{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T13:57:06Z","timestamp":1789567026029,"version":"build-2803163510"},"reference-count":109,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2023,3,10]],"date-time":"2023-03-10T00:00:00Z","timestamp":1678406400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Carl-Zeiss-Foundation"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Exoskeletons are a promising tool to support individuals with a decreased level of motor performance. Due to their built-in sensors, exoskeletons offer the possibility of continuously recording and assessing user data, for example, related to motor performance. The aim of this article is to provide an overview of studies that rely on using exoskeletons to measure motor performance. Therefore, we conducted a systematic literature review, following the PRISMA Statement guidelines. A total of 49 studies using lower limb exoskeletons for the assessment of human motor performance were included. Of these, 19 studies were validity studies, and six were reliability studies. We found 33 different exoskeletons; seven can be considered stationary, and 26 were mobile exoskeletons. The majority of the studies measured parameters such as range of motion, muscle strength, gait parameters, spasticity, and proprioception. We conclude that exoskeletons can be used to measure a wide range of motor performance parameters through built-in sensors, and seem to be more objective and specific than manual test procedures. However, since these parameters are usually estimated from built-in sensor data, the quality and specificity of an exoskeleton to assess certain motor performance parameters must be examined before an exoskeleton can be used, for example, in a research or clinical setting.<\/jats:p>","DOI":"10.3390\/s23063032","type":"journal-article","created":{"date-parts":[[2023,3,13]],"date-time":"2023-03-13T03:28:33Z","timestamp":1678678113000},"page":"3032","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":24,"title":["Use of Lower Limb Exoskeletons as an Assessment Tool for Human Motor Performance: A Systematic Review"],"prefix":"10.3390","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0454-4833","authenticated-orcid":false,"given":"Tobias","family":"Moeller","sequence":"first","affiliation":[{"name":"Institute of Sports and Sports Science, Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Felix","family":"Moehler","sequence":"additional","affiliation":[{"name":"Institute of Sports and Sports Science, Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Janina","family":"Krell-Roesch","sequence":"additional","affiliation":[{"name":"Institute of Sports and Sports Science, Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7160-749X","authenticated-orcid":false,"given":"Miha","family":"De\u017eman","sequence":"additional","affiliation":[{"name":"Institute for Anthropomatics and Robotics, High Performance Humanoid Technologies (H2T), Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5757-1512","authenticated-orcid":false,"given":"Charlotte","family":"Marquardt","sequence":"additional","affiliation":[{"name":"Institute for Anthropomatics and Robotics, High Performance Humanoid Technologies (H2T), Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4879-7680","authenticated-orcid":false,"given":"Tamim","family":"Asfour","sequence":"additional","affiliation":[{"name":"Institute for Anthropomatics and Robotics, High Performance Humanoid Technologies (H2T), Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7885-7085","authenticated-orcid":false,"given":"Thorsten","family":"Stein","sequence":"additional","affiliation":[{"name":"Institute of Sports and Sports Science, Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5736-2980","authenticated-orcid":false,"given":"Alexander","family":"Woll","sequence":"additional","affiliation":[{"name":"Institute of Sports and Sports Science, Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,3,10]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"863","DOI":"10.2165\/00007256-200131120-00003","article-title":"Musculoskeletal fitness, health outcomes and quality of life","volume":"31","author":"Kell","year":"2001","journal-title":"Sport. Med."