{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T02:09:29Z","timestamp":1760148569633,"version":"build-2065373602"},"reference-count":64,"publisher":"MDPI AG","issue":"10","license":[{"start":{"date-parts":[[2023,5,18]],"date-time":"2023-05-18T00:00:00Z","timestamp":1684368000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The integration of Distributed Generators (DGs) into distribution systems (DSs) leads to more reliable and efficient power delivery for customers. However, the possibility of bi-directional power flow creates new technical problems for protection schemes. This poses a threat to conventional strategies because the relay settings have to be adjusted depending on the network topology and operational mode. As a solution, it is important to develop novel fault protection techniques to ensure reliable protection and avoid unnecessary tripping. In this regard, Total Harmonic Distortion (THD) can be used as a key parameter for evaluating the grid\u2019s waveform quality during fault events. This paper presents a comparison between two DS protection strategies that employ THD levels, estimated amplitude voltages, and zero-sequence components as instantaneous indicators during the faults that function as a kind of fault sensor to detect, identify, and isolate faults. The first method uses a Multiple Second Order Generalized Integrator (MSOGI) to obtain the estimated variables, whereas the second method uses a single SOGI for the same purpose (SOGI-THD). Both methods rely on communication lines between protective devices (PDs) to facilitate coordinated protection. The effectiveness of these methods is assessed by using simulations in MATLAB\/Simulink considering various factors such as different types of faults and DG penetrations, different fault resistances and fault locations in the proposed network. Moreover, the performance of these methods is compared with conventional overcurrent and differential protections. The results show that the SOGI-THD method is highly effective in detecting and isolating faults with a time interval of 6\u20138.5 ms using only three SOGIs while requiring only 447 processor cycles for execution. In comparison to other protection methods, the SOGI-THD method exhibits a faster response time and a lower computational burden. Furthermore, the SOGI-THD method is robust to harmonic distortion, as it considers pre-existing harmonic content before the fault and avoids interference with the fault detection process.<\/jats:p>","DOI":"10.3390\/s23104874","type":"journal-article","created":{"date-parts":[[2023,5,18]],"date-time":"2023-05-18T10:17:26Z","timestamp":1684405046000},"page":"4874","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["A Comparative Study of Smart THD-Based Fault Protection Techniques for Distribution Networks"],"prefix":"10.3390","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3584-0187","authenticated-orcid":false,"given":"Wael","family":"Al Hanaineh","sequence":"first","affiliation":[{"name":"Electric Engineering Department, Polytechnic University of Catalonia (EEBE-UPC), 08019 Barcelona, Spain"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3854-1526","authenticated-orcid":false,"given":"Jose","family":"Matas","sequence":"additional","affiliation":[{"name":"Electric Engineering Department, Polytechnic University of Catalonia (EEBE-UPC), 08019 Barcelona, Spain"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5236-4592","authenticated-orcid":false,"given":"Josep M.","family":"Guerrero","sequence":"additional","affiliation":[{"name":"Department of Energy Technology, Aalborg University, 9200 Aalborg, Denmark"}]}],"member":"1968","published-online":{"date-parts":[[2023,5,18]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Ates, Y., Uzunoglu, M., Karakas, A., and Boynuegri, A.R. (April, January 31). The Case Study Based Protection Analysis for Smart Distribution Grids Including Distributed Generation Units. Proceedings of the 12th IET International Conference on Developments in Power System Protection (DPSP 2014), Copenhagen, Denmark.","DOI":"10.1049\/cp.2014.0144"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Saadeh, O.S., Al-Hanaineh, W., and Dalala, Z. (2022, January 26\u201329). Islanding mode operation of a PV supplied network in the presence of G59 protection. Proceedings of the 2022 IEEE 13th International Symposium on Power Electronics for Distributed Generation Systems (PEDG), Kiel, Germany.","DOI":"10.1109\/PEDG54999.2022.9923097"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1308","DOI":"10.1016\/j.rser.2015.12.258","article-title":"A review of protection systems for distribution networks embedded with renewable generation","volume":"58","author":"Kennedy","year":"2016","journal-title":"Renew. Sustain. Energy Rev."