{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T14:47:59Z","timestamp":1783608479981,"version":"3.55.0"},"reference-count":42,"publisher":"MDPI AG","issue":"14","license":[{"start":{"date-parts":[[2023,7,16]],"date-time":"2023-07-16T00:00:00Z","timestamp":1689465600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Science, Technology &amp; Innovation Funding Authority (STIFA), Egypt","award":["31292"],"award-info":[{"award-number":["31292"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Mineral oil (MO) is the most popular insulating liquid that is used as an insulating and cooling medium in electrical power transformers. Indeed, for green energy and environmental protection requirements, many researchers introduced other oil types to study the various characteristics of alternative insulating oils using advanced diagnostic tools. In this regard, natural ester oil (NEO) can be considered an attractive substitute for MO. Although NEO has a high viscosity and high dielectric loss, it presents fire safety and environmental advantages over mineral oil. Therefore, the retrofilling of aged MO with fresh NEO is highly recommended for power transformers from an environmental viewpoint. In this study, two accelerated aging processes were applied to MO for 6 and 12 days to simulate MO in service for 6 and 12 years. Moreover, these aged oils were mixed with 80% and 90% fresh NEO. The dielectric strength, relative permittivity, and dissipation factor were sensed using a LCR meter and oil tester devices for all prepared samples to support the condition assessment performance of the oil mixtures. In addition, the electric field distribution was analyzed for a power transformer using the oil mixtures. Furthermore, the dynamic viscosity was measured for all insulating oil samples at different temperatures. From the obtained results, the sample obtained by mixing 90% natural ester oil with 10% mineral oil aged for 6 days is considered superior and achieves an improvement in dielectric strength and relative permittivity by approximately 43% and 48%, respectively, compared to fresh mineral oil. However, the dissipation factor was increased by approximately 20% but was at an acceptable limit. On the other hand, for the same oil sample, due to the higher molecular weight of the NEO, the viscosities of all mixtures were at a higher level than the mineral oil.<\/jats:p>","DOI":"10.3390\/s23146440","type":"journal-article","created":{"date-parts":[[2023,7,17]],"date-time":"2023-07-17T01:06:36Z","timestamp":1689555996000},"page":"6440","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":30,"title":["Condition Assessment of Natural Ester\u2013Mineral Oil Mixture Due to Transformer Retrofilling via Sensing Dielectric Properties"],"prefix":"10.3390","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1720-3616","authenticated-orcid":false,"given":"Hesham S.","family":"Karaman","sequence":"first","affiliation":[{"name":"Department of Electrical Engineering, Faculty of Engineering at Shoubra, Benha University, Cairo 11629, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3894-4299","authenticated-orcid":false,"given":"Diaa-Eldin A.","family":"Mansour","sequence":"additional","affiliation":[{"name":"Department of Electrical Power Engineering, Egypt-Japan University of Science and Technology (E-JUST), Alexandria 21934, Egypt"},{"name":"Department of Electrical Power and Machines Engineering, Faculty of Engineering, Tanta University, Tanta 31511, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9979-7333","authenticated-orcid":false,"given":"Matti","family":"Lehtonen","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering and Automation, School of Electrical Engineering, Aalto University, 02150 Espoo, Finland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9782-8813","authenticated-orcid":false,"given":"Mohamed M. F.","family":"Darwish","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Faculty of Engineering at Shoubra, Benha University, Cairo 11629, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,7,16]]},"reference":[{"key":"ref_1","first-page":"454","article-title":"Mixed Insulating Liquids with Mineral Oil for High-Voltage Transformer Applications: A Review","volume":"29","author":"Lyutikova","year":"2022","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"109361","DOI":"10.1016\/j.epsr.2023.109361","article-title":"Precise transformer fault diagnosis via random forest model enhanced by synthetic minority over-sampling technique","volume":"220","author":"Prasojo","year":"2023","journal-title":"Electr. Power Syst. Res."