{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T14:37:47Z","timestamp":1784212667679,"version":"3.55.0"},"reference-count":18,"publisher":"MDPI AG","issue":"16","license":[{"start":{"date-parts":[[2023,8,11]],"date-time":"2023-08-11T00:00:00Z","timestamp":1691712000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000006","name":"Office of Naval Research","doi-asserted-by":"publisher","award":["N00014-21-1-2212"],"award-info":[{"award-number":["N00014-21-1-2212"]}],"id":[{"id":"10.13039\/100000006","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Piezoelectric materials are defined by their ability to display a charge across their surface in response to mechanical strain, making them great for use in sensing applications. Such applications include pressure sensors, medical devices, energy harvesting and structural health monitoring (SHM). SHM describes the process of using a systematic approach to identify damage in engineering infrastructure. A method of SHM that uses piezoelectric wafers connected directly to the structure has become increasingly popular. An investigation of a novel pitch-catch method of determining instrumentation quality of piezoelectric wafer active sensors (PWASs) used in SHM was conducted as well as an investigation into the effects of defects in piezoelectric sensors and sensor bonding on the sensor response. This pitch-catch method was able to verify defect-less instrumentation quality of pristinely bonded PWASs. Additionally, the pitch-catch method was compared with the electromechanical impedance method in determining defects in piezoelectric sensor instrumentation. Using the pitch-catch method, it was found that defective instrumentation resulted in decreasing amplitude of received and transmitted signals as well as changes in the frequency spectrums of the signals, such as the elimination of high frequency peaks in those with defects in the bonding layer and an increased amplitude of around 600 kHz for a broken PWAS. The electromechanical impedance method concluded that bonding layer defects increase the primary frequency peak\u2019s amplitude and cause a downward frequency shift in both the primary and secondary frequency peaks in the impedance spectrum, while a broken sensor has the primary peak amplitude reduced while shifting upward and nearly eliminating the secondary peak.<\/jats:p>","DOI":"10.3390\/s23167103","type":"journal-article","created":{"date-parts":[[2023,8,11]],"date-time":"2023-08-11T12:10:23Z","timestamp":1691755823000},"page":"7103","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Piezoelectric Wafer Active Sensor Transducers for Acoustic Emission Applications"],"prefix":"10.3390","volume":"23","author":[{"given":"Connor","family":"Griffin","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, University of South Carolina, Columbia, SC 29208, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8948-677X","authenticated-orcid":false,"given":"Victor","family":"Giurgiutiu","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, University of South Carolina, Columbia, SC 29208, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,8,11]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"8718","DOI":"10.1021\/acs.chemmater.8b03296","article-title":"Applications of Piezoelectrics: Old and New","volume":"30","author":"Doglos","year":"2018","journal-title":"Chem. Mater."},{"key":"ref_2","first-page":"1851","article-title":"An Introduction to Structural Health Monitoring","volume":"365","author":"Farrar","year":"2007","journal-title":"R. Soc."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"012123","DOI":"10.1088\/1742-6596\/305\/1\/012123","article-title":"Structural Damage Detection with Piezoelectric Wafer Active Sensors","volume":"305","author":"Giurgiutiu","year":"2011","journal-title":"J. Phys. Conf. Ser."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Giurgiutiu, V. (2014). Structural Health Monitoring with Piezoelectric Wafer Active Sensors, Academic Press. [2nd ed.].","DOI":"10.1016\/B978-0-12-418691-0.00007-1"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1088\/1361-665X\/aa9bc2","article-title":"The signatures of acoustic emission waveforms from fatigue crack advancing in thin metallic plates","volume":"27","author":"Bhuiyan","year":"2018","journal-title":"Smart Mater. Struct."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Joseph, R., and Giurgiutiu, V. (2023). Non-crack-growth acoustic emission observed in controlled-stress-intensity-factor high-cycle-fatigue tests. Actuators, 12.","DOI":"10.3390\/act12030093"},{"key":"ref_7","unstructured":"Physical Acoustics Corp., MISTRAS Group (2023, January 01). Acoustic Emission Equipment and Software. Available online: https:\/\/www.physicalacoustics.com."},{"key":"ref_8","unstructured":"Innerspec Technologies (2023, January 01). Acoustic Emission Equipment and Software. Available online: https:\/\/www.innerspec.com\/portable\/aewin-software."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Mei, H., Haider, M.F., Joseph, R., Migot, A., and Giurgiutiu, V. (2019). Recent Advances in Piezoelectric Wafer Active Sensors for Structural Health Monitoring Applications. Sensors, 19.","DOI":"10.3390\/s19020383"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"3","DOI":"10.2514\/1.44776","article-title":"Durability and Survivability of Piezoelectric Wafer Active Sensors on Metallic Structure","volume":"48","author":"Lin","year":"2010","journal-title":"AIAA J."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Mueller, I., and Fritzen, C.P. (2017). Inspection of Piezoceramic Transducers Used for Structural Health Monitoring. Materials, 10.","DOI":"10.3390\/ma10010071"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"012114","DOI":"10.1088\/1742-6596\/628\/1\/012114","article-title":"Assessment of Piezoelectric Sensor Adhesive Bonding","volume":"628","author":"Wandowski","year":"2015","journal-title":"J. Phys. Conf. Ser."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1673","DOI":"10.1088\/0964-1726\/15\/6\/020","article-title":"Performance Assessment and Validation of Piezoelectric Active-Sensors in Structural Health Monitoring","volume":"15","author":"Park","year":"2006","journal-title":"Smart Mater. Struct."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"110411","DOI":"10.1016\/j.measurement.2021.110411","article-title":"Study of pre-damage diagnosis and analysis of adhesively bonded smart PZT sensors using EMI technique","volume":"188","author":"Saravanan","year":"2022","journal-title":"Measurement"},{"key":"ref_15","unstructured":"Mueller, I., Shpak, A., Golub, M.V., and Fritzen, C.P. (2016, January 5\u20138). Effects of Debonding of PWAS on the Wave Propagation and the Electro-Mechanical Impedance Spectrum. Proceedings of the 8th European Workshop on Structural Health Monitoring, Bilbao, Spain."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1007\/s10921-017-0392-x","article-title":"Detectability of Crack Length from Acoustic Emissions Using Physics of Wave Propagation in Plate Structures","volume":"36","author":"Poddar","year":"2017","journal-title":"J. Nondestruct. Eval."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Joseph, R., and Giurgiutiu, V. (2020). Analytical and experimental study of fatigue-crack-growth AE signals in thin sheet metals. Sensors, 20.","DOI":"10.3390\/s20205835"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Joseph, R., Mei, H., Migot, A., and Giurgiutiu, V. (2021). Crack-Length Estimation for Structural Health Monitoring Using the High-Frequency Resonances Excited by the Energy Release during Fatigue-Crack Growth. Sensors, 21.","DOI":"10.3390\/s21124221"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/16\/7103\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T20:31:11Z","timestamp":1760128271000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/16\/7103"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8,11]]},"references-count":18,"journal-issue":{"issue":"16","published-online":{"date-parts":[[2023,8]]}},"alternative-id":["s23167103"],"URL":"https:\/\/doi.org\/10.3390\/s23167103","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,8,11]]}}}