{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T06:01:36Z","timestamp":1785477696095,"version":"3.56.0"},"reference-count":27,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2023,5,8]],"date-time":"2023-05-08T00:00:00Z","timestamp":1683504000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Civil Services Commission"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A link between inappropriate physical behaviour patterns (low physical activity and high sedentary behaviour) and poor health outcomes has been observed. To provide evidence to quantify this link, it is important to have valid and reliable assessment tools. This study aimed to assess the validity and reliability of the activPAL4TM monitor for distinguishing postures and measuring stepping activity of 6\u201312-year-old children. Thirteen children (8.5 \u00b1 1.8 years) engaged in pre-determined standardised (12 min) and non-standardised (6 min) activities. Agreement, specificity and positive predictive value were assessed between the activPAL4TM and direct observation (DO) (nearest 0.1 s). Between-activPAL4TM (inter-device) and between-observer (inter-rater) reliability were determined. Detection of sitting and stepping time and forward purposeful step count were all within 5% of DO. Standing time was slightly overestimated (+10%) and fast walking\/jogging steps underestimated (\u221220%). For non-standardised activities, activPAL4TM step count matched most closely to combined backward and forward purposeful steps; however, agreement varied widely. The activPAL4TM demonstrated high levels of reliability (ICC(1, 1) &gt; 0.976), which were higher in some instances than could be achieved through direct observation (ICC(2, 1) &gt; 0.851 for non-standardised activities). Overall, the activPAL4TM recorded standardised activities well. However, further work is required to establish the exact nature of steps counted by the activPAL4TM.<\/jats:p>","DOI":"10.3390\/s23094555","type":"journal-article","created":{"date-parts":[[2023,5,8]],"date-time":"2023-05-08T03:00:28Z","timestamp":1683514828000},"page":"4555","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Validity and Reliability of the activPAL4TM for Measurement of Body Postures and Stepping Activity in 6\u201312-Year-Old Children"],"prefix":"10.3390","volume":"23","author":[{"given":"Esraa","family":"Burahmah","sequence":"first","affiliation":[{"name":"School of Health and Life Sciences, Glasgow Caledonian University, Cowcaddens Road, Glasgow G4 0BA, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sivaramkumar","family":"Shanmugam","sequence":"additional","affiliation":[{"name":"School of Health and Life Sciences, Glasgow Caledonian University, Cowcaddens Road, Glasgow G4 0BA, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Williams","sequence":"additional","affiliation":[{"name":"School of Health and Life Sciences, Glasgow Caledonian University, Cowcaddens Road, Glasgow G4 0BA, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1581-2928","authenticated-orcid":false,"given":"Ben","family":"Stansfield","sequence":"additional","affiliation":[{"name":"School of Health and Life Sciences, Glasgow Caledonian University, Cowcaddens Road, Glasgow G4 0BA, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,5,8]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1016\/S0140-6736(12)60646-1","article-title":"Global physical activity levels: Surveillance progress, pitfalls, and prospects","volume":"380","author":"Hallal","year":"2012","journal-title":"Lancet"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1186\/s12966-020-01042-2","article-title":"Advancing the global physical activity agenda: Recommendations for future research by the 2020 WHO physical activity and sedentary behavior guidelines development group","volume":"17","author":"DiPietro","year":"2020","journal-title":"Int. J. Behav. Nutr. Phys. Act."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1016\/S0140-6736(12)61031-9","article-title":"Effect of physical inactivity on major non-communicable diseases worldwide: An analysis of burden of disease and life expectancy","volume":"380","author":"Lee","year":"2012","journal-title":"Lancet"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"123","DOI":"10.7326\/M14-1651","article-title":"Sedentary time and its association with risk for disease incidence, mortality, and hospitalization in adults","volume":"162","author":"Biswas","year":"2015","journal-title":"Ann. Intern. Med."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Meh, K., Jurak, G., Sori\u0107, M., Rocha, P., and Sember, V. (2021). Validity and reliability of IPAQ-SF and GPAQ for assessing sedentary behaviour in adults in the European Union: A systematic review and meta-analysis. Int. J. Environ. Res. Public Health, 18.","DOI":"10.3390\/ijerph18094602"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1016\/j.gaitpost.2022.08.002","article-title":"Validity of the ActivPAL monitor to measure stepping activity and activity intensity: A systematic review","volume":"97","author":"Wu","year":"2022","journal-title":"Gait Posture"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.gaitpost.2022.03.002","article-title":"Validity of the ActivPAL monitor to distinguish postures: A systematic review","volume":"94","author":"Wu","year":"2022","journal-title":"Gait Posture"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1249\/MSS.0b013e3181ef5a93","article-title":"Objective and subjective measures of sedentary behavior and physical activity","volume":"43","author":"Hart","year":"2011","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"992","DOI":"10.1136\/bjsm.2006.030262","article-title":"The validation of a novel activity monitor in the measurement of posture and motion during everyday activities","volume":"40","author":"Grant","year":"2006","journal-title":"Br. J. Sports Med."