{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T15:05:00Z","timestamp":1788361500750,"version":"build-2803163510"},"reference-count":23,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2023,6,8]],"date-time":"2023-06-08T00:00:00Z","timestamp":1686182400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Deutsche Forschungsgemeinschaft","award":["442419336"],"award-info":[{"award-number":["442419336"]}]},{"name":"Deutsche Forschungsgemeinschaft","award":["WA 2913\/41-1"],"award-info":[{"award-number":["WA 2913\/41-1"]}]},{"name":"Deutsche Forschungsgemeinschaft","award":["MI 2608\/2-1"],"award-info":[{"award-number":["MI 2608\/2-1"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Biomechanical simulation allows for in silico estimations of biomechanical parameters such as muscle, joint and ligament forces. Experimental kinematic measurements are a prerequisite for musculoskeletal simulations using the inverse kinematics approach. Marker-based optical motion capture systems are frequently used to collect this motion data. As an alternative, IMU-based motion capture systems can be used. These systems allow flexible motion collection without nearly any restriction regarding the environment. However, one limitation with these systems is that there is no universal way to transfer IMU data from arbitrary full-body IMU measurement systems into musculoskeletal simulation software such as OpenSim. Thus, the objective of this study was to enable the transfer of collected motion data, stored as a BVH file, to OpenSim 4.4 to visualize and analyse the motion using musculoskeletal models. By using the concept of virtual markers, the motion saved in the BVH file is transferred to a musculoskeletal model. An experimental study with three participants was conducted to verify our method\u2019s performance. Results show that the present method is capable of (1) transferring body dimensions saved in the BVH file to a generic musculoskeletal model and (2) correctly transferring the motion data saved in the BVH file to a musculoskeletal model in OpenSim 4.4.<\/jats:p>","DOI":"10.3390\/s23125423","type":"journal-article","created":{"date-parts":[[2023,6,8]],"date-time":"2023-06-08T02:02:28Z","timestamp":1686189748000},"page":"5423","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":18,"title":["Method for Using IMU-Based Experimental Motion Data in BVH Format for Musculoskeletal Simulations via OpenSim"],"prefix":"10.3390","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5855-3765","authenticated-orcid":false,"given":"Iris","family":"Wechsler","sequence":"first","affiliation":[{"name":"Engineering Design, Department of Mechanical Engineering, Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg, 91058 Erlangen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Wolf","sequence":"additional","affiliation":[{"name":"Engineering Design, Department of Mechanical Engineering, Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg, 91058 Erlangen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sophie","family":"Fleischmann","sequence":"additional","affiliation":[{"name":"Engineering Design, Department of Mechanical Engineering, Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg, 91058 Erlangen, Germany"},{"name":"Machine Learning and Data Analytics Lab, Department Artificial Intelligence in Biomedical Engineering (AIBE), Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg, 91052 Erlangen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julian","family":"Waibel","sequence":"additional","affiliation":[{"name":"Engineering Design, Department of Mechanical Engineering, Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg, 91058 Erlangen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carla","family":"Molz","sequence":"additional","affiliation":[{"name":"Engineering Design, Department of Mechanical Engineering, Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg, 91058 Erlangen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9618-2942","authenticated-orcid":false,"given":"David","family":"Scherb","sequence":"additional","affiliation":[{"name":"Engineering Design, Department of Mechanical Engineering, Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg, 91058 Erlangen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3806-9922","authenticated-orcid":false,"given":"Julian","family":"Shanbhag","sequence":"additional","affiliation":[{"name":"Engineering Design, Department of Mechanical Engineering, Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg, 91058 Erlangen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Franz","sequence":"additional","affiliation":[{"name":"Engineering Design, Department of Mechanical Engineering, Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg, 91058 Erlangen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0244-5033","authenticated-orcid":false,"given":"Sandro","family":"Wartzack","sequence":"additional","affiliation":[{"name":"Engineering Design, Department of Mechanical Engineering, Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg, 91058 Erlangen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8610-1966","authenticated-orcid":false,"given":"J\u00f6rg","family":"Miehling","sequence":"additional","affiliation":[{"name":"Engineering Design, Department of Mechanical Engineering, Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg, 91058 Erlangen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,6,8]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1016\/j.knee.2015.02.019","article-title":"Kinematic alignment produces near-normal knee motion but increases contact stress after total knee arthroplasty: A case study on a single implant design","volume":"22","author":"Ishikawa","year":"2015","journal-title":"Knee"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1579","DOI":"10.1007\/s00402-017-2788-6","article-title":"Effect of changes of femoral offset on abductor and joint reaction forces in total hip arthroplasty","volume":"137","author":"Guillemin","year":"2017","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Ahram, T., and Taiar, R. (2022). Human Interaction, Emerging Technologies and Future Systems V, Springer International Publishing.","DOI":"10.1007\/978-3-030-85540-6"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1080\/10255842.2018.1522534","article-title":"An approach to generate noncontact ACL-injury prone situations on a computer using kinematic data of non-injury situations and Monte Carlo simulation","volume":"22","author":"Eberle","year":"2019","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1249\/JSR.0000000000000601","article-title":"Musculoskeletal Simulation Tools for Understanding Mechanisms of Lower-Limb Sports Injuries","volume":"18","author":"Bulat","year":"2019","journal-title":"Curr. Sport. Med. Rep."