{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T02:34:15Z","timestamp":1760150055126,"version":"build-2065373602"},"reference-count":27,"publisher":"MDPI AG","issue":"20","license":[{"start":{"date-parts":[[2023,10,10]],"date-time":"2023-10-10T00:00:00Z","timestamp":1696896000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003725","name":"National Research Foundation of Korea","doi-asserted-by":"publisher","award":["2021M3F7A1084418"],"award-info":[{"award-number":["2021M3F7A1084418"]}],"id":[{"id":"10.13039\/501100003725","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A multichannel soft X-ray (SXR) array has been developed to measure the electron temperature in the Versatile Experiment Spherical Torus (VEST). To estimate electron temperature using the two-filter method applied to SXR intensity, we designed a pinhole camera that has two photodiode arrays with different metallic filters. We also adopted a filter wheel and tested various filter parameters to find the optimal filter set. Through tests, the combination of aluminum and beryllium was found to be the most suitable for the current experimental conditions in VEST. The filtered SXR signals were acquired with a low-noise preamplifier, exhibiting sufficient signal-to-noise ratios for electron temperature estimation based on the intensity ratio of two signals obtained with different filters. The estimated electron temperature from the developed two-filter SXR array showed reasonably matched levels and consistent trends with Thomson scattering measurements. Error contribution from impurity line emission is also discussed.<\/jats:p>","DOI":"10.3390\/s23208357","type":"journal-article","created":{"date-parts":[[2023,10,10]],"date-time":"2023-10-10T10:23:42Z","timestamp":1696933422000},"page":"8357","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Electron Temperature Measurements Using a Two-Filter Soft X-ray Array in VEST"],"prefix":"10.3390","volume":"23","author":[{"given":"M. W.","family":"Lee","sequence":"first","affiliation":[{"name":"Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"Lim","sequence":"additional","affiliation":[{"name":"Department of Energy Systems Engineering, Seoul National University, Seoul 08826, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8475-2610","authenticated-orcid":false,"given":"W.","family":"Jeong","sequence":"additional","affiliation":[{"name":"Department of Energy Systems Engineering, Seoul National University, Seoul 08826, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5074-7987","authenticated-orcid":false,"given":"S.","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Energy Systems Engineering, Seoul National University, Seoul 08826, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J. H.","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Energy Systems Engineering, Seoul National University, Seoul 08826, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4010-9241","authenticated-orcid":false,"given":"Y. S.","family":"Hwang","sequence":"additional","affiliation":[{"name":"Department of Energy Systems Engineering, Seoul National University, Seoul 08826, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8122-0018","authenticated-orcid":false,"given":"C.","family":"Sung","sequence":"additional","affiliation":[{"name":"Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2023,10,10]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1245","DOI":"10.1088\/0741-3335\/49\/8\/010","article-title":"A \u2018Multi-Colour\u2019 SXR Diagnostic for Time and Space-Resolved Measurements of Electron Temperature, MHD Activity and Particle Transport in MCF Plasmas","volume":"49","author":"Stutman","year":"2007","journal-title":"Plasma Phys. Control. Fusion"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"056116","DOI":"10.1063\/1.2895408","article-title":"Measurements of Core Electron Temperature and Density Fluctuations in DIII-D and Comparison to Nonlinear Gyrokinetic Simulations","volume":"15","author":"White","year":"2008","journal-title":"Phys. Plasmas"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"065010","DOI":"10.1088\/0741-3335\/50\/6\/065010","article-title":"MHD as Trigger of Electron Temperature Oscillations in ECCD Discharges in TCV","volume":"50","author":"Turri","year":"2008","journal-title":"Plasma Phys. Control. Fusion"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"053015","DOI":"10.1088\/0029-5515\/53\/5\/053015","article-title":"Characterization of Saturated MHD Instabilities through 2D Electron Temperature Profile Reconstruction from 1D ECE Measurements","volume":"53","author":"Sertoli","year":"2013","journal-title":"Nucl. Fusion"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"066013","DOI":"10.1088\/0029-5515\/56\/6\/066013","article-title":"2D\/3D Electron Temperature Fluctuations near Explosive MHD Instabilities Accompanied by Minor and Major Disruptions","volume":"56","author":"Choi","year":"2016","journal-title":"Nucl. Fusion"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1088\/1009-0630\/15\/3\/11","article-title":"Design Features and Commissioning of the Versatile Experiment Spherical Torus (VEST) at Seoul National University","volume":"15","author":"Chung","year":"2013","journal-title":"Plasma Sci. Technol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1016\/j.fusengdes.2019.03.130","article-title":"Development of Thomson Scattering System on VEST","volume":"143","author":"Kim","year":"2019","journal-title":"Fusion Eng. Des."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"063501","DOI":"10.1063\/1.3443572","article-title":"First Results Obtained from the Soft X-ray Pulse Height Analyzer on Experimental Advanced Superconducting Tokamak","volume":"81","author":"Xu","year":"2010","journal-title":"Rev. Sci. Instrum."