{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,20]],"date-time":"2026-05-20T15:05:56Z","timestamp":1779289556986,"version":"3.51.4"},"reference-count":77,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2023,3,24]],"date-time":"2023-03-24T00:00:00Z","timestamp":1679616000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Vice-rectory for Research and Development (VRID) of the Universidad de Concepci\u00f3n","award":["220.092.003-M"],"award-info":[{"award-number":["220.092.003-M"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The Timed Up and Go (TUG) test is a widely used tool for assessing the risk of falls in older adults. However, to increase the test\u2019s predictive value, the instrumented Timed Up and Go (iTUG) test has been developed, incorporating different technological approaches. This systematic review aims to explore the evidence of the technological proposal for the segmentation and analysis of iTUG in elderlies with or without pathologies. A search was conducted in five major databases, following PRISMA guidelines. The review included 40 studies that met the eligibility criteria. The most used technology was inertial sensors (75% of the studies), with healthy elderlies (35%) and elderlies with Parkinson\u2019s disease (32.5%) being the most analyzed participants. In total, 97.5% of the studies applied automatic segmentation using rule-based algorithms. The iTUG test offers an economical and accessible alternative to increase the predictive value of TUG, identifying different variables, and can be used in clinical, community, and home settings.<\/jats:p>","DOI":"10.3390\/s23073426","type":"journal-article","created":{"date-parts":[[2023,3,24]],"date-time":"2023-03-24T06:34:07Z","timestamp":1679639647000},"page":"3426","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":106,"title":["Instrumented Timed Up and Go Test (iTUG)\u2014More Than Assessing Time to Predict Falls: A Systematic Review"],"prefix":"10.3390","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9333-3036","authenticated-orcid":false,"given":"Paulina","family":"Ortega-Bastidas","sequence":"first","affiliation":[{"name":"Health Sciences PhD Programme, International Doctoral School, Universidad Rey Juan Carlos, 28922 Madrid, Spain"},{"name":"Kinesiology Department, Faculty of Medicine, Universidad de Concepci\u00f3n, Concepci\u00f3n, 151 Janequeo St., Concepcion 4030000, Chile"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6563-2955","authenticated-orcid":false,"given":"Britam","family":"G\u00f3mez","sequence":"additional","affiliation":[{"name":"Biomedical Engineering, Faculty of Engineering, Universidad de Santiago de Chile, Libertador Bernardo O\u2019Higgins Av., Santiago 9170022, Chile"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9101-0383","authenticated-orcid":false,"given":"Pablo","family":"Aqueveque","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Faculty of Engineering, Universidad de Concepci\u00f3n, 219 Edmundo Larenas St., Concepci\u00f3n 4030000, Chile"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3429-6412","authenticated-orcid":false,"given":"Soledad","family":"Luarte-Mart\u00ednez","sequence":"additional","affiliation":[{"name":"Kinesiology Department, Faculty of Medicine, Universidad de Concepci\u00f3n, Concepci\u00f3n, 151 Janequeo St., Concepcion 4030000, Chile"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1118-4234","authenticated-orcid":false,"given":"Roberto","family":"Cano-de-la-Cuerda","sequence":"additional","affiliation":[{"name":"Physiotherapy, Occupational Therapy, Rehabilitation and Physical Medicine Department, Universidad Rey Juan Carlos, 28922 Madrid, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2023,3,24]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1206","DOI":"10.18549\/PharmPract.2018.03.1206","article-title":"Falls in the elderly: Assessment of prevalence and risk factors","volume":"16","author":"Sharif","year":"2018","journal-title":"Pharm. Pract. (Granada)"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"111612","DOI":"10.1016\/j.exger.2021.111612","article-title":"Visual-related training to improve balance and walking ability in older adults: A systematic review","volume":"156","author":"Mak","year":"2021","journal-title":"Exp. Gerontol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"ITC81","DOI":"10.7326\/AITC201812040","article-title":"Fall prevention in community-dwelling older adults","volume":"169","author":"Phelan","year":"2018","journal-title":"Ann. Intern. Med."