{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,20]],"date-time":"2026-11-20T21:31:40Z","timestamp":1795210300964,"version":"4.10.3"},"reference-count":114,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2023,6,3]],"date-time":"2023-06-03T00:00:00Z","timestamp":1685750400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The atomic magnetometer is currently one of the most-sensitive sensors and plays an important role in applications for detecting weak magnetic fields. This review reports the recent progress of total-field atomic magnetometers that are one important ramification of such magnetometers, which can reach the technical level for engineering applications. The alkali-metal magnetometers, helium magnetometers, and coherent population-trapping magnetometers are included in this review. Besides, the technology trend of atomic magnetometers was analyzed for the purpose of providing a certain reference for developing the technologies in such magnetometers and for exploring their applications.<\/jats:p>","DOI":"10.3390\/s23115318","type":"journal-article","created":{"date-parts":[[2023,6,5]],"date-time":"2023-06-05T02:18:29Z","timestamp":1685931509000},"page":"5318","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":65,"title":["Recent Progress of Atomic Magnetometers for Geomagnetic Applications"],"prefix":"10.3390","volume":"23","author":[{"given":"Yuantian","family":"Lu","sequence":"first","affiliation":[{"name":"Aerospace Information Research Institute, Chinese Academy of Sciences, No. 9 Dengzhuang South Road, Beijing 100094, China"},{"name":"School of Electronic, Electrical and Communication Engineering, University of the Chinese Academy of Sciences, Beijing 100049, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tian","family":"Zhao","sequence":"additional","affiliation":[{"name":"Aerospace Information Research Institute, Chinese Academy of Sciences, No. 9 Dengzhuang South Road, Beijing 100094, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wanhua","family":"Zhu","sequence":"additional","affiliation":[{"name":"Aerospace Information Research Institute, Chinese Academy of Sciences, No. 9 Dengzhuang South Road, Beijing 100094, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leisong","family":"Liu","sequence":"additional","affiliation":[{"name":"Aerospace Information Research Institute, Chinese Academy of Sciences, No. 9 Dengzhuang South Road, Beijing 100094, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7605-2363","authenticated-orcid":false,"given":"Xin","family":"Zhuang","sequence":"additional","affiliation":[{"name":"Aerospace Information Research Institute, Chinese Academy of Sciences, No. 9 Dengzhuang South Road, Beijing 100094, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guangyou","family":"Fang","sequence":"additional","affiliation":[{"name":"Aerospace Information Research Institute, Chinese Academy of Sciences, No. 9 Dengzhuang South Road, Beijing 100094, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaojuan","family":"Zhang","sequence":"additional","affiliation":[{"name":"Aerospace Information Research Institute, Chinese Academy of Sciences, No. 9 Dengzhuang South Road, Beijing 100094, China"},{"name":"School of Electronic, Electrical and Communication Engineering, University of the Chinese Academy of Sciences, Beijing 100049, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,6,3]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1111\/1365-2478.12914","article-title":"High-resolution unmanned aerial vehicle aeromagnetic surveys for mineral exploration targets","volume":"68","author":"Walter","year":"2020","journal-title":"Geophys. Prospect."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Kolster, M.E., Wigh, M.D., Lima Sim\u00f5es da Silva, E., Bjerg Vilhelmsen, T., and D\u00f8ssing, A. (2022). High-Speed Magnetic Surveying for Unexploded Ordnance Using UAV Systems. Remote Sens., 14.","DOI":"10.3390\/rs14051134"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.jas.2015.02.023","article-title":"Seeing beneath the farmland, steppe and desert soil: Magnetic prospecting and soil magnetism","volume":"56","author":"Fassbinder","year":"2015","journal-title":"J. Archaeol. Sci."