Mn\u2013O films with Mn excess","volume":"47","author":"Zurauskiene","year":"2019","journal-title":"IEEE Trans. Plasma Sci."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"2885","DOI":"10.1109\/TPS.2013.2261827","article-title":"High-Frequency CMR\u2013B\u2013Scalar Sensor for Pulsed Magnetic Field Measurement","volume":"41","author":"Balevicius","year":"2013","journal-title":"IEEE Trans. Plasma Sci."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1007\/s10909-009-0140-4","article-title":"Micro-miniature Hall probes for applications at pulsed magnetic fields up to 87 Tesla","volume":"159","author":"Mironov","year":"2010","journal-title":"J. Low Temp. Phys."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1088\/1742-6596\/51\/1\/070","article-title":"Magnetotransport measurements of low dimensional conductors under pulsed ultra-high magnetic fields","volume":"51","author":"Imamura","year":"2006","journal-title":"J. Phys. Conf. Ser."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"12996","DOI":"10.1007\/s10853-018-2567-y","article-title":"Magnetoresistive properties of thin nanostructured manganite films grown by metalorganic chemical vapour deposition onto glass-ceramics substrates","volume":"53","author":"Zurauskiene","year":"2018","journal-title":"J. Mater. Sci."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/S0040-6090(02)00352-8","article-title":"Magnetoresistant La1yxSrxMnO3 films by pulsed injection metal organic chemical vapor deposition: Effect of deposition conditions, substrate material and film thickness","volume":"413","author":"Abrutis","year":"2002","journal-title":"Thin Solid Films"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"256","DOI":"10.3762\/bjnano.10.24","article-title":"Relation between thickness, crystallite size and magnetoresistance of nanostructured La1\u2212xSrxMnyO3\u00b1\u03b4 films for magnetic field sensors","volume":"10","author":"Lukose","year":"2019","journal-title":"Beilstein J. Nanotechnol."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1007\/s10909-009-0063-0","article-title":"Vilnius high magnetic field centre facilities","volume":"159","author":"Novickij","year":"2010","journal-title":"J. Low Temp. Phys."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/3\/1435\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T18:17:40Z","timestamp":1760120260000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/3\/1435"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,28]]},"references-count":39,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2023,2]]}},"alternative-id":["s23031435"],"URL":"https:\/\/doi.org\/10.3390\/s23031435","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1,28]]}}}