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.maturitas.2013.02.009","article-title":"Risk factors for falls among older adults: A review of the literature","volume":"75","author":"Ambrose","year":"2013","journal-title":"Maturitas"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s40520-017-0749-0","article-title":"Tools for assessing fall risk in the elderly: A systematic review and meta-analysis","volume":"30","author":"Park","year":"2018","journal-title":"Aging Clin. Exp. Res."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.clinbiomech.2018.08.006","article-title":"Is it possible to predict falls in older adults using gait kinematics?","volume":"59","author":"Marques","year":"2018","journal-title":"Clin. Biomech."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1471-2318-13-105","article-title":"A best practice fall prevention exercise program to improve balance, strength\/power, and psychosocial health in older adults: Study protocol for a randomized controlled trial","volume":"13","author":"Gschwind","year":"2013","journal-title":"BMC Geriatr."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1471-2318-14-14","article-title":"Is the Timed Up and Go test a useful predictor of risk of falls in community dwelling older adults: A systematic review and meta-analysis","volume":"14","author":"Barry","year":"2014","journal-title":"BMC Geriatr."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1289","DOI":"10.2147\/CIA.S86001","article-title":"Assessment of the risk of falling with the use of timed up and go test in the elderly with lower extremity osteoarthritis","volume":"10","author":"Zasadzka","year":"2015","journal-title":"Clin. Interv. Aging"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1743-0003-11-83","article-title":"Timed Up & Go as a measure for longitudinal change in mobility after stroke\u2013Postural Stroke Study in Gothenburg (POSTGOT)","volume":"11","author":"Persson","year":"2014","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12984-017-0241-2","article-title":"Auto detection and segmentation of daily living activities during a Timed Up and Go task in people with Parkinson\u2019s disease using multiple inertial sensors","volume":"14","author":"Nguyen","year":"2017","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1111\/j.1532-5415.1991.tb01616.x","article-title":"The timed \u201cUp & Go\u201d: A test of basic functional mobility for frail elderly persons","volume":"39","author":"Podsiadlo","year":"1991","journal-title":"J. Am. Geriatr. Soc."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Vervoort, D., Vuillerme, N., Kosse, N., Hortob\u00e1gyi, T., and Lamoth, C.J. (2016). Multivariate analyses and classification of inertial sensor data to identify aging effects on the Timed-Up-and-Go Test. PLoS ONE, 11.","DOI":"10.1371\/journal.pone.0155984"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"39","DOI":"10.4067\/S0034-98872015000100005","article-title":"Rendimiento en las pruebas \u201cTimed Up and Go\u201d y \u201cEstaci\u00f3n Unipodal\u201d en adultos mayores chilenos entre 60 y 89 a\u00f1os","volume":"143","author":"Mancilla","year":"2015","journal-title":"Rev. M\u00e9d. Chile"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1080\/16501970410017215","article-title":"Reliability of gait performance tests in men and women with hemiparesis after stroke","volume":"37","author":"Flansbjer","year":"2005","journal-title":"J. Rehabil. Med."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1310\/tsr2103-197","article-title":"Clinimetric properties of the Timed Up and Go Test for patients with stroke: A systematic review","volume":"21","author":"Hafsteinsdottir","year":"2014","journal-title":"Top. Stroke Rehabil."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"47","DOI":"10.3138\/ptc.2009-08","article-title":"Psychometric properties of activity, self-efficacy, and quality-of-life measures in individuals with Parkinson disease","volume":"63","author":"Klassen","year":"2011","journal-title":"Physiother. Can."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Van Lummel, R.C., Walgaard, S., Hobert, M.A., Maetzler, W., Van Die\u00ebn, J.H., Galindo-Garre, F., and Terwee, C.B. (2016). Intra-rater, inter-rater and test-retest reliability of an instrumented timed up and go (iTUG) test in patients with Parkinson\u2019s disease. PLoS ONE, 11.","DOI":"10.1371\/journal.pone.0151881"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1109\/TNSRE.2010.2047606","article-title":"iTUG, a sensitive and reliable measure of mobility","volume":"18","author":"Salarian","year":"2010","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1016\/j.gaitpost.2018.01.015","article-title":"Criterion validity of the instrumented Timed Up and Go test: A partial least square regression study","volume":"61","author":"Caronni","year":"2018","journal-title":"Gait Posture"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"E150","DOI":"10.1519\/JPT.0000000000000265","article-title":"Age moderates differences in performance on the instrumented timed up and go test between people with dementia and their informal caregivers","volume":"44","author":"Williams","year":"2021","journal-title":"J. Geriatr. Phys. Ther."