{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,5]],"date-time":"2025-11-05T14:35:05Z","timestamp":1762353305732,"version":"build-2065373602"},"reference-count":19,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2023,2,10]],"date-time":"2023-02-10T00:00:00Z","timestamp":1675987200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"PPP Allowance"},{"name":"Smith and Nephew, Hoofddorp"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Different methods exist to select strides that represent preferred, steady-state gait. The aim of this study was to identify the effect of different stride-selection methods on spatiotemporal gait parameters to analyze steady-state gait. A total of 191 patients with hip or knee osteoarthritis (aged 38\u201385) wearing inertial sensors walked back and forth over 10 m for two minutes. After the removal of strides in turns, five stride-selection methods were compared: (ALL) include all strides, others removed (REFERENCE) two strides around turns, (ONE) one stride around turns, (LENGTH) strides &lt;63% of median stride length, and (SPEED) strides that fall outside the 95% confidence interval of gait speed over the strides included in REFERENCE. Means and SDs of gait parameters were compared for each trial against the most conservative definition (REFERENCE). ONE and SPEED definitions resulted in similar means and SDs compared to REFERENCE, while ALL and LENGTH definitions resulted in substantially higher SDs of all gait parameters. An in-depth analysis of individual strides showed that the first two strides after and last two strides before a turn were significantly different from steady-state walking. Therefore, it is suggested to exclude the first two strides around turns to assess steady-state gait.<\/jats:p>","DOI":"10.3390\/s23042002","type":"journal-article","created":{"date-parts":[[2023,2,10]],"date-time":"2023-02-10T05:51:06Z","timestamp":1676008266000},"page":"2002","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["The Influence of Stride Selection on Gait Parameters Collected with Inertial Sensors"],"prefix":"10.3390","volume":"23","author":[{"given":"Carmen J.","family":"Ensink","sequence":"first","affiliation":[{"name":"Department of Research, Sint Maartenskliniek, 6500 GM Nijmegen, The Netherlands"},{"name":"Department of Sensorimotor Neuroscience, Donders Institute for Brain, Cognition and Behaviour, Radboud University, 6500 HB Nijmegen, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katrijn","family":"Smulders","sequence":"additional","affiliation":[{"name":"Department of Research, Sint Maartenskliniek, 6500 GM Nijmegen, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jolien J. E.","family":"Warnar","sequence":"additional","affiliation":[{"name":"Department of Research, Sint Maartenskliniek, 6500 GM Nijmegen, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"No\u00ebl L. W.","family":"Keijsers","sequence":"additional","affiliation":[{"name":"Department of Research, Sint Maartenskliniek, 6500 GM Nijmegen, The Netherlands"},{"name":"Department of Sensorimotor Neuroscience, Donders Institute for Brain, Cognition and Behaviour, Radboud University, 6500 HB Nijmegen, The Netherlands"},{"name":"Department of Rehabilitation, Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Center, 6500 HB Nijmegen, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2023,2,10]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Shafrin, J., Sullivan, J., Goldman, D.P., and Gill, T.M. (2017). The Association between Observed Mobility and Quality of Life in the near Elderly. PLoS ONE, 12.","DOI":"10.1371\/journal.pone.0182920"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.gaitpost.2004.06.009","article-title":"Gait Differences between Individuals with Post-Stroke Hemiparesis and Non-Disabled Controls at Matched Speeds","volume":"22","author":"Chen","year":"2005","journal-title":"Gait Posture"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"742","DOI":"10.1177\/1545968313491004","article-title":"Does the Evaluation of Gait Quality during Daily Life Provide Insight into Fall Risk? A Novel Approach Using 3-Day Accelerometer Recordings","volume":"27","author":"Weiss","year":"2013","journal-title":"Neurorehabilit. Neural Repair"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"435","DOI":"10.3389\/fnagi.2018.00435","article-title":"Less Is More\u2014Estimation of the Number of Strides Required to Assess Gait Variability in Spatially Confined Settings","volume":"11","author":"Kroneberg","year":"2019","journal-title":"Front. Aging Neurosci."