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Norshahrani, M., Mokhlis, H., Abu Bakar, A.H., Jamian, J.J., and Sukumar, S. (2017). Progress on protection strategies to mitigate the impact of renewable distributed generation on distribution systems. Energies, 10.","DOI":"10.3390\/en10111864"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"5944","DOI":"10.1049\/iet-gtd.2019.1652","article-title":"Impact of distributed generation on the protection systems of distribution networks: Analysis and remedies\u2013review paper","volume":"14","author":"Meskin","year":"2020","journal-title":"IET Gener. Transm. Distrib."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Bakkar, M., Bogarra, S., C\u00f3rcoles, F., Iglesias, J., and Al Hanaineh, W. (2022). Multi-Layer Smart Fault Protection for Secure Smart Grids. IEEE Trans. Smart Grid, early access.","DOI":"10.1109\/TSG.2022.3229848"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1186\/s41601-017-0061-1","article-title":"Protection coordination in distribution systems with and without distributed energy resources\u2014A review","volume":"2","author":"Singh","year":"2017","journal-title":"Prot. Control. Mod. Power Syst."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1311","DOI":"10.1109\/JPROC.2017.2696878","article-title":"Distributed power-generation systems and protection","volume":"105","author":"Blaabjerg","year":"2017","journal-title":"Proc. IEEE"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"557","DOI":"10.3934\/energy.2019.5.557","article-title":"Review of adaptive protection methods for microgrids","volume":"7","author":"Senarathna","year":"2019","journal-title":"AIMS Energy"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Colson, C.M., and Nehrir, M.H. (2009, January 26\u201330). A review of challenges to real-time power management of microgrids. Proceedings of the 2009 IEEE Power & Energy Society General Meeting, Calgary, AB, Canada.","DOI":"10.1109\/PES.2009.5275343"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"949","DOI":"10.1016\/j.rser.2017.03.021","article-title":"Fault location and detection techniques in power distribution systems with distributed generation: A review","volume":"74","author":"Gururajapathy","year":"2017","journal-title":"Renew. Sustain. Energy Rev."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Blackburn, J.L., and Domin, T.J. (2015). Protective Relaying Principles and Applications, Marcel Dekker. [4th ed.].","DOI":"10.1201\/b16518"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1049\/iet-gtd.2018.5212","article-title":"Review on microgrids protection","volume":"13","author":"Beheshtaein","year":"2019","journal-title":"IET Gener. Transm. Distrib."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1385","DOI":"10.1109\/TIA.2013.2283237","article-title":"Future Distribution Feeder Protection Using Directional Overcurrent Elements","volume":"50","author":"Jones","year":"2014","journal-title":"IEEE Trans. Ind. Appl."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1109\/TSG.2014.2357813","article-title":"Optimal Protection Coordination for Meshed Distribution Systems with Dg Using Dual Setting Directional Over-Current Relays","volume":"6","author":"Zeineldin","year":"2015","journal-title":"IEEE Trans. Smart Grid"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1159","DOI":"10.1049\/gtd2.12093","article-title":"Overcurrent protection based on ANNs for smart distribution networks with grid-connected VSIs","volume":"15","author":"Bakkar","year":"2020","journal-title":"IET Gener. Transm. Distrib."},{"key":"ref_17","unstructured":"Dewadasa, M., Ghosh, A., and Ledwich, G. (2011, January 25\u201328). Protection of Microgrids Using Differential Relays. Proceedings of the Power Engineering Conference (AUPEC), Australasian Universities, Brisbane, Australia."