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1161\/01.CIR.0000048893.62841.F7","article-title":"Arterial and cardiac aging: Major shareholders in cardiovascular disease enterprises: Part II: The aging heart in health: Links to heart disease","volume":"107","author":"Lakatta","year":"2003","journal-title":"Circulation"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"708","DOI":"10.1007\/s12603-009-0201-z","article-title":"Epidemiology and consequences of sarcopenia","volume":"13","year":"2009","journal-title":"J. Nutr. Health Aging"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"743843","DOI":"10.1155\/2013\/743843","article-title":"Flexibility of older adults aged 55\u201386 years and the influence of physical activity","volume":"2013","author":"Stathokostas","year":"2013","journal-title":"J. Aging Res."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"260","DOI":"10.3389\/fphys.2012.00260","article-title":"Sarcopenia, dynapenia, and the impact of advancing age on human skeletal muscle size and strength; a quantitative review","volume":"3","author":"Mitchell","year":"2012","journal-title":"Front. Physiol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1097\/00003677-200304000-00009","article-title":"Toward a better understanding of gait changes with age and disablement: Neuromuscular adaptation","volume":"31","author":"McGibbon","year":"2003","journal-title":"Exerc. Sport Sci. Rev."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1159\/000322196","article-title":"Age-related effects on postural control under multi-task conditions","volume":"57","author":"Granacher","year":"2011","journal-title":"Gerontology"},{"key":"ref_8","unstructured":"Brault, M.W. (2022, January 12). Americans with Disabilities: 2010: Household Economic Studies. Washington, Available online: https:\/\/www2.census.gov\/library\/publications\/2012\/demo\/p70-131.pdf."},{"key":"ref_9","unstructured":"Wheelchair Foundation (2022, January 24). Worldwide Need\u2014Wheelchair Foundation. Available online: https:\/\/www.wheelchairfoundation.org\/fth\/analysis-of-wheelchair-need\/."},{"key":"ref_10","unstructured":"World Health Organization, The World Bank (2011). World Report on Disability 2011F, WHO."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1186\/s12984-020-00663-9","article-title":"The exoskeleton expansion: Improving walking and running economy","volume":"17","author":"Sawicki","year":"2020","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1007\/s12178-020-09610-6","article-title":"How New Technology Is Improving Physical Therapy","volume":"13","author":"Owens","year":"2020","journal-title":"Curr. Rev. Musculoskelet. Med."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1108\/IR-08-2014-0379","article-title":"Robotic exoskeletons: A review of recent progress","volume":"42","author":"Bogue","year":"2015","journal-title":"Ind. Robot. Int. J. Robot. Res. Appl."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1491","DOI":"10.1007\/s12541-012-0197-x","article-title":"The technical trend of the exoskeleton robot system for human power assistance","volume":"13","author":"Lee","year":"2012","journal-title":"Int. J. Precis. Eng. Manuf."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1186\/s12984-021-00906-3","article-title":"Review of control strategies for lower-limb exoskeletons to assist gait","volume":"18","author":"Baud","year":"2021","journal-title":"J. Neuroeng. Rehabil"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Ne\u0165ukov\u00e1, S., Bejtic, M., Mal\u00e1, C., Hor\u00e1kov\u00e1, L., Kut\u00edlek, P., Kauler, J., and Krupi\u010dka, R. (2022). Lower Limb Exoskeleton Sensors: State-of-the-Art. Sensors, 22.","DOI":"10.3390\/s22239091"},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Tiboni, M., Borboni, A., V\u00e9rit\u00e9, F., Bregoli, C., and Amici, C. (2022). Sensors and Actuation Technologies in Exoskeletons: A Review. Sensors, 22.","DOI":"10.3390\/s22030884"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/j.arcontrol.2022.04.003","article-title":"From sensing to control of lower limb exoskeleton: A systematic review","volume":"53","author":"Sun","year":"2022","journal-title":"Annu. Rev. Control"},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Duncan, E.A.S., and Murray, J. (2012). The barriers and facilitators to routine outcome measurement by allied health professionals in practice: A systematic review. BMC Health Serv. Res., 