{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,12]],"date-time":"2026-05-12T20:21:53Z","timestamp":1778617313983,"version":"3.51.4"},"reference-count":58,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2023,4,24]],"date-time":"2023-04-24T00:00:00Z","timestamp":1682294400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Photoplethysmography (PPG) signals have been widely used in evaluating cardiovascular biomarkers, however, there is a lack of in-depth understanding of the remote usage of this technology and its viability for underdeveloped countries. This study aims to quantitatively evaluate the performance of a low-cost wireless PPG device in detecting ultra-short-term time-domain pulse rate variability (PRV) parameters in different postures and breathing patterns. A total of 30 healthy subjects were recruited. ECG and PPG signals were simultaneously recorded in 3 min using miniaturized wearable sensors. Four heart rate variability (HRV) and PRV parameters were extracted from ECG and PPG signals, respectively, and compared using analysis of variance (ANOVA) or Scheirer\u2013Ray\u2013Hare test with post hoc analysis. In addition, the data loss was calculated as the percentage of missing sampling points. Posture did not present statistical differences across the PRV parameters but a statistical difference between indicators was found. Strong variation was found for the RMSSD indicator in the standing posture. The sitting position in both breathing patterns demonstrated the lowest data loss (1.0 \u00b1 0.6 and 1.0 \u00b1 0.7) and the lowest percentage of different factors for all indicators. The usage of commercial PPG and BLE devices can allow the reliable extraction of the PPG signal and PRV indicators in real time.<\/jats:p>","DOI":"10.3390\/s23094246","type":"journal-article","created":{"date-parts":[[2023,4,25]],"date-time":"2023-04-25T01:37:01Z","timestamp":1682386621000},"page":"4246","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Real-Time Evaluation of Time-Domain Pulse Rate Variability Parameters in Different Postures and Breathing Patterns Using Wireless Photoplethysmography Sensor: Towards Remote Healthcare in Low-Resource Communities"],"prefix":"10.3390","volume":"23","author":[{"given":"Felipe","family":"Pineda-Alpizar","sequence":"first","affiliation":[{"name":"Industrial Design Engineering Department, Costa Rica Institute of Technology, Cartago 7050, Costa Rica"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1155-3076","authenticated-orcid":false,"given":"Sergio","family":"Arriola-Valverde","sequence":"additional","affiliation":[{"name":"Electronics Engineering Department, Costa Rica Institute of Technology, Cartago 7050, Costa Rica"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mitzy","family":"Vado-Chac\u00f3n","sequence":"additional","affiliation":[{"name":"Respiratory Therapy Department, Santa Paula University, San Jose 2633, Costa Rica"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Diego","family":"Sossa-Rojas","sequence":"additional","affiliation":[{"name":"Respiratory Therapy Department, Santa Paula University, San Jose 2633, Costa Rica"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4212-2503","authenticated-orcid":false,"given":"Haipeng","family":"Liu","sequence":"additional","affiliation":[{"name":"Center of Intelligent Healthcare, Coventry University, Coventry CV1 5FB, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8077-4548","authenticated-orcid":false,"given":"Dingchang","family":"Zheng","sequence":"additional","affiliation":[{"name":"Center of Intelligent Healthcare, Coventry University, Coventry CV1 5FB, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2023,4,24]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"808451","DOI":"10.3389\/fphys.2021.808451","article-title":"Photoplethysmogram Analysis and Applications: An Integrative Review","volume":"12","author":"Park","year":"2022","journal-title":"Front. Physiol."