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1049\/iet-nde.2019.0038","article-title":"Review on natural ester and nanofluids as an environmental friendly alternative to transformer mineral oil","volume":"3","author":"Jacob","year":"2020","journal-title":"IET Nanodielectr."},{"key":"ref_4","first-page":"358","article-title":"Properties of new environmentally friendly biodegradable insulating fluids for power transformers","volume":"9","author":"Rozga","year":"2013","journal-title":"Eur. Sci. J."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Li, C., Zhang, X., Wang, X., Zhang, X., Liu, S., Yuan, T., Qu, W., and Zhang, Y. (2022). Distribution Characteristics and Potential Risks of Polycyclic Aromatic Hydrocarbon (PAH) Pollution at a Typical Industrial Legacy Site in Tianjin, North China. Land, 11.","DOI":"10.3390\/land11101806"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"2850","DOI":"10.1016\/j.matpr.2021.01.066","article-title":"Ester oil as an alternative to mineral transformer insulating liquid","volume":"43","author":"Srivastava","year":"2021","journal-title":"Mater. Today Proc."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Ward, S.A., El-Faraskoury, A., Badawi, M., Ibrahim, S.A., Mahmoud, K., Lehtonen, M., and Darwish, M.M.F. (2021). Towards Precise Interpretation of Oil Transformers via Novel Combined Techniques Based on DGA and Partial Discharge Sensors. Sensors, 21.","DOI":"10.3390\/s21062223"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"873","DOI":"10.1109\/TDEI.2015.005370","article-title":"A Review on Critical Evaluation of Natural Ester vis-\u00e0-vis Mineral Oil Insulating Liquid for Use in Transformers: Part 1","volume":"23","author":"Mehta","year":"2016","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"25954","DOI":"10.1109\/ACCESS.2022.3156102","article-title":"Reliable Estimation for Health Index of Transformer Oil Based on Novel Combined Predictive Maintenance Techniques","volume":"10","author":"Badawi","year":"2022","journal-title":"IEEE Access"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Darwish, M.M.F., Hassan, M.H.A., Abdel-Gawad, N.M.K., and Mansour, D.-E.A. (2022, January 13\u201315). A New Method for Estimating Transformer Health Index Based on Ultraviolet-Visible Spectroscopy. Proceedings of the 2022 IEEE 23rd International Middle East Power Systems Conference (MEPCON), Cairo, Egypt.","DOI":"10.1109\/MEPCON55441.2022.10021761"},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Alshehawy, A.M., Mansour, D.-E.A., Ghali, M., Lehtonen, M., and Darwish, M.M.F. (2021). Photoluminescence Spectroscopy Measurements for Effective Condition Assessment of Transformer Insulating Oil. Processes, 9.","DOI":"10.3390\/pr9050732"},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Darwish, M.M.F., Hassan, M.H.A., Abdel-Gawad, N.M.K., and Mansour, D.-E.A. (2022, January 13\u201318). Application of Infrared Spectroscopy for Discrimination Between Electrical and Thermal Faults in Transformer Oil. Proceedings of the 2022 9th International Conference on Condition Monitoring and Diagnosis (CMD), Kitakyushu, Japan.","DOI":"10.23919\/CMD54214.2022.9991616"},{"key":"ref_13","unstructured":"(2013). Fluids for Electrotechnical Applications\u2014Unused Natural Esters for Transformers and Similar Electrical Equipment, IEC 62770\u2014Edition 1.0 (Standard No. IEC 62770:2013)."},{"key":"ref_14","unstructured":"Redondo EI, D., P\u00e9rez, F.S., Cantero, M.\u00c1.V., Zurro, J.I., Cerde\u00f1o JA, R., and Nu\u00f1ez, J.N. (July, January 29). Soil ecotoxicity of natural ester transformer liquids. Proceedings of the IEEE 18th International Conference on Dielectric Liquids (ICDL), Bled, Slovenia."