{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T06:05:58Z","timestamp":1785305158874,"version":"3.55.0"},"reference-count":39,"publisher":"MDPI AG","issue":"10","license":[{"start":{"date-parts":[[2023,5,20]],"date-time":"2023-05-20T00:00:00Z","timestamp":1684540800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"National Biopharma Mission from BIRAC","award":["BT\/NBM0030\/01\/17"],"award-info":[{"award-number":["BT\/NBM0030\/01\/17"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Endoscopy is a critical application that requires adaptable illumination to adjust to varying imaging conditions. Automatic brightness control (ABC) algorithms ensure optimal brightness throughout the image with rapid but smooth response and render the true colours of the biological tissue under examination. To achieve good image quality, high-quality ABC algorithms are necessary. In this study, we propose a three-assessment method approach for objectively evaluating ABC algorithms based on (1) image brightness and its homogeneity, (2) controller response and response time, and (3) colour rendition. We conducted an experimental study to assess the effectiveness of ABC algorithms in one commercial and two developmental endoscopy systems using the proposed methods. The results showed that the commercial system achieved good, homogeneous brightness within 0.4 s, and its damping ratio was 0.597, indicating a stable system, but its colour rendition was suboptimal. The developmental systems had control parameter values that resulted in either a sluggish response (over 1 s) or a fast (about 0.3 ms) but unstable response with damping ratios above 1, causing flickers. Our findings indicate that the interdependency among the proposed methods can establish tradeoffs in the overall ABC performance better than single-parameter approaches. The study establishes that comprehensive assessments using the proposed methods can contribute to designing new ABC algorithms and optimising already implemented ones for efficient performance in endoscopy systems.<\/jats:p>","DOI":"10.3390\/s23104932","type":"journal-article","created":{"date-parts":[[2023,5,22]],"date-time":"2023-05-22T02:28:42Z","timestamp":1684722522000},"page":"4932","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Methodological Considerations for Assessing Automatic Brightness Control in Endoscopy: Experimental Study"],"prefix":"10.3390","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7639-040X","authenticated-orcid":false,"given":"Nishitha","family":"Ravichandran","sequence":"first","affiliation":[{"name":"Department of Electrical Engineering, Indian Institute of Technology, Madras, Chennai 600036, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0634-1194","authenticated-orcid":false,"given":"Preejith","family":"Sreelatha Premkumar","sequence":"additional","affiliation":[{"name":"Healthcare Technology Innovation Centre, Indian Institute of Technology, Madras, Chennai 600113, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohanasankar","family":"Sivaprakasam","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Indian Institute of Technology, Madras, Chennai 600036, India"},{"name":"Healthcare Technology Innovation Centre, Indian Institute of Technology, Madras, Chennai 600113, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,5,20]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1109\/RBME.2011.2175445","article-title":"Computer-aided decision support systems for endoscopy in the gastrointestinal tract: A review","volume":"4","author":"Liedlgruber","year":"2011","journal-title":"IEEE Rev. Biomed. Eng."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"074010","DOI":"10.1088\/1361-6501\/ab803c","article-title":"Endoscopic single-image size measurements","volume":"31","author":"Dimas","year":"2020","journal-title":"Meas. Sci. Technol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1186\/s13638-017-0989-x","article-title":"Non-uniform illumination endoscopic imaging enhancement via anti-degraded model and L 1 L 2-based variational retinex","volume":"2017","author":"Rao","year":"2017","journal-title":"EURASIP J. Wirel. Commun. Netw."},{"key":"ref_4","unstructured":"Baumer (2022, August 26). Types of Illumination for Industrial Image Processing\u2014The Correct Light for Your Application. Available online: https:\/\/www.baumer.com\/us\/en\/service-support\/function-principle\/illumination\/a\/illumination."