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1002\/arp.1843","article-title":"Rock magnetic study of grave infill as a key to understanding magnetic anomalies on burial ground","volume":"29","author":"Bondar","year":"2022","journal-title":"Archaeol Prospect."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1186\/s40623-015-0231-1","article-title":"In-flight performance of the Absolute Scalar Magnetometer vector mode on board the Swarm satellites","volume":"67","author":"Jager","year":"2015","journal-title":"Earth Planets Space"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Bennett, J.S., Vyhnalek, B.E., Greenall, H., Bridge, E.M., Gotardo, F., Forstner, S., Harris, G.I., Miranda, F.A., and Bowen, W.P. (2021). Precision Magnetometers for Aerospace Applications: A Review. Sensors, 21.","DOI":"10.3390\/s21165568"},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Labyt, E., Sander, T., and Wakai, R. (2022). Flexible High Performance Magnetic Field Sensors: On-Scalp Magnetoencephalography and Other Applications, Springer International Publishing.","DOI":"10.1007\/978-3-031-05363-4"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1038\/nphys566","article-title":"Optical magnetometry","volume":"3","author":"Budker","year":"2007","journal-title":"Nat. Phys."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"5294","DOI":"10.1109\/TMAG.2013.2264821","article-title":"An Optimization Method for Induction Magnetometer of 0.1 mHz to 1 kHz","volume":"49","author":"Yan","year":"2013","journal-title":"IEEE Trans. Magn."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Elson, L., Meraki, A., Rushton, L.M., Pyragius, T., and Jensen, K. (2022). Detection and Characterisation of Conductive Objects Using Electromagnetic Induction and a Fluxgate Magnetometer. Sensors, 22.","DOI":"10.3390\/s22165934"},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Wei, S., Liao, X., Zhang, H., Pang, J., and Zhou, Y. (2021). Recent Progress of Fluxgate Magnetic Sensors: Basic Research and Application. Sensors, 21.","DOI":"10.3390\/s21041500"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1016\/j.measurement.2018.10.016","article-title":"A frequency measurement method based on optimal multi-average for increasing proton magnetometer measurement precision","volume":"135","author":"Tan","year":"2019","journal-title":"Measurement"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"101101","DOI":"10.1063\/1.2354545","article-title":"Superconducting quantum interference device instruments and applications","volume":"77","author":"Fagaly","year":"2006","journal-title":"Rev. Sci. Instrum."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Vettoliere, A., and Granata, C. (2023). Highly Sensitive Tunable Magnetometer Based on Superconducting Quantum Interference Device. Sensors, 23.","DOI":"10.3390\/s23073558"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Schulz, L., Heinisch, P., and Richter, I. (2019). Calibration of Off-the-Shelf Anisotropic Magnetoresistance Magnetometers. Sensors, 19.","DOI":"10.3390\/s19081850"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"204501","DOI":"10.1063\/5.0151569","article-title":"Parallel array of planar Hall effect sensors for high resolution magnetometry","volume":"133","author":"Nhalil","year":"2023","journal-title":"J. Appl. Phys."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.vrih.2022.01.003","article-title":"Giant magneto-impedance sensor with working point selfadaptation for unshielded human bio-magnetic detection","volume":"4","author":"Han","year":"2022","journal-title":"Virtual Real. Intell. Hardw."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1038\/055347a0","article-title":"The Effect of Magnetisation on the Nature of Light Emitted by a Substance","volume":"55","author":"Zeeman","year":"1897","journal-title":"Nature"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1038\/166113a0","article-title":"Applications of Polarimetry to Infra-Red and Micro-Wave Spectroscopy","volume":"166","author":"Kastler","year":"1950","journal-title":"Nature"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1364\/JOSA.47.000460","article-title":"Optical Methods of Atomic Orientation and of Magnetic Resonance","volume":"47","author":"Kastler","year":"1957","journal-title":"J. Opt. Soc. Am."