{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T02:29:10Z","timestamp":1760149750251,"version":"build-2065373602"},"reference-count":40,"publisher":"MDPI AG","issue":"18","license":[{"start":{"date-parts":[[2023,9,8]],"date-time":"2023-09-08T00:00:00Z","timestamp":1694131200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>In this paper, an inductive wireless link for motion recognition is investigated. In order to validate the feasibility of a wearable implementation, the use of three different materials is analyzed: a thin copper wire, a conductive yarn, and a conductive non-woven fabric. Results from the application of the developed devices on an arm are reported and discussed. It is demonstrated that the proposed textile inductive resonant wireless links are well suited for developing a compact wearable system for joint flexion recognition.<\/jats:p>","DOI":"10.3390\/s23187748","type":"journal-article","created":{"date-parts":[[2023,9,8]],"date-time":"2023-09-08T08:01:30Z","timestamp":1694160090000},"page":"7748","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Movement Recognition through Inductive Wireless Links: Investigation of Different Fabrication Techniques"],"prefix":"10.3390","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0595-2310","authenticated-orcid":false,"given":"Giuseppina","family":"Monti","sequence":"first","affiliation":[{"name":"Department of Engineering for Innovation, University of Salento, 73100 Lecce, Italy"},{"name":"CNIT\u2014National Inter-University Consortium for Telecommunications, 43124 Parma, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4154-1148","authenticated-orcid":false,"given":"Luciano","family":"Tarricone","sequence":"additional","affiliation":[{"name":"Department of Engineering for Innovation, University of Salento, 73100 Lecce, Italy"},{"name":"CNIT\u2014National Inter-University Consortium for Telecommunications, 43124 Parma, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2023,9,8]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1501004","DOI":"10.1109\/TASC.2023.3256342","article-title":"Improvement in Power Transmission Efficiency of Wireless Power Transfer System Using Superconducting Intermediate Coil","volume":"33","author":"Oshimoto","year":"2023","journal-title":"IEEE Trans. Appl. Supercond."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1073","DOI":"10.1109\/TIE.2023.3243273","article-title":"A Super-Resonant Frequency Control for Handshaking of an Inductive Power Transfer System with Adjacent Units","volume":"71","author":"Chen","year":"2023","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"5670","DOI":"10.1109\/TPEL.2023.3241107","article-title":"Simple Enhancement of Series\u2013Series-Compensated Inductive Wireless Power Transfer Links Operating with Load-Independent Voltage Output at Fixed Frequency to Attain Zero Inverter Phase Angle","volume":"38","author":"Kuperman","year":"2023","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1017\/wpt.2017.13","article-title":"Gain expressions for resonant inductive wireless power transfer links with one relay element","volume":"5","author":"Mastri","year":"2018","journal-title":"Wirel. Power Transf."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1809","DOI":"10.1109\/TMTT.2019.2963305","article-title":"Load-Independent Operative Regime for an Inductive Resonant WPT Link in Parallel Configuration","volume":"68","author":"Monti","year":"2020","journal-title":"IEEE Trans. Microw. Theory Tech."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"858","DOI":"10.1002\/2016RS006043","article-title":"Rigorous design of matched wireless power transfer links based on inductive coupling","volume":"51","author":"Monti","year":"2016","journal-title":"Radio Sci."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"3600705","DOI":"10.1109\/TASC.2023.3252490","article-title":"Investigation of HTS Coil Structure Robustness Against Misalignment Between Coils in a Wireless Power Transmission System for Railway Vehicles","volume":"33","author":"Inoue","year":"2023","journal-title":"IEEE Trans. Appl. Supercond."},{"key":"ref_8","first-page":"5400605","article-title":"Basic Study of a Wireless Power Transmission System Using Superconducting Coil as a Ground-Side Coil for Electric Vehicles","volume":"33","author":"Inoue","year":"2023","journal-title":"IEEE Trans. Appl. Supercond."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"2201","DOI":"10.1049\/iet-map.2017.0250","article-title":"Wireless resonant energy link for pulse generators implanted in the chest","volume":"11","author":"Monti","year":"2017","journal-title":"IET Microw. Antennas Propag."