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Wang, L., Li, Q., Yang, H., Huang, J., and Xu, K. (2020, January 28\u201329). A Sample-Based Color Correction Method for Laparoscopic Images. Proceedings of the 2020 IEEE International Conference on Real-time Computing and Robotics (RCAR), Asahikawa, Japan.","DOI":"10.1109\/RCAR49640.2020.9303304"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1007\/s11554-011-0208-7","article-title":"Subsample-based image compression for capsule endoscopy","volume":"8","author":"Khan","year":"2013","journal-title":"J. Real-Time Image Process."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Abd-Alameer, S.A., Daway, H.G., and Rashid, H.G. (2020, January 26\u201327). Quality of medical microscope Image at different lighting condition. Proceedings of the IOP Conference Series: Materials Science and Engineering, The First International Conference of Pure and Engineering Sciences (ICPES2020), Karbala, Iraq.","DOI":"10.1088\/1757-899X\/871\/1\/012072"},{"key":"ref_8","unstructured":"Festy, F., Cook, R., and Watson, T. (2023, March 28). Automatic Exposure Control for Endoscopic Imaging. Available online: https:\/\/patents.google.com\/patent\/US10609291B2\/en."},{"key":"ref_9","unstructured":"Muehlebach, M. (2010). Camera Auto Exposure Control for VSLAM Applications, Swiss Federal Institute of Technology Zurich. Autumn Term."},{"key":"ref_10","unstructured":"Cline, R.W., Fengler, J.J.P., Figley, C.B., Dawson, R., and Jaggi, B.W. (2023, March 28). Imaging System with Automatic Gain Control for Reflectance and Fluorescence Endoscopy. Available online: https:\/\/patents.google.com\/patent\/US6462770B1\/en."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1266","DOI":"10.1111\/coa.13139","article-title":"The effect of light intensity on image quality in endoscopic ear surgery","volume":"43","author":"McCallum","year":"2018","journal-title":"Clin. Otolaryngol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"884","DOI":"10.1109\/TBCAS.2016.2546838","article-title":"Automated adaptive brightness in wireless capsule endoscopy using image segmentation and sigmoid function","volume":"10","author":"Shrestha","year":"2016","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"102920","DOI":"10.1016\/j.micpro.2019.102920","article-title":"Automatic illumination control for an endoscopy sensor","volume":"72","author":"Sousa","year":"2020","journal-title":"Microprocess. Microsyst."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"6062","DOI":"10.1109\/TII.2020.3035448","article-title":"No-reference image contrast evaluation by generating bidirectional pseudoreferences","volume":"17","author":"Jiang","year":"2020","journal-title":"IEEE Trans. Ind. Inform."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"e2396","DOI":"10.1002\/rcs.2396","article-title":"Endoscopic image luminance enhancement based on the inverse square law for illuminance and retinex","volume":"18","author":"Wang","year":"2022","journal-title":"Int. J. Med. Robot. Comput. Assist. Surg."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Yue, G., Cheng, D., Zhou, T., Hou, J., Liu, W., Xu, L., Wang, T., and Cheng, J. (2023). Perceptual Quality Assessment of Enhanced Colonoscopy Images: A Benchmark Dataset and an Objective Method. IEEE Trans. Circuits Syst. Video Technol.","DOI":"10.1109\/TCSVT.2023.3260212"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1016\/j.sna.2011.01.010","article-title":"An FPGA-based versatile development system for endoscopic capsule design optimization","volume":"172","author":"Cavallotti","year":"2011","journal-title":"Sens. Actuators A Phys."},{"key":"ref_18","unstructured":"Nishitha, R., Amalan, S., Sharma, S., Gurrala, A.K., Preejith, S., Joseph, J., and Sivaprakasam, M. (2021, January 23\u201325). Image Quality Assessment for Endoscopy Applications. Proceedings of the 2021 IEEE International Symposium on Medical Measurements and Applications (MeMeA), Lausanne, Switzerland."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"60820H","DOI":"10.1117\/12.648497","article-title":"Optical quality assessment of rigid endoscopes during clinical lifetime","volume":"Volume 6082","author":"Noordmans","year":"2006","journal-title":"Proceedings of the Endoscopic Microscopy"},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"R, N., S, A., P, P.S., and Sivaprakasam, M. (2022, January 22\u201324). Identification of Structures to Perform Image Quality Assessment in Real-Time Endoscopy Imaging. Proceedings of the 2022 IEEE International Symposium on Medical Measurements and Applications (MeMeA), Messina, Italy.","DOI":"10.1109\/MeMeA54994.2022.9856437"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Nishitha, R., Amalan, S., Sharma, S., Preejith, S.P., and Sivaprakasam, M. (2022, January 22\u201324). Image Quality Assessment for Interdependent Image Parameters Using a Score-Based Technique for Endoscopy Applications. Proceedings of the 2022 IEEE International Symposium on Medical Measurements and Applications (MeMeA), Messina, Italy.","DOI":"10.1109\/MeMeA54994.2022.9856448"},{"key":"ref_22","unstructured":"Imatest (2022, August 30). Reflective Chart Quality Comparison: Inkjet vs. Photographic. Available online: https:\/\/www.imatest.com\/2013\/11\/reflective-chart-quality-comparisoninkjet-vs-photographic\/."