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Ustun, T.S., Ozansoy, C., and Zayegh, A. (2013, January 17\u201319). Differential Protection of Microgrids with Central Protection Unit Support. Proceedings of the IEEE 2013 Tencon\u2014Spring, Sydney, Australia.","DOI":"10.1109\/TENCONSpring.2013.6584408"},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Hodder, S., Kasztenny, B., and Fischer, N. (2012, January 2\u20135). Backup considerations for line current differential protection. Proceedings of the 2012 65th Annual Conference for Protective Relay Engineers, College Station, TX, USA.","DOI":"10.1109\/CPRE.2012.6201224"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1109\/TPWRD.2003.820204","article-title":"Development of Adaptive Protection Scheme for Distribution Systems with High Penetration of Distributed Generation","volume":"19","author":"Brahma","year":"2004","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Ma, J., Mi, C., Wang, T., Wu, J., and Wang, Z. (2011, January 24\u201329). An Adaptive Protection Scheme for Distributed Systems with Distributed Generation. Proceedings of the Power and Energy Society General Meeting, Detroit, MI, USA.","DOI":"10.1109\/PES.2011.6039832"},{"key":"ref_22","unstructured":"Choi, J.H., Nam, S.R., Nam, H.K., and Kim, J.C. (2008, January 24\u201327). Adaptive protection schemes of Distributed Generation at distribution network for automatic reclosing and voltage sags. Proceedings of the 2008 IEEE International Conference on Sustainable Energy Technologies, Singapore."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Beheshtaein, S., Cuzner, R., Savaghebi, M., and Guerrero, J.M. (2018, January 5\u201310). A new harmonic-based protection structure for meshed microgrids. Proceedings of the 2018 IEEE Power & Energy Society General Meeting (PESGM), Portland, OR, USA.","DOI":"10.1109\/PESGM.2018.8585807"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Al-Nasseri, H., and Redfern, M.A. (2008, January 12\u201315). Harmonics content based protection scheme for micro-grids dominated by solid state converters. Proceedings of the 12th International Middle-East Power System Conference, Aswan, Egypt.","DOI":"10.1109\/MEPCON.2008.4562361"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1016\/j.ijepes.2015.11.048","article-title":"Fast fault detection and classification based on a combination of wavelet singular entropy theory and fuzzy logic in distribution lines in the presence of distributed generations","volume":"78","author":"Dehghani","year":"2016","journal-title":"Int. J. Electr. Power Energy Syst."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Ahmadipour, M., Hizam, H., Othman, M.L., Mohd Radzi, M.A., and Chireh, N. (2019). A Fast Fault Identification in a Grid-Connected Photovoltaic System Using Wavelet Multi-Resolution Singular Spectrum Entropy and Support Vector Machine. Energies, 12.","DOI":"10.3390\/en12132508"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"106572","DOI":"10.1016\/j.epsr.2020.106572","article-title":"Protection strategy for fault detection in inverter-dominated low voltage AC microgrid","volume":"190","author":"Pinto","year":"2021","journal-title":"Electr. Power Syst. Res."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"13","DOI":"10.14257\/ijgdc.2018.11.9.02","article-title":"High impedance fault detection using fuzzy logic technique","volume":"11","author":"Vyshnavi","year":"2018","journal-title":"Int. J. Grid Distrib. Comput."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1016\/j.ijepes.2018.04.009","article-title":"Fault detection and location in a microgrid using mathematical morphology and recursive least square methods","volume":"102","author":"Gush","year":"2018","journal-title":"Int. J. Electr. Power Energy Syst."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"2325","DOI":"10.1049\/rpg2.12167","article-title":"Microgrid protection against high impedance faults with robustness to harmonic intrusion and weather intermittency","volume":"15","author":"Manohar","year":"2021","journal-title":"IET Renew. Power Gener."},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Sharma, N.K., and Samantaray, S.R. (2018, January 14\u201316). Validation of differential phaseangle based microgrid protection scheme on RTDS platform. Proceedings of the 20th National Power Systems Conference (NPSC), Tiruchirappalli, India.","DOI":"10.1109\/NPSC.2018.8771793"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1967","DOI":"10.48084\/etasr.1472","article-title":"A probabilistic approach for the evaluation of fault detection schemes in microgrids","volume":"7","author":"Eslami","year":"2017","journal-title":"Eng. Technol. Appl. Sci. Res."