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Vescio, B., Salsone, M., Gambardella, A., and Quattrone, A. (2018). Comparison between Electrocardiographic and Earlobe Pulse Photoplethysmographic Detection for Evaluating Heart Rate Variability in Healthy Subjects in Short- and Long-Term Recordings. Sensors, 18.","DOI":"10.3390\/s18030844"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1007\/s12553-016-0124-8","article-title":"Design Implications of e-Health Systems for a Sustainable Growth","volume":"6","author":"Roa","year":"2016","journal-title":"Health Technol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"094001","DOI":"10.1088\/1361-6579\/abaaf0","article-title":"Comparison of Different Modulations of Photoplethysmography in Extracting Respiratory Rate: From a Physiological Perspective","volume":"49","author":"Liu","year":"2020","journal-title":"Physiol. Meas."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"24716","DOI":"10.3390\/s151024716","article-title":"On Time Domain Analysis of Photoplethysmogram Signals for Monitoring Heat Stress","volume":"15","author":"Elgendi","year":"2015","journal-title":"Sensors"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1186\/1475-925X-13-139","article-title":"Detection of a and b waves in the acceleration photoplethysmogram","volume":"13","author":"Elgendi","year":"2014","journal-title":"Biomed. Eng. Online"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"111","DOI":"10.4258\/hir.2015.21.2.111","article-title":"Wave Detection in Acceleration Plethysmogram","volume":"21","author":"Ahn","year":"2015","journal-title":"Healthc. Inform. Res."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"R1","DOI":"10.1088\/0967-3334\/28\/3\/R01","article-title":"Photoplethysmography and Its Application in Clinical Physiological Measurement","volume":"28","author":"Allen","year":"2007","journal-title":"Physiol. Meas."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"198","DOI":"10.3389\/fphys.2019.00198","article-title":"Quantitative Comparison of Photoplethysmographic Waveform Characteristics: Effect of Measurement Site","volume":"10","author":"Hartmann","year":"2019","journal-title":"Front. Physiol."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Elgendi, M. (2020). PPG Signal Analysis, CRC Press.","DOI":"10.1201\/9780429449581"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1007\/s40846-019-00468-9","article-title":"Evaluation of Coherence between ECG and PPG Derived Parameters on Heart Rate Variability and Respiration in Healthy Volunteers with\/without Controlled Breathing","volume":"39","author":"Jan","year":"2019","journal-title":"J. Med. Biol. Eng."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Kr\u00f3lak, A., and Pilecka, E. (2021, January 19\u201321). Analysis and comparison of heart rate variability signals derived from PPG and ECG sensors. Proceedings of the Biocybernetics and Biomedical Engineering\u2014Current Trends and Challenges, Warsaw, Poland.","DOI":"10.1007\/978-3-030-83704-4_2"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Joseph, J., Jonkman, M., Azam, S., De Boer, F., Hill, D., and Shanmugam, B. (2018, January 4\u20136). Detection of the effect of exercise on APG signals. Proceedings of the 2018 International Conference on Computer Communication and Informatics (ICCCI), Coimbatore, India.","DOI":"10.1109\/ICCCI.2018.8441251"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Elgendi, M., Jonkman, M., and De Boer, F. (2010, January 26\u201328). Applying the APG to measure heart rate variability. Proceedings of the 2010 The 2nd International Conference on Computer and Automation Engineering (ICCAE), Singapore.","DOI":"10.1109\/ICCAE.2010.5452042"},{"key":"ref_15","first-page":"195","article-title":"A Review on Wearable Photoplethysmography Sensors and Their Potential Future Applications in Health Care","volume":"4","author":"Castaneda","year":"2018","journal-title":"Int. J. Biosens. Bioelectron."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1007\/s10916-020-01648-w","article-title":"Validity of the Empatica E4 Wristband to Measure Heart Rate Variability (HRV) Parameters: A Comparison to Electrocardiography (ECG)","volume":"44","author":"Schuurmans","year":"2020","journal-title":"J. Med. Syst."