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1924","DOI":"10.1103\/PhysRev.105.1924","article-title":"Modulation of a Light Beam by Precessing Absorbing Atoms","volume":"105","author":"Dehmelt","year":"1957","journal-title":"Phys. Rev."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1559","DOI":"10.1103\/PhysRev.107.1559","article-title":"Optical Detection of Magnetic Resonance in Alkali Metal Vapor","volume":"107","author":"Bell","year":"1957","journal-title":"Phys. Rev."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1103\/PhysRevLett.6.280","article-title":"Optically Driven Spin Precession","volume":"6","author":"Bell","year":"1961","journal-title":"Phys. Rev. Lett."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1364\/AO.1.000061","article-title":"Principles of Operation of the Rubidium VaporMagnetometer","volume":"1","author":"Bloom","year":"1962","journal-title":"Appl. Opt."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1103\/PhysRevLett.1.316","article-title":"Alignment of Metastable Helium Atoms by Unpolarized Resonance Radiation","volume":"1","author":"Franken","year":"1958","journal-title":"Phys. Rev. Lett."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"680","DOI":"10.1103\/PhysRev.119.680","article-title":"Optical Pumping of Helium in the 3S1 Metastable State","volume":"119","author":"Colegrove","year":"1960","journal-title":"Phys. Rev."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1153","DOI":"10.1103\/RevModPhys.74.1153","article-title":"Resonant nonlinear magneto-optical effects in atoms","volume":"74","author":"Budker","year":"2002","journal-title":"Rev. Mod. Phys."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1103\/PhysRevLett.31.273","article-title":"Spin-Exchange Shift and Narrowing of Magnetic Resonance Lines in Optically Pumped Alkali Vapors","volume":"31","author":"Happer","year":"1973","journal-title":"Phys. Rev. Lett."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1877","DOI":"10.1103\/PhysRevA.16.1877","article-title":"Effect of rapid spin exchange on the magnetic-resonance spectrum of alkali vapors","volume":"16","author":"Happer","year":"1977","journal-title":"Phys. Rev. A"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"130801","DOI":"10.1103\/PhysRevLett.89.130801","article-title":"High-sensitivity atomic magnetometer unaffected by spin exchange relaxation","volume":"89","author":"Allred","year":"2002","journal-title":"Phys. Rev. Lett."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"151110","DOI":"10.1063\/1.3491215","article-title":"Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer","volume":"97","author":"Dang","year":"2010","journal-title":"Appl. Phys. Lett."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"18300","DOI":"10.1364\/OE.458367","article-title":"Three-axis closed-loop optically pumped magnetometer operated in the SERF regime","volume":"30","author":"Yan","year":"2022","journal-title":"Opt. Express"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"023103","DOI":"10.1063\/1.4974845","article-title":"A rubidium Mx-magnetometer for measurements on solid state spins","volume":"88","author":"Arnold","year":"2017","journal-title":"Rev. Sci. Instrum."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1007\/s00340-005-1773-x","article-title":"Comparison of discharge lamp and laser pumped cesium magnetometers","volume":"80","author":"Groeger","year":"2005","journal-title":"Appl. Phys. B"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"3604","DOI":"10.1364\/AO.457087","article-title":"Vector magnetometer based on the effect of coherent population trapping","volume":"61","author":"Andryushkov","year":"2022","journal-title":"Appl. Opt."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"113928","DOI":"10.1016\/j.sna.2022.113928","article-title":"Optimal buffer gas pressure in dual-beam spin exchange relaxation-free magnetometers","volume":"347","author":"Lu","year":"2022","journal-title":"Sens. Actuators Phys."