{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,16]],"date-time":"2026-01-16T01:13:10Z","timestamp":1768525990135,"version":"3.49.0"},"reference-count":66,"publisher":"MDPI AG","issue":"19","license":[{"start":{"date-parts":[[2023,9,26]],"date-time":"2023-09-26T00:00:00Z","timestamp":1695686400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Imec AAA-ingestibles project","award":["01N11619"],"award-info":[{"award-number":["01N11619"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This study investigates wireless power transfer for deep in-body receivers, determining the optimal frequency, power budget, and design for the transmitter and receiver. In particular, the focus is on small, in-body receivers at large depths up to 20 cm for obese patients. This enables long-term monitoring of the gastrointestinal tract for all body types. Numerical simulations are used to investigate power transfer and losses as a function of frequency and to find the optimal design at the selected frequency for an obese body model. From all ISM-frequencies in the investigated range (1 kHz\u201310 GHz), the value of 13.56 MHz yields the best performance. This optimum corresponds to the transition from dominant copper losses in conductors to dominant losses in conductive tissue. At this frequency, a transmitting and receiving coil are designed consisting of 12 and 23 windings, respectively. With a power transfer efficiency of 2.70\u00d710\u22125, 18 \u00b5W can be received for an input power of 0.68 W while still satisfying exposure guidelines. The power transfer is validated by measurements. For the first time, efficiency values and the power budget are reported for WPT through 20 cm of tissue to mm sized receivers. Compared to WPT at higher frequencies, as commonly used for small receivers, the proposed system is more suitable for WPT to large depths in-body and comes with the advantage that no focusing is required, which can accommodate multiple receivers and uncertainty about receiver location more easily. The received power allows long-term sensing in the gastrointestinal tract by, e.g., temperature, pressure, and pH sensors, motility sensing, or even gastric stimulation.<\/jats:p>","DOI":"10.3390\/s23198084","type":"journal-article","created":{"date-parts":[[2023,9,26]],"date-time":"2023-09-26T03:45:23Z","timestamp":1695699923000},"page":"8084","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Optimal Frequency and Wireless Power Budget for Miniature Receivers in Obese People"],"prefix":"10.3390","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3636-8144","authenticated-orcid":false,"given":"Tom","family":"Van de Steene","sequence":"first","affiliation":[{"name":"Department of Information Technology, Ghent University\/imec, B-9052 Ghent, Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Emmeric","family":"Tanghe","sequence":"additional","affiliation":[{"name":"Department of Information Technology, Ghent University\/imec, B-9052 Ghent, Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luc","family":"Martens","sequence":"additional","affiliation":[{"name":"Department of Information Technology, Ghent University\/imec, B-9052 Ghent, Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carmine","family":"Garripoli","sequence":"additional","affiliation":[{"name":"Holst Centre\/imec, 5656 AE Eindhoven, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stefano","family":"Stanzione","sequence":"additional","affiliation":[{"name":"Holst Centre\/imec, 5656 AE Eindhoven, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8807-0673","authenticated-orcid":false,"given":"Wout","family":"Joseph","sequence":"additional","affiliation":[{"name":"Department of Information Technology, Ghent University\/imec, B-9052 Ghent, Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2023,9,26]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1089\/lap.1997.7.369","article-title":"A Brief History of Endoscopy, Laparoscopy, and Laparoscopic Surgery","volume":"7","author":"Spaner","year":"2009","journal-title":"J. Laparoendosc. Adv. Surg. Tech."