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"108366","DOI":"10.1016\/j.measurement.2020.108366","article-title":"PSD based high impedance fault detection and classification in distribution system","volume":"169","author":"Roy","year":"2021","journal-title":"Measurement"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"106239","DOI":"10.1016\/j.epsr.2020.106239","article-title":"A combined deep belief network and time-time transform based intelligent protection Scheme for microgrids","volume":"182","author":"Gashteroodkhani","year":"2020","journal-title":"Electr. Power Syst. Res."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1049\/iet-gtd.2017.0502","article-title":"Detection and classification of micro-grid faults based on HHT and machine learning techniques","volume":"12","author":"Mishra","year":"2018","journal-title":"IET Gener. Transm. Distrib."},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Al Hanaineh, W., Matas, J., El Mariachet, J., Xie, P., Bakkar, M., and Guerrero, J.M. (2023). A THD-Based Fault Protection Method Using MSOGI-FLL Grid Voltage Estimator. Sensors, 23.","DOI":"10.3390\/s23020980"},{"key":"ref_37","unstructured":"Al Hanaineh, W., Matas, J., Bakkar, M., and Guerrero, J.M. (2023). A Robust THD Based Communication-Less Protection Method for Electrical Grids with DGs. manuscript under review."},{"key":"ref_38","unstructured":"Santoso, S., McGranaghan, M.F., Dugan, R.C., and Beaty, H.W. (2012). Electrical Power Systems Quality, McGraw-Hill Education. [3rd ed.]."},{"key":"ref_39","unstructured":"Kusko, A. (2007). Power Quality in Electrical Systems, McGraw-Hill Education."},{"key":"ref_40","first-page":"127","article-title":"Multiresonant frequency-locked loop for grid synchronization of power converters under distorted grid conditions","volume":"58","author":"Luna","year":"2010","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"Yazdani, A., and Iravani, R. (2010). Voltage-Sourced Converters in Power Systems: Modeling, Control, and Applications, John Wiley & Sons.","DOI":"10.1002\/9780470551578"},{"key":"ref_42","unstructured":"Al Hanaineh, W., Matas, J., El Mariachet, J., and Guerrero, J.M. (2022, January 6\u20137). A Harmonic-based Fault detection algorithm for Microgrids. Proceedings of the Interdisciplinary Conference on Mechanics, Computers and Electrics (ICMECE 2022), Barcelona, Spain."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"5797","DOI":"10.1109\/TPEL.2019.2953926","article-title":"A new THD measurement method with small computational burden using a SOGI-FLL grid monitoring system","volume":"35","author":"Matas","year":"2019","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_44","unstructured":"(2007). NTP-CT: Technical Conditions and Safety of EDNESA Distribution Installations, Endesa."},{"key":"ref_45","unstructured":"(2014). IEEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems (Standard No. IEEE Std 519-2014 (Revision of IEEE Std 519-1992))."},{"key":"ref_46","unstructured":"(2008). P.O.12.2: Technical Requirements of Wind Power and Photovoltaic Facilities (Draft), Red Electra."},{"key":"ref_47","unstructured":"Bollen, M.H. (2000). Voltage Sags and Interruptions, IEEE Press."},{"key":"ref_48","unstructured":"Hong, P., Turk, M., and Huang, T.S. (2000, January 28\u201330). Gesture modeling and recognition using finite state machines. Proceedings of the Fourth IEEE International Conference on Automatic Face and Gesture Recognition (Cat. No. PR00580), Grenoble, France."},{"key":"ref_49","doi-asserted-by":"crossref","unstructured":"Silos, \u00c1., Se\u00f1\u00eds, A., Mart\u00edn de Pozuelo, R., and Zaballos, A. (2017). Using IEC 61850 goose service for adaptive ANSI 67\/67N protection in ring main systems with distributed energy resources. Energies, 10.","DOI":"10.3390\/en10111685"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"1560","DOI":"10.1109\/TPWRS.2012.2185072","article-title":"Modeling of a centralized microgrid protection system and distributed energy resources according to IEC 61850-7-420","volume":"27","author":"Ustun","year":"2012","journal-title":"IEEE Trans. Power Syst."