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"2187","DOI":"10.1364\/OE.25.002187","article-title":"Lifetime assessment of RbN3-filled MEMS atomic vapor cells with Al2O3 coating","volume":"25","author":"Karlen","year":"2017","journal-title":"Opt. Express"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1364\/JOSAB.22.000077","article-title":"Optimization and performance of an optical cardiomagnetometer","volume":"22","author":"Bison","year":"2005","journal-title":"J. Opt. Soc. Am. B"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"110704","DOI":"10.1016\/j.measurement.2022.110704","article-title":"A kilohertz bandwidth and sensitive scalar atomic magnetometer using an optical multipass cell","volume":"190","author":"Li","year":"2022","journal-title":"Measurement"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"105005","DOI":"10.1063\/5.0062791","article-title":"A 4He vector zero-field optically pumped magnetometer operated in the Earth-field","volume":"92","author":"Bertrand","year":"2021","journal-title":"Rev. Sci. Instrum."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"043110","DOI":"10.1103\/PhysRevA.107.043110","article-title":"Partial measurements of the total field gradient and the field-gradient tensor using an atomic magnetic gradiometer","volume":"107","author":"Yu","year":"2023","journal-title":"Phys. Rev. A"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"043109","DOI":"10.1103\/PhysRevA.105.043109","article-title":"All-optical spin locking in alkali-metal-vapor magnetometers","volume":"105","author":"Bao","year":"2022","journal-title":"Phys. Rev. A"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"7007710","DOI":"10.1109\/TIM.2022.3214621","article-title":"4He Optically Pumped Magnetometer With RF Field Modulation and Light Stabilization in Deep Well for Earthquake Monitoring","volume":"71","author":"Zhang","year":"2022","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"024034","DOI":"10.1103\/PhysRevApplied.17.024034","article-title":"Integrated Optically Pumped Magnetometer for Measurements within Earth\u2019s Magnetic Field","volume":"17","author":"Oelsner","year":"2022","journal-title":"Phys. Rev. Applied"},{"key":"ref_45","doi-asserted-by":"crossref","unstructured":"Gutteling, T.P., Bonnefond, M., Clausner, T., Daligault, S., Romain, R., Mitryukovskiy, S., Fourcault, W., Josselin, V., Le Prado, M., and Palacios-Laloy, A. (2023). A New Generation of OPM for High Dynamic and Large Bandwidth MEG: The 4He OPMs\u2014First Applications in Healthy Volunteers. Sensors, 23.","DOI":"10.3390\/s23052801"},{"key":"ref_46","unstructured":"Pati, G., Tripathi, R., Pulido, M., and Suarez, M. (2022). Frontiers in Optics + Laser Science 2022 (FIO, LS), Optica Publishing Group."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"112733","DOI":"10.1016\/j.measurement.2023.112733","article-title":"Parameter optimisation of miniaturised SERF magnetometer below relaxation rate saturation region","volume":"214","author":"Li","year":"2023","journal-title":"Measurement"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"31752","DOI":"10.1364\/OE.467513","article-title":"Repumping atomic media for an enhanced sensitivity atomic magnetometer","volume":"30","author":"Li","year":"2022","journal-title":"Opt. Express"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"064067","DOI":"10.1103\/PhysRevApplied.14.064067","article-title":"Continuous High-Sensitivity and High-Bandwidth Atomic Magnetometer","volume":"14","author":"Li","year":"2020","journal-title":"Phys. Rev. Appl."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1103\/PhysRev.70.460","article-title":"Nuclear Induction","volume":"70","author":"Bloch","year":"1946","journal-title":"Phys. Rev."},{"key":"ref_51","unstructured":"(2013). Optical Magnetometry, Cambridge University Press."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"165510","DOI":"10.1016\/j.ijleo.2020.165510","article-title":"Parameters optimization of optical pumped Mz\/Mx magnetometer based on rf-discharge lamp","volume":"223","author":"Ke","year":"2020","journal-title":"Optik"},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"544","DOI":"10.1088\/0950-7671\/41\/9\/305","article-title":"A self-oscillating rubidium vapour magnetometer for geomagnetic measurements","volume":"41","author":"Usher","year":"1964","journal-title":"J. Sci. Instrum."