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1038\/173039b0","article-title":"A flexible fibrescope, using static scanning","volume":"173","author":"Hopkins","year":"1954","journal-title":"Nature"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1038\/35013140","article-title":"Wireless capsule endoscopy","volume":"405","author":"Iddan","year":"2000","journal-title":"Nature"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"E396","DOI":"10.1055\/a-1073-7653","article-title":"Defining gastrointestinal transit time using video capsule endoscopy: A study of healthy subjects","volume":"8","author":"Murphy","year":"2020","journal-title":"Endosc. Int. Open"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"2167","DOI":"10.1007\/s10620-009-0899-9","article-title":"Wireless capsule motility: Comparison of the smartPill\u00ae GI monitoring system with scintigraphy for measuring whole gut transit","volume":"54","author":"Maqbool","year":"2009","journal-title":"Dig. Dis. Sci."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1109\/JMEMS.2020.3006580","article-title":"Miniaturized Electronic Circuit Design Challenges for Ingestible Devices","volume":"29","author":"Even","year":"2020","journal-title":"J. Microelectromech. Syst."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Mau, M.M., Sarker, S., and Terry, B.S. (2021). Ingestible devices for long-term gastrointestinal residency: A review. Prog. Biomed. Eng., 3.","DOI":"10.1088\/2516-1091\/ac1731"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"2010918","DOI":"10.1002\/adfm.202010918","article-title":"Magnetic Living Hydrogels for Intestinal Localization, Retention, and Diagnosis","volume":"31","author":"Liu","year":"2021","journal-title":"Adv. Funct. Mater."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1097\/00003081-195903000-00016","article-title":"Basal body temperature determinations in the management of menstrual disorders","volume":"2","author":"Palmer","year":"1959","journal-title":"Clin. Obstet. Gynecol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"5","DOI":"10.5334\/jcr.200","article-title":"Using Circadian Rhythm Patterns of Continuous Core Body Temperature to Improve Fertility and Pregnancy Planning","volume":"18","author":"Webster","year":"2020","journal-title":"J. Circadian Rhythm."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1586\/17474124.2014.922869","article-title":"The use of SmartPill for gastric monitoring","volume":"8","author":"Hasler","year":"2014","journal-title":"Expert Rev. Gastroenterol. Hepatol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.jinf.2019.11.003","article-title":"Ingestible sensors correlate closely with peripheral temperature measurements in febrile patients","volume":"80","author":"Huang","year":"2020","journal-title":"J. Infect."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1111\/j.1365-2036.2006.03039.x","article-title":"Review article: Complete gastro-oesophageal reflux monitoring \u2013 combined pH and impedance","volume":"24","author":"Tutuian","year":"2006","journal-title":"Aliment Pharmacol Ther"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Liao, C.H., Cheng, C.T., Chen, C.C., Jow, U.M., Chen, C.H., Lai, Y.L., Chen, Y.C., and Ho, D.R. (2020). An Ingestible Electronics for Continuous and Real-Time Intraabdominal Pressure Monitoring. J. Pers. Med., 11.","DOI":"10.3390\/jpm11010012"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"915","DOI":"10.1126\/science.aas9315","article-title":"An ingestible bacterial-electronic system to monitor gastrointestinal health","volume":"360","author":"Mimee","year":"2018","journal-title":"Science"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1900053","DOI":"10.1002\/aisy.201900053","article-title":"Ingestible Osmotic Pill for In Vivo Sampling of Gut Microbiomes","volume":"1","author":"Oliveira","year":"2019","journal-title":"Adv. Intell. Syst."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Baltsavias, S., Van Treuren, W., Weber, M.J., Charthad, J., Baker, S., Sonnenburg, J.L., and Arbabian, A. (2020). In Vivo Wireless Sensors for Gut Microbiome Redox Monitoring. IEEE Trans. Biomed. Eng., 67.","DOI":"10.1109\/TBME.2019.2948575"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"7405","DOI":"10.1038\/s41467-022-35074-y","article-title":"A self-powered ingestible wireless biosensing system for real-time in situ monitoring of gastrointestinal tract metabolites","volume":"13","author":"Maganti","year":"2022","journal-title":"Nat. Commun."