12.","DOI":"10.1186\/1472-6963-12-96"},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Li, X., Dunn, J., Salins, D., Zhou, G., Zhou, W., Sch\u00fcssler-Fiorenza Rose, S.M., Perelman, D., Colbert, E., Runge, R., and Rego, S. (2017). Digital Health: Tracking Physiomes and Activity Using Wearable Biosensors Reveals Useful Health-Related Information. PLoS Biol., 15.","DOI":"10.1371\/journal.pbio.2001402"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Mittelmark, M.B., and Bauer, G.F. (2017). The Handbook of Salutogenesis, Springer.","DOI":"10.1007\/978-3-319-04600-6"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1753944720931637","DOI":"10.1177\/1753944720931637","article-title":"Current status of white coat hypertension: Where are we?","volume":"14","author":"Nuredini","year":"2020","journal-title":"Ther. Adv. Cardiovasc. Dis."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"429","DOI":"10.2217\/pme-2018-0044","article-title":"Wearables and the medical revolution","volume":"15","author":"Dunn","year":"2018","journal-title":"Per. Med."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"de Angelis, M., Lavorgna, L., Carotenuto, A., Petruzzo, M., Lanzillo, R., Brescia Morra, V., and Moccia, M. (2021). Digital Technology in Clinical Trials for Multiple Sclerosis: Systematic Review. J. Clin. Med., 10.","DOI":"10.3390\/jcm10112328"},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Taborri, J., Pasinetti, S., Cardinali, L., Perroni, F., and Rossi, S. (2021). Preventing and Monitoring Work-Related Diseases in Firefighters: A Literature Review on Sensor-Based Systems and Future Perspectives in Robotic Devices. Int. J. Environ. Res. Public Health, 18.","DOI":"10.3390\/ijerph18189723"},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Reinkensmeyer, D.J., and Dietz, V. (2016). Neurorehabilitation Technology, Springer International Publishing. [2nd ed.].","DOI":"10.1007\/978-3-319-28603-7"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"S255","DOI":"10.1097\/PHM.0b013e31826bcdc1","article-title":"Robotic assessment of upper limb motor function after stroke","volume":"91","author":"Balasubramanian","year":"2012","journal-title":"Am. J. Phys. Med. Rehabil."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"10804","DOI":"10.1115\/1.4039145","article-title":"A Review of Intent Detection, Arbitration, and Communication Aspects of Shared Control for Physical Human\u2013Robot Interaction","volume":"70","author":"Losey","year":"2018","journal-title":"Appl. Mech. Rev."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1186\/s12984-016-0180-3","article-title":"Robot-aided assessment of lower extremity functions: A review","volume":"13","author":"Maggioni","year":"2016","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1186\/s12984-017-0273-7","article-title":"Robot-supported assessment of balance in standing and walking","volume":"14","author":"Shirota","year":"2017","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1186\/s12984-017-0314-2","article-title":"Robot-assisted assessment of muscle strength","volume":"14","author":"Toigo","year":"2017","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1179572720979013","DOI":"10.1177\/1179572720979013","article-title":"Tools and Techniques Used with Robotic Devices to Quantify Upper-Limb Function in Typically Developing Children: A Systematic Review","volume":"9","author":"Dobri","year":"2020","journal-title":"Rehabil. Process Outcome"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"n71","DOI":"10.1136\/bmj.n71","article-title":"The PRISMA 2020 statement: An updated guideline for reporting systematic reviews","volume":"372","author":"Page","year":"2021","journal-title":"BMJ"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"A12","DOI":"10.7326\/ACPJC-1995-123-3-A12","article-title":"The well-built clinical question: A key to evidence-based decisions","volume":"123","author":"Richardson","year":"1995","journal-title":"ACP J. Club"},{"key":"ref_35","unstructured":"National Heart, Lung and Blood Institute (2022, March 20). Study Quality Assessment Tools, Available online: https:\/\/www.nhlbi.nih.gov\/health-topics\/study-quality-assessment-tools."},{"key":"ref_36","unstructured":"Lunenburger, L., Colombo, G., Riener, R., and Dietz, V. (July, January 28). Clinical Assessments Performed During Robotic Rehabilitation by the Gait Training Robot Lokomat. Proceedings of the 2005 IEEE 9th International Conference on Rehabilitation Robotics, Chicago, IL, USA."