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"924","DOI":"10.1134\/S1063784206070188","article-title":"Optically pumped quantum MX magnetometers: Digital measurement of the MX resonance frequency in a rapidly varying field","volume":"51","author":"Pazgalev","year":"2006","journal-title":"Tech. Phys."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"1482","DOI":"10.1364\/JOSAB.24.001482","article-title":"All optical sensor for automated magnetometry based on coherent population trapping","volume":"24","author":"Belfi","year":"2007","journal-title":"J. Opt. Soc. Am. B"},{"key":"ref_56","doi-asserted-by":"crossref","unstructured":"Preusser, J., Knappe, S., Kitching, J., and Gerginov, V. (2009, January 20\u201324). A microfabricated photonic magnetometer. Proceedings of the 2009 IEEE International Frequency Control Symposium Joint with the 22nd European Frequency and Time Forum, Besancon, France.","DOI":"10.1109\/FREQ.2009.5168385"},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"596","DOI":"10.1038\/nature01484","article-title":"A subfemtotesla multichannel atomic magnetometer","volume":"422","author":"Kominis","year":"2003","journal-title":"Nature"},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"023405","DOI":"10.1103\/PhysRevA.71.023405","article-title":"Effects of spin exchange collisions in a high-density alkali-metal vapor in low magnetic fields","volume":"71","author":"Savukov","year":"2005","journal-title":"Phys. Rev. A"},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"1216","DOI":"10.1111\/j.1365-246X.2010.04804.x","article-title":"International Geomagnetic Reference Field: The eleventh generation","volume":"183","author":"Finlay","year":"2010","journal-title":"Geophys. J. Int."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"B12103","DOI":"10.1029\/2005JB003837","article-title":"Geological modeling of the new CHAMP magnetic anomaly maps using a geographical information system technique","volume":"110","author":"Hemant","year":"2005","journal-title":"J. Geophys. Res. Solid Earth"},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1016\/j.jappgeo.2005.06.004","article-title":"Soil anomaly mapping using a caesium magnetometer: Limits in the low magnetic amplitude case","volume":"58","author":"Chevallier","year":"2006","journal-title":"J. Appl. Geophys."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1016\/j.jappgeo.2010.09.005","article-title":"Interpretation of high-resolution low-altitude helicopter magnetometer surveys over sites contaminated with unexploded ordnance","volume":"72","author":"Billings","year":"2010","journal-title":"J. Appl. Geophys."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.sna.2005.09.036","article-title":"Laser-pumped cesium magnetometers for high-resolution medical and fundamental research","volume":"129","author":"Groeger","year":"2006","journal-title":"Sens. Actuators Phys."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"918","DOI":"10.1088\/0957-0233\/15\/5\/020","article-title":"Three-component variometer based on a scalar potassium sensor","volume":"15","author":"Alexandrov","year":"2004","journal-title":"Meas. Sci. Technol."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"045002","DOI":"10.1088\/1361-6455\/acb1e5","article-title":"Searching for alignment-to-orientation conversion in the ground-state of atomic Cs with circularly polarized laser probe","volume":"56","author":"Mozers","year":"2023","journal-title":"J. Phys. B Mol. Opt. Phys."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"100701","DOI":"10.1088\/0256-307X\/29\/10\/100701","article-title":"A High Sensitivity Laser-Pumped Cesium Magnetometer","volume":"29","author":"Huang","year":"2012","journal-title":"Chin. Phys. Lett."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"058501","DOI":"10.1088\/0256-307X\/34\/5\/058501","article-title":"All-Optical Vector Cesium Magnetometer","volume":"34","author":"Sun","year":"2017","journal-title":"Chin. Phys. Lett."