{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T01:51:59Z","timestamp":1760147519836,"version":"build-2065373602"},"reference-count":30,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2023,2,9]],"date-time":"2023-02-09T00:00:00Z","timestamp":1675900800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001691","name":"JSPS KAKENHI","doi-asserted-by":"publisher","award":["19K22958","JPMJSP2135"],"award-info":[{"award-number":["19K22958","JPMJSP2135"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100002241","name":"JST SPRING","doi-asserted-by":"publisher","award":["19K22958","JPMJSP2135"],"award-info":[{"award-number":["19K22958","JPMJSP2135"]}],"id":[{"id":"10.13039\/501100002241","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Monitoring core body temperature (CBT) allows observation of heat stress and thermal comfort in various environments. By introducing a Peltier element, we improved the zero-heat-flux core body thermometer for hot environments. In this study, we performed a theoretical analysis, designed a prototype probe, and evaluated its performance through simulator experiments with human subjects. The finite element analysis shows that our design can reduce the influence of external temperature variations by as much as 1%. In the simulator experiment, the prototype probe could measure deep temperatures within an error of less than 0.1 \u00b0C, regardless of outside temperature change. In the ergometer experiment with four subjects, the average difference between the prototype probe and a commercial zero-heat-flux probe was +0.1 \u00b0C, with a 95% LOA of \u22120.23 \u00b0C to +0.21 \u00b0C. In the dome sauna test, the results measured in six of the seven subjects exhibited the same trend as the reference temperature. These results show that the newly developed probe with the Peltier module can measure CBT accurately, even when the ambient temperature is higher than CBT up to 42 \u00b0C.<\/jats:p>","DOI":"10.3390\/s23041970","type":"journal-article","created":{"date-parts":[[2023,2,10]],"date-time":"2023-02-10T02:09:59Z","timestamp":1675994999000},"page":"1970","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Development of a Core Body Thermometer Applicable for High-Temperature Environment Based on the Zero-Heat-Flux Method"],"prefix":"10.3390","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3454-5194","authenticated-orcid":false,"given":"Hanzi","family":"Lu","sequence":"first","affiliation":[{"name":"Graduate School of Natural Science & Technology, Kanazawa University, Kanazawa 920-1164, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shun","family":"Aratake","sequence":"additional","affiliation":[{"name":"Graduate School of Natural Science & Technology, Kanazawa University, Kanazawa 920-1164, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9593-1331","authenticated-orcid":false,"given":"Hisashi","family":"Naito","sequence":"additional","affiliation":[{"name":"Institute of Science and Engineering, Kanazawa University, Kanazawa 920-1164, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5555-4225","authenticated-orcid":false,"given":"Masamichi","family":"Nogawa","sequence":"additional","affiliation":[{"name":"Faculty of Health Sciences, Komatsu University, Komatsu 923-0961, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tetsu","family":"Nemoto","sequence":"additional","affiliation":[{"name":"Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa 920-0942, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tatsuo","family":"Togawa","sequence":"additional","affiliation":[{"name":"Advanced Research Center for Human Sciences, Waseda University, Tokorozawa 359-1192, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shinobu","family":"Tanaka","sequence":"additional","affiliation":[{"name":"Institute of Science and Engineering, Kanazawa University, Kanazawa 920-1164, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2023,2,9]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"2449","DOI":"10.1056\/NEJMra1810762","article-title":"Heatstroke","volume":"380","author":"Epstein","year":"2019","journal-title":"N. Engl. J. Med."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Aj\u010devi\u0107, M., Stella, A.B., Furlanis, G., Caruso, P., Naccarato, M., Accardo, A., and Manganotti, P. (2022). A Novel Non-Invasive Thermometer for Continuous Core Body Temperature: Comparison with Tympanic Temperature in an Acute Stroke Clinical Setting. Sensors, 22.","DOI":"10.3390\/s22134760"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1177\/107327481702400212","article-title":"Fever in patients with cancer","volume":"24","author":"Pasikhova","year":"2017","journal-title":"Cancer Control"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.buildenv.2018.12.003","article-title":"Investigation into the thermal comfort of university students conducting outdoor training","volume":"149","author":"Fang","year":"2019","journal-title":"Build. Environ."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"2092","DOI":"10.1111\/sms.14029","article-title":"Apparent temperature and heat-related illnesses during international athletic championships: A prospective cohort study","volume":"31","author":"Hollander","year":"2021","journal-title":"Scand. J. Med. Sci. Sport."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1515\/reveh-2020-0158","article-title":"Heat exposure and workers\u2019 health: A systematic review","volume":"37","author":"Lee","year":"2022","journal-title":"Rev. Environ. Health"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"370","DOI":"10.2486\/indhealth.2018-0063","article-title":"Frequency of firefighters\u2019 heat-related illness and its association with removing personal protective equipment and working hours","volume":"57","author":"Kim","year":"2019","journal-title":"Ind. Health"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Hymczak, H., Go\u0142\u0105b, A., Mendrala, K., Plicner, D., Darocha, T., Podsiad\u0142o, P., Hudziak, D., Goco\u0142, R., and Kosi\u0144ski, S. (2021). Core Temperature Measurement\u2014Principles of Correct Measurement, Problems, and Complications. Int. J. Environ. Res. Public Health, 18.","DOI":"10.3390\/ijerph182010606"},{"key":"ref_9","first-page":"567","article-title":"Comparison of infrared tympanic, non-contact infrared skin, and axillary thermometer to rectal temperature measurements in a pediatric emergency observation unit","volume":"11","author":"Berksoy","year":"2018","journal-title":"Int. J. Clin. Exp. Med."