{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,16]],"date-time":"2026-11-16T19:40:41Z","timestamp":1794858041253,"version":"4.9.1"},"reference-count":20,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2023,4,25]],"date-time":"2023-04-25T00:00:00Z","timestamp":1682380800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The dielectric loss angle can better reflect the overall insulation level of mining cables, so it is necessary to implement reliable and effective online monitoring of the dielectric loss angle of mining cables. In order to improve the monitoring accuracy of the dielectric loss angle tan \u03b4 of mining cables, a low-frequency dielectric loss angle online monitoring method combining signal injection method and double-end synchronous measurement method is proposed in this paper. Firstly, the superiority of the low-frequency signal in improving the detection accuracy of dielectric loss angle is explained, and the feasibility of the low-frequency signal injection method is analyzed. Secondly, the cable leakage is calculated using the double-terminal synchronous measurement method to measure the core current at the first and last ends of the cable, and the phase sum of the voltage at the first and last ends is selected as the reference phase quantity to realize the effective calculation of the dielectric loss angle tan \u03b4 of the cable. Then, the simulation model for online monitoring of dielectric loss angle of mining cable is built, and the feasibility of the online monitoring method proposed in this paper is verified by combining the simulation results. Finally, the theoretical and simulation analysis of the monitoring error of dielectric loss angle of mining cable is carried out.<\/jats:p>","DOI":"10.3390\/s23094273","type":"journal-article","created":{"date-parts":[[2023,4,26]],"date-time":"2023-04-26T01:44:42Z","timestamp":1682473482000},"page":"4273","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["An Online Monitoring Method for Low-Frequency Dielectric Loss Angle of Mining Cables"],"prefix":"10.3390","volume":"23","author":[{"given":"Yanwen","family":"Wang","sequence":"first","affiliation":[{"name":"School of Mechanical, Electronic & Information Engineering, China University of Mining and Technology (Beijing), Beijing 100083, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6900-8567","authenticated-orcid":false,"given":"Peng","family":"Chen","sequence":"additional","affiliation":[{"name":"School of Mechanical, Electronic & Information Engineering, China University of Mining and Technology (Beijing), Beijing 100083, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chen","family":"Feng","sequence":"additional","affiliation":[{"name":"College of Electrical Engineering and Automation, Shandong University of Science and Technology, Qingdao 266590, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiyuan","family":"Cao","sequence":"additional","affiliation":[{"name":"School of Mechanical, Electronic & Information Engineering, China University of Mining and Technology (Beijing), Beijing 100083, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,4,25]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"2247017","DOI":"10.1155\/2022\/2247017","article-title":"A Study on Insulation Monitoring Technology of High-Voltage Cables in Underground Coal Mines Based on Decision Tree","volume":"2022","author":"Fu","year":"2022","journal-title":"Comput. Intel. Neurosci."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Feng, C., Yang, M., Zeng, X., and Chen, P. (2020, January 4\u20136). Mine Cable Insulation Double-End Synchronous Monitoring with 5G Transmission Technology. Proceedings of the 2020 IEEE 3rd Student Conference on Electrical Machines and Systems (SCEMS), Jinan, China.","DOI":"10.1109\/SCEMS48876.2020.9352433"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1109\/TPWRS.2015.2403310","article-title":"Analysis and Control of Bipolar LVDC Grid with DC Symmetrical Component Method","volume":"31","author":"Gu","year":"2016","journal-title":"IEEE Trans. Power Syst."