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1080\/10803548.2020.1811516","article-title":"Dimensional reduction of balance parameters in risk of falling evaluation using a minimal number of force-sensitive resistors","volume":"28","author":"Ayena","year":"2022","journal-title":"Int. J. Occup. Saf. Ergon."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Gasparutto, X., Gueugnon, M., Laroche, D., Martz, P., Hannouche, D., and Armand, S. (2021). Which functional tasks present the largest deficits for patients with total hip arthroplasty before and six months after surgery? A study of the timed up-and-go test phases. PLoS ONE, 16.","DOI":"10.1371\/journal.pone.0255037"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"759","DOI":"10.1007\/s12652-012-0151-x","article-title":"aTUG: Technical apparatus for gait and balance analysis within component-based Timed Up & Go using mutual ambient sensors","volume":"4","author":"Frenken","year":"2013","journal-title":"J. Ambient Intell. Humaniz. Comput."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"302","DOI":"10.12965\/jer.2040532.266","article-title":"Evaluation of the psychometric properties and clinical applications of the Timed Up and Go test in Parkinson disease: A systematic review","volume":"16","author":"Mollinedo","year":"2020","journal-title":"J. Exerc. Rehabil."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1591","DOI":"10.2147\/CIA.S322506","article-title":"Reliability and diagnostic accuracy of commonly used performance tests relative to fall history in older persons: A systematic review","volume":"16","author":"Gafner","year":"2021","journal-title":"Clin. Interv. Aging"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1799","DOI":"10.1080\/09638288.2019.1682066","article-title":"The reliability and validity of the Timed Up and Go as a clinical tool in individuals with and without disabilities across a lifespan: A systematic review: Psychometric properties of the Timed Up and Go","volume":"43","author":"Christopher","year":"2021","journal-title":"Disabil. Rehabil."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"868","DOI":"10.1002\/pmrj.12154","article-title":"Effectiveness of high-intensity interval training for fitness and mobility post stroke: A systematic review","volume":"11","author":"Wiener","year":"2019","journal-title":"PM&R"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"n160","DOI":"10.1136\/bmj.n160","article-title":"PRISMA 2020 explanation and elaboration: Updated guidance and exemplars for reporting systematic reviews","volume":"372","author":"Page","year":"2021","journal-title":"BMJ"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s13643-021-01626-4","article-title":"The PRISMA 2020 statement: An updated guideline for reporting systematic reviews","volume":"10","author":"Page","year":"2021","journal-title":"Syst. Rev."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1007\/s40846-020-00512-z","article-title":"Validation of minimal number of force sensitive resistors to predict risk of falling during a timed up and go test","volume":"40","author":"Ayena","year":"2020","journal-title":"J. Med. Biol. Eng."},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Bergquist, R., Nerz, C., Taraldsen, K., Mellone, S., Ihlen, E.A., Vereijken, B., Helbostad, J.L., Becker, C., and Mikolaizak, A.S. (2020). Predicting advanced balance ability and mobility with an instrumented timed up and go test. Sensors, 20.","DOI":"10.3390\/s20174987"},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Weiss, A., Mirelman, A., Buchman, A.S., Bennett, D.A., and Hausdorff, J.M. (2013). Using a body-fixed sensor to identify subclinical gait difficulties in older adults with IADL disability: Maximizing the output of the timed up and go. PLoS ONE, 8.","DOI":"10.1371\/journal.pone.0068885"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/j.regg.2017.02.009","article-title":"Reproducibilidad de los tiempos de ejecuci\u00f3n de la prueba de Timed Up and Go, medidos con aceler\u00f3metros de smartphones en personas mayores residentes en la comunidad","volume":"52","author":"Silva","year":"2017","journal-title":"Rev. Esp. Geriatr. Gerontol."