},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Chaparro-Rico, B.D.M., Cafolla, D., Tortola, P., and Galardi, G. (2020). Assessing Stiffness, Joint Torque and ROM for Paretic and Non-Paretic Lower Limbs during the Subacute Phase of Stroke Using Lokomat Tools. Appl. Sci., 10.","DOI":"10.3390\/app10186168"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"4729","DOI":"10.1109\/JSEN.2023.3237130","article-title":"Parametric and Noise Effects on Magnetic Sensing System for Monitoring Human-Joint Motion of Lower Extremity in Sagittal Plane","volume":"23","author":"Hu","year":"2023","journal-title":"IEEE Sens. J."},{"key":"ref_39","first-page":"1","article-title":"Optimized hip-knee-ankle exoskeleton assistance at a range of walking speeds","volume":"18","author":"Bryan","year":"2021","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1109\/TNSRE.2007.903930","article-title":"Assessment of motion of a swing leg and gait rehabilitation with a gravity balancing exoskeleton","volume":"15","author":"Agrawal","year":"2007","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"1228","DOI":"10.1109\/TRO.2006.882928","article-title":"Gravity-Balancing Leg Orthosis and Its Performance Evaluation","volume":"22","author":"Banala","year":"2006","journal-title":"IEEE Trans. Rob."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1109\/TNSRE.2007.903919","article-title":"Design and evaluation of the LOPES exoskeleton robot for interactive gait rehabilitation","volume":"15","author":"Veneman","year":"2007","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"3314","DOI":"10.1109\/TBME.2013.2267741","article-title":"Active and Progressive Exoskeleton Rehabilitation Using Multisource Information Fusion from EMG and Force-Position EPP","volume":"60","author":"Fan","year":"2013","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"e30","DOI":"10.1017\/wtc.2022.29","article-title":"An algorithm to reduce human-robot interface compliance errors in posture estimation in wearable robots","volume":"3","author":"Koginov","year":"2022","journal-title":"Wearable Technol."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"103842","DOI":"10.1016\/j.robot.2021.103842","article-title":"An adaptive framework of real-time continuous gait phase variable estimation for lower-limb wearable robots","volume":"143","author":"Zhang","year":"2021","journal-title":"Robot. Amd. Auton. Syst."},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"Molinaro, D.D., Kang, I., Camargo, J., and Young, A.J. (December, January 29). Biological Hip Torque Estimation using a Robotic Hip Exoskeleton. Proceedings of the 2020 8th IEEE RAS\/EMBS International Conference for Biomedical Robotics and Biomechatronics (BioRob), New York, NY, USA.","DOI":"10.1109\/BioRob49111.2020.9224334"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1186\/s12984-017-0237-y","article-title":"Physical human-robot interaction of an active pelvis orthosis: Toward ergonomic assessment of wearable robots","volume":"14","author":"Vanetti","year":"2017","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1186\/s12984-015-0062-0","article-title":"Effects of a wearable exoskeleton stride management assist system (SMA\u00ae) on spatiotemporal gait characteristics in individuals after stroke: A randomized controlled trial","volume":"12","author":"Buesing","year":"2015","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_49","doi-asserted-by":"crossref","unstructured":"Pinheiro, C., Figueiredo, J., Magalhaes, N., and Santos, C.P. (2020). Wearable Biofeedback Improves Human-Robot Compliance during Ankle-Foot Exoskeleton-Assisted Gait Training: A Pre-Post Controlled Study in Healthy Participants. Sensors, 20.","DOI":"10.3390\/s20205876"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"2492","DOI":"10.1109\/TMECH.2017.2761746","article-title":"Instrumented Ankle\u2013Foot Orthosis: Toward a Clinical Assessment Tool for Patient-Specific Optimization of Orthotic Ankle Stiffness","volume":"22","author":"Bolus","year":"2017","journal-title":"IEEE\u2013ASME Trans. Mechatron."