{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,16]],"date-time":"2026-11-16T23:11:25Z","timestamp":1794870685718,"version":"4.9.1"},"reference-count":53,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2023,6,10]],"date-time":"2023-06-10T00:00:00Z","timestamp":1686355200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003052","name":"Industrial Technology Innovation Program","doi-asserted-by":"publisher","award":["20008842"],"award-info":[{"award-number":["20008842"]}],"id":[{"id":"10.13039\/501100003052","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Ministry of Trade, Industry &amp; Energy (Republic of Korea)","award":["20008842"],"award-info":[{"award-number":["20008842"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The need for developing a simple and effective assessment tool for muscle mass has been increasing in a rapidly aging society. This study aimed to evaluate the feasibility of the surface electromyography (sEMG) parameters for estimating muscle mass. Overall, 212 healthy volunteers participated in this study. Maximal voluntary contraction (MVC) strength and root mean square (RMS) values of motor unit potentials from surface electrodes on each muscle (biceps brachii, triceps brachii, biceps femoris, rectus femoris) during isometric exercises of elbow flexion (EF), elbow extension (EE), knee flexion (KF), knee extension (KE) were acquired. New variables (MeanRMS, MaxRMS, and RatioRMS) were calculated from RMS values according to each exercise. Bioimpedance analysis (BIA) was performed to determine the segmental lean mass (SLM), segmental fat mass (SFM), and appendicular skeletal muscle mass (ASM). Muscle thicknesses were measured using ultrasonography (US). sEMG parameters showed positive correlations with MVC strength, SLM, ASM, and muscle thickness measured by US, but showed negative correlations with SFM. An equation was developed for ASM: ASM = \u221226.04 + 20.345 \u00d7 Height + 0.178 \u00d7 weight \u2212 2.065 \u00d7 (1, if female; 0, if male) + 0.327 \u00d7 RatioRMS(KF) + 0.965 \u00d7 MeanRMS(EE) (SEE = 1.167, adjusted R2 = 0.934). sEMG parameters in controlled conditions may represent overall muscle strength and muscle mass in healthy individuals.<\/jats:p>","DOI":"10.3390\/s23125490","type":"journal-article","created":{"date-parts":[[2023,6,12]],"date-time":"2023-06-12T02:28:42Z","timestamp":1686536922000},"page":"5490","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":21,"title":["Surface Electromyography-Driven Parameters for Representing Muscle Mass and Strength"],"prefix":"10.3390","volume":"23","author":[{"given":"Joo Hye","family":"Sung","sequence":"first","affiliation":[{"name":"Department of Neurology, Korea University Anam Hospital, Korea University College of Medicine, Seoul 02841, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seol-Hee","family":"Baek","sequence":"additional","affiliation":[{"name":"Department of Neurology, Korea University Anam Hospital, Korea University College of Medicine, Seoul 02841, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5548-3378","authenticated-orcid":false,"given":"Jin-Woo","family":"Park","sequence":"additional","affiliation":[{"name":"Department of Neurology, Korea University Anam Hospital, Korea University College of Medicine, Seoul 02841, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeong Hwa","family":"Rho","sequence":"additional","affiliation":[{"name":"Department of Neurology, Korea University Anam Hospital, Korea University College of Medicine, Seoul 02841, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0445-7185","authenticated-orcid":false,"given":"Byung-Jo","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Neurology, Korea University Anam Hospital, Korea University College of Medicine, Seoul 02841, Republic of Korea"},{"name":"BK21FOUR R&E Center for Learning Health Systems, Korea University, Seoul 02841, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,6,10]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"2636","DOI":"10.1016\/S0140-6736(19)31138-9","article-title":"Sarcopenia","volume":"393","author":"Sayer","year":"2019","journal-title":"Lancet"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1016\/j.jamda.2019.12.012","article-title":"Asian Working Group for Sarcopenia: 2019 Consensus Update on Sarcopenia Diagnosis and Treatment","volume":"21","author":"Chen","year":"2020","journal-title":"J. Am. Med. Dir. Assoc."},{"key":"ref_3","first-page":"258","article-title":"The Role of Ultrasound as a Diagnostic Tool for Sarcopenia","volume":"7","author":"Stringer","year":"2018","journal-title":"J Frailty Aging"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1123\/jab.13.2.135","article-title":"The use of surface electromyography in biomechanics","volume":"13","year":"1997","journal-title":"J. Appl. Biomech."