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1158","DOI":"10.1177\/0009922814536774","article-title":"Accuracy of infrared ear thermometry in children: A meta-analysis and systematic review","volume":"53","author":"Zhen","year":"2014","journal-title":"Clin. Pediatr."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Mogensen, C.B., Wittenhoff, L., Fruerh\u00f8j, G., and Hansen, S. (2018). Forehead or ear temperature measurement cannot replace rectal measurements, except for screening purposes. BMC Pediatr., 18.","DOI":"10.1186\/s12887-018-0994-1"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1016\/j.jsams.2017.06.006","article-title":"Validity and reliability of the myTemp ingestible temperature capsule","volume":"21","author":"Bongers","year":"2018","journal-title":"J. Sci. Med. Sport"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"130","DOI":"10.3389\/fendo.2017.00130","article-title":"Issues in continuous 24-h core body temperature monitoring in humans using an ingestible capsule telemetric sensor","volume":"8","author":"Monnard","year":"2017","journal-title":"Front. Endocrinol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1136\/bjsm.2006.026344","article-title":"The ingestible telemetric body core temperature sensor: A review of validity and exercise applications","volume":"41","author":"Byrne","year":"2007","journal-title":"Br. J. Sports Med."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1109\/MCOM.2014.6917412","article-title":"Toward wearable wireless thermometers for internal body temperature measurements","volume":"52","author":"Popovic","year":"2014","journal-title":"IEEE Commun. Mag."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"e19210","DOI":"10.2196\/19210","article-title":"An innovative wearable device for monitoring continuous body surface temperature (HEARThermo): Instrument validation study","volume":"9","author":"Yeh","year":"2021","journal-title":"JMIR mHealth uHealth"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1042\/cs0440081","article-title":"A new method for monitoring deep body temperature from the skin surface","volume":"44","author":"Fox","year":"1973","journal-title":"Clin. Sci."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1007\/BF02478138","article-title":"A modified internal temperature measurement device","volume":"14","author":"Togwa","year":"1976","journal-title":"Med. Biol. Eng."},{"key":"ref_19","first-page":"261","article-title":"Non-invasive deep body temperature measurement","volume":"1","author":"Togawa","year":"1979","journal-title":"Non-invasive Physiol. Meas."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/0300-9572(79)90015-7","article-title":"Deep temperature monitoring in intensive care","volume":"7","author":"Togawa","year":"1979","journal-title":"Resuscitation"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Togawa, T., Tsuji, T., Nemoto, T., Sankawa, H., Ohata, J., and Miyasaka, K. (1986). Small size zero-heat-flux probe for neonatal body temperature monitoring. Neonatal Physiol. Meas., 7\u201312.","DOI":"10.1016\/B978-0-407-00451-1.50004-7"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"e715","DOI":"10.1097\/CCM.0000000000002317","article-title":"Accuracy of Zero-Heat-Flux Cutaneous Temperature in Intensive Care Adults","volume":"45","author":"Lamarche","year":"2017","journal-title":"Crit. Care Med."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"88","DOI":"10.14326\/abe.7.88","article-title":"Current developments in wearable thermometers","volume":"7","author":"Tamura","year":"2018","journal-title":"Adv. Biomed. Eng."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"644","DOI":"10.1109\/TBME.1979.326548","article-title":"A Zero-Heat-Flow Transducer for Monitoring Perfusion Blood Temperature","volume":"26","author":"Tamura","year":"1979","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_25","unstructured":"Muto, S., Sakai, N., Nogawa, M., Naito, H., Tanaka, S., Nemoto, T., and Togawa, T. (2016, January 29\u201330). Development of a Wearable Body Core Temperature Monitor Preliminary Study for Reduction of Power Consumption. Proceedings of the Joint International Conference of BDAHI2016 and u-Healthcare2016 (BigHealth-2016), Aizu Wakamatsu, Japan."},{"key":"ref_26","unstructured":"Bergman, T.L., Lavine, A.S., Incropera, F.P., and DeWitt, D.P. (2011). Introduction to Heat Transfer, John Wiley & Sons."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"912","DOI":"10.1093\/gerona\/glu224","article-title":"Different physiological and subjective responses to the hyperthermia between young and older adults: Basic study for thermal therapy in cardiovascular diseases","volume":"70","author":"Sawatari","year":"2015","journal-title":"J. Gerontol.\u2014Ser. A Biol. Sci. Med. Sci."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"708","DOI":"10.1109\/JBHI.2016.2532933","article-title":"A Wearable Thermometry for Core Body Temperature Measurement and Its Experimental Verification","volume":"21","author":"Huang","year":"2017","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/j.jtherbio.2014.10.006","article-title":"Considerations for the measurement of core, skin and mean body temperatures","volume":"46","author":"Taylor","year":"2014","journal-title":"J. Therm. Biol."},{"key":"ref_30","first-page":"301","article-title":"Deep body thermometer without heating element","volume":"25","author":"Togawa","year":"1987","journal-title":"Jap. J. Med. Biol. Eng."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/4\/1970\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T18:29:31Z","timestamp":1760120971000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/4\/1970"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2,9]]},"references-count":30,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2023,2]]}},"alternative-id":["s23041970"],"URL":"https:\/\/doi.org\/10.3390\/s23041970","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2023,2,9]]}}}