},{"key":"ref_51","doi-asserted-by":"crossref","unstructured":"Satici, A.C., Erdogan, A., and Patoglu, V. (2009, January 23\u201326). Design of a reconfigurable ankle rehabilitation robot and its use for the estimation of the ankle impedance. Proceedings of the 2009 IEEE International Conference on Rehabilitation Robotics, ICORR 2009, Kyoto, Japan.","DOI":"10.1109\/ICORR.2009.5209513"},{"key":"ref_52","doi-asserted-by":"crossref","unstructured":"Park, Y.-L., Chen, B., Young, D., Stirling, L., Wood, R.J., Goldfield, E., and Nagpal, R. (2011, January 25\u201330). Bio-inspired active soft orthotic device for ankle foot pathologies. Proceedings of the 2011 IEEE\/RSJ International Conference on Intelligent Robots and Systems, San Francisco, CA, USA.","DOI":"10.1109\/IROS.2011.6094933"},{"key":"ref_53","unstructured":"A\u00edin, G., Barroso, F.A., Moreno, J.C., and Pons, J.L. (2013, January 18\u201320). Assessment of the suitability of the Motorized ankle-foot orthosis as a diagnostic and rehabilitation tool for gait. Proceedings of the NEUROTECHNIX 2013\u2014Proceedings of the International Congress on Neurotechnology, Electronics and Informatics, Vilamoura, Algarve, Portugal."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"1380","DOI":"10.1109\/TRO.2022.3170239","article-title":"Neuromechanical Model-Based Adaptive Control of Bilateral Ankle Exoskeletons: Biological Joint Torque and Electromyogram Reduction Across Walking Conditions","volume":"38","author":"Durandau","year":"2022","journal-title":"IEEE Trans. Rob."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"e14328","DOI":"10.14814\/phy2.14328","article-title":"Ankle proprioception during gait in individuals with incomplete spinal cord injury","volume":"7","author":"Dambreville","year":"2019","journal-title":"Physiol. Rep."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1177\/1545968315591703","article-title":"Quantification of Lower Extremity Kinesthesia Deficits Using a Robotic Exoskeleton in People with a Spinal Cord Injury","volume":"30","author":"Chisholm","year":"2016","journal-title":"Neurorehabil. Neural. Repair."},{"key":"ref_57","first-page":"5975455","article-title":"Quantifying lower limb joint position sense using a robotic exoskeleton: A pilot study","volume":"2011","author":"Domingo","year":"2011","journal-title":"IEEE Int. Conf. Rehabil. Robot."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1186\/1743-0003-11-167","article-title":"Reliability and validity of using the Lokomat to assess lower limb joint position sense in people with incomplete spinal cord injury","volume":"11","author":"Domingo","year":"2014","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_59","unstructured":"Yu, H. (2015, January 11\u201314). Robot-aided assessment of walking function based on an adaptive algorithm. Proceedings of the 2015 IEEE International Conference on Rehabilitation Robotics (ICORR 2015), Singapore."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1186\/s12984-016-0142-9","article-title":"Accelerometry-enabled measurement of walking performance with a robotic exoskeleton: A pilot study","volume":"13","author":"Lonini","year":"2016","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"224071","DOI":"10.1109\/ACCESS.2020.3044255","article-title":"Effects of User Intent Changes on Onboard Sensor Measurements During Exoskeleton-Assisted Walking","volume":"8","author":"Gambon","year":"2020","journal-title":"IEEE Access"},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"27116","DOI":"10.1109\/JSEN.2021.3111212","article-title":"Real-Time Gait Event Detection for a Lower Extremity Exoskeleton Robot by Infrared Distance Sensors","volume":"21","author":"Li","year":"2021","journal-title":"IEEE Sens. J."},{"key":"ref_63","doi-asserted-by":"crossref","unstructured":"Xia, Y., Li, J., Yang, D., and Wei, W. (2023). Gait Phase Classification of Lower Limb Exoskeleton Based on a Compound Network Model. Symmetry, 15.","DOI":"10.3390\/sym15010163"},{"key":"ref_64","doi-asserted-by":"crossref","unstructured":"Kang, I., Kunapuli, P., Hsu, H., and Young, A.J. (2019, January 24\u201328). Electromyography (EMG) Signal Contributions in Speed and Slope Estimation Using Robotic Exoskeletons. Proceedings of the IEEE International Conference on Rehabilitation Robotics (ICORR), Toronto, ON, Canada.","DOI":"10.1109\/ICORR.2019.8779433"},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1109\/TMRB.2019.2961749","article-title":"Real-Time Neural Network-Based Gait Phase Estimation Using a Robotic Hip Exoskeleton","volume":"2","author":"Kang","year":"2020","journal-title":"IEEE Trans. Med. Robot. Bionics"},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"3491","DOI":"10.1109\/LRA.2021.3062562","article-title":"Real-Time Gait Phase Estimation for Robotic Hip Exoskeleton Control During Multimodal Locomotion","volume":"6","author":"Kang","year":"2021","journal-title":"IEEE Robot. Autom."