{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T01:49:33Z","timestamp":1760147373755,"version":"build-2065373602"},"reference-count":20,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2023,1,29]],"date-time":"2023-01-29T00:00:00Z","timestamp":1674950400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"ITER Organization"},{"name":"Fusion for Energy"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>In the ITER neutral beam injectors (NBI), the presence of an external variable magnetic field generated by the ITER tokamak itself, could deflect the ion beam during acceleration and cause a loss of beam focusing. For this reason, the ion source, the accelerator and the neutralizer will be shielded from external magnetic field by means of a passive magnetic shield and a system of active correction and compensation coils (ACCC). The ACCC will operate in a feedback control loop and thus require the measurement of magnetic field inside the NBI vessel. Magnetic sensors for this application must be capable of measuring DC and slow variable magnetic fields, and be vacuum-compatible, radiation-hard and robust, since they will be subjected to neutron flux produced by fusion reactions in the tokamak and inaccessible for maintenance. This paper describes the realization and tests of fluxgate magnetic sensors prototypes specifically designed for this purpose before the installation in MITICA and ITER.<\/jats:p>","DOI":"10.3390\/s23031492","type":"journal-article","created":{"date-parts":[[2023,1,30]],"date-time":"2023-01-30T02:28:34Z","timestamp":1675045714000},"page":"1492","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Realization and Tests of Prototype Fluxgate Magnetic Sensors for the ITER Neutral Beam Injectors"],"prefix":"10.3390","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3060-8466","authenticated-orcid":false,"given":"Giuseppe","family":"Chitarin","sequence":"first","affiliation":[{"name":"Department of Management and Engineering, University of Padova, Strad. S. Nicola 3, 36100 Vicenza, Italy"},{"name":"Consorzio RFX, CNR, ENEA, INFN, Universit\u00e0 di Padova, Acciaierie Venete SpA, Corso Stati Uniti 4, 35127 Padova, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0452-5456","authenticated-orcid":false,"given":"Nicol\u00f2","family":"Marconato","sequence":"additional","affiliation":[{"name":"Consorzio RFX, CNR, ENEA, INFN, Universit\u00e0 di Padova, Acciaierie Venete SpA, Corso Stati Uniti 4, 35127 Padova, Italy"},{"name":"Department of Industrial Engineering, University of Padova, via Gradenigo 6a, 35131 Padova, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stefan","family":"Mayer","sequence":"additional","affiliation":[{"name":"Stefan Mayer Instruments GmbH & Co. KG, Hans-B\u00f6ckler-Str. 21 c, 46535 Dinslaken, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2023,1,29]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"025005","DOI":"10.1088\/1367-2630\/19\/2\/025005","article-title":"Overview of the design of the ITER heating neutral beam injectors","volume":"19","author":"Hemsworth","year":"2017","journal-title":"New J. Phys."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"085004","DOI":"10.1088\/1367-2630\/aa78e8","article-title":"The PRIMA Test Facility: SPIDER and MITICA test-beds for ITER neutral beam injectors","volume":"19","author":"Toigo","year":"2017","journal-title":"New J. Phys."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"112622","DOI":"10.1016\/j.fusengdes.2021.112622","article-title":"On the road to ITER NBIs: SPIDER improvement after first operation and MITICA construction progress","volume":"168","author":"Toigo","year":"2021","journal-title":"Fusion Eng. Des."},{"key":"ref_4","unstructured":"Svensson, L. (2014). ITER Technical Specification, ITER. ITER IDM UID NNM5VQ."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1109\/TPS.2009.2037226","article-title":"The magnetic diagnostics set for ITER","volume":"38","author":"Testa","year":"2010","journal-title":"IEEE Trans. Plasma Sci."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"106032","DOI":"10.1088\/1741-4326\/ac8aad","article-title":"Long term operation of the radiation-hard Hall probes system and the path toward a high performance hybrid magnetic field sensor","volume":"62","author":"Quercia","year":"2022","journal-title":"Nucl. Fusion"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"10J119","DOI":"10.1063\/1.5038871","article-title":"Steady state magnetic sensors for ITER and beyond: Development and final design","volume":"89","author":"Kocan","year":"2018","journal-title":"Rev. Sci. Instrum."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Moreau, P., Bolshakova, I., Brichard, B., Chitarin, G., Delogu, R., Duran, I., Encheva, A., Fournier, Y., Galo, A., and Le-Luyer, A. (2009, January 7\u201310). Development of a Magnetic Diagnostic Suitable for the ITER Radiation Environment. Proceedings of the 2009 1st International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and Their Applications, Marseille, France.","DOI":"10.1109\/ANIMMA.2009.5503812"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Marconato, N. (2022). Design of Integrated Micro-Fluxgate Magnetic Sensors: Advantages and Challenges of Numerical Analyses. Sensors, 22.","DOI":"10.3390\/s22030961"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1007\/978-3-319-34070-8_2","article-title":"Parallel fluxgate magnetometers","volume":"19","author":"Janosek","year":"2017","journal-title":"Smart Sens. Meas. Instrum."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1038\/nphys566","article-title":"Optical magnetometry","volume":"3","author":"Budker","year":"2007","journal-title":"Nat. Phys."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"780","DOI":"10.1016\/j.jnucmat.2011.01.081","article-title":"Nuclear technology aspects of ITER vessel-mounted diagnostics","volume":"407","author":"Vayakis","year":"2011","journal-title":"J. Nucl. Mater."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/0924-4247(92)80159-Z","article-title":"Review of flux-gate sensors","volume":"33","author":"Ripka","year":"1992","journal-title":"Sens. Actuators A"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1016\/j.fusengdes.2017.03.080","article-title":"Feasibility study of a flux-gate magnetic field sensor suitable for ITER Neutral Beam Injectors","volume":"123","author":"Chitarin","year":"2017","journal-title":"Fusion Eng. Des."},{"key":"ref_15","unstructured":"Worth, L. (2012). ITER Vacuum Handbook with Attachment 1 and Appendicies 3 and 12, ITER. ITER IDM UID AKEFTF."},{"key":"ref_16","unstructured":"Worth, L. (2009). ITER Vacuum Handbook Appendix 10\u2014Vacuum Cables, ITER. ITER IDM UID 2ETNLM."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Snoeij, M., Schaffer, V., Udayashankar, S., and Ivanov, M. (2015, January 14\u201318). An integrated fluxgate magnetometer for use in closed-loop\/open-loop isolated current sensing. Proceedings of the ESSCIRC Conference 2015\u201441st European Solid-State Circuits Conference (ESSCIRC), Graz, Austria.","DOI":"10.1109\/ESSCIRC.2015.7313877"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1088\/0022-3735\/12\/4\/001","article-title":"The fluxgate magnetometer","volume":"12","author":"Primdahl","year":"1979","journal-title":"J. Phys. E Sci. Instrum."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1109\/TMAG.1974.1058457","article-title":"Fluxgate Magnetometers for Outer Planets Exploration","volume":"10","year":"1974","journal-title":"IEEE Trans. Magn."},{"key":"ref_20","unstructured":"Musmann, G., and Afanassiev, Y. (2010). Fluxgate Magnetometers for Space Research, Books on Demand GmbH."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/3\/1492\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T18:18:53Z","timestamp":1760120333000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/3\/1492"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,29]]},"references-count":20,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2023,2]]}},"alternative-id":["s23031492"],"URL":"https:\/\/doi.org\/10.3390\/s23031492","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2023,1,29]]}}}