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"053501","DOI":"10.1063\/5.0040511","article-title":"Toroidal Soft X-ray Array on the EXL-50 Spherical Tokamak","volume":"92","author":"Huang","year":"2021","journal-title":"Rev. Sci. Instrum."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"11E419","DOI":"10.1063\/1.4890406","article-title":"Silicon Drift Detector Based X-ray Spectroscopy Diagnostic System for the Study of Non-Thermal Electrons at Aditya Tokamak","volume":"85","author":"Purohit","year":"2014","journal-title":"Rev. Sci. Instrum."},{"key":"ref_11","first-page":"P10016","article-title":"Laboratory Tests of the Pulse Height Analysis System for Wendelstein 7-X","volume":"10","author":"Kubkowska","year":"2015","journal-title":"J. Inst."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"4930","DOI":"10.1063\/1.1808911","article-title":"Soft X-ray Pulse Height Analyzer in the HT-7 Tokamak","volume":"75","author":"Shi","year":"2004","journal-title":"Rev. Sci. Instrum."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"083504","DOI":"10.1063\/5.0058112","article-title":"Double-Filter High-Resolution Soft X-ray Tomographic Diagnostic for Investigating Electron Acceleration in TS-6 Reconnection Merging Experiments","volume":"92","author":"Xiang","year":"2021","journal-title":"Rev. Sci. Instrum."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"10E129","DOI":"10.1063\/1.4740274","article-title":"High-Performance Double-Filter Soft X-ray Diagnostic for Measurement of Electron Temperature Structure and Dynamics","volume":"83","author":"McGarry","year":"2012","journal-title":"Rev. Sci. Instrum."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"073304","DOI":"10.1063\/1.2786034","article-title":"Fast Electron Temperature Measurements Using a \u201cMulticolor\u201d Optical Soft X-ray Array","volume":"102","author":"Stutman","year":"2007","journal-title":"J. Appl. Phys."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"112656","DOI":"10.1016\/j.fusengdes.2021.112656","article-title":"Conceptual Design of Tomographic Soft X-ray Detectors for COMPASS-U Tokamak","volume":"168","author":"Svoboda","year":"2021","journal-title":"Fusion Eng. Des."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"11E827","DOI":"10.1063\/1.4896960","article-title":"Installation of Soft X-ray Array Diagnostics and Its Application to Tomography Reconstruction Using Synthetic KSTAR X-ray Images","volume":"85","author":"Lee","year":"2014","journal-title":"Rev. Sci. Instrum."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"11E317","DOI":"10.1063\/1.4960418","article-title":"Developments of Scintillator-Based Soft X-ray Diagnostic in LHD with CsI:Tl and P47 Scintillators","volume":"87","author":"Bando","year":"2016","journal-title":"Rev. Sci. Instrum."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"033503","DOI":"10.1063\/1.4867662","article-title":"Application of AXUV Diode Detectors at ASDEX Upgrade","volume":"85","author":"Bernert","year":"2014","journal-title":"Rev. Sci. Instrum."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"126011","DOI":"10.1088\/1741-4326\/ac2b78","article-title":"Acceleration of Ion Rotation during Internal Reconnection Events in the Versatile Experiment Spherical Torus (VEST)","volume":"61","author":"Kim","year":"2021","journal-title":"Nucl. Fusion"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"2157","DOI":"10.1063\/1.1537875","article-title":"Soft-X-ray Emission, Plasma Equilibrium, and Fluctuation Studies on Madison Symmetric Torus","volume":"74","author":"Xiao","year":"2003","journal-title":"Rev. Sci. Instrum."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.hedp.2005.07.001","article-title":"FLYCHK: Generalized Population Kinetics and Spectral Model for Rapid Spectroscopic Analysis for All Elements","volume":"1","author":"Chung","year":"2005","journal-title":"High Energy Density Phys."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1016\/j.fusengdes.2018.10.021","article-title":"Effect of Boronization in VEST: Achieving 0.1 MA Discharge","volume":"137","author":"Yang","year":"2018","journal-title":"Fusion Eng. Des."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Ralchenko, Y., and Kramida, A. (2020). Development of NIST Atomic Databases and Online Tools. Atoms, 8.","DOI":"10.3390\/atoms8030056"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"11D850","DOI":"10.1063\/1.4892540","article-title":"Design and Initial Operation of a Two-Color Soft X-ray Camera System on the Compact Toroidal Hybrid Experiment","volume":"85","author":"Herfindal","year":"2014","journal-title":"Rev. Sci. Instrum."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1143\/JJAP.25.120","article-title":"Effects of Light Impurities on Electron Temperature Measured by Soft X-ray Filter Method","volume":"25","author":"Morimoto","year":"1986","journal-title":"Jpn. J. Appl. Phys."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"033502","DOI":"10.1063\/1.4867076","article-title":"2D Electron Temperature Diagnostic Using Soft X-ray Imaging Technique","volume":"85","author":"Nishimura","year":"2014","journal-title":"Rev. Sci. Instrum."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/20\/8357\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T21:04:07Z","timestamp":1760130247000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/20\/8357"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10,10]]},"references-count":27,"journal-issue":{"issue":"20","published-online":{"date-parts":[[2023,10]]}},"alternative-id":["s23208357"],"URL":"https:\/\/doi.org\/10.3390\/s23208357","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2023,10,10]]}}}