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1016\/j.procs.2019.11.153","article-title":"HRV Assessment Using Finger-Tip Photoplethysmography (Pulserate) as Compared to ECG on Healthy Subjects during Different Postures and Fixed Breathing Pattern","volume":"161","author":"Sahroni","year":"2019","journal-title":"Procedia Comput. Sci."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1007\/s13534-019-00097-w","article-title":"Current Progress of Photoplethysmography and SPO2 for Health Monitoring","volume":"9","author":"Tamura","year":"2019","journal-title":"Biomed. Eng. Lett."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"853614","DOI":"10.3389\/fcvm.2022.853614","article-title":"Remote Cardiac Rhythm Monitoring in the Era of Smart Wearables: Present Assets and Future Perspectives","volume":"9","author":"Xintarakou","year":"2022","journal-title":"Front. Cardiovasc. Med."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1016\/j.procs.2017.08.357","article-title":"IOT Based Low Cost Single Sensor Node Remote Health Monitoring System","volume":"133","author":"Garbhapu","year":"2017","journal-title":"Procedia Comput. Sci."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Hsiao, C.-C., Hsu, F.-W., Lee, R.-G., and Lin, R. (2017, January 5\u20138). Correlation analysis of heart rate variability between PPG and ECG for wearable devices in different postures. Proceedings of the 2017 IEEE International Conference on Systems, Man, and Cybernetics (SMC), Banff, AB, Canada.","DOI":"10.1109\/SMC.2017.8123077"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Camacho-Leon, G., Faytong-Haro, M., Carrera, K., Molero, M., Melean, F., Reyes, Y., Mautong, H., De La Hoz, I., and Cherrez-Ojeda, I. (2022). A Narrative Review of Telemedicine in Latin America during the COVID-19 Pandemic. Healthcare, 10.","DOI":"10.3390\/healthcare10081361"},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Nakamura, H., and Tagawa, M. (2019, January 23\u201327). Pitfall of heart rate variability analyses for autonomic nervous system activity with photoplethysmography. Proceedings of the 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Berlin, Germany.","DOI":"10.1109\/EMBC.2019.8857319"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Hern\u00e1ndez-Vicente, A., Hernando, D., Mar\u00edn-Puyalto, J., Vicente-Rodr\u00edguez, G., Garatachea, N., Pueyo, E., and Bail\u00f3n, R. (2021). Validity of the Polar H7 Heart Rate Sensor for Heart Rate Variability Analysis during Exercise in Different Age, Body Composition and Fitness Level Groups. Sensors, 21.","DOI":"10.3390\/s21030902"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"262","DOI":"10.21037\/cdt.2019.04.08","article-title":"Accuracy of Wearable Heart Rate Monitors in Cardiac Rehabilitation","volume":"9","author":"Etiwy","year":"2019","journal-title":"Cardiovasc. Diagn. Ther."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1324","DOI":"10.1123\/ijspp.2016-0668","article-title":"Comparison of Heart-Rate-Variability Recording with Smartphone Photoplethysmography, Polar H7 Chest Strap, and Electrocardiography","volume":"12","author":"Plews","year":"2017","journal-title":"Int. J. Sport. Physiol. Perform."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"258","DOI":"10.3389\/fpubh.2017.00258","article-title":"An Overview of Heart Rate Variability Metrics and Norms","volume":"5","author":"Shaffer","year":"2017","journal-title":"Front. Public Health"},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Al-Halhouli, A., Al-Ghussain, L., El Bouri, S., Habash, F., Liu, H., and Zheng, D. (2020). Clinical Evaluation of Stretchable and Wearable Inkjet-Printed Strain Gauge Sensor for Respiratory Rate Monitoring at Different Body Postures. Appl. Sci., 10.","DOI":"10.3390\/app10020480"},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Al-Halhouli, A., Al-Ghussain, L., Khallouf, O., Rabadi, A., Alawadi, J., Liu, H., Oweidat, K.A., Chen, F., and Zheng, D. (2021). Clinical Evaluation of Respiratory Rate Measurements on COPD (Male) Patients Using Wearable Inkjet-Printed Sensor. Sensors, 21.","DOI":"10.3390\/s21020468"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1138","DOI":"10.1039\/b922045c","article-title":"Baseline Correction Using Adaptive Iteratively Reweighted Penalized Least Squares","volume":"135","author":"Zhang","year":"2010","journal-title":"Analyst"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1080\/03091902.2019.1640306","article-title":"A Robust Algorithm for Heart Rate Variability Time Series Artefact Correction Using Novel Beat Classification","volume":"43","author":"Lipponen","year":"2019","journal-title":"J. Med. Eng. Technol."