},{"key":"ref_15","first-page":"71","article-title":"Improvement of Power Transformers by using Mixtures of Mineral oil with Synthetic Esters","volume":"1","author":"Perrier","year":"2011","journal-title":"J. Colloid Interface Sci."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Nadolny, Z., Dombek, G., and Przybylek, P. (2016, January 16\u201319). Thermal Properties of a Mixture of Mineral Oil and Synthetic Ester in Terms of Its Application in the Transformer. Proceedings of the IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP), Toronto, ON, Canada.","DOI":"10.1109\/CEIDP.2016.7785457"},{"key":"ref_17","unstructured":"and Darma, I.S. (2008, January 7\u201311). Dielectric Properties of Mixtures between Mineral Oil and Natural Ester. Proceedings of the International Symposium on Electrical Insulating Materials, Yokkaichi, Japan."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"2384","DOI":"10.1049\/iet-gtd.2016.1970","article-title":"Stability of mineral oil and oil\u2013ester mixtures under thermal ageing and electrical discharges","volume":"11","author":"Hamdi","year":"2017","journal-title":"IET Gener. Transm. Distrib."},{"key":"ref_19","unstructured":"Toudja, T., Chetibi, F., Beldjilali, A., Moulai, H., and Beroual, A. (July, January 29). Electrical and physicochemical properties of mineral and vegetable oils mixtures. Proceedings of the IEEE International Conference on Liquid Dielectrics, Bled, Slovenia."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1846","DOI":"10.1109\/TDEI.2018.007223","article-title":"Fire Safety and Electrical Properties of Mixtures of Synthetic Ester\/Mineral Oil and Synthetic Ester\/Natural Ester","volume":"25","author":"Dombek","year":"2018","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1831","DOI":"10.1109\/TDEI.2018.007219","article-title":"Comparative Study of AC and DC Breakdown Voltages in Jatropha Methyl Ester Oil, Mineral Oil, and their Mixtures","volume":"25","author":"Beroual","year":"2018","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Ghoneim, S.S.M., Dessouky, S.S., Boubakeur, A., Elfaraskoury, A.A., Sharaf, A.B.A., Mahmoud, K., Lehtonen, M., and Darwish, M.M.F. (2021). Accurate Insulating Oil Breakdown Voltage Model Associated with Different Barrier Effects. Processes, 9.","DOI":"10.3390\/pr9040657"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1109\/TDEI.2022.3148447","article-title":"Thermal Analysis of Natural Cooling Type Distribution Transformer Retrofilled with Natural Ester Oil","volume":"29","author":"Dixit","year":"2022","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Beroual, A., Khaled, U., Noah, P.S.M., and Sitorus, H. (2017). Comparative Study of Breakdown Voltage of Mineral, Synthetic and Natural Oils and Based Mineral Oil Mixtures under AC and DC Voltages. Energies, 10.","DOI":"10.3390\/en10040511"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"108920","DOI":"10.1016\/j.epsr.2022.108920","article-title":"Analysis of AC breakdown strength of vegetable oils and effect of mineral oil","volume":"214","author":"Das","year":"2023","journal-title":"Electr. Power Syst. Res."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Alshehawy, A.M., Mansour, D.A., and Ghali, M. (2019, January 23\u201327). Optical Spectroscopy Analysis of Ester Oils under Thermal Aging Conditions. Proceedings of the IEEE International Conference on Dielectric Liquids (ICDL), Rome, Italy.","DOI":"10.1109\/ICDL.2019.8796836"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"3471","DOI":"10.1109\/TDEI.2017.006586","article-title":"Mitigating the impact of aging byproducts in transformer oil using TiO2 nanofillers","volume":"24","author":"Emara","year":"2017","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1115\/1.4010337","article-title":"A statistical distribution function of wide applicability","volume":"18","author":"Weibull","year":"1951","journal-title":"ASME J. Appl. Mech."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"968","DOI":"10.1049\/iet-smt.2018.5015","article-title":"Multiple nanoparticles for improvement of thermal and dielectric properties of oil nanofluids","volume":"13","author":"Mansour","year":"2019","journal-title":"IET Sci. Meas. Technol."