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"277","DOI":"10.2522\/ptj.20100159","article-title":"Evaluation of a body-worn sensor system to measure physical activity in older people with impaired function","volume":"91","author":"Taraldsen","year":"2011","journal-title":"Phys. Ther."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/j.gaitpost.2015.10.020","article-title":"Validity and reliability of the activPAL3 for measuring posture and stepping in adults and young people","volume":"43","author":"Sellers","year":"2016","journal-title":"Gait Posture"},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Alghaeed, Z., Reilly, J.J., Chastin, S.F.M., Martin, A., Davies, G., and Paton, J.Y. (2013). The influence of minimum sitting period of the ActivPAL\u2122 on the measurement of breaks in sitting in young children. PLoS ONE, 8.","DOI":"10.1371\/journal.pone.0071854"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1002\/uog.122","article-title":"Applying the right statistics: Analyses of measurement studies","volume":"22","author":"Bland","year":"2003","journal-title":"Ultrasound Obstet. Gynecol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"989","DOI":"10.1093\/ptj\/78.9.989","article-title":"Validity and reliability of measurements obtained with an \"activity monitor\" in people with and without a transtibial amputation","volume":"78","author":"Bussmann","year":"1998","journal-title":"Phys. Ther."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1037\/0033-2909.86.2.420","article-title":"Intraclass correlations: Uses in assessing rater reliability","volume":"86","author":"Shrout","year":"1979","journal-title":"Psychol. Bull."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Dowd, K.P., Harrington, D.M., and Donnelly, A.E. (2012). Criterion and concurrent validity of the ActivPAL\u2122 professional physical activity monitor in adolescent females. PLoS ONE, 7.","DOI":"10.1371\/journal.pone.0047633"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1123\/jmpb.2019-0068","article-title":"Validating accelerometers for the assessment of body position and sedentary behavior","volume":"3","author":"Giurgiu","year":"2020","journal-title":"J. Meas. Phys. Behav."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"761","DOI":"10.1249\/MSS.0b013e31823b1dc7","article-title":"Validity, practical utility, and reliability of the ActivPAL\u2122 in preschool children","volume":"44","author":"Davies","year":"2012","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1186\/s12966-016-0402-x","article-title":"Criterion validity of the ActivPALTM and ActiGraph for assessing children\u2019s sitting and standing time in a school classroom setting","volume":"13","author":"Ridley","year":"2016","journal-title":"Int. J. Behav. Nutr. Phys. Act."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2549","DOI":"10.1016\/j.apmr.2013.07.019","article-title":"Evaluation of an activity monitor for the objective measurement of free-living physical activity in children with cerebral palsy","volume":"94","author":"Tang","year":"2013","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1123\/pes.2013-0106","article-title":"Validation of ActivPAL defined sedentary time and breaks in sedentary time in 4- to 6-year-olds","volume":"26","author":"Janssen","year":"2014","journal-title":"Pediatr. Exerc. Sci."},{"key":"ref_22","first-page":"273","article-title":"Validation of thigh-based accelerometer estimates of postural allocation in 5\u201312 year-olds","volume":"20","author":"Okely","year":"2016","journal-title":"J. Sci. Med. Sport"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1186\/1479-5868-9-119","article-title":"Examining the validity of the ActivPAL monitor in measuring posture and ambulatory movement in children","volume":"9","author":"Aminian","year":"2012","journal-title":"Int. J. Behav. Nutr. Phys. Act."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/j.medengphy.2014.10.003","article-title":"Characteristics of very slow stepping in healthy adults and validity of the activPAL3\u2122 activity monitor in detecting these steps","volume":"37","author":"Stansfield","year":"2015","journal-title":"Med. Eng. Phys."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Kirk, A.G., Kimmel, L.A., Behm, K.J., Peiris, C.L., and Ekegren, C.L. (2022). Validity of the ActivPAL and ActiGraph for measuring sitting time and steps in hospitalised orthopaedic patients with altered weight bearing. Disabil. Rehabil., 1\u20139.","DOI":"10.1080\/09638288.2022.2157896"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1186\/s12966-021-01167-y","article-title":"A catalog of validity indices for step counting wearable technologies during treadmill walking: The CADENCE-Kids study","volume":"18","author":"Gould","year":"2021","journal-title":"Int. J. Behav. Nutr. Phys. Act."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Stenb\u00e4ck, V., Lepp\u00e4luoto, J., Juustila, R., Niiranen, L., Gagnon, D., Tulppo, M., and Herzig, K.-H. (2022). Step detection accuracy and energy expenditure estimation at different speeds by three accelerometers in a controlled environment in overweight\/obese subjects. J. Clin. Med., 11.","DOI":"10.3390\/jcm11123267"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/9\/4555\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T19:31:03Z","timestamp":1760124663000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/9\/4555"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,8]]},"references-count":27,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2023,5]]}},"alternative-id":["s23094555"],"URL":"https:\/\/doi.org\/10.3390\/s23094555","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,5,8]]}}}