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"16952","DOI":"10.1109\/JSEN.2022.3175823","article-title":"Gait Pattern Identification and Phase Estimation in Continuous Multilocomotion Mode Based on Inertial Measurement Units","volume":"22","author":"Zhang","year":"2022","journal-title":"IEEE Sens. J."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"2227","DOI":"10.1109\/TMECH.2019.2929826","article-title":"Controlling a Robotic Hip Exoskeleton with Noncontact Capacitive Sensors","volume":"24","author":"Crea","year":"2019","journal-title":"IEEE\/ASME Trans. Mechatron."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1109\/TBCAS.2022.3173965","article-title":"Hardware Circuits Design and Performance Evaluation of a Soft Lower Limb Exoskeleton","volume":"16","author":"Cao","year":"2022","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_70","doi-asserted-by":"crossref","unstructured":"Yu, S., Yang, J., Huang, T.-H., Zhu, J., Visco, C.J., Hameed, F., Stein, J., Zhou, X., and Su, H. (2023). Artificial Neural Network-Based Activities Classification, Gait Phase Estimation, and Prediction. Ann. Biomed. Eng.","DOI":"10.1007\/s10439-023-03151-y"},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"287","DOI":"10.3233\/NRE-131042","article-title":"Isometric hip and knee torque measurements as an outcome measure in robot assisted gait training","volume":"34","author":"Galen","year":"2014","journal-title":"NeuroRehabilitation"},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"949","DOI":"10.1016\/j.jbiomech.2014.01.025","article-title":"Evaluation of lower limb cross planar kinetic connectivity signatures post-stroke","volume":"47","author":"Tan","year":"2014","journal-title":"J. Biomech."},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1016\/j.neucli.2018.12.001","article-title":"Reliability of maximum isometric hip and knee torque measurements in children with cerebral palsy using a paediatric exoskeleton\u2014Lokomat","volume":"49","author":"Cherni","year":"2018","journal-title":"Neurophysiol. Clin."},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1186\/1743-0003-5-23","article-title":"Standardized voluntary force measurement in a lower extremity rehabilitation robot","volume":"5","author":"Bolliger","year":"2008","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1161\/STROKEAHA.107.492413","article-title":"Evidence of abnormal lower-limb torque coupling after stroke: An isometric study","volume":"39","author":"Cruz","year":"2008","journal-title":"Stroke"},{"key":"ref_76","doi-asserted-by":"crossref","unstructured":"Rea, R., Beck, C., Rovekamp, R., Diftler, M., and Neuhaus, P. (2013, January 10\u201312). X1: A robotic exoskeleton for in-space countermeasures and dynamometry. Proceedings of the AIAA SPACE 2013 Conference and Exposition, San Diego, CA, USA.","DOI":"10.2514\/6.2013-5510"},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"103667","DOI":"10.1016\/j.robot.2020.103667","article-title":"Assist-As-Needed control of a hip exoskeleton based on a novel strength index","volume":"134","author":"Naghavi","year":"2020","journal-title":"Robot. Amd. Auton. Syst."},{"key":"ref_78","unstructured":"Riener, R., Brunschweiler, A., L\u00fcnenburger, L., and Colombo, G. (2004, January 6\u20139). Robot-supported spasticity evaluation. Proceedings of the 9th Annual Conference of the International FES Society, Bournemouth, UK."},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.1080\/09638288.2019.1646814","article-title":"Intra- and inter-tester reliability of spasticity assessment in standing position in children and adolescents with cerebral palsy using a paediatric exoskeleton","volume":"43","author":"Cherni","year":"2021","journal-title":"Disabil. Rehabil."