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"084101","DOI":"10.1063\/5.0039565","article-title":"Quantitative analysis of magnetic cobalt particles with an optically pumped atomic magnetometer","volume":"118","author":"Bi","year":"2021","journal-title":"Appl. Phys. Lett."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"081102","DOI":"10.1063\/1.2709532","article-title":"Chip-scale atomic magnetometer with improved sensitivity by use of the Mx technique","volume":"90","author":"Schwindt","year":"2007","journal-title":"Appl. Phys. Lett."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"7870","DOI":"10.1002\/2016JA022389","article-title":"Miniature atomic scalar magnetometer for space based on the rubidium isotope 87Rb","volume":"121","author":"Korth","year":"2016","journal-title":"J. Geophys. Res. Space Phys."},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1038\/s41377-021-00499-5","article-title":"Demonstration of an integrated nanophotonic chip-scale alkali vapor magnetometer using inverse design","volume":"10","author":"Sebbag","year":"2021","journal-title":"Light Sci. Appl."},{"key":"ref_72","unstructured":"Geometrics (2023, April 26). Magnetometers. Available online: https:\/\/www.geometrics.com\/magnetometers\/."},{"key":"ref_73","unstructured":"CAE (2023, April 26). Magnetic Anomaly Detection-Extended Role. Available online: https:\/\/www.cae.com\/defense-security\/what-we-do\/mission-operations-support\/magnetic-anomaly-detection-extended-role-mad-xr\/."},{"key":"ref_74","unstructured":"GEM (2023, April 26). Potassium Magnetometer for High Precision and Accuracy. Available online: https:\/\/www.gemsys.ca\/ultra-high-sensitivity-potassium\/."},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.1088\/0957-0233\/10\/11\/309","article-title":"A new optically pumped tandem magnetometer: Principles and experiences","volume":"10","author":"Pulz","year":"1999","journal-title":"Meas. Sci. Technol."},{"key":"ref_76","unstructured":"Geometrics (2023, April 26). MFAM Developer Kit. Available online: https:\/\/www.geometrics.com\/product\/mfam-developer-kit\/."},{"key":"ref_77","unstructured":"QUSPIN (2023, April 26). QTFM Gen-2. Available online: https:\/\/quspin.com\/qtfm-gen-2\/."},{"key":"ref_78","unstructured":"TWINLEAF (2023, April 26). OMG Optical Magnetic Gradiometer. Available online: https:\/\/twinleaf.com\/scalar\/OMG\/."},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"011002","DOI":"10.1103\/PhysRevApplied.14.011002","article-title":"Portable magnetometry for detection of biomagnetism in ambient environments","volume":"14","author":"Limes","year":"2020","journal-title":"Phys. Rev. Appl."},{"key":"ref_80","doi-asserted-by":"crossref","unstructured":"Grosz, A., Haji-Sheikh, M.J., and Mukhopadhyay, S.C. (2017). High Sensitivity Magnetometers, Springer International Publishing.","DOI":"10.1007\/978-3-319-34070-8"},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"30129","DOI":"10.1029\/2001JA900115","article-title":"Scalar helium magnetometer observations at Cassini Earth swing-by","volume":"106","author":"Smith","year":"2001","journal-title":"J. Geophys. Res. Space Phys."},{"key":"ref_82","doi-asserted-by":"crossref","first-page":"1134","DOI":"10.1109\/LGRS.2019.2940824","article-title":"Aeromagnetic Compensation With Suppressing Heading Error of the Scalar Atomic Magnetometer","volume":"17","author":"Wang","year":"2020","journal-title":"IEEE Geosci. Remote Sens. Lett."},{"key":"ref_83","doi-asserted-by":"crossref","first-page":"4163","DOI":"10.1029\/JZ066i012p04163","article-title":"A metastable helium magnetometer for observing small geomagnetic fluctuations","volume":"66","author":"Keyser","year":"1961","journal-title":"J. Geophys. Res."},{"key":"ref_84","unstructured":"POLATOMIC (2023, April 26). Magnetometers. Available online: http:\/\/www.polatomic.com\/magnetometers.html."},{"key":"ref_85","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1007\/s11214-004-1432-2","article-title":"The Cassini Magnetic Field Investigation","volume":"114","author":"Dougherty","year":"2004","journal-title":"Space Sci. Rev."},{"key":"ref_86","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1007\/s11214-010-9676-5","article-title":"Measuring the Earth\u2019s Magnetic Field from Space: Concepts of Past, Present and Future Missions","volume":"155","author":"Olsen","year":"2010","journal-title":"Space Sci. Rev."