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1109\/TNSRE.2006.881565","article-title":"Kinematic design to improve ergonomics in human machine interaction","volume":"14","author":"Schiele","year":"2006","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1016\/j.robot.2016.12.012","article-title":"A human-centered design optimization approach for robotic exoskeletons through biomechanical simulation","volume":"91","author":"Zhou","year":"2017","journal-title":"Robot. Auton. Syst."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1017\/pds.2022.53","article-title":"A Musculoskeletal Human Model-Based Approach for Evaluating Support Concepts of Exoskeletons for Selected Use Cases","volume":"2","author":"Molz","year":"2022","journal-title":"Proc. Des. Soc."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1125","DOI":"10.1080\/02640414.2016.1211309","article-title":"Effect of ski boot rear stiffness (SBRS) on maximal ACL force during injury prone landing movements in alpine ski racing: A study with a musculoskeletal simulation model","volume":"35","author":"Eberle","year":"2017","journal-title":"J. Sport. Sci."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"869","DOI":"10.1080\/10255842.2019.1601179","article-title":"Optimal control simulation predicts effects of midsole materials on energy cost of running","volume":"22","author":"Dorschky","year":"2019","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1016\/j.ergon.2010.01.002","article-title":"Musculoskeletal computational analysis of the influence of car-seat design\/adjustments on long-distance driving fatigue","volume":"40","author":"Grujicic","year":"2010","journal-title":"Int. J. Ind. Ergon."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Kurpiers, N., Petrone, N., Supej, M., Wisser, A., Hansen, J., and Kersting, U.G. (2020). Application of Inertial Motion Unit-Based Kinematics to Assess the Effect of Boot Modifications on Ski Jump Landings\u2014A Methodological Study. Sensors, 20.","DOI":"10.3390\/s20133805"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1007\/BF02345966","article-title":"Measuring orientation of human body segments using miniature gyroscopes and accelerometers","volume":"43","author":"Luinge","year":"2005","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_14","unstructured":"Roetenberg, D., Luinge, H.J., and Slycke, P. (2023, April 13). Xsens MVN: Full 6DOF Human Motion Tracking Using Miniature Inertial Sensors. Available online: http:\/\/www.xsens.com."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"N63","DOI":"10.1088\/0967-3334\/34\/8\/N63","article-title":"Concurrent validation of Xsens MVN measurement of lower limb joint angular kinematics","volume":"34","author":"Zhang","year":"2013","journal-title":"Physiol. Meas."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1186\/s12984-022-01001-x","article-title":"OpenSense: An open-source toolbox for inertial-measurement-unit-based measurement of lower extremity kinematics over long durations","volume":"19","author":"Ibarra","year":"2022","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Stanev, D., Filip, K., Bitzas, D., Zouras, S., Giarmatzis, G., Tsaopoulos, D., and Moustakas, K. (2021). Real-Time Musculoskeletal Kinematics and Dynamics Analysis Using Marker- and IMU-Based Solutions in Rehabilitation. Sensors, 21.","DOI":"10.20944\/preprints202102.0202.v2"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"436","DOI":"10.1080\/10255842.2016.1240789","article-title":"Real-time inverse kinematics and inverse dynamics for lower limb applications using OpenSim","volume":"20","author":"Pizzolato","year":"2017","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.medengphy.2018.12.021","article-title":"Musculoskeletal model-based inverse dynamic analysis under ambulatory conditions using inertial motion capture","volume":"65","author":"Karatsidis","year":"2019","journal-title":"Med. Eng. Phys."},{"key":"ref_20","unstructured":"Noitom Ltd (2023, March 06). Perception Neuron Studio AXIS STUDIO: User Guide. Available online: https:\/\/support.neuronmocap.com\/hc\/en-us\/articles\/10037078429595-Axis-Neuron-User-Guide."},{"key":"ref_21","unstructured":"Noitom Ltd (2022). Axis Studio, Noitom Ltd."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1445","DOI":"10.1080\/10255842.2014.916698","article-title":"Benchmarking of dynamic simulation predictions in two software platforms using an upper limb musculoskeletal model","volume":"18","author":"Saul","year":"2015","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"ref_23","unstructured":"Chang, L.-R., Anand, P., and Varacallo, M. (2023). Anatomy, Shoulder and Upper Limb, Glenohumeral Joint, StatPearls Publishing LLC."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/12\/5423\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T19:50:32Z","timestamp":1760125832000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/12\/5423"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,8]]},"references-count":23,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2023,6]]}},"alternative-id":["s23125423"],"URL":"https:\/\/doi.org\/10.3390\/s23125423","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,6,8]]}}}