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Mansour, D.A., Ahmed, H.M., and Salman, A.M. (2019, January 17\u201319). The Effect of Surface Modification of Titania Nanoparticles on the Dielectric Properties of Nanofluids. Proceedings of the International Middle East Power Systems Conference (MEPCON), Cairo, Egypt.","DOI":"10.1109\/MEPCON47431.2019.9007971"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1049\/hve2.12319","article-title":"Dissolved gas analysis and dissipation factor measurement of mineral oil-based nanofluids under thermal and electrical faults","volume":"8","author":"Maher","year":"2023","journal-title":"High Volt."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"107033","DOI":"10.1109\/ACCESS.2021.3098758","article-title":"The Effect of Interfacial Zone Due to Nanoparticle\u2013Surfactant Interaction on Dielectric Properties of Vegetable Oil Based Nanofluids","volume":"9","author":"Farade","year":"2021","journal-title":"IEEE Access"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1002\/masy.200850502","article-title":"Broadband Dielectric Relaxation Spectroscopy in Polymer Nanocomposites","volume":"265","author":"Pissis","year":"2008","journal-title":"Macromol. Symp."},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Gao, C., Ye, W., Xu, Q., Zhu, M., Zhu, W., and Hao, J. (2021, January 11\u201315). Influence of Replacing Oil with Different Natural Esters on the Thermal Ageing Behavior of Mineral Oil-Paper Insulation. Proceedings of the International Conference on Electrical Materials and Power Equipment (ICEMPE), Chongqing, China.","DOI":"10.1109\/ICEMPE51623.2021.9509245"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1626","DOI":"10.1109\/TDEI.2011.6032833","article-title":"A comparative study of physicochemical, dielectric and thermal properties of pressboard insulation impregnated with natural ester and mineral oil","volume":"18","author":"Liao","year":"2011","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1109\/TDEI.2019.007464","article-title":"Thermal and electrical properties of a novel 3-element mixed insulation oil for power transformers","volume":"26","author":"Liao","year":"2019","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1282","DOI":"10.1109\/TDEI.2021.009636","article-title":"Evaluation of the Properties of Mixtures of Aromatic Mineral Oil and Synthetic Ester for High-Voltage Equipment","volume":"28","author":"Lyutikova","year":"2021","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1049\/iet-smt.2018.5270","article-title":"Development of industrial scale PVC nanocomposites with comprehensive enhancement in dielectric properties","volume":"13","author":"Mansour","year":"2019","journal-title":"IET Sci. Meas. Technol."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"3490","DOI":"10.1109\/TDEI.2017.006692","article-title":"Enhancement of dielectric and mechanical properties of Polyvinyl Chloride nanocomposites using functionalized TiO2 nanoparticles","volume":"24","author":"Mansour","year":"2017","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_40","unstructured":"EGYTRAFO (2021, July 15). Oil Immersed Transformer Catalogue. Available online: https:\/\/egytrafo.com\/wp-content\/uploads\/2020\/06\/Oil-Transformers-Catalogue.pdf."},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"Bouhaddiche, R., Bouazabia, S., and Fofana, I. (2017, January 25\u201329). Thermal Modelling of Power Transformer. Proceedings of the IEEE Conference of Dielectric Liquid (ICDL), Manchester, UK.","DOI":"10.1109\/ICDL.2017.8124676"},{"key":"ref_42","unstructured":"(2021, July 15). COMSOL Multiphysics Reference Manual, \u00a9 1998\u20132019 COMSOL, Version: COMSOL 5.5. Available online: https:\/\/doc.comsol.com\/5.5\/doc\/com.comsol.help.comsol\/COMSOL_ReferenceManual.pdf."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/14\/6440\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T20:12:56Z","timestamp":1760127176000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/14\/6440"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7,16]]},"references-count":42,"journal-issue":{"issue":"14","published-online":{"date-parts":[[2023,7]]}},"alternative-id":["s23146440"],"URL":"https:\/\/doi.org\/10.3390\/s23146440","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,7,16]]}}}