{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,11]],"date-time":"2026-01-11T01:27:44Z","timestamp":1768094864934,"version":"3.49.0"},"reference-count":30,"publisher":"MDPI AG","issue":"19","license":[{"start":{"date-parts":[[2023,10,6]],"date-time":"2023-10-06T00:00:00Z","timestamp":1696550400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Due to the characteristics of peroxide explosives, which are difficult to detect via conventional detection methods and have high explosive power, a fluorescent photoelectric detection system based on fluorescence detection technology was designed in this study to achieve the high-sensitivity detection of trace peroxide explosives in practical applications. Through actual measurement experiments and numerical simulation methods, the derivative dynamic time warping (DDTW) algorithm and the Spearman correlation coefficient were used to calculate the DDTW\u2013Spearman distance to achieve time series correlation measurements. The detection sensitivity of triacetone triperoxide (TATP) and H2O2 was studied, and the detection of organic substances of acetone, acetylene, ethanol, ethyl acetate, and petroleum ether was carried out. The stability and specific detection ability of the fluorescent photoelectric detection system were determined. The research results showed that the fluorescence photoelectric detection system can effectively identify the detection data of TATP, H2O2, acetone, acetonitrile, ethanol, ethyl acetate, and petroleum ether. The detection limit of 0.01 mg\/mL of TATP and 0.0046 mg\/mL of H2O2 was less than 10 ppb. The time series similarity measurement method improves the analytical capabilities of fluorescence photoelectric detection technology.<\/jats:p>","DOI":"10.3390\/s23198264","type":"journal-article","created":{"date-parts":[[2023,10,6]],"date-time":"2023-10-06T08:29:12Z","timestamp":1696580952000},"page":"8264","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Fluorescent Photoelectric Detection of Peroxide Explosives Based on a Time Series Similarity Measurement Method"],"prefix":"10.3390","volume":"23","author":[{"given":"Weize","family":"Shi","sequence":"first","affiliation":[{"name":"School of Mechatronical Engineering, Beijing Institute of Technology, Beijing 100081, China"}]},{"given":"Yabin","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Mechatronical Engineering, Beijing Institute of Technology, Beijing 100081, China"}]}],"member":"1968","published-online":{"date-parts":[[2023,10,6]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1007\/s00340-006-2372-1","article-title":"Pulsed Laser Surface Fragmentation and Mid-Infrared Laser Spectroscopy for Remote Detection of Explosives","volume":"85","author":"Bauer","year":"2006","journal-title":"Appl. Phys. B"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1007\/s00340-008-3134-z","article-title":"Potentials and Limits of Mid-Infrared Laser Spectroscopy for the Detection of Explosives","volume":"92","author":"Bauer","year":"2008","journal-title":"Appl. Phys. B"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Van Damme, I.M., Mestres-Fit\u00f3, P., Ramaker, H.-J., Hulsbergen, A.W.C., Van Der Heijden, A.E.D.M., Kranenburg, R.F., and Van Asten, A.C. (2023). Rapid and On-Scene Chemical Identification of Intact Explosives with Portable Near-Infrared Spectroscopy and Multivariate Data Analysis. Sensors, 23.","DOI":"10.3390\/s23083804"},{"key":"ref_4","unstructured":"Druy, M.A., and Crocombe, R.A. (2011). Next-Generation Spectroscopic Technologies IV, SPIE."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"4362","DOI":"10.1364\/AO.49.004362","article-title":"Detection of Explosives Based on Surface-Enhanced Raman Spectroscopy","volume":"49","author":"Wackerbarth","year":"2010","journal-title":"Appl. Opt."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1007\/s00340-013-5500-8","article-title":"Detection of Explosives and Latent FIngerprint Residues Utilizing Laser Pointer\u2013Based Raman Spectroscopy","volume":"113","author":"Malka","year":"2013","journal-title":"Appl. Phys. B Laser Opt."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"11451","DOI":"10.1021\/acs.analchem.1c01397","article-title":"Direct Electrochemical Determination of Peroxide-Type Explosives Using Well-Dispersed Multi-Walled Carbon Nanotubes\/Polyethyleneimine-Modified Glassy Carbon Electrodes","volume":"93","author":"Arman","year":"2021","journal-title":"Anal. Chem."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"5323","DOI":"10.1021\/acs.analchem.9b00257","article-title":"Direct and Selective Electrochemical Vapor Trace Detection of Organic Peroxide Explosives via Surface Decoration","volume":"91","author":"Krivitsky","year":"2019","journal-title":"Anal. Chem."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Li, L., Gu, H., Lv, Y., Zhang, Y., He, X., and Li, P. (2022). Ultra-Fast Polarity Switching, Non-Radioactive Drift Tube for the Miniaturization of Drift-Time Ion Mobility Spectrometer. Sensors, 22.","DOI":"10.3390\/s22134866"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"23269","DOI":"10.3390\/s141223269","article-title":"Development of a Molecularly Imprinted Polymer-Based Sensor for the Electrochemical Determination of Triacetone Triperoxide (TATP)","volume":"14","author":"Mamo","year":"2014","journal-title":"Sensors"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"8008","DOI":"10.1021\/ac401962b","article-title":"Sensitive Determination of Triacetone Triperoxide Explosives Using Electrogenerated Chemiluminescence","volume":"85","author":"Parajuli","year":"2013","journal-title":"Anal. Chem."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1016\/j.ijms.2010.08.011","article-title":"Improved Analysis of Explosives Samples with Electrospray Ionization-High Resolution Ion Mobility Spectrometry (ESI-HRIMS)","volume":"298","author":"Hilton","year":"2010","journal-title":"Int. J. Mass Spectrom."