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1038\/s41592-019-0686-2","article-title":"SciPy 1.0: Fundamental Algorithms for Scientific Computing in Python","volume":"17","author":"Virtanen","year":"2020","journal-title":"Nat. Methods"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1007\/978-981-10-4166-2_106","article-title":"Flexible system for hrv analysis using ppg signal","volume":"Volume 62","year":"2017","journal-title":"IFMBE Proceedings"},{"key":"ref_34","unstructured":"R Core Team (2018). R Foundation for Statistical Computing, R Foundation."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"074001","DOI":"10.1088\/1361-6579\/ac0a34","article-title":"Filtering-Induced Time Shifts in Photoplethysmography Pulse Features Measured at Different Body Sites: The Importance of Filter Definition and Standardization","volume":"42","author":"Liu","year":"2021","journal-title":"Physiol. Meas."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1161\/01.HYP.32.2.365","article-title":"Assessment of Vasoactive Agents and Vascular Aging by the Second Derivative of Photoplethysmogram Waveform","volume":"32","author":"Takazawa","year":"1998","journal-title":"Hypertension"},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Chen, X., Chen, T., Luo, F., and Li, J. (2013, January 16\u201318). Comparison of valley-to-valley and peak-to-peak intervals from photoplethysmographic signals to obtain heart rate variability in the sitting position. Proceedings of the 2013 6th International Conference on Biomedical Engineering and Informatics, Hangzhou, China.","DOI":"10.1109\/BMEI.2013.6746936"},{"key":"ref_38","unstructured":"Rozi, R.M., Ali, M.M., and Reaz, M. (2010, January 6\u20139). Effects of exercise on the second derivative photoplethysmography(Ppg) waveform. Proceedings of the 2010 IEEE Asia Pacific Conference on Circuits and Systems, Kuala Lumpur, Malaysia."},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Jiang, M., Mieronkoski, R., Rahmani, A.M., Hagelberg, N., Salantera, S., and Liljeberg, P. (2017, January 13\u201316). Ultra-short-term analysis of heart rate variability for real-time acute pain monitoring with wearable electronics. Proceedings of the 2017 IEEE International Conference on Bioinformatics and Biomedicine (BIBM), Kansas City, MO, USA.","DOI":"10.1109\/BIBM.2017.8217798"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"594880","DOI":"10.3389\/fnins.2020.594880","article-title":"A Critical Review of Ultra-Short-Term Heart Rate Variability Norms Research","volume":"14","author":"Shaffer","year":"2020","journal-title":"Front. Neurosci."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"14079","DOI":"10.1038\/s41598-019-50526-0","article-title":"Speckleplethysmographic (SPG) Estimation of Heart Rate Variability during an Orthostatic Challenge","volume":"9","author":"Dunn","year":"2019","journal-title":"Sci. Rep."},{"key":"ref_42","doi-asserted-by":"crossref","unstructured":"Taoum, A., Bisiaux, A., Tilquin, F., Le Guillou, Y., and Carrault, G. (2022). Validity of Ultra-Short-Term HRV Analysis Using PPG\u2014A Preliminary Study. Sensors, 22.","DOI":"10.3390\/s22207995"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"1527","DOI":"10.1007\/s00421-016-3401-3","article-title":"Heart Rate Variability (HRV) in Deep Breathing Tests and 5-Min Short-Term Recordings: Agreement of Ear Photoplethysmography with ECG Measurements, in 343 Subjects","volume":"116","author":"Weinschenk","year":"2016","journal-title":"Eur. J. Appl. Physiol."},{"key":"ref_44","first-page":"931943","article-title":"SDNN\/RMSSD as a Surrogate for LF\/Hf: A Revised Investigation","volume":"2012","author":"Wang","year":"2012","journal-title":"Model. Simul. Eng."