},{"key":"ref_87","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/0030-4018(94)00645-B","article-title":"A new optical pumping scheme using a frequency modulated semi-conductor laser for 4He magnetometers","volume":"115","author":"Gilles","year":"1995","journal-title":"Opt. Commun."},{"key":"ref_88","doi-asserted-by":"crossref","first-page":"2253","DOI":"10.1063\/1.1364667","article-title":"Laser pumped 4He magnetometer","volume":"72","author":"Gilles","year":"2001","journal-title":"Rev. Sci. Instrum."},{"key":"ref_89","first-page":"1735","article-title":"Improvement of the Spatial Amplitude Isotropy of a 4He Magnetometer Using a Modulated Pumping Beam","volume":"7","author":"Gilles","year":"1997","journal-title":"J. Phys. III"},{"key":"ref_90","doi-asserted-by":"crossref","first-page":"634","DOI":"10.1016\/j.proche.2009.07.158","article-title":"Swarm Absolute Scalar and Vector Magnetometer Based on Helium 4 Optical Pumping","volume":"1","author":"Leger","year":"2009","journal-title":"Procedia Chem."},{"key":"ref_91","unstructured":"Survey, C.G. (2023, April 26). Airborne Geophysical Equipment, Available online: http:\/\/www.agrs.cgs.gov.cn\/jszb\/201608\/t20160818372157.html."},{"key":"ref_92","doi-asserted-by":"crossref","first-page":"15081","DOI":"10.1364\/OE.390375","article-title":"All-optical self-oscillating 4He atomic mangnetometer with optical phase shift","volume":"28","author":"Wang","year":"2020","journal-title":"Opt. Express"},{"key":"ref_93","unstructured":"Pati, G., Barrios, B., Depto, R., Tripathi, R., Yu, A., and Krainak, M. (2018). Frontiers in Optics\/Laser Science, Optica Publishing Group. OSA Technical Digest."},{"key":"ref_94","doi-asserted-by":"crossref","first-page":"193601","DOI":"10.1103\/PhysRevLett.105.193601","article-title":"Dead-Zone-Free Atomic Magnetometry with Simultaneous Excitation of Orientation and Alignment Resonances","volume":"105","author":"Romalis","year":"2010","journal-title":"Phys. Rev. Lett."},{"key":"ref_95","doi-asserted-by":"crossref","first-page":"6409","DOI":"10.1063\/1.1839274","article-title":"Chip-scale atomic magnetometer","volume":"85","author":"Schwindt","year":"2004","journal-title":"Appl. Phys. Lett."},{"key":"ref_96","doi-asserted-by":"crossref","unstructured":"Pollinger, A., Lammegger, R., Magnes, W., Ellmeier, M., Baumjohann, W., and Windholz, L. (2010, January 1\u20134). Control loops for a Coupled Dark State Magnetometer. Proceedings of the SENSORS, 2010 IEEE, Waikoloa, HI, USA.","DOI":"10.1109\/ICSENS.2010.5690766"},{"key":"ref_97","doi-asserted-by":"crossref","unstructured":"Hong, H.G., Park, S.E., Lee, S.B., Heo, M.S., Park, J., Kim, T.H., Kim, H.Y., and Kwon, T.Y. (2021). Chip-Scale Ultra-Low Field Atomic Magnetometer Based on Coherent Population Trapping. Sensors, 21.","DOI":"10.3390\/s21041517"},{"key":"ref_98","doi-asserted-by":"crossref","first-page":"095103","DOI":"10.1088\/1361-6501\/aacde4","article-title":"Coupled dark state magnetometer for the China Seismo-Electromagnetic Satellite","volume":"29","author":"Pollinger","year":"2018","journal-title":"Meas. Sci. Technol."},{"key":"ref_99","doi-asserted-by":"crossref","first-page":"100606","DOI":"10.1016\/j.measen.2022.100606","article-title":"Frequency shift compensation for single and dual laser beam pass sensors of a coherent population trapping resonance based coupled dark state magnetometer","volume":"25","author":"Ellmeier","year":"2023","journal-title":"Meas. Sensors"},{"key":"ref_100","doi-asserted-by":"crossref","first-page":"2466","DOI":"10.1109\/COMST.2019.2897610","article-title":"A Survey of Underwater Magnetic Induction Communications: Fundamental Issues, Recent Advances, and Challenges","volume":"21","author":"Li","year":"2019","journal-title":"IEEE Commun. Surv. Tutor."},{"key":"ref_101","doi-asserted-by":"crossref","first-page":"1139","DOI":"10.1109\/36.927427","article-title":"Multisensor towed array detection system for UXO detection","volume":"39","author":"Nelson","year":"2001","journal-title":"IEEE Trans. Geosci. Remote Sens."