},{"key":"ref_80","first-page":"3426","article-title":"In vivo measurement of human knee and hip dynamics using MIMO system identification","volume":"2010","author":"Koopman","year":"2010","journal-title":"Annu. Int. Conf. IEEE Eng. Med. Biol. Soc."},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"1491","DOI":"10.1007\/978-3-319-46669-9_244","article-title":"Velocity dependant spasticity detection for active exoskeleton based therapies","volume":"15","author":"Soto","year":"2017","journal-title":"Biosyst. Biorobotics"},{"key":"ref_82","doi-asserted-by":"crossref","first-page":"41005","DOI":"10.1115\/1.4051843","article-title":"Validation of Methods for Estimation of Knee Joint Mechanical Impedance During Locomotion Using a Torque-Controllable Knee Exoskeleton","volume":"144","author":"Nazon","year":"2021","journal-title":"J. Biomech. Eng."},{"key":"ref_83","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1109\/TRO.2009.2019783","article-title":"Robot-Aided Neurorehabilitation: A Novel Robot for Ankle Rehabilitation","volume":"25","author":"Roy","year":"2009","journal-title":"IEEE Trans. Robot."},{"key":"ref_84","doi-asserted-by":"crossref","first-page":"2132","DOI":"10.1152\/jn.01014.2010","article-title":"Measurement of passive ankle stiffness in subjects with chronic hemiparesis using a novel ankle robot","volume":"105","author":"Roy","year":"2011","journal-title":"J. Neurophysiol."},{"key":"ref_85","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1186\/s13643-017-0663-8","article-title":"Evaluations of the uptake and impact of the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) Statement and extensions: A scoping review","volume":"6","author":"Page","year":"2017","journal-title":"Syst. Rev."},{"key":"ref_86","doi-asserted-by":"crossref","unstructured":"Dietz, V., Nef, T., and Rymer, W.Z. (2012). Neurorehabilitation Technology, Springer Limited. [1st ed.].","DOI":"10.1007\/978-1-4471-2277-7"},{"key":"ref_87","doi-asserted-by":"crossref","first-page":"782","DOI":"10.1121\/1.1910407","article-title":"PEST: Efficient Estimates on Probability Functions","volume":"41","author":"Taylor","year":"1967","journal-title":"J. Acoust. Soc. Am."},{"key":"ref_88","doi-asserted-by":"crossref","first-page":"S50","DOI":"10.1080\/10790268.2003.11754575","article-title":"International standards for neurological classification of spinal cord injury","volume":"26","author":"Marino","year":"2003","journal-title":"J. Spinal Cord Med."},{"key":"ref_89","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1186\/s11556-021-00266-w","article-title":"Sensor-based fall risk assessment in older adults with or without cognitive impairment: A systematic review","volume":"18","author":"Bezold","year":"2021","journal-title":"Eur. Rev. Aging Phys. Act."},{"key":"ref_90","doi-asserted-by":"crossref","unstructured":"Ibrahim, H.K., Gabli, M., and Peyrodie, L. (2022, January 1\u20132). Anticipation of falls from a structure for paraplegics by intelligent methods. Proceedings of the 2022 IEEE 3rd International Conference on Electronics, Control, Optimization and Computer Science (ICECOCS), Fez, Morocco, North Africa.","DOI":"10.1109\/ICECOCS55148.2022.9983134"},{"key":"ref_91","doi-asserted-by":"crossref","first-page":"370","DOI":"10.1007\/s42235-021-00146-0","article-title":"Design of a Minimally Actuated Lower Limb Exoskeleton with Mechanical Joint Coupling","volume":"19","author":"Li","year":"2022","journal-title":"J. Bionic. Eng."},{"key":"ref_92","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1123\/jab.2020-0222","article-title":"Estimating Center of Mass Kinematics During Perturbed Human Standing Using Accelerometers","volume":"37","author":"Hnat","year":"2021","journal-title":"J. Appl. Biomech."},{"key":"ref_93","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1002\/cphy.c170043","article-title":"Motor Learning","volume":"9","author":"Krakauer","year":"2019","journal-title":"Compr. Physiol."},{"key":"ref_94","unstructured":"Bartenbach, V. (2017). Constraints Caused by Lower Extremity Exoskeletons. [Ph.D. Thesis, ETH Zurich]."},{"key":"ref_95","doi-asserted-by":"crossref","first-page":"eabf1078","DOI":"10.1126\/scirobotics.abf1078","article-title":"How adaptation, training, and customization contribute to benefits from exoskeleton assistance","volume":"6","author":"Poggensee","year":"2021","journal-title":"Sci. Robot."