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"988","DOI":"10.1109\/TEMC.2020.3047465","article-title":"EMI in a Cardiac Implantable Electronic Device (CIED) by the Wireless Powering of a Left Ventricular Assist Device (LVAD)","volume":"63","author":"Campi","year":"2021","journal-title":"IEEE Trans. Electromagn. Compat."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"53","DOI":"10.2528\/PIERC12032606","article-title":"Experimental characterization of a 434 MHz wireless energy link for medical applications","volume":"30","author":"Monti","year":"2012","journal-title":"Prog. Electromagn. Res. C"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"2753","DOI":"10.1109\/TBME.2019.2895293","article-title":"Wrap-Around Wearable Coils for Seamless Monitoring of Joint Flexion","volume":"66","author":"Mishra","year":"2019","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1109\/TAP.2019.2935147","article-title":"Wearable Electrically Small Loop Antennas for Monitoring Joint Flexion and Rotation","volume":"68","author":"Mishra","year":"2020","journal-title":"IEEE Trans. Antennas Propag."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Brahim, N., Monti, G., and Tarricone, L. (2022, January 16\u201318). Wireless Resonant Energy Link for Joint Flexion Monitoring: Experimental Investigation by Using a NanoVNA. Proceedings of the 2022 IEEE MTT-S International Microwave Biomedical Conference (IMBioC), Suzhou, China.","DOI":"10.1109\/IMBioC52515.2022.9790147"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"5509","DOI":"10.1109\/TPEL.2016.2605698","article-title":"Misalignment Sensitivity of Strongly Coupled Wireless Power Transfer Systems","volume":"32","author":"Liu","year":"2017","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_16","first-page":"3023","article-title":"Wireless Power Transfer System with High Misalignment Tolerance for Bio-Medical Implants","volume":"67","author":"Wang","year":"2020","journal-title":"IEEE Trans. Circuits Syst. II Express Briefs"},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Monti, G., Mastri, F., Mongiardo, M., Corchia, L., and Tarricone, L. (2018, January 6\u201310). Transducer gain maximization for a resonant inductive WPT link using relay resonators. Proceedings of the 2018 IEEE MTT-S International Wireless Symposium (IWS), Chengdu, China.","DOI":"10.1109\/IEEE-IWS.2018.8400875"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Heinz, E.A., Kunze, K.S., Gruber, M., Bannach, D., and Lukowicz, P. (2006, January 22\u201324). Using Wearable Sensors for Real-Time Recognition Tasks in Games of Martial Arts\u2014An Initial Experiment. Proceedings of the 2006 IEEE Symposium on Computational Intelligence and Games, Reno, NV, USA.","DOI":"10.1109\/CIG.2006.311687"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1109\/JIOT.2016.2628938","article-title":"Enabling IoT for In-Home Rehabilitation: Accelerometer Signals Classification Methods for Activity and Movement Recognition","volume":"4","author":"Bisio","year":"2017","journal-title":"IEEE Internet Things J."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"e09633","DOI":"10.1016\/j.heliyon.2022.e09633","article-title":"An overview of Human Action Recognition in sports based on Computer Vision","volume":"8","author":"Host","year":"2022","journal-title":"Heliyon"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Abdallah, N.H., Brahim, R., Bouslimani, Y., Ghribi, M., and Kaddouri, A. (2021, January 27\u201328). IoT device for Athlete\u2019s movements recognition using inertial measurement unit (IMU). Proceedings of the 2021 IEEE International Conference on Industry 4.0, Artificial Intelligence, and Communications Technology (IAICT), Bandung, Indonesia.","DOI":"10.1109\/IAICT52856.2021.9532513"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Ma, R., Yan, D., Peng, H., Yang, T., Sha, X., Zhao, Y., and Liu, L. (2018, January 5\u20137). Basketball Movements Recognition Using a Wrist Wearable Inertial Measurement Unit. Proceedings of the 2018 IEEE 1st International Conference on Micro\/Nano Sensors for AI, Healthcare, and Robotics (NSENS), Shenzhen, China.","DOI":"10.1109\/NSENS.2018.8713634"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1673","DOI":"10.1109\/TBME.2022.3225065","article-title":"Assessment of a Multi-Sensor FBG-Based Wearable System in Sitting Postures Recognition and Respiratory Rate Evaluation of Office Workers","volume":"70","author":"Zaltieri","year":"2023","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"12173","DOI":"10.1109\/JSEN.2022.3175618","article-title":"Angle-Insensitive Human Motion and Posture Recognition Based on 4D Imaging Radar and Deep Learning Classifiers","volume":"22","author":"Zhao","year":"2022","journal-title":"IEEE Sens. J."