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"17662","DOI":"10.1021\/acs.analchem.2c04450","article-title":"Direct Determination of Peroxide Explosives on Polycarbazole\/Gold Nanoparticle-Modified Glassy Carbon Sensor Electrodes Imprinted for Molecular Recognition of TATP and HMTD","volume":"94","author":"Apak","year":"2022","journal-title":"Anal. Chem."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"2655","DOI":"10.1007\/s13361-019-02335-y","article-title":"Utilizing Surface Acoustic Wave Nebulization (SAWN) for the Rapid and Sensitive Ambient Ionization Mass Spectrometric Analysis of Organic Explosives","volume":"30","author":"Pintabona","year":"2019","journal-title":"J. Am. Soc. Mass Spectrom."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1007\/s00604-020-04409-1","article-title":"A Field-Applicable Colorimetric Assay for Notorious Explosive Triacetone Triperoxide through Nanozyme-Catalyzed Irreversible Oxidation of 3, 3\u2032-Diaminobenzidine","volume":"187","author":"Akhond","year":"2020","journal-title":"Microchim. Acta"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"S61","DOI":"10.1007\/BF02492084","article-title":"Liquid Chromatography\u2014Post-Column Photochemical Conversion and Electrochemical Detection for Determination of Peroxide-Based Explosives","volume":"57","author":"Karst","year":"2003","journal-title":"Chromatographia"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1016\/S0003-2670(03)00212-5","article-title":"Determination of Triacetonetriperoxide in Ambient Air","volume":"482","author":"Karst","year":"2003","journal-title":"Anal. Chim. Acta"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"8150","DOI":"10.1021\/ac0609834","article-title":"Determination of Peroxide-Based Explosives Using Liquid Chromatography with On-Line Infrared Detection","volume":"78","author":"Edelmann","year":"2006","journal-title":"Anal. Chem."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"116735","DOI":"10.1016\/j.ijms.2021.116735","article-title":"Ambient Ionisation Mass Spectrometry for the Trace Detection of Explosives Using a Portable Mass Spectrometer","volume":"471","author":"Burns","year":"2022","journal-title":"Int. J. Mass Spectrom."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/j.snb.2017.01.143","article-title":"A Cyanostilbene-Boronate Based AIEE Probe for Hydrogen Peroxide\u2014Application in Chemical Processing","volume":"245","author":"Dhoun","year":"2017","journal-title":"Sens. Actuators B Chem."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"105290","DOI":"10.1016\/j.microc.2020.105290","article-title":"Highly Efficient Fluorescent Film Probe of Hydrogen Peroxide Vapor","volume":"158","author":"Zhang","year":"2020","journal-title":"Microchem. J."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"6967","DOI":"10.1021\/acs.analchem.9b01255","article-title":"Turn-on Fluorescent Detection of Hydrogen Peroxide and Triacetone Triperoxide via Enhancing Interfacial Interactions of a Blended System","volume":"91","author":"Yu","year":"2019","journal-title":"Anal. Chem."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1016\/j.talanta.2019.04.071","article-title":"Titanium Dioxide Nanoparticles\u2013Based Colorimetric Sensors for Determination of Hydrogen Peroxide and Triacetone Triperoxide (TATP)","volume":"202","author":"Durmazel","year":"2019","journal-title":"Talanta"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"7032","DOI":"10.1039\/C9RA00693A","article-title":"Sensitive and Fast Fluorescence-Based Indirect Sensing of TATP","volume":"9","author":"Fan","year":"2019","journal-title":"RSC Adv."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1021\/acssensors.8b01029","article-title":"Solid-State Fluorescence-Based Sensing of TATP via Hydrogen Peroxide Detection","volume":"4","author":"Fan","year":"2019","journal-title":"ACS Sens."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"13661","DOI":"10.1039\/C9CC06737J","article-title":"Handy Fluorescent Paper Device Based on a Curcumin Derivative for Ultrafast Detection of Peroxide-Based Explosives","volume":"55","author":"Zhu","year":"2019","journal-title":"Chem. Commun."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"109721","DOI":"10.1016\/j.dyepig.2021.109721","article-title":"Synthesis of a Highly Emissive Carboxylated Pyrrolidine-Fused Chlorin for Optical Sensing of TATP Vapours","volume":"195","author":"Vargas","year":"2021","journal-title":"Dye. Pigment."},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Guan, X., Huang, C., Liu, G., Meng, X., and Liu, Q. (2016). Mapping Rice Cropping Systems in Vietnam Using an NDVI-Based Time-Series Similarity Measurement Based on DTW Distance. Remote Sens., 8.","DOI":"10.3390\/rs8010019"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"11779","DOI":"10.1039\/c3cc47631f","article-title":"A Selective Fluorescence Turn-on Sensor for Trace Vapor Detection of Hydrogen Peroxide","volume":"49","author":"Xu","year":"2013","journal-title":"Chem. Commun."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"8708","DOI":"10.1021\/am501502v","article-title":"Fluorescence Ratiometric Sensor for Trace Vapor Detection of Hydrogen Peroxide","volume":"6","author":"Xu","year":"2014","journal-title":"ACS Appl. Mater. Interfaces"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/19\/8264\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T21:01:51Z","timestamp":1760130111000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/19\/8264"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10,6]]},"references-count":30,"journal-issue":{"issue":"19","published-online":{"date-parts":[[2023,10]]}},"alternative-id":["s23198264"],"URL":"https:\/\/doi.org\/10.3390\/s23198264","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,10,6]]}}}