},{"key":"ref_96","doi-asserted-by":"crossref","unstructured":"Zhou, L., Fischer, E., Tunca, C., Brahms, C.M., Ersoy, C., Granacher, U., and Arnrich, B. (2020). How We Found Our IMU: Guidelines to IMU Selection and a Comparison of Seven IMUs for Pervasive Healthcare Applications. Sensors, 20.","DOI":"10.3390\/s20154090"},{"key":"ref_97","doi-asserted-by":"crossref","unstructured":"Payton, C.J. (2016). Biomechanical Evaluation of Movement in Sport and Exercise: The British Association of Sport and Exercise Sciences Guide, Taylor and Francis. [2nd ed.].","DOI":"10.4324\/9780203095546"},{"key":"ref_98","doi-asserted-by":"crossref","first-page":"702","DOI":"10.1177\/0018720818795064","article-title":"Age-Related Differences in the Relationships Between Lower-Limb Joint Proprioception and Postural Balance","volume":"61","author":"Chen","year":"2019","journal-title":"Hum. Factors"},{"key":"ref_99","doi-asserted-by":"crossref","first-page":"7928","DOI":"10.1109\/LRA.2022.3186066","article-title":"The AGoRA V2 Unilateral Lower-Limb Exoskeleton: Mechatronic Integration and Biomechanical Assessment","volume":"7","author":"Otalora","year":"2022","journal-title":"IEEE Robot. Autom."},{"key":"ref_100","doi-asserted-by":"crossref","first-page":"896","DOI":"10.1093\/gerona\/glp033","article-title":"Quantitative gait markers and incident fall risk in older adults","volume":"64","author":"Verghese","year":"2009","journal-title":"J. Gerontol. A Biol. Sci. Med. Sci."},{"key":"ref_101","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1016\/j.pmr.2012.11.007","article-title":"Gait analysis for poststroke rehabilitation: The relevance of biomechanical analysis and the impact of gait speed","volume":"24","author":"Nadeau","year":"2013","journal-title":"Phys. Med. Rehabil. Clin. N. Am."},{"key":"ref_102","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/j.jbiomech.2018.12.006","article-title":"Influence of signal filtering and sample rate on isometric torque\u2014Time parameters using a traditional isokinetic dynamometer","volume":"83","author":"Thompson","year":"2019","journal-title":"J. Biomech."},{"key":"ref_103","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1186\/s12984-022-00996-7","article-title":"The diagnostic levels of evidence of instrumented devices for measuring viscoelastic joint properties and spasticity; a systematic review","volume":"19","author":"Ribbers","year":"2022","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_104","doi-asserted-by":"crossref","unstructured":"Scataglini, S., Imbesi, S., and Marques, G. (2022). Internet of Things for Human-Centered Design: Application to Elderly Healthcare, Springer. [1st ed.].","DOI":"10.1007\/978-981-16-8488-3"},{"key":"ref_105","doi-asserted-by":"crossref","first-page":"858893","DOI":"10.3389\/frobt.2022.858893","article-title":"Effects of Upper-Limb Exoskeletons Designed for Use in the Working Environment-A Literature Review","volume":"9","author":"Moeller","year":"2022","journal-title":"Front. Robot. AI"},{"key":"ref_106","doi-asserted-by":"crossref","unstructured":"Gao, M., Wang, Z., Pang, Z., Sun, J., Li, J., Li, S., and Zhang, H. (2022). Electrically Driven Lower Limb Exoskeleton Rehabilitation Robot Based on Anthropomorphic Design. Machines, 10.","DOI":"10.3390\/machines10040266"},{"key":"ref_107","doi-asserted-by":"crossref","first-page":"22","DOI":"10.3389\/fspor.2019.00022","article-title":"Does a Passive Unilateral Lower Limb Exoskeleton Affect Human Static and Dynamic Balance Control?","volume":"1","author":"Ringhof","year":"2019","journal-title":"Front. Sport. Act. Living"},{"key":"ref_108","doi-asserted-by":"crossref","unstructured":"Dietz, V., Nef, T., and Rymer, W.Z. (2012). Neurorehabilitation Technology, Springer Limited. [1st ed.].","DOI":"10.1007\/978-1-4471-2277-7"},{"key":"ref_109","unstructured":"United Nations (2017). World Population Ageing: 2017 Highlights, United Nations."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/6\/3032\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T18:52:30Z","timestamp":1760122350000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/6\/3032"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,10]]},"references-count":109,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2023,3]]}},"alternative-id":["s23063032"],"URL":"https:\/\/doi.org\/10.3390\/s23063032","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,10]]}}}