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1146","DOI":"10.1073\/pnas.1806392115","article-title":"Chronic and acute stress monitoring by electrophysiological signals from adrenal gland","volume":"116","author":"Sunwoo","year":"2019","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Lo, Y.K., Wang, P.M., Dubrovsky, G., Wu, M.D., Chan, M., Dunn, J.C., and Liu, W. (2018). A Wireless Implant for Gastrointestinal Motility Disorders. Micromachines, 9.","DOI":"10.3390\/mi9010017"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"S12","DOI":"10.1007\/BF03342141","article-title":"Gastric pacing as therapy for morbid obesity: Preliminary results","volume":"12","author":"Cigaina","year":"2002","journal-title":"Obes. Surg."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Xie, W., Kothari, V., and Terry, B.S. (2015). A bio-inspired attachment mechanism for long-term adhesion to the small intestine. Biomed. Microdevices, 17.","DOI":"10.1007\/s10544-015-9972-7"},{"key":"ref_23","unstructured":"(2023, September 11). AUTOCAPSULE\u2014Autonomous Multimodal Implantable Endoscopic Capsule for the Gastrointestinal Tract. Available online: https:\/\/www.autocapsule.eu\/."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"4133","DOI":"10.1126\/sciadv.abb4133","article-title":"Gastrointestinal-resident, shape-changing microdevices extend drug release in vivo","volume":"6","author":"Ghosh","year":"2020","journal-title":"Sci. Adv."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Khan, S.R., Pavuluri, S.K., Cummins, G., and Desmulliez, M.P. (2020). Wireless Power Transfer Techniques for Implantable Medical Devices: A Review. Sensors, 20.","DOI":"10.3390\/s20123487"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"5093","DOI":"10.3748\/wjg.v28.i35.5093","article-title":"Robotic, self-propelled, self-steerable, and disposable colonoscopes: Reality or pipe dream? A state of the art review","volume":"28","author":"Winters","year":"2022","journal-title":"World J. Gastroenterol."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Rao, K.M.P., Alotaibi, F.M., Alkanfery, H.M., Mehedi, I.M., Rao, K.P., Alotaibi, F.M., and Alkanfery, H.M. (2023). Intelligent Wireless Capsule Endoscopy for the Diagnosis of Gastrointestinal Diseases. Diagnostics, 13.","DOI":"10.3390\/diagnostics13081445"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"102368","DOI":"10.1109\/ACCESS.2021.3098333","article-title":"Development of Ingestible Thermometer with Built-in Coil Antenna Charged by Gastric Acid Battery and Demonstration of Long-Time in Vivo Telemetry","volume":"9","author":"Yoshida","year":"2021","journal-title":"IEEE Access"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"2100199","DOI":"10.1002\/adhm.202100199","article-title":"Recent Advances of Energy Solutions for Implantable Bioelectronics","volume":"10","author":"Sheng","year":"2021","journal-title":"Adv. Healthc. Mater."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"2100614","DOI":"10.1002\/adhm.202100614","article-title":"Wireless Power Transfer and Telemetry for Implantable Bioelectronics","volume":"10","author":"Yoo","year":"2021","journal-title":"Adv. Healthc. Mater."},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Nadeau, P., El-Damak, D., Glettig, D., Kong, Y.L., Mo, S., Cleveland, C., Booth, L., Roxhed, N., Langer, R., and Chandrakasan, A.P. (2017). Prolonged energy harvesting for ingestible devices. Nat. Biomed. Eng., 1.","DOI":"10.1038\/s41551-016-0022"},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Dinis, H., and Mendes, P.M. (2021). A comprehensive review of powering methods used in state-of-the-art miniaturized implantable electronic devices. Biosens. Bioelectron., 172.","DOI":"10.1016\/j.bios.2020.112781"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1118\/1.3668316","article-title":"Attenuation, scattering, and absorption of ultrasound in the skull bone","volume":"39","author":"Pinton","year":"2012","journal-title":"Med. Phys."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1109\/RBME.2017.2683520","article-title":"Wireless Power Transfer Strategies for Implantable Bioelectronics","volume":"10","author":"Agarwal","year":"2017","journal-title":"IEEE Rev. Biomed. Eng."