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/j.gaitpost.2012.02.006","article-title":"Validity of a Smartphone-based instrumented Timed Up and Go","volume":"36","author":"Mellone","year":"2012","journal-title":"Gait Posture"},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Coni, A., Mellone, S., Colpo, M., Bandinelli, S., and Chiari, L. (2015, January 25\u201329). Influence of age and gender on sensor-based functional measures: A factor analysis approach. Proceedings of the 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Milan, Italy.","DOI":"10.1109\/EMBC.2015.7319527"},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"David, V., Forjan, M., Martinek, J., Kotzian, S., Jagos, H., and Rafolt, D. (2017, January 17\u201320). Evaluating wearable multimodal sensor insoles for motion-pattern measurements in stroke rehabilitation\u2014A pilot study. Proceedings of the 2017 International Conference on Rehabilitation Robotics (ICORR), London, UK.","DOI":"10.1109\/ICORR.2017.8009467"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1016\/0167-9457(96)00012-7","article-title":"Programming language for motion analysis","volume":"15","author":"Holzreiter","year":"1996","journal-title":"Hum. Mov. Sci."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"1137","DOI":"10.1589\/jpts.29.1137","article-title":"The effect of cognitive-motor dual task training with the biorescue force platform on cognition, balance and dual task performance in institutionalized older adults: A randomized controlled trial","volume":"29","author":"Delbroek","year":"2017","journal-title":"J. Phys. Ther. Sci."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"1539","DOI":"10.1007\/s00702-017-1794-8","article-title":"Dopaminergic and non-dopaminergic gait components assessed by instrumented timed up and go test in Parkinson\u2019s disease","volume":"124","author":"Dibilio","year":"2017","journal-title":"J. Neural Transm."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1080\/10615806.2021.2004398","article-title":"Motor proficiency as a correlate of coping in late adult lifespan. An exploratory study","volume":"35","author":"Fastame","year":"2022","journal-title":"Anxiety Stress Coping"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"540","DOI":"10.3389\/fphys.2020.00540","article-title":"SPARC metrics provide mobility smoothness assessment in oldest-old with and without a history of falls: A case control study","volume":"11","author":"Figueiredo","year":"2020","journal-title":"Front. Physiol."},{"key":"ref_43","doi-asserted-by":"crossref","unstructured":"Mangano, G.R., Valle, M.S., Casabona, A., Vagnini, A., and Cioni, M. (2020). Age-related changes in mobility evaluated by the timed up and go test instrumented through a single sensor. Sensors, 20.","DOI":"10.3390\/s20030719"},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Mancini, M., Priest, K.C., Nutt, J.G., and Horak, F.B. (September, January 28). Quantifying freezing of gait in Parkinson\u2019s disease during the instrumented timed up and go test. Proceedings of the 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, San Diego, CA, USA.","DOI":"10.1109\/EMBC.2012.6346151"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1097\/NPT.0b013e31824620d1","article-title":"Do clinical scales of balance reflect turning abnormalities in people with Parkinson\u2019s disease?","volume":"36","author":"King","year":"2012","journal-title":"J. Neurol. Phys. Ther."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/j.jns.2019.01.023","article-title":"Gait analysis in a component timed-up-and-go test using a smartphone application","volume":"398","author":"Ishikawa","year":"2019","journal-title":"J. Neurol. Sci."},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Salarian, A., Zampieri, C., Horak, F.B., Carlson-Kuhta, P., Nutt, J.G., and Aminian, K. (2009, January 3\u20136). Analyzing 180\u00b0 turns using an inertial system reveals early signs of progression of parkinson\u2019s disease. Proceedings of the 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Minneapolis\/St. Paul, MN, USA.","DOI":"10.1109\/IEMBS.2009.5333970"},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"Silva, J., and Sousa, I. (2016, January 15\u201318). Instrumented timed up and go: Fall risk assessment based on inertial wearable sensors. Proceedings of the 