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"2085","DOI":"10.1016\/j.jbiomech.2016.05.007","article-title":"Analysis of accuracy in optical motion capture\u2014A protocol for laboratory setup evaluation","volume":"49","author":"Eichelberger","year":"2016","journal-title":"J. Biomech."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1109\/TCSVT.2003.821980","article-title":"A vision-based approach to early detection of drowning incidents in swimming pools","volume":"14","author":"Lu","year":"2004","journal-title":"IEEE Trans. Circuits Syst. Video Technol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"2925","DOI":"10.1109\/TBME.2013.2266341","article-title":"Unobtrusive, continuous, in-home gait measurement using the Microsoft Kinect","volume":"60","author":"Stone","year":"2013","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1109\/JSEN.2010.2050309","article-title":"Diamond Sentry: Integrating Sensors and Cameras for Real-Time Monitoring of Indoor Spaces","volume":"11","author":"Turaga","year":"2011","journal-title":"IEEE Sens. J."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"12370","DOI":"10.1109\/JSEN.2023.3267300","article-title":"Robust Abnormal Human-Posture Recognition Using OpenPose and Multiview Cross-Information","volume":"23","author":"Xu","year":"2023","journal-title":"IEEE Sens. J."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Yasin, H., and Kr\u00fcger, B. (2021). An Efficient 3D Human Pose Retrieval and Reconstruction from 2D Image-Based Landmarks. Sensors, 21.","DOI":"10.3390\/s21072415"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"3379","DOI":"10.1109\/JSEN.2020.3023964","article-title":"Towards a Virtual Keyboard Scheme Based on Wearing One Motion Sensor Ring on Each Hand","volume":"21","author":"Lian","year":"2021","journal-title":"IEEE Sens. J."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"9383","DOI":"10.1109\/JIOT.2021.3055859","article-title":"MARS: Mixed Virtual and Real Wearable Sensors for Human Activity Recognition with Multidomain Deep Learning Model","volume":"8","author":"Pei","year":"2021","journal-title":"IEEE Internet Things J."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"706","DOI":"10.1109\/JSEN.2020.3012887","article-title":"Multisensor-Based 3D Gesture Recognition for a Decision-Making Training System","volume":"21","author":"Pan","year":"2021","journal-title":"IEEE Sens. J."},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Hong, F., You, S., Wei, M., Zhang, Y., and Guo, Z. (2016). MGRA: Motion Gesture Recognition via Accelerometer. Sensors, 16.","DOI":"10.3390\/s16040530"},{"key":"ref_35","unstructured":"Monti, G., Corchia, L., and Tarricone, L. (2013, January 9\u201311). Fabrication techniques for wearable antennas. Proceedings of the 2013 European Microwave Conference, Nuremberg, Germany."},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Corchia, L., Monti, G., and Tarricone, L. (2019). A Frequency Signature RFID Chipless Tag for Wearable Applications. Sensors, 19.","DOI":"10.3390\/s19030494"},{"key":"ref_37","unstructured":"(2023, July 26). Shieldex\u00ae 235\/36 HCB. Available online: https:\/\/www.shieldex.de\/en\/products\/shieldex-235-36-hcb-2\/."},{"key":"ref_38","unstructured":"(2023, July 26). Shieldex\u00ae Kiel-SK-96. Available online: https:\/\/www.shieldex.de\/en\/products\/shieldex-kiel-sk-96\/."},{"key":"ref_39","unstructured":"(2023, July 26). AWR Design Environment Platform. Available online: https:\/\/www.cadence.com\/en_US\/home\/tools\/system-analysis\/rf-microwave-design\/awr-design-environment-platform.html."},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Wang, Q., Che, W., Monti, G., and Mongiardo, M. (September, January 28). Measurements for Wireless Power Transfer by Using NanoVNA. Proceedings of the 2021 XXXIVth General Assembly and Scientific Symposium of the International Union of Radio Science (URSI GASS), Rome, Italy.","DOI":"10.23919\/URSIGASS51995.2021.9560402"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/18\/7748\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T20:47:15Z","timestamp":1760129235000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/18\/7748"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,8]]},"references-count":40,"journal-issue":{"issue":"18","published-online":{"date-parts":[[2023,9]]}},"alternative-id":["s23187748"],"URL":"https:\/\/doi.org\/10.3390\/s23187748","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2023,9,8]]}}}