},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Lecluyse, C., Minnaert, B., and Kleemann, M. (2021). A Review of the Current State of Technology of Capacitive Wireless Power Transfer. Energies, 14.","DOI":"10.3390\/en14185862"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"7974","DOI":"10.1073\/pnas.1403002111","article-title":"Wireless power transfer to deep-tissue microimplants","volume":"111","author":"Ho","year":"2014","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Huang, Y., Yang, P., and Zhang, Z. (2021, January 26\u201329). An ECG Acquisition System with Piezoelectric Energy Harvesting for Low Power Healthcare Devices. Proceedings of the International Conference on ASIC, Kunming, China.","DOI":"10.1109\/ASICON52560.2021.9620495"},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Banks, E., Lim, L., Seubsman, S.A., Bain, C., and Sleigh, A. (2011). Relationship of obesity to physical activity, domestic activities, and sedentary behaviours: Cross-sectional findings from a national cohort of over 70,000 Thai adults. BMC Public Health, 11.","DOI":"10.1186\/1471-2458-11-762"},{"key":"ref_39","first-page":"28","article-title":"Correlation between Body Mass Index and abdominal circumference in Belgian adults: A cross-sectional study","volume":"55","author":"Wilmet","year":"2017","journal-title":"Rom. J. Intern. Med."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"2680","DOI":"10.1109\/TMTT.2022.3231492","article-title":"Wireless Powering Efficiency of Deep-Body Implantable Devices","volume":"71","author":"Soares","year":"2023","journal-title":"IEEE Trans. Microw. Theory Tech."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"3438","DOI":"10.1109\/TMTT.2021.3065560","article-title":"Biotelemetry and Wireless Powering of Biomedical Implants Using a Rectifier Integrated Self-Diplexing Implantable Antenna","volume":"69","author":"Iqbal","year":"2021","journal-title":"IEEE Trans. Microw. Theory Tech."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"1339","DOI":"10.1049\/pel2.12473","article-title":"Powering implanted sensors that monitor human activity using spider-web coil wireless power transfer","volume":"16","author":"Mahmood","year":"2023","journal-title":"IET Power Electron."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"818","DOI":"10.1109\/JSSC.2021.3129993","article-title":"Magnetoelectric Bio-Implants Powered and Programmed by a Single Transmitter for Coordinated Multisite Stimulation","volume":"57","author":"Yu","year":"2022","journal-title":"IEEE J. Solid-State Circuits"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"2100664","DOI":"10.1002\/adhm.202100664","article-title":"Wireless Power Delivery Techniques for Miniature Implantable Bioelectronics","volume":"10","author":"Singer","year":"2021","journal-title":"Adv. Healthc. Mater."},{"key":"ref_45","doi-asserted-by":"crossref","unstructured":"Murliky, L., Oliveira, G., de Sousa, F.R., and Brusamarello, V.J. (2022). Tracking and Dynamic Tuning of a Wireless Powered Endoscopic Capsule. Sensors, 22.","DOI":"10.3390\/s22186924"},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"Campi, T., Cruciani, S., De Santis, V., Maradei, F., and Feliziani, M. (2019). Near field wireless powering of deep medical implants. Energies, 12.","DOI":"10.3390\/en12142720"},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Khan, S.R., and Desmulliez, M.P. (2019). Towards a Miniaturized 3D Receiver WPT System for Capsule Endoscopy. Micromachines, 10.","DOI":"10.3390\/mi10080545"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"13689","DOI":"10.1038\/s41598-022-18000-6","article-title":"Wireless power transfer system for deep-implanted biomedical devices","volume":"12","author":"Iqbal","year":"2022","journal-title":"Sci. Rep."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"1739","DOI":"10.1109\/TAP.2010.2044310","article-title":"Optimal frequency for wireless power transmission into dispersive tissue","volume":"58","author":"Poon","year":"2010","journal-title":"IEEE Trans. Antennas Propag."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"4838","DOI":"10.1109\/TAP.2012.2207341","article-title":"Wireless power transfer to miniature implants: Transmitter optimization","volume":"60","author":"Kim","year":"2012","journal-title":"IEEE Trans. Antennas Propag."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"4073","DOI":"10.1109\/TAP.2019.2905672","article-title":"Optimal Frequency for Wireless Power Transmission into the Body: Efficiency Versus Received Power","volume":"67","author":"Freeman","year":"2019","journal-title":"IEEE Trans. Antennas Propag."