2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA), Benevento, Italy.","DOI":"10.1109\/MeMeA.2016.7533778"},{"key":"ref_49","doi-asserted-by":"crossref","unstructured":"Hoskovcov\u00e1, M., Du\u0161ek, P., Sieger, T., Bro\u017eov\u00e1, H., Z\u00e1rubov\u00e1, K., Bezd\u00ed\u010dek, O., \u0160prdl\u00edk, O., Jech, R., \u0160tochl, J., and Roth, J. (2015). Predicting falls in Parkinson disease: What is the value of instrumented testing in off medication state?. PLoS ONE, 10.","DOI":"10.1371\/journal.pone.0139849"},{"key":"ref_50","doi-asserted-by":"crossref","unstructured":"Hellmers, S., Izadpanah, B., Dasenbrock, L., Diekmann, R., Bauer, J.M., Hein, A., and Fudickar, S. (2018). Towards an automated unsupervised mobility assessment for older people based on inertial TUG measurements. Sensors, 18.","DOI":"10.3390\/s18103310"},{"key":"ref_51","doi-asserted-by":"crossref","unstructured":"Beyea, J., McGibbon, C.A., Sexton, A., Noble, J., and O\u2019Connell, C. (2017). Convergent validity of a wearable sensor system for measuring sub-task performance during the timed up-and-go test. Sensors, 17.","DOI":"10.3390\/s17040934"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"1929","DOI":"10.1088\/0967-3334\/36\/9\/1929","article-title":"Clinical frailty syndrome assessment using inertial sensors embedded in smartphones","volume":"36","year":"2015","journal-title":"Physiol. Meas."},{"key":"ref_53","first-page":"279197","article-title":"Differences in trunk kinematic between frail and nonfrail elderly persons during turn transition based on a smartphone inertial sensor","volume":"2013","year":"2013","journal-title":"BioMed Res. Int."},{"key":"ref_54","first-page":"1","article-title":"Differences in trunk accelerometry between frail and non-frail elderly persons in functional tasks","volume":"7","year":"2014","journal-title":"BMC Res. Notes"},{"key":"ref_55","doi-asserted-by":"crossref","unstructured":"Van Uem, J.M., Walgaard, S., Ainsworth, E., Hasmann, S.E., Heger, T., Nussbaum, S., Hobert, M.A., Mico-Amigo, E.M., Van Lummel, R.C., and Berg, D. (2016). Quantitative timed-up-and-go parameters in relation to cognitive parameters and health-related quality of life in mild-to-moderate Parkinson\u2019s disease. PLoS ONE, 11.","DOI":"10.1371\/journal.pone.0151997"},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"1933","DOI":"10.1016\/j.jbiomech.2016.03.010","article-title":"The validity of assessing temporal events, sub-phases and trunk kinematics of the sit-to-walk movement in older adults using a single inertial sensor","volume":"49","author":"Walgaard","year":"2016","journal-title":"J. Biomech."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1007\/s11517-018-1868-2","article-title":"Automated analysis of gait and modified timed up and go using the Microsoft Kinect in people with Parkinson\u2019s disease: Associations with physical outcome measures","volume":"57","author":"Tan","year":"2019","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"1034","DOI":"10.1016\/j.gaitpost.2014.01.003","article-title":"Early identification of declining balance in higher functioning older adults, an inertial sensor based method","volume":"39","author":"Sheehan","year":"2014","journal-title":"Gait Posture"},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"3813","DOI":"10.1007\/s12206-019-0724-0","article-title":"Fall prediction of the elderly with a logistic regression model based on instrumented timed up & go","volume":"33","author":"Seo","year":"2019","journal-title":"J. Mech. Sci. Technol."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"105177","DOI":"10.1016\/j.clinbiomech.2020.105177","article-title":"Turning and sit-to-walk measures from the instrumented Timed Up and Go test return valid and responsive measures of dynamic balance in Parkinson\u2019s disease","volume":"80","author":"Picardi","year":"2020","journal-title":"Clin. Biomech."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12984-015-0026-4","article-title":"Auto detection and segmentation of physical activities during a Timed-Up-and-Go (TUG) task in healthy older adults using multiple inertial sensors","volume":"12","author":"Nguyen","year":"2015","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"1147","DOI":"10.1177\/193229681300700507","article-title":"Novel wearable technology for assessing spontaneous daily physical activity and risk of falling in older adults with diabetes","volume":"7","author":"Najafi","year":"2013","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1111\/jgs.12734","article-title":"Association between performance on Timed Up and Go subtasks and mild cognitive impairment: Further insights into the links between cognitive and motor function","volume":"62","author":"Mirelman","year":"2014","journal-title":"J. Am. Geriatr. Soc."