{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,31]],"date-time":"2026-01-31T03:58:21Z","timestamp":1769831901333,"version":"3.49.0"},"reference-count":18,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2023,2,24]],"date-time":"2023-02-24T00:00:00Z","timestamp":1677196800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"HUMAN ANALYTICS, S.L.","award":["FUO-21-302"],"award-info":[{"award-number":["FUO-21-302"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Ground contact time (GCT) is one of the most relevant factors when assessing running performance in sports practice. In recent years, inertial measurement units (IMUs) have been widely used to automatically evaluate GCT, since they can be used in field conditions and are friendly and easy to wear devices. In this paper we describe the results of a systematic search, using the Web of Science, to assess what reliable options are available to GCT estimation using inertial sensors. Our analysis reveals that estimation of GCT from the upper body (upper back and upper arm) has rarely been addressed. Proper estimation of GCT from these locations could permit an extension of the analysis of running performance to the public, where users, especially vocational runners, usually wear pockets that are ideal to hold sensing devices fitted with inertial sensors (or even using their own cell phones for that purpose). Therefore, in the second part of the paper, an experimental study is described. Six subjects, both amateur and semi-elite runners, were recruited for the experiments, and ran on a treadmill at different paces to estimate GCT from inertial sensors placed at the foot (for validation purposes), the upper arm, and upper back. Initial and final foot contact events were identified in these signals to estimate the GCT per step, and compared to times estimated from an optical MOCAP (Optitrack), used as the ground truth. We found an average error in GCT estimation of 0.01 s in absolute value using the foot and the upper back IMU, and of 0.05 s using the upper arm IMU. Limits of agreement (LoA, 1.96 times the standard deviation) were [\u22120.01 s, 0.04 s], [\u22120.04 s, 0.02 s], and [0.0 s, 0.1 s] using the sensors on the foot, the upper back, and the upper arm, respectively.<\/jats:p>","DOI":"10.3390\/s23052523","type":"journal-article","created":{"date-parts":[[2023,2,24]],"date-time":"2023-02-24T03:57:35Z","timestamp":1677211055000},"page":"2523","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Estimation of Ground Contact Time with Inertial Sensors from the Upper Arm and the Upper Back"],"prefix":"10.3390","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1605-7998","authenticated-orcid":false,"given":"Leticia","family":"Gonz\u00e1lez","sequence":"first","affiliation":[{"name":"Electrical Engineering Department, Campus of Gijon, University of Oviedo, 33204 Oviedo, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5589-6954","authenticated-orcid":false,"given":"Antonio M.","family":"L\u00f3pez","sequence":"additional","affiliation":[{"name":"Electrical Engineering Department, Campus of Gijon, University of Oviedo, 33204 Oviedo, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0395-2712","authenticated-orcid":false,"given":"Diego","family":"\u00c1lvarez","sequence":"additional","affiliation":[{"name":"Electrical Engineering Department, Campus of Gijon, University of Oviedo, 33204 Oviedo, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8910-4855","authenticated-orcid":false,"given":"Juan C.","family":"\u00c1lvarez","sequence":"additional","affiliation":[{"name":"Electrical Engineering Department, Campus of Gijon, University of Oviedo, 33204 Oviedo, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2023,2,24]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1016\/j.jsams.2013.05.012","article-title":"The concurrent effects of strike pattern and ground-contact time on running economy","volume":"17","author":"Merni","year":"2014","journal-title":"J. Sci. Med. Sport"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"53","DOI":"10.3389\/fspor.2019.00053","article-title":"Humans Optimize Ground Contact Time and Leg Stiffness to Minimize the Metabolic Cost of Running","volume":"1","author":"Moore","year":"2019","journal-title":"Front. Sport. Act. Living"},{"key":"ref_3","unstructured":"Gouwanda, D., and Senanayake, S.M.N.A. (2008, January 25\u201328). Emerging Trends of Body-Mounted Sensors in Sports and Human Gait Analysis. Proceedings of the 4th Kuala Lumpur International Conference on Biomedical Engineering 2008, Kuala Lumpur, Malaysia."