},{"key":"ref_45","doi-asserted-by":"crossref","unstructured":"Hussein, A.F., Hashim, S.J., Aziz, A.F.A., Rokhani, F.Z., and Adnan, W.A.W. (2017). A Real Time ECG Data Compression Scheme for Enhanced Bluetooth Low Energy ECG System Power Consumption. J. Ambient. Intell. Humaniz. Comput.","DOI":"10.1007\/s12652-017-0560-y"},{"key":"ref_46","unstructured":"Zhang, Y., Weng, J., Dey, R., and Fu, X. (2020). Encyclopedia of Wireless Networks, Springer."},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Aysin, B., and Aysin, E. (September, January 30). Effect of respiration in heart rate variability (HRV) Analysis. Proceedings of the 2006 International Conference of the IEEE Engineering in Medicine and Biology Society, New York, NY, USA.","DOI":"10.1109\/IEMBS.2006.260773"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"823","DOI":"10.3389\/fphys.2020.00823","article-title":"Influences of Sensor Placement Site and Subject Posture on Measurement of Respiratory Frequency Using Triaxial Accelerometers","volume":"11","author":"Hughes","year":"2020","journal-title":"Front. Physiol."},{"key":"ref_49","doi-asserted-by":"crossref","unstructured":"Schneider, P., and Xhafa, F. (2022). Anomaly Detection and Complex Event Processing Over IOT Data Streams, Academic Press.","DOI":"10.1016\/B978-0-12-823818-9.00014-6"},{"key":"ref_50","unstructured":"Oliveira, B., Oliveira, \u00d3., and Belo, O. (2021). Proceedings of the 10th International Conference on Data Science, Technology and Applications, SciTePress."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"102015","DOI":"10.1016\/j.adhoc.2019.102015","article-title":"Beyond Beaconing: Emerging Applications and Challenges of Ble","volume":"97","author":"Yang","year":"2020","journal-title":"Ad Hoc Netw."},{"key":"ref_52","doi-asserted-by":"crossref","unstructured":"Nikodem, M., Slabicki, M., and Bawiec, M. (2020). Efficient Communication Scheme for Bluetooth Low Energy in Large Scale Applications. Sensors, 20.","DOI":"10.3390\/s20216371"},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1109\/MCC.2016.139","article-title":"Healthcare-Related Data in the Cloud: Challenges and Opportunities","volume":"3","author":"Casola","year":"2016","journal-title":"IEEE Cloud Comput."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1016\/j.ijinfomgt.2018.07.009","article-title":"Cloud Computing-Enabled Healthcare Opportunities, Issues, and Applications: A Systematic Review","volume":"43","author":"Ali","year":"2018","journal-title":"Int. J. Inf. Manag."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1177\/1479972316633414","article-title":"Rural and Remote Care","volume":"13","author":"Goodridge","year":"2016","journal-title":"Chronic Respir. Dis."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1007\/s10916-017-0854-9","article-title":"Personalized Health Monitoring System for Managing Well-Being in Rural Areas","volume":"42","author":"Nedungadi","year":"2017","journal-title":"J. Med. Syst."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1007\/s10877-020-00481-3","article-title":"Clinical evaluation of stretchable and wearable inkjet-printed strain gauge sensor for respiratory rate monitoring at different measurements locations","volume":"35","author":"Liu","year":"2021","journal-title":"J. Clin. Monit. Comput."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"411","DOI":"10.33678\/cor.2022.083","article-title":"Feasibility of evaluation of Polar H10 chest-belt ECG in patients with a broad range of heart conditions","volume":"64","author":"Rada","year":"2022","journal-title":"Cor Vasa"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/9\/4246\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T19:22:43Z","timestamp":1760124163000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/9\/4246"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4,24]]},"references-count":58,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2023,5]]}},"alternative-id":["s23094246"],"URL":"https:\/\/doi.org\/10.3390\/s23094246","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,4,24]]}}}