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Wang, S., Li, H., Liu, Q., Huang, Q., and Liu, Y. (2020, January 2\u20136). Design of a DC Residual Current Sensor Based on the Improved DC Component Method. Proceedings of the 2020 IEEE Power & Energy Society General Meeting (PESGM), Montreal, QC, Canada.","DOI":"10.1109\/PESGM41954.2020.9281515"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"13586","DOI":"10.1109\/TIE.2022.3142434","article-title":"A Novel Online Monitoring Scheme for Underground Power Cable Insulation Based on Common-Mode Leakage Current Measurement","volume":"69","author":"Wu","year":"2022","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1961","DOI":"10.1109\/TIE.2022.3159922","article-title":"Online Monitoring for Underground Power Cable Insulation Based on Resonance Frequency Analysis Under Chirp Signal Injection","volume":"70","author":"Wu","year":"2023","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"7360","DOI":"10.1109\/TIE.2021.3102410","article-title":"Online Monitoring for Underground Power Cable Insulation Based on Common-Mode Signal Injection","volume":"69","author":"Wu","year":"2022","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"46057","DOI":"10.1109\/ACCESS.2022.3170145","article-title":"Insulation Monitoring and Diagnosis of Faults in Cross-Bonded Cables Based on the Resistive Current and Sheath Current","volume":"10","author":"Zhu","year":"2022","journal-title":"IEEE Access"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Zhang, H., Duan, Y., Su, J., Li, S., Hu, X., and Yao, J. (2019, January 10\u201311). Development and Application of XLPE High Voltage Cable Grounding Circulation Online Monitoring System. Proceedings of the 2nd International Conference on Frontiers of Materials Synthesis and Processing (FMSP), Sanya, China.","DOI":"10.1088\/1757-899X\/493\/1\/012086"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1811","DOI":"10.1109\/TPWRD.2011.2114373","article-title":"Identifying Harmonic Attributes from Online Partial Discharge Data","volume":"26","author":"Catterson","year":"2011","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1585","DOI":"10.1109\/TPWRD.2011.2124474","article-title":"The Use of Partial Discharges as an Online Monitoring System for Underground Cable Joints","volume":"26","author":"Wu","year":"2011","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"3558","DOI":"10.1109\/TIA.2022.3160131","article-title":"An Improved Online Stator Insulation Monitoring Method Based on Common-Mode Impedance Spectrum Considering the Effect of Aging Position","volume":"58","author":"Zheng","year":"2022","journal-title":"IEEE Trans. Ind. Appl."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1021","DOI":"10.1109\/TIA.2018.2866983","article-title":"Online Partial Discharge Insulation Condition Monitoring of Complete High-Voltage Networks","volume":"55","author":"Renforth","year":"2019","journal-title":"IEEE Trans. Ind. Appl."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"144444","DOI":"10.1109\/ACCESS.2019.2944570","article-title":"Distributed Online Monitoring Method and Application of Cable Partial Discharge Based on phi-OTDR","volume":"7","author":"Pan","year":"2019","journal-title":"IEEE Access"},{"key":"ref_15","unstructured":"(2023, April 24). IEEE Draft Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF) (Less Than 1 Hz). Available online: https:\/\/ieeexplore.ieee.org\/document\/6182570."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1109\/TDEI.2015.004995","article-title":"On-line Monitoring Method for Long Distance Power Cable Insulation","volume":"23","author":"Pang","year":"2016","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Yang, Y., Hepburn, D.M., Zhou, C., Jiang, W., Yang, B., and Zhou, W. (2015, January 19\u201322). On-line Monitoring and Trending of Dielectric Loss in a Cross-bonded HV Cable System. Proceedings of the 2015 IEEE 11th International Conference on the Properties and Applications of Dielectric Materials (ICPADM), Sydney, NSW, Australia.","DOI":"10.1109\/ICPADM.2015.7295268"},{"key":"ref_18","first-page":"1","article-title":"Online Monitoring of Power Cables Tangent Delta Based on Low-Frequency Signal Injection Method","volume":"70","author":"Zhu","year":"2021","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_19","unstructured":"IEC Standard Voltages (Standard No. IEC60038:2009)."},{"key":"ref_20","unstructured":"Hameed, S.K.M., Joseph, J., and Sindhu, T.K. (2016, January 22\u201325). Detection of Location and size of Water Tree in XLPE Cables by Frequency Response Analysis: A Simulation Study. Proceedings of the 2016 IEEE Region 10 Conference (TENCON), IEEE Region 10 Conference (TENCON), Singapore."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/9\/4273\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T19:23:28Z","timestamp":1760124208000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/9\/4273"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4,25]]},"references-count":20,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2023,5]]}},"alternative-id":["s23094273"],"URL":"https:\/\/doi.org\/10.3390\/s23094273","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,4,25]]}}}