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1186\/s12984-020-0645-2","article-title":"Age-specific differences in the time-frequency representation of surface electromyographic data recorded during a submaximal cyclic back extension exercise: A promising biomarker to detect early signs of sarcopenia","volume":"17","author":"Habenicht","year":"2020","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Leone, A., Rescio, G., Manni, A., Siciliano, P., and Caroppo, A. (2022). Comparative Analysis of Supervised Classifiers for the Evaluation of Sarcopenia Using a sEMG-Based Platform. Sensors, 22.","DOI":"10.3390\/s22072721"},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Park, J.W., Baek, S.H., Sung, J.H., and Kim, B.J. (2022). Predictors of Step Length from Surface Electromyography and Body Impedance Analysis Parameters. Sensors, 22.","DOI":"10.3390\/s22155686"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1186\/s12938-018-0567-4","article-title":"Human activity monitoring system based on wearable sEMG and accelerometer wireless sensor nodes","volume":"17","author":"Biagetti","year":"2018","journal-title":"Biomed. Eng. Online"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Baek, S.H., Sung, J.H., Park, J.W., Son, M.H., Lee, J.H., and Kim, B.J. (2023). Usefulness of muscle ultrasound in appendicular skeletal muscle mass estimation for sarcopenia assessment. PLoS ONE, 18.","DOI":"10.1371\/journal.pone.0280202"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"251","DOI":"10.3988\/jcn.2022.0219","article-title":"Relationships of Fall Risk With Frailty, Sarcopenia, and Balance Disturbances in Mild-to-Moderate Alzheimer\u2019s Disease","volume":"19","author":"Topuz","year":"2023","journal-title":"J. Clin. Neurol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"965827","DOI":"10.3389\/fphys.2022.965827","article-title":"Can phase angle from bioelectrical impedance analysis associate with neuromuscular properties of the knee extensors?","volume":"13","author":"Hirata","year":"2022","journal-title":"Front. Physiol."},{"key":"ref_12","first-page":"R271","article-title":"Extra- and intracellular water spaces in muscles of man at rest and with dynamic exercise","volume":"243","author":"Saltin","year":"1982","journal-title":"Am. J. Physiol."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1002\/jcsm.12159","article-title":"Bioelectrical impedance analysis for diagnosing sarcopenia and cachexia: What are we really estimating?","volume":"8","author":"Gonzalez","year":"2017","journal-title":"J. Cachexia Sarcopenia Muscle"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1016\/j.jocd.2018.10.008","article-title":"Reliability and Agreement of Various InBody Body Composition Analyzers as Compared to Dual-Energy X-Ray Absorptiometry in Healthy Men and Women","volume":"23","author":"McLester","year":"2020","journal-title":"J. Clin. Densitom."},{"key":"ref_15","unstructured":"SENIAM Management Group (2022, July 12). Recommendations for Sensor Locations on Individual Muscles. Available online: http:\/\/seniam.org\/sensor_location.htm."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1007\/s11357-015-9853-2","article-title":"Prediction and validation of DXA-derived appendicular lean soft tissue mass by ultrasound in older adults","volume":"37","author":"Abe","year":"2015","journal-title":"Age"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1016\/j.jelekin.2009.08.005","article-title":"Methodological aspects of SEMG recordings for force estimation--a tutorial and review","volume":"20","author":"Staudenmann","year":"2010","journal-title":"J. Electromyogr. Kinesiol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"985","DOI":"10.3389\/fphys.2017.00985","article-title":"Interpreting Signal Amplitudes in Surface Electromyography Studies in Sport and Rehabilitation Sciences","volume":"8","author":"Vigotsky","year":"2017","journal-title":"Front. Physiol."},{"key":"ref_19","first-page":"17","article-title":"Surface electromyography: Why, when and how to use it","volume":"4","author":"Vieira","year":"2011","journal-title":"Rev. Andal. Med. Deporte"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"869","DOI":"10.1007\/s00421-008-0972-7","article-title":"Anatomical predictors of maximum isometric and concentric knee extensor moment","volume":"105","author":"Blazevich","year":"2009","journal-title":"Eur. J. Appl. Physiol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1046\/j.1365-201x.2001.00867.x","article-title":"Muscle volume is a major determinant of joint torque in humans","volume":"172","author":"Fukunaga","year":"2001","journal-title":"Acta Physiol. Scand."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1046\/j.1365-201X.1996.483230000.x","article-title":"Human quadriceps cross-sectional area, torque and neural activation during 6 months strength training","volume":"157","author":"Narici","year":"1996","journal-title":"Acta Physiol. Scand."