},{"key":"ref_102","doi-asserted-by":"crossref","unstructured":"Jin, K., Geng, X., Liang, Z., Tang, W., Xiao, J., Hu, H., Huang, G., Li, G., Yang, G., and Liang, S. (2022). Design of Portable Self-Oscillating VCSEL-Pumped Cesium Atomic Magnetometer. Electronics, 11.","DOI":"10.3390\/electronics11223666"},{"key":"ref_103","doi-asserted-by":"crossref","first-page":"4384","DOI":"10.1364\/OME.462911","article-title":"Spin relaxation of rubidium atoms in an octadecyltrichlorosilane anti-relaxation and anti-reflection coated vacuum multipass cell","volume":"12","author":"Li","year":"2022","journal-title":"Opt. Mater. Express"},{"key":"ref_104","doi-asserted-by":"crossref","first-page":"034066","DOI":"10.1103\/PhysRevApplied.19.034066","article-title":"Dual-Species All-Optical Magnetometer Based on a Cs-K Hybrid Vapor Cell","volume":"19","author":"Ding","year":"2023","journal-title":"Phys. Rev. Appl."},{"key":"ref_105","doi-asserted-by":"crossref","unstructured":"Jiqing, F., He, W., Xiang, P., and Wei, Z. (2018, January 8\u201313). A Laser-Pumped Cs-4He Magnetometer for Metrology. Proceedings of the 2018 Conference on Precision Electromagnetic Measurements (CPEM 2018), Paris, France.","DOI":"10.1109\/CPEM.2018.8501178"},{"key":"ref_106","doi-asserted-by":"crossref","first-page":"L021001","DOI":"10.1103\/PhysRevApplied.18.L021001","article-title":"Femtotesla Nearly-Quantum-Noise-Limited Pulsed Gradiometer at Earth-Scale Fields","volume":"18","author":"Lucivero","year":"2022","journal-title":"Phys. Rev. Appl."},{"key":"ref_107","doi-asserted-by":"crossref","first-page":"eaba8792","DOI":"10.1126\/sciadv.aba8792","article-title":"Recording brain activities in unshielded Earth\u2019s field with optically pumped atomic magnetometers","volume":"6","author":"Zhang","year":"2020","journal-title":"Sci. Adv."},{"key":"ref_108","doi-asserted-by":"crossref","first-page":"2998","DOI":"10.1364\/JOSAB.471677","article-title":"Improving sensitivity of an amplitude-modulated magneto-optical atomic magnetometer using squeezed light","volume":"39","author":"Li","year":"2022","journal-title":"J. Opt. Soc. Am. B"},{"key":"ref_109","doi-asserted-by":"crossref","unstructured":"Zheng, Y., Li, S., Xing, K., and Zhang, X. (2021). Unmanned Aerial Vehicles for Magnetic Surveys: A Review on Platform Selection and Interference Suppression. Drones, 5.","DOI":"10.3390\/drones5030093"},{"key":"ref_110","doi-asserted-by":"crossref","unstructured":"Liu, X., Hu, Y., Li, Y., Wu, X., Chang, M., and Zhang, X. (2022). Design of a Fiber Alkali Vapor Cell for Atomic Magnetometer for Magnetoencephalography Applications. Photonics, 9.","DOI":"10.3390\/photonics9100749"},{"key":"ref_111","doi-asserted-by":"crossref","unstructured":"Eleftherakis, D., and Vicen-Bueno, R. (2020). Sensors to Increase the Security of Underwater Communication Cables: A Review of Underwater Monitoring Sensors. Sensors, 20.","DOI":"10.3390\/s20030737"},{"key":"ref_112","doi-asserted-by":"crossref","first-page":"031302","DOI":"10.1063\/1.5026238","article-title":"Chip-scale atomic devices","volume":"5","author":"Kitching","year":"2018","journal-title":"Appl. Phys. Rev."},{"key":"ref_113","doi-asserted-by":"crossref","first-page":"2200153","DOI":"10.1002\/adpr.202200153","article-title":"On-Chip Light\u2013Atom Interactions: Physics and Applications","volume":"3","author":"Wang","year":"2022","journal-title":"Adv. Photonics Res."},{"key":"ref_114","doi-asserted-by":"crossref","unstructured":"Zhang, J.W., Meng, X., Han, T., Wei, X., Wang, L., Zhao, Y., Fu, G., Tian, N., Wang, Q., and Qin, S. (2023). Optical magnetic field sensors based on nanodielectrics: From biomedicine to IoT-based energy internet. IET Nanodielectrics.","DOI":"10.1049\/nde2.12049"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/11\/5318\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T19:47:39Z","timestamp":1760125659000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/11\/5318"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,3]]},"references-count":114,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2023,6]]}},"alternative-id":["s23115318"],"URL":"https:\/\/doi.org\/10.3390\/s23115318","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,6,3]]}}}