},{"key":"ref_23","unstructured":"Auxomedical (2022, August 30). Olympus CV-190 and CLV-190 Video Processor and Light Source. Available online: https:\/\/auxomedical.com\/products\/olympus-cv-190-and-clv-190-video-processor-and-light-source\/."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"354006","DOI":"10.1088\/0022-3727\/43\/35\/354006","article-title":"Colour-rendition properties of solid-state lamps","volume":"43","author":"Vaicekauskas","year":"2010","journal-title":"J. Phys. D Appl. Phys."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1186\/s41074-018-0040-0","article-title":"A histogram specification technique for dark image enhancement using a local transformation method","volume":"10","author":"Hussain","year":"2018","journal-title":"IPSJ Trans. Comput. Vis. Appl."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1926","DOI":"10.1109\/TIM.2005.853231","article-title":"Transient response for automatic gain control with multiple intensity thresholds for image-intensified camera","volume":"54","author":"Fowler","year":"2005","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_27","unstructured":"Alciatore, D.G., and Histand, M.B. (2007). Introduction to Mechatronics and Measurement Systems, McGraw-Hill."},{"key":"ref_28","unstructured":"Inman, D.J., and Singh, R.C. (1994). Engineering Vibration, Prentice Hall."},{"key":"ref_29","unstructured":"Mike Bedard, S.B. (2022, August 26). What Is a Vectorscope? How They Work and Why You Need One. Available online: https:\/\/www.studiobinder.com\/blog\/what-is-a-vectorscope-definition\/."},{"key":"ref_30","unstructured":"Tektronix (2022, August 26). NTSC Video Measurements. Available online: https:\/\/download.tek.com\/document\/25W_7247_1_rfs.pdf."},{"key":"ref_31","first-page":"188","article-title":"Homogeneous LED-illumination using microlens arrays","volume":"Volume 5942","author":"Schreiber","year":"2005","journal-title":"Proceedings of the Nonimaging Optics and Efficient Illumination Systems II"},{"key":"ref_32","unstructured":"Design, V.S. (2022, August 26). An Illumination Profile. Available online: https:\/\/www.vision-systems.com\/cameras-accessories\/article\/16739191\/an-illuminating-profile."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1392","DOI":"10.21105\/joss.01392","article-title":"Optimising Light Source Positioning for Even and Flux-Efficient Illumination","volume":"4","author":"Taylor","year":"2019","journal-title":"J. Open Source Softw."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1016\/j.pdpdt.2016.08.010","article-title":"Illumination profile characterization of a light device for the dosimetry of intra-pleural photodynamic therapy for mesothelioma","volume":"16","author":"Munck","year":"2016","journal-title":"Photodiagn. Photodyn. Ther."},{"key":"ref_35","unstructured":"Boyce, M.P. (2012). Gas Turbine Engineering Handbook, Butterworth-Heinemann. [4th ed.]."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"1287","DOI":"10.1016\/S1474-6670(17)57843-X","article-title":"Tracking control with a smooth transient response","volume":"29","author":"Holmberg","year":"1996","journal-title":"IFAC Proc. Vol."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1016\/S0168-9002(99)01093-1","article-title":"Analysis of the transient response of LED-illuminated diodes under heavy radiation damage","volume":"443","author":"Passeri","year":"2000","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip."},{"key":"ref_38","unstructured":"all2md (2022, September 12). How to Solve the 5 Most Common Endoscopy Camera Problems by Yourself. Available online: https:\/\/all2md.com\/how-to-solve-the-5-most-common-endoscopy-camera-problems-by-yourself\/."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1109\/TAC.1965.1098213","article-title":"The damping ratio of an optimal control system","volume":"10","author":"Jacobs","year":"1965","journal-title":"IEEE Trans. Autom. Control"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/10\/4932\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T19:39:09Z","timestamp":1760125149000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/10\/4932"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,20]]},"references-count":39,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2023,5]]}},"alternative-id":["s23104932"],"URL":"https:\/\/doi.org\/10.3390\/s23104932","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,5,20]]}}}