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Hayashida, I., Tanimoto, Y., Takahashi, Y., Kusabiraki, T., and Tamaki, J. (2014). Correlation between muscle strength and muscle mass, and their association with walking speed, in community-dwelling elderly Japanese individuals. PLoS ONE, 9.","DOI":"10.1371\/journal.pone.0111810"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1016\/0960-8966(94)00078-N","article-title":"Isometric strength and thickness relationships in human quadriceps muscle","volume":"5","author":"Freilich","year":"1995","journal-title":"Neuromuscul. Disord."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.clinbiomech.2009.10.001","article-title":"A comparison of ultrasound and electromyography measures of force and activation to examine the mechanics of abdominal wall contraction","volume":"25","author":"Brown","year":"2010","journal-title":"Clin. Biomech."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"614","DOI":"10.1016\/j.jelekin.2014.07.002","article-title":"Comparison between muscle activation measured by electromyography and muscle thickness measured using ultrasonography for effective muscle assessment","volume":"24","author":"Kim","year":"2014","journal-title":"J. Electromyogr. Kinesiol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1159","DOI":"10.1007\/s00421-016-3352-8","article-title":"Anatomical and neuromuscular variables strongly predict maximum knee extension torque in healthy men","volume":"116","author":"Trezise","year":"2016","journal-title":"Eur. J. Appl. Physiol."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1186\/1757-1146-7-11","article-title":"Electromyography and sonomyography analysis of the tibialis anterior: A cross sectional study","volume":"7","year":"2014","journal-title":"J. Foot Ankle Res."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"549","DOI":"10.3988\/jcn.2018.14.4.549","article-title":"Muscle Thickness and Echo Intensity of the Abdominal and Lower Extremity Muscles in Stroke Survivors","volume":"14","author":"Monjo","year":"2018","journal-title":"J. Clin. Neurol."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"308","DOI":"10.3988\/jcn.2022.18.3.308","article-title":"Changes in Muscle Thickness and Echo Intensity in Chronic Stroke Survivors: A 2-Year Longitudinal Study","volume":"18","author":"Monjo","year":"2022","journal-title":"J. Clin. Neurol."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"2658","DOI":"10.1016\/j.clinph.2018.09.013","article-title":"Indications for neuromuscular ultrasound: Expert opinion and review of the literature","volume":"129","author":"Walker","year":"2018","journal-title":"Clin. Neurophysiol."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1002\/mus.880140607","article-title":"Ultrasound imaging of the quadriceps muscle in elderly athletes and untrained men","volume":"14","author":"Suominen","year":"1991","journal-title":"Muscle Nerve"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1059","DOI":"10.1093\/gerona\/61.10.1059","article-title":"The loss of skeletal muscle strength, mass, and quality in older adults: The health, aging and body composition study","volume":"61","author":"Goodpaster","year":"2006","journal-title":"J. Gerontol. A Biol. Sci. Med. Sci."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"igx008","DOI":"10.1093\/geroni\/igx008","article-title":"Body Composition and Physical Function in Older Adults with Various Comorbidities","volume":"1","author":"Kim","year":"2017","journal-title":"Innov. Aging"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"2157","DOI":"10.1152\/jappl.2001.90.6.2157","article-title":"Attenuation of skeletal muscle and strength in the elderly: The Health ABC Study","volume":"90","author":"Goodpaster","year":"2001","journal-title":"J. Appl. Physiol. (1985)"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"1032","DOI":"10.1016\/j.medengphy.2010.07.004","article-title":"Continuous monitoring of electromyography (EMG), mechanomyography (MMG), sonomyography (SMG) and torque output during ramp and step isometric contractions","volume":"32","author":"Guo","year":"2010","journal-title":"Med. Eng. Phys."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"682","DOI":"10.1002\/mus.10375","article-title":"Measurement of muscle contraction with ultrasound imaging","volume":"27","author":"Hodges","year":"2003","journal-title":"Muscle Nerve"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"1191","DOI":"10.1109\/TBME.2007.909538","article-title":"Continuous monitoring of sonomyography, electromyography and torque generated by normal upper arm muscles during isometric contraction: Sonomyography assessment for arm muscles","volume":"55","author":"Shi","year":"2008","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.math.2006.06.011","article-title":"Measurement of lumbar multifidus muscle contraction with rehabilitative ultrasound imaging","volume":"12","author":"Kiesel","year":"2007","journal-title":"Man. Ther."