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1109\/TBME.2012.2227317","article-title":"On-shoe wearable sensors for gait and turning assessment of patients with Parkinson\u2019s disease","volume":"60","author":"Mariani","year":"2012","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_65","doi-asserted-by":"crossref","unstructured":"Gerhardy, T., Gordt, K., Jansen, C.P., and Schwenk, M. (2019). Towards using the instrumented timed up-and-go test for screening of sensory system performance for balance control in older adults. Sensors, 19.","DOI":"10.3390\/s19030622"},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/j.medengphy.2009.10.015","article-title":"Can an accelerometer enhance the utility of the Timed Up & Go Test when evaluating patients with Parkinson\u2019s disease?","volume":"32","author":"Weiss","year":"2010","journal-title":"Med. Eng. Phys."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"864.e9","DOI":"10.1016\/j.jamda.2016.06.025","article-title":"Transition between the Timed Up and Go turn to sit subtasks: Is timing everything?","volume":"17","author":"Weiss","year":"2016","journal-title":"J. Am. Med. Dir. Assoc."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12911-021-01463-4","article-title":"Assessing elderly\u2019s functional balance and mobility via analyzing data from waist-mounted tri-axial wearable accelerometers in timed up and go tests","volume":"21","author":"Yu","year":"2021","journal-title":"BMC Med. Inform. Decis. Mak."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1007\/s10522-017-9717-5","article-title":"Aging effect on the instrumented Timed-Up-and-Go test variables in nursing home women aged 80\u201393 years","volume":"18","author":"Zarzeczny","year":"2017","journal-title":"Biogerontology"},{"key":"ref_70","doi-asserted-by":"crossref","unstructured":"Toosizadeh, N., Mohler, J., Lei, H., Parvaneh, S., Sherman, S., and Najafi, B. (2015). Motor performance assessment in Parkinson\u2019s disease: Association between objective in-clinic, objective in-home, and subjective\/semi-objective measures. PLoS ONE, 10.","DOI":"10.1371\/journal.pone.0124763"},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1109\/TNSRE.2017.2771383","article-title":"Wearable inertial sensors for fall risk assessment and prediction in older adults: A systematic review and meta-analysis","volume":"26","author":"Montesinos","year":"2018","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_72","unstructured":"Kose, A., Peruzzi, A., Cereatti, A., Laudani, L., and Della Croce, U. (2010, January 8\u201310). Detection of heel strikes and toe-offs during gait using a single inertial measurement unit attached to the waist. Proceedings of the Second National Congress of Biongineering, Turin, Italy."},{"key":"ref_73","first-page":"1","article-title":"Using the ADXL202 in pedometer and personal navigation applications","volume":"2","author":"Weinberg","year":"2002","journal-title":"Analog Devices AN-602 Appl. Note"},{"key":"ref_74","first-page":"1","article-title":"Extraction of stride events from gait accelerometry during treadmill walking","volume":"4","author":"Lowry","year":"2015","journal-title":"IEEE J. Transl. Eng. Health Med."},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1682\/JRRD.2015.04.0065","article-title":"Reliability and validity of the inertial sensor-based Timed \u201cUp and Go\u201d test in individuals affected by stroke","volume":"53","author":"Aminian","year":"2016","journal-title":"J. Rehabil. Res. Dev."},{"key":"ref_76","doi-asserted-by":"crossref","unstructured":"Pelicioni, P.H., Menant, J.C., Latt, M.D., and Lord, S.R. (2019). Falls in Parkinson\u2019s disease subtypes: Risk factors, locations and circumstances. Int. J. Environ. Res. Public Health, 16.","DOI":"10.3390\/ijerph16122216"},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"866","DOI":"10.1093\/ptj\/82.9.866","article-title":"Determinants of the sit-to-stand movement: A review","volume":"82","author":"Janssen","year":"2002","journal-title":"Phys. Ther."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/7\/3426\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T19:02:20Z","timestamp":1760122940000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/7\/3426"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,24]]},"references-count":77,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2023,4]]}},"alternative-id":["s23073426"],"URL":"https:\/\/doi.org\/10.3390\/s23073426","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,24]]}}}