},{"key":"ref_52","doi-asserted-by":"crossref","unstructured":"Soares, I.V., Gao, M., Skrivervik, A.K., Sipus, Z., Zhadobov, M., Sauleau, R., and Nikolayev, D. (2021, January 1\u20134). Physical bounds on implant powering efficiency using body-conformal WPT systems. Proceedings of the 2021 IEEE Wireless Power Transfer Conference, WPTC, San Diego, CA, USA.","DOI":"10.1109\/WPTC51349.2021.9458026"},{"key":"ref_53","doi-asserted-by":"crossref","unstructured":"Gosselin, M.C., Neufeld, E., Moser, H., Huber, E., Farcito, S., Gerber, L., Jedensjo, M., Hilber, I., Gennaro, F.D., and Lloyd, B. (2014). Development of a new generation of high-resolution anatomical models for medical device evaluation: The Virtual Population 3.0. Phys. Med. Biol., 59.","DOI":"10.1088\/0031-9155\/59\/18\/5287"},{"key":"ref_54","unstructured":"(2023, September 13). COMSOL Multiphysics v5.6. COMSOL AB, Stockholm, Sweden. Available online: https:\/\/www.comsol.com."},{"key":"ref_55","doi-asserted-by":"crossref","unstructured":"Gabriel, C. (1996). Compilation of the Dielectric Properties of Body Tissues at RF and Microwave Frequencies, Defense Technical Information Center. Technical Report.","DOI":"10.21236\/ADA303903"},{"key":"ref_56","doi-asserted-by":"crossref","unstructured":"Jayathurathnage, P., Vilathgamuwa, M., and Simovski, C. (2018, January 10\u201313). Revisiting Two-Port Network Analysis for Wireless Power Transfer (WPT) Systems. Proceedings of the 2018 IEEE 4th Southern Power Electronics Conference, SPEC 2018, Singapore.","DOI":"10.1109\/SPEC.2018.8635846"},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"4326","DOI":"10.1109\/20.334076","article-title":"Modelling the Effects of Eddy Current Losses on Frequency Dependent Hysteresis in Electrically Conducting Media","volume":"30","author":"Jiles","year":"1994","journal-title":"IEEE Trans. Magn."},{"key":"ref_58","unstructured":"(2002). Standard Specification for Standard Nominal Diameters and Cross Sectional Areas of AWG Sizes of Solid Round Wires Used as Electrical Conductors (Standard No. ASTM Standard No. B258-02)."},{"key":"ref_59","doi-asserted-by":"crossref","unstructured":"International Commission on Non-Ionizing Radiation Protection (2010). Guidelines for limiting exposure to time-varying electric and magnetic fields (1 Hz\u2013100 kHz). Health Phys., 99, 818\u2013836.","DOI":"10.1097\/HP.0b013e3181f06c86"},{"key":"ref_60","unstructured":"IEEE (2019). C95.1-2019\u2014IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 Hz to 300 GHz, IEEE."},{"key":"ref_61","unstructured":"Zurich MedTech (2018). Sim4Life v6.2, Zurich MedTech."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"2067","DOI":"10.1038\/s41598-020-59017-z","article-title":"Synchronized Biventricular Heart Pacing in a Closed-chest Porcine Model based on Wirelessly Powered Leadless Pacemakers","volume":"10","author":"Lyu","year":"2020","journal-title":"Sci. Rep."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"1900311","DOI":"10.1109\/JTEHM.2019.2910102","article-title":"A Miniaturized UHF-Band Rectenna for Power Transmission to Deep-Body Implantable Devices","volume":"7","author":"Abdi","year":"2019","journal-title":"IEEE J. Transl. Eng. Health Med."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"195551","DOI":"10.1109\/ACCESS.2020.3032848","article-title":"Implantable wireless transmission rectenna system for biomedical wireless applications","volume":"8","author":"Ding","year":"2020","journal-title":"IEEE Access"},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"1280","DOI":"10.1038\/nbt.3415","article-title":"Soft, stretchable, fully implantable miniaturized optoelectronic systems for wireless optogenetics","volume":"33","author":"Park","year":"2015","journal-title":"Nat. Biotechnol."},{"key":"ref_66","doi-asserted-by":"crossref","unstructured":"Danneels, H., Coddens, K., and Gielen, G. (2011, January 12\u201316). A fully-digital, 0.3V, 270 nW capacitive sensor interface without external references. Proceedings of the European Solid-State Circuits Conference, Helsinki, Finland.","DOI":"10.1109\/ESSCIRC.2011.6044963"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/19\/8084\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T20:58:21Z","timestamp":1760129901000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/19\/8084"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,26]]},"references-count":66,"journal-issue":{"issue":"19","published-online":{"date-parts":[[2023,10]]}},"alternative-id":["s23198084"],"URL":"https:\/\/doi.org\/10.3390\/s23198084","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9,26]]}}}