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"1168","DOI":"10.1016\/j.medengphy.2008.02.009","article-title":"The effect of the subcutaneous fat on the transfer of current through skin and into muscle","volume":"30","author":"Petrofsky","year":"2008","journal-title":"Med. Eng. Phys."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"2558","DOI":"10.1111\/sms.13270","article-title":"Does normalization of voluntary EMG amplitude to M(MAX) account for the influence of electrode location and adiposity?","volume":"28","author":"Lanza","year":"2018","journal-title":"Scand. J. Med. Sci. Sports"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"614415","DOI":"10.3389\/fphys.2020.614415","article-title":"Intramuscular Fat Influences Neuromuscular Activation of the Gluteus Medius in Older Adults","volume":"11","author":"Lanza","year":"2020","journal-title":"Front. Physiol."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"103832","DOI":"10.1016\/j.medengphy.2022.103832","article-title":"Membrane capacitance and characteristic frequency are associated with contractile properties of skeletal muscle","volume":"106","author":"Yamada","year":"2022","journal-title":"Med. Eng. Phys."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1111\/ggi.13651","article-title":"Association of bioimpedance phase angle and prospective falls in older adults","volume":"19","author":"Uemura","year":"2019","journal-title":"Geriatr. Gerontol. Int."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1002\/jcsm.12860","article-title":"Phase angle from bioelectrical impedance analysis is a useful indicator of muscle quality","volume":"13","author":"Akamatsu","year":"2022","journal-title":"J. Cachexia Sarcopenia Muscle"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"111445","DOI":"10.1016\/j.nut.2021.111445","article-title":"Raw bioelectrical impedance analysis variables (phase angle and impedance ratio) are significant predictors of hand grip strength in adolescents and young adults","volume":"91\u201392","author":"Sacco","year":"2021","journal-title":"Nutrition"},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Giovannini, S., Brau, F., Forino, R., Berti, A., D\u2019Ignazio, F., Loreti, C., Bellieni, A., D\u2019Angelo, E., Di Caro, F., and Biscotti, L. (2021). Sarcopenia: Diagnosis and Management, State of the Art and Contribution of Ultrasound. J. Clin. Med., 10.","DOI":"10.3390\/jcm10235552"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/j.archger.2019.03.014","article-title":"Regional and total muscle mass, muscle strength and physical performance: The potential use of ultrasound imaging for sarcopenia","volume":"83","author":"Ata","year":"2019","journal-title":"Arch. Gerontol. Geriatr."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1515\/med-2017-0052","article-title":"Absolute Reliability and Concurrent Validity of Hand Held Dynamometry and Isokinetic Dynamometry in the Hip, Knee and Ankle Joint: Systematic Review and Meta-analysis","volume":"12","author":"Chamorro","year":"2017","journal-title":"Open Med."},{"key":"ref_50","doi-asserted-by":"crossref","unstructured":"Mentiplay, B.F., Perraton, L.G., Bower, K.J., Adair, B., Pua, Y.H., Williams, G.P., McGaw, R., and Clark, R.A. (2015). Assessment of Lower Limb Muscle Strength and Power Using Hand-Held and Fixed Dynamometry: A Reliability and Validity Study. PLoS ONE., 10.","DOI":"10.1371\/journal.pone.0140822"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1002\/jum.14343","article-title":"Prediction and Validation of DXA-Derived Appendicular Fat-Free Adipose Tissue by a Single Ultrasound Image of the Forearm in Japanese Older Adults","volume":"37","author":"Abe","year":"2018","journal-title":"J. Ultrasound Med."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1016\/j.ultrasmedbio.2014.09.007","article-title":"Validity of ultrasound prediction equations for total and regional muscularity in middle-aged and older men and women","volume":"41","author":"Abe","year":"2015","journal-title":"Ultrasound Med. Biol."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1007\/s12603-013-0419-7","article-title":"Applicability of ultrasound muscle thickness measurements for predicting fat-free mass in elderly population","volume":"18","author":"Takai","year":"2014","journal-title":"J. Nutr. Health Aging."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/12\/5490\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T19:52:22Z","timestamp":1760125942000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/12\/5490"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,10]]},"references-count":53,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2023,6]]}},"alternative-id":["s23125490"],"URL":"https:\/\/doi.org\/10.3390\/s23125490","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,6,10]]}}}