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1016\/j.gaitpost.2009.11.014","article-title":"Real-time gait event detection for normal subjects from lower trunk accelerations","volume":"31","author":"Alvarez","year":"2010","journal-title":"Gait Posture"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1080\/10255842.2014.997718","article-title":"Upper limb joint angle measurement in occupational health","volume":"19","author":"Alvarez","year":"2016","journal-title":"Comput. Methods Biomech. Biomed. Engin."},{"key":"ref_6","first-page":"106","article-title":"Inertial Sensors and Wavelets Analysis as a Tool for Pathological Gait Identification","volume":"Volume 526","author":"Glowinski","year":"2017","journal-title":"Innovations in Biomedical Engineering. Advances in Intelligent Systems and Computing"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"610","DOI":"10.3389\/fphys.2018.00610","article-title":"Accurate Estimation of Running Temporal Parameters Using Foot-Worn Inertial Sensors","volume":"9","author":"Falbriard","year":"2018","journal-title":"Front. Physiol."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Benson, L.C., Clermont, C.A., Watari, R., Exley, T., and Ferber, R. (2019). Automated accelerometer-based gait event detection during multiple running conditions. Sensors, 19.","DOI":"10.3390\/s19071483"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.gaitpost.2017.10.009","article-title":"Accuracy of three methods in gait event detection during overground running","volume":"59","author":"Mo","year":"2018","journal-title":"Gait Posture"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"110880","DOI":"10.1016\/j.jbiomech.2021.110880","article-title":"Foot angular kinematics measured with inertial measurement units: A reliable criterion for real-time gait event detection","volume":"130","author":"Nazarahari","year":"2022","journal-title":"J. Biomech."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1007\/s12283-017-0255-9","article-title":"Estimating running spatial and temporal parameters using an inertial sensor","volume":"21","author":"Chew","year":"2018","journal-title":"Sport. Eng."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Blauberger, P., Horsch, A., and Lames, M. (2021). Detection of ground contact times with inertial sensors in elite 100-m sprints under competitive field conditions. Sensors, 21.","DOI":"10.3390\/s21217331"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1016\/j.gaitpost.2020.06.019","article-title":"Automated gait event detection for a variety of locomotion tasks using a novel gyroscope-based algorithm","volume":"81","author":"Fadillioglu","year":"2020","journal-title":"Gait Posture"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1123","DOI":"10.1016\/j.jbiomech.2011.12.020","article-title":"Estimation of temporal parameters during sprint running using a trunk-mounted inertial measurement unit","volume":"45","author":"Bergamini","year":"2012","journal-title":"J. Biomech."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1123\/jab.2015-0200","article-title":"Validation of a torso-mounted accelerometer for measures of vertical oscillation and ground contact time during treadmill running","volume":"32","author":"Watari","year":"2016","journal-title":"J. Appl. Biomech."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"109768","DOI":"10.1016\/j.jbiomech.2020.109768","article-title":"Foot contact identification using a single triaxial accelerometer during running","volume":"105","author":"Aubol","year":"2020","journal-title":"J. Biomech."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"110419","DOI":"10.1016\/j.jbiomech.2021.110419","article-title":"Detection of foot contact in treadmill running with inertial and optical measurement systems","volume":"121","author":"Reenalda","year":"2021","journal-title":"J. Biomech."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1455","DOI":"10.1519\/JSC.0b013e318269f760","article-title":"Validation of a New Method to Measure Contact and Flight Times During Treadmill Running","volume":"27","author":"Morante","year":"2013","journal-title":"J. Strength Cond. Res."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/5\/2523\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T18:41:23Z","timestamp":1760121683000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/5\/2523"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2,24]]},"references-count":18,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2023,3]]}},"alternative-id":["s23052523"],"URL":"https:\/\/doi.org\/10.3390\/s23052523","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,2,24]]}}}