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"90","DOI":"10.3389\/fphys.2020.00090","article-title":"Wearable Inertial Measurement Units for Assessing Gait in Real-World Environments","volume":"11","author":"Renggli","year":"2020","journal-title":"Front. Physiol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1186\/1743-0003-11-152","article-title":"Della Estimation of Step-by-Step Spatio-Temporal Parameters of Normal and Impaired Gait Using Shank-Mounted Magneto-Inertial Sensors: Application to Elderly, Hemiparetic, Parkinsonian and Choreic Gait","volume":"11","author":"Trojaniello","year":"2014","journal-title":"J. NeuroEng. Rehabil."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Behboodi, A., Zahradka, N., Wright, H., Alesi, J., and Lee, S.C.K. (2019). Real-Time Detection of Seven Phases of Gait in Children with Cerebral Palsy Using Two Gyroscopes. Sensors, 19.","DOI":"10.3390\/s19112517"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"911","DOI":"10.1080\/0264041031000140383","article-title":"Characteristics of Shock Attenuation during Fatigued Running","volume":"21","author":"Mercer","year":"2003","journal-title":"J. Sports Sci."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1109\/TBME.2004.840727","article-title":"Assessment of Walking Features from Foot Inertial Sensing","volume":"52","author":"Sabatini","year":"2005","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"490","DOI":"10.1016\/j.gaitpost.2013.08.037","article-title":"Gait Initiation: The First Four Steps in Adults Aged 20\u201325 Years, 65\u201379 Years, and 80\u201391 Years","volume":"39","author":"Muir","year":"2014","journal-title":"Gait Posture"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1109\/TBME.2012.2227317","article-title":"On-Shoe Wearable Sensors for Gait and Turning Assessment of Patients with Parkinson\u2019s Disease","volume":"60","author":"Mariani","year":"2013","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Boekesteijn, R.J., Smolders, J.M.H., Busch, V.J.J.F., Geurts, A.C.H., and Smulders, K. (2021). Independent and Sensitive Gait Parameters for Objective Evaluation in Knee and Hip Osteoarthritis Using Wearable Sensors. BMC Musculoskelet. Disord., 22.","DOI":"10.1186\/s12891-021-04074-2"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/j.gaitpost.2007.10.004","article-title":"Quantity versus Quality of Gait and Quality of Life in Patients with Osteoarthritis","volume":"28","author":"Brandes","year":"2008","journal-title":"Gait Posture"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.gaitpost.2017.10.009","article-title":"Accuracy of Three Methods in Gait Event Detection during Overground Running","volume":"59","author":"Mo","year":"2018","journal-title":"Gait Posture"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"356","DOI":"10.3390\/s140100356","article-title":"Continuous Monitoring of Turning in Patients with Movement Disability","volume":"14","author":"Pearson","year":"2013","journal-title":"Sensors"},{"key":"ref_16","unstructured":"Sukumar, P.T. (2010). Enhanced Stance Phase Detection and Extended Kalman Filtering for Strapdown Pedestrian Dead Reckoning. [Master\u2019s Thesis, University of Lancaster]."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Wu, J., Kuruvithadam, K., Schaer, A., Stoneham, R., Chatzipirpiridis, G., Easthope, C.A., Barry, G., Martin, J., Pan\u00e9, S., and Nelson, B.J. (2021). An Intelligent In-Shoe System for Gait Monitoring and Analysis with Optimized Sampling and Real-Time Visualization Capabilities. Sensors, 21.","DOI":"10.20944\/preprints202103.0616.v1"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"2255","DOI":"10.1109\/TNSRE.2020.3018158","article-title":"Portable Gait Lab: Tracking Relative Distances of Feet and CoM Using Three IMUs","volume":"28","author":"Buurke","year":"2020","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1038\/s41592-019-0470-3","article-title":"Moving beyond P Values: Data Analysis with Estimation Graphics","volume":"16","author":"Ho","year":"2019","journal-title":"Nat. Methods"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/4\/2002\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T18:30:20Z","timestamp":1760121020000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/4\/2002"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2,10]]},"references-count":19,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2023,2]]}},"alternative-id":["s23042002"],"URL":"https:\/\/doi.org\/10.3390\/s23042002","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2023,2,10]]}}}