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1109\/TSG.2019.2923769","article-title":"Evaluation of a communication-assisted overcurrent protection scheme for photovoltaic-based DC microgrid","volume":"11","author":"Shabani","year":"2019","journal-title":"IEEE Trans. Smart Grid"},{"key":"ref_52","unstructured":"(2011). IEC Communications Networks and Systems in Substations (Standard No. IEC61850). Available online: https:\/\/www.google.com\/url?sa=t&rct=j&q=&esrc=s&source=web&cd=&ved=2ahUKEwi4u8Slhfr-AhW2gP0HHfh8BZcQFnoECAwQAQ&url=https%3A%2F%2Fwww.gegridsolutions.com%2Fmultilin%2Fjournals%2Fisues%2Fspring09%2Fiec61850.pdf&usg=AOvVaw2SBaCDgCisHQrtd9VF2F-i."},{"key":"ref_53","doi-asserted-by":"crossref","unstructured":"Kezunovic, M., Ren, J., and Lotfifard, S. (2016). Design, Modeling and Evaluation of Protective Relays for Power Systems, Springer International Publishing.","DOI":"10.1007\/978-3-319-20919-7"},{"key":"ref_54","doi-asserted-by":"crossref","unstructured":"Bakkar, M., Bogarra, S., C\u00f3rcoles, F., Aboelhassan, A., Wang, S., and Iglesias, J. (2022). Artificial Intelligence-Based Protection for Smart Grids. Energies, 15.","DOI":"10.3390\/en15134933"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.ref.2017.12.002","article-title":"PV based distributed generation power system protection: A review","volume":"24","author":"Bansal","year":"2018","journal-title":"Renew. Energy Focus"},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1016\/j.ijepes.2014.01.032","article-title":"An analytical literature review of the available techniques for the protection of micro-grids","volume":"58","author":"Mirsaeidi","year":"2014","journal-title":"Int. J. Electr. Power Energy Syst."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"1039","DOI":"10.1109\/TSG.2012.2190759","article-title":"Accommodating high PV penetration on distribution feeders","volume":"3","author":"Baran","year":"2012","journal-title":"IEEE Trans. Smart Grid"},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"868","DOI":"10.1109\/61.772326","article-title":"IEEE standard inverse-time characteristic equations for overcurrent relays","volume":"14","author":"Benmouyal","year":"1999","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"5217","DOI":"10.1109\/TIA.2017.2717880","article-title":"An adaptive overcurrent coordination scheme to improve relay sensitivity and overcome drawbacks due to distributed generation in smart grids","volume":"53","author":"Shih","year":"2017","journal-title":"IEEE Trans. Ind. Appl."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"62752","DOI":"10.1109\/ACCESS.2021.3074426","article-title":"User-Defined Dual Setting Directional Overcurrent Relays with Hybrid Time Current-Voltage Characteristics-Based Protection Coordination for Active Distribution Network","volume":"9","author":"Hong","year":"2021","journal-title":"IEEE Access"},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1109\/TSG.2016.2546961","article-title":"Protection coordination for microgrids with grid-connected and islanded capabilities using communication assisted dual setting directional overcurrent relays","volume":"9","author":"Sharaf","year":"2018","journal-title":"IEEE Trans. Smart Grid"},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"106844","DOI":"10.1016\/j.epsr.2020.106844","article-title":"A two stage fault current limiter and directional overcurrent relay optimization for adaptive protection resetting using differential evolution multi-objective algorithm in presence of distributed generation","volume":"190","author":"Shih","year":"2021","journal-title":"Electr. Power Syst. Res."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"e2506","DOI":"10.1002\/etep.2506","article-title":"A two-step protection algorithm for smart distribution systems with DGs","volume":"28","author":"He","year":"2018","journal-title":"Int. Trans. Electr. Energy Syst."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1049\/iet-rpg.2018.5627","article-title":"Enhancing the reliability of protection scheme for PV integrated microgrid by discriminating between array faults and symmetrical line faults using sparse auto encoder","volume":"13","author":"Manohar","year":"2019","journal-title":"IET Renew. Power Gener."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/10\/4874\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T19:37:53Z","timestamp":1760125073000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/10\/4874"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,18]]},"references-count":64,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2023,5]]}},"alternative-